The full acceptance campaign on dev image 20260821181036, the first built on
the <recipe>-pin.inc layout, satisfied 42 of 42 and its export authorizes a
release, so the status header, the acceptance section and item 12 describe
that rather than a campaign still owed; the catalog count is 42, not 35.
CAMPAIGN-LOG records the completion. Item 7 stops listing the cloud work the
campaign closed (the oversize live print, the progress bar watched from the
app, packaged-path cloud boot, the lid flash), records the operator's
declines (SPKI pinning, emulator parity, the ten-event pause machine) and the
reasoned memory guards, and item 19 no longer lists MCsn and PDfm as
unchecked: the client refuses both, so seventeen mandatory tags are dropped,
not nineteen.
forgefirm-app pin moves to b82d379 (python3-gfhardware): CLOUD.md and three
present-tense comments, no behavior change. No catalog consequence beyond the
pin bump itself, which the manifest scopes to the component.
laser.pause-resume-lid-cancel failed on the bench with the head 14.925 mm
along the first leg after the lid cancel: the driver took every resume
from a feed hold as a new job start (the core restarts a held cycle
through Idle), so the cancel returned the head to the pause point and
said "returned to the job start" about it. The driver fix is in
grblHAL-glowforge; this is its proof and the record.
The null-sink lifecycle harness gains rule 9: a job paused and resumed by
the button, then cancelled by the lid, returns to where the job began
(reproduces the bench failure to the millimeter on the old driver,
X=13.088 instead of 0); and a job abandoned in a hold and soft-reset is
over, so the next job from that spot returns to that spot. The campaign
log carries the dated account.
No catalog consequence: the acceptance test measured exactly this and
stays as it is; the harness is the CI side of the same contract.
The cloud job tests enter cloud mode and stay there, by design, so a
queue (or an operator) that goes on to a motion test reaches it with
gfcloud as the controller and no grblHAL process to find:
motion.step-timing-under-load failed on exactly that, before it touched
the machine. Nothing in the runner put the machine into the mode a test
needed; the baseline only preserved the mode it found.
A test now declares `mode="grbl"` (or "cloud") in @test. The runner's pre
pass, after the leftovers are handled and before the preserved state is
captured, switches through POST /mode, waits for the supervisor to settle
(controller running, motion verified) and for the Grbl port to answer,
and fails the test with the reason when the mode cannot be established.
Capturing after the switch means the post pass keeps the mode the test
asked for, so the machine changes mode only where the next test asks for
it and never between tests of the same mode. The cloud job tests keep
managing their own entry (enter_cloud also waits for the service
session) and declare nothing.
Tagged: every motion.* test but the mode-agnostic liveness probe, the six
laser.* tests, cooling.fans-quiet-after-motion, cloud.mode-switch and
cloud.gfhome-homing (both start in GRBL mode). controller_pid() now says
what mode forgectrl reports when the process is missing. The page shows
the declared mode as a badge; the Grbl port probe moved to hw.
Proof: tests/test_mode.py (switch_mode against the fake forgectrl,
including a refused switch, a controller that never comes up and a port
that never opens; the runner end to end from cloud mode, from grbl mode,
an undeclared test, and a failed switch). 151 unit tests pass; the
coverage lint is clean. No catalog consequence beyond the suite modules'
own source hashes: the change is to how a test is started, not to what
it proves.
A campaign is mostly waiting for the next Start. The page now offers two
queues, and each takes every test of its kinds the campaign does not
already count as satisfied: Unattended for the auto tests, which need
nobody in the room, and Operator and live for the ones that need somebody
at the machine, since they prompt and they fire the laser. The buttons
say how many they would run and ask before starting; the live queue names
the tests that fire and takes the acknowledgment once, for all of them.
A queue runs one test at a time through the runner's single slot, in
prerequisite order. Registration order otherwise, so a run reads down the
page, but a prerequisite inside the queue always goes first. It stops on
the first result that is not a PASS: a FAIL closes the campaign, and
carrying on would only open a second one behind the operator's back. A
test the runner refuses to start is skipped with the reason on the page
and the rest carry on, which is what happens to an auto test waiting on an
operator one: run the attended queue, then the unattended one again.
The queue lives in the runner, not in the tab, so reloading the page or
closing it leaves the run alone. While one is up it holds the machine
between its tests as well as during them, so a single Start and the bench
tools are refused rather than cutting in. Stop the queue cancels what is
still waiting and lets the run in progress finish; Abort ends that one
too, and lands as the non-PASS that stops the queue. Every run a queue
starts records which one put it there.
Also moves the /state ETag test to the end of its class. It invalidates,
timestamps are whole seconds, and a PASS stamped in the same second as an
invalidate is deliberately not inheritable, so on a fast run it decided
the inheritance an earlier test was checking.
forgetest is a dev-only component and can never appear in a coverage map,
so this has no acceptance catalog consequence.
The work ran from 2026-08-18 to 2026-08-20 and is finished, so the plan it ran
from is retired the way plans are retired here: what is durable moved into the
documents that describe the present, and the dated record of how the result was
obtained lands here.
The entry keeps the parts that live nowhere else. That the campaign started
from a wrong belief and was corrected by the factory itself, which stages a job
into its ring in free-checked segments and then appends to it for as long as
the job lasts. That the proof was already on the machine, a 107 MB job played
through a 32 MiB ring in this board's own factory logs. The two defects the
building surfaced, a dry ring reporting success and a pause that could not
retrace on a streamed job. And what it cost to be sure: a decoder 41 times too
slow to keep a ring fed, which only showed itself against a real 53 MB job.
They were open because the service has never sent them and cannot be asked
to. That is not a reason to leave them open: the factory application says
what each one does, and it says all four are hand-offs to programs this
machine does not have. BRINGUP's cloud item now records the disposition
rather than the question.
Two tests already run a print end to end, and progress is a property of a
running print, so the checks go there rather than into a test of their own
that would cost the operator another job.
cloud.pause-resume takes the job that fits the ring: the client names the
length it is reporting against, and the operator is asked the question only a
person can answer, whether the bar actually moved.
cloud.oversize-stream takes the job that does not fit, which is where a moving
denominator would show: the kernel's program total grows all run long under a
live feed, and the test already samples it growing, so the check is that the
figure progress divides by is larger than that - the job, not the count the
ring had swallowed when the run started.
The forgetest replay plays a captured log from a build that predates the line,
so it carries the line where the current build emits it, as it already does
for the warm-up and the rest.
BRINGUP's cloud item now says a print reports itself again, and what is left
on it is a print watched from the app.
The campaign log gains the F1 entry: the question was which of three carriers
the factory uses for the progress bar, and the answer is that two of them
collapse into one. Progress rides an outbound WSS type:"progress" frame that is
itself the periodic settings report, every 30 s. The write-up lives in CLOUD.md;
the log records how it was gotten and what else the capture proved, including a
factory progress total that grew 256 KiB per interval because the factory
live-appends to its own ring.
BRINGUP's cloud item now lists F2 among the open work with the carrier settled,
so what is owed is emitting the frame against the feeder's job total rather
than the kernel byte counter.
Documentation only, no behavior change, so no acceptance-catalog consequence.
cloud.pause-resume runs a print end to end, which is exactly what the job
lifecycle needs to be seen: a non-zero hold before the first fire, a non-zero
rest after the park, and neither on the connect-time hunt in the same
session. Folding the checks in there costs the operator nothing, where a
test of its own would cost another print.
The forgetest replay noticed first: it plays a real captured log from a build
that predates those lines. Rather than editing what the machine said that
day, the replay carries the two lines where the current build emits them.
BRINGUP's cloud item now names what is actually open on the header keys, the
park and the two periods, and records that the pause constants were looked
for in the wrong place.
BRINGUP's cloud item said a print is capped by the ring and listed the two
gaps that closed when it stopped being. It now says what bounds a print
(memory, through pulse_reject_threshold_bytes) and what catches a feed that
wedges (progress against room, not ring depth), and it names the two new
cases that cannot be induced from the bench: a body past the memory guard,
because the service has no such job to send, and a wedged feed, because a
healthy machine will not stall on request.
forgectrl.settings-bounds gains a probe at the far end of the new byte
range, so the validator behind those keys is exercised rather than assumed.
kernel.backtrack-bounds plays a program, stops it, and holds the readback
to the bytes it played less the deceleration tail: a step past the boundary
has to be refused rather than quietly shortened, and the run at the boundary
has to play out and come back idle. Motors locked, latch locked, duty zero,
so nothing moves and nothing fires.
cloud.oversize-stream pauses and resumes the live-fed print it already has
running. That is the pause the kernel change makes possible, and it costs a
minute of a job that is on the bed either way.
BRINGUP's pause bullet, its ring facts and item 18 all said a ring under a
live feed has nothing left to back into. The gap the writer keeps clear says
otherwise; what is still open for GRBL mode is the bookkeeping above the
ring, not the kernel below it.
The ring and the device-tree pool that backs it are now the size the
factory firmware runs. Docs follow, and the hardware facts bank gains the
reserved-memory map: 511 MiB usable, 96 MiB reserved for DMA, ~454 MiB
left to Linux.
image.health reads the pool size and ring_mb back and fails if they
disagree, so a pool the parameter does not use cannot ship unnoticed, and
checks that free never exceeds the ring less its gap.
Next-work item 19 carried three open questions about the factory's
operating envelope. All three are answered now, so the item states the
policy instead of the guess.
A fan tach alert during a cut pauses the print, taking the same transition
a user pause takes, and two of the factory's three tach monitors cannot
fire at all: they treat a zero limit as unconfigured and the limits arrive
zero anyway. So a stalled extraction fan is caught by the temperature it
causes, not by its tachometer. Every temperature alert pauses as well, and
a critical fails the machine outright, which is a different state and not a
pause. The scale question behind the header's ceilings is answered by the
coolant family, which the factory carries twice, once in raw ADC counts
where the tag named min is the hot limit, and once in millidegrees. And the
factory does not verify coolant flow at all, so the cooling engine's flow
check is ahead of the factory rather than behind it.
The crash, tilt and beam-detect bullets gain the same grading: an alert
threshold that pauses and a separate abort threshold that aborts.
Also drops references to paths that resolve outside this repo, in both
documents and in two bench scripts, naming the artifact instead. In
CAMPAIGN-LOG that is a wording substitution only; no date, claim or
measurement changes.
Documentation only, so no acceptance catalog consequence.
The section describes two channels flowing opposite ways - the
controller's job-state reports and the engine's verdict - so "the report"
pointed at the wrong one directly under a lead that names the verdict.
MOTION said jogs, homing and hunts were all ungated. Jogs are:
gfsw_visible withholds the door signal while the core is idle, jogging or
homing, so a jog both starts and runs with the lid open. Homing is not.
With homing_mode = gfcloud - the only method that works today - $H hands
the cycle to a cloud homing session, and its move to the home corner is
an ordinary motion action taking the default lid_gated=True: refused with
the lid open, stopped on a lid edge mid-run. Only the lens/Z hunt inside
that session passes lid_gated=False, and that session is also the only
place a hunt happens in GRBL mode - there is no hunt outside one.
BRINGUP gains item 18: GRBL pause and resume should leave no gap in the
cut, the way the factory's does. The beam stops at the start of the hold
(disable_laser_during_hold, on by default), so the head travels the whole
deceleration dark and the resume restarts from a standstill where the
decel ended - an unburned length, then a dwell through the accel that M3
shows as a deeper spot. The kernel waypoint backtrack cloud mode uses is
refused with EPERM on a live-streamed ring, so the equivalent has to be
built above the ring, where grblHAL still holds the planned path the
kernel has already overwritten.
Two wording fixes: the cooling verdict is described as a report rather
than a file, and gfcloud homing as using the machine's builtin
credentials.
Documentation only - no behavior change, so no acceptance-catalog
consequence.
grblHAL-glowforge 03d70e0, pinned here, makes density the shipped model
and $35 the density floor at 10. Every analog session in the stream
harness now selects its model rather than inheriting it: without that the
flip would have quietly turned them into density runs and taken the
analog fallback's coverage with them. laser.power-floor carries the new
floor and its PWMSAR minimum, and its description no longer describes
$35 as a duty floor.
All ten stream sessions pass on the new defaults, with the analog duties
shifting exactly as the floor predicts - min_value 12, gradient 0.115 -
along with both C harnesses and the lifecycle harness.
Recorded in BRINGUP and the campaign log, including what the defaults
rest on and what they do not: the seven ladders ran at F300 and F100 at
constant power, so production feeds, M4 into corners and the raster path
remain unproven on hardware.
$35 = 10 under the density model is a density floor, not a duty floor. It
maps S onto 9.4-100 percent density, so a commanded 1 percent lands at
10.2 percent, just above the marking floor the earlier ladders measured.
A ladder reweighted to the bottom of the user scale - 1, 2, 5, 10, 20,
40, 70, 100 percent of S - marked on all eight rungs, with eight current
segments over a 42.0 s window against exactly 8 x 5.25, and segment means
climbing 136 to 968.
That meets the goal the ladders started from: a user's 1 percent is a
real visible mark rather than silence, and 100 percent is full power. It
took all three pieces - density so every level is real pulses, the
minimum pulse so they stay strikeable, the floor so the user's range sits
on the band that works.
dladder no longer tells the operator to re-run at other base periods to
choose one. The period cancels out of the low end, and what a failing
rung now indicates is a floor set too low.
min_ticks 6 broke 5 percent striking - seven current segments where 3 gave
eight, on a 36.5 s fire window against 41.4 s for eight rungs. Below the
minimum the model emits min ticks every min/on periods, so the interval
between pulses is min_ticks x tick / density and the base period cancels,
which is also why periods 10, 20 and 40 gave identical results earlier.
At 5 percent that is 2.26 ms at min 3, which struck, against 4.51 ms at 6,
which did not: doubling the minimum doubles the gap as well as the pulse,
and the discharge is re-struck each pulse.
min 3 sits at the factory's own operating point - its 6.5 percent engrave
jobs place 100 us pulses 1.54 ms apart against 1.64 ms for min 3 at that
density - and 6 is outside anything the factory does. The bench is back
at 3.
Measured band for this tube: strikes from ~5 percent density, marks from
~10 percent at F300. That closes the pulse-structure route to a usable
1 percent, since the interval grows as 1/density and 1 percent implies an
11 ms gap. The low end is a scaling problem, and $35 is the control.
The fifth ladder, the first with a minimum pulse, moved the floor down a
full rung: only 5 percent failed to mark, and 5 percent now strikes. The
trace carries eight current segments where the run before it had seven,
with fire beginning at 6.2 s exactly at rung 1 and the usual flat
saturated final segment anchoring the count from the other end.
That retracts what the previous entry concluded. Pulse length is not
irrelevant: 10 percent moved from no mark at F100, with three times the
dose per millimeter, to a mark at F300 at the same density, the only
change being its pulses growing from 36-71 us stubs to 106 us. The
matched-pairs argument was sound but drawn entirely from comparisons at
or above 20 percent density, where every pulse length in play was already
long enough - it generalized from the one regime where pulse length does
not bite. Above ~100 us dose governs; below it pulse length does; below
~36 us the supply does not strike. The factory's 100 us quantum sits on
that boundary.
dladder now reads laser_pulse_min_ticks and prints what is actually
emitted. Without that its table reports the pulse density alone would
give, which is wrong wherever the minimum applies - at min 6 the bottom
four rungs all emit 213 us and vary their rate instead, and the operator
reads that table to interpret the material.
Rule 15 in the stream harness holds both halves of the minimum
(grblHAL-glowforge f7e8c17, pinned here): no emitted burst falls below
laser_pulse_min_ticks, excepting one clipped by fire going off mid-burst,
and the levels too faint to fill a window still render their exact
average density. Checked against a run at minimum 1 so it cannot pass
vacuously - level 2 goes from 444 bursts of one tick to 147 of three at
the same density, and levels already above the minimum are unchanged.
Four bench ladders settle the base period at 20. The same six rungs
marked in all of them, and the matched pairs across periods separate the
variables: at identical pulse length, halving the density killed the
mark; at identical density, varying the pulse 3x changed nothing. Feed
does not move it either - 10 percent at F100 carries 44 percent more
energy per mm than 20 percent at F300, which marks, and still left
nothing. The low-end marking limit is average power, not dose per length
and not pulse length.
The F100 trace separates two failures that look alike on the material:
seven current segments for eight rungs, anchored by a flat saturated
final segment that can only be full density, put 5 percent at no
discharge at all and 10 percent at a full 15 seconds of current with no
mark. Only the first is ours, and the minimum pulse is the answer to it.
Also recorded: the factory's Precision Power 1 runs a 19.53 percent FIRE
duty cycle at full PWM duty, and its 1-100 scale maps onto density
18.9-79.5 percent, so its 1 percent is the bottom of the useful band
rather than 1 percent of the range. Under the density model $35 and $36
are that same control - a density floor and ceiling - which makes the
user-facing scale a settings choice rather than new code.
Four new sessions in the stream harness cover the model (grblHAL-glowforge
2bca017, pinned here). Density renders the commanded level exactly -
levels 2, 3, 7, 15, 25 and 38 came back as 0.0158, 0.0237, 0.0551,
0.1182, 0.1969 and 0.2993 against level/127 of 0.01575, 0.02362, 0.05512,
0.11811, 0.19685 and 0.29921 - S1000 renders 1.0000 and still ends dark,
every power byte carries full duty, and a level change inside a run costs
no stream byte where analog ships one per level.
Rule 13 is the one worth having: the same job run under both models
produces an identical motion grid tick for tick, and all 20051 density
FIRE ticks fall inside the 169776 the analog run fired. The model masks
the core's fire state and never sources one, measured rather than argued.
Rule 14 covers the idle-gap fix: a standalone S between moves, from a
sender slow enough to drain the planner, now fires each move at its own
level (28338 ticks each at duties 30, 52 and 84). Before the fix duty 30
held all 85014 and the other two levels never appeared. That closes
"Next work" item 18, which this work opened earlier today.
The harness now derives its expectations from the board's floor and
chains two launches over one settings file, because the core precomputes
the S to duty mapping once when the spindle is enabled: $35 written at
runtime persists and reports immediately but only enters force at the
next controller start. That is recorded in BRINGUP beside the existing
defaults note, and laser.power-floor's failure message now says so.
Acceptance: the density path shipping off by default is inert until
laser_power_model is set, and the laser tests' covers already name
grblhal-glowforge src/**; the model's own acceptance test waits on the
bench drill that picks the base period.
The pthresh ladder on scrap puts the tube's two thresholds far apart: the
discharge strikes between 2 and 3 percent duty, but nothing lases usefully
below 16 percent (PWMSAR 20), and the rungs between show only a spot at
each line start. $35 ships at 16 (grblhal-glowforge 9466f76, pinned here).
The drill said current lift-off and first mark share a rung; this run
falsifies that, so its docstring and read-the-material text now name both
thresholds and warn that a start-of-line spot is below the threshold, not
at it.
A start-of-line spot is also what a full-power leak at a kernel run start
would look like, so laser_stream_test gains a ladder session (rule 10):
every FIRE tick must ride a commanded duty, and the fire ticks must divide
evenly across rungs. Both hold exactly - six commanded duties, no others,
and 28296 fire ticks on every rung - so the spots are the tube, not the
stream. The harness now derives its expectations from the floor, which
moves the M4 session's S500 plateau from 63 to 73.
laser.power-floor is a new auto acceptance test, the suite's only
non-firing one: a machine must actually carry the commissioned floor,
since stored settings beat freshly baked defaults.
Three cloud cuts of one square at Precision Power 1, 100 and Full Power
show what the analog path is competing with: the power byte is pinned at
127 in all three, dose is FIRE-bit density on a fixed 7-tick period with
the on-count dithered between adjacent integers, and the power setting
never reaches the machine at all. Facts bank and item 17 carry the
numbers; CAMPAIGN-LOG carries both sessions.
The dated record for the jerky-at-2000-mm/min thread: what was wrong,
what changed, and what the bench measured.
Keeps the two results that matter. The A/B that isolated the cause -
two acceptance runs 90 s apart on one image, camera the only variable,
PASS with a nice-5 CPU hog and FAIL with the camera streaming - and the
LB-GF-OG-FM job re-run on the fix with the video live, clean at
min margin 3.1 ms of 10.
Also records that max behind is not the instrument: it reads 0.0 ms
through a passing run whose real margin fell to 4.9 ms, because the
producer never falls behind its own wakeup epoch. Only the measured
min margin shows the condition.
Bump the grblHAL pin to the producer lead and margin instrumentation.
Rewrite BRINGUP item 16 to the present state. The scheduling half is
done - the producer runs SCHED_FIFO below the shipper, core_mx carries
priority inheritance, and clamping is reported per run - and two bench
runs 90 s apart on one image show what that does and does not cover: a
nice-5 CPU hog passes clean while the camera streaming clamps 7 runs,
because per-frame cache maintenance over a 4.8 MB non-coherent capture
buffer is kernel-context work no userspace priority can preempt.
Record the margin finding, since it explains why a 4 ms stall was
enough: the queue depth cancels between the shipper's due index and the
producer's base, so the pacing lead is the only slack. Record the
cycle-churn ceiling that caps that lead at 10 ms, and that the re-base
fix is what unlocks more.
Camera gating stays owed, with capture resolution named as the lever
that shortens the stall rather than merely spacing stalls out.
Bump the grblHAL pin to the real-time producer change.
Add motion.step-timing-under-load: the catalog had nothing that
exercised step generation while userspace competed for the single core,
which is exactly the gap that let the condition go unnoticed - the ring
never runs dry, so cnc/underruns reads 0 through it. The test asserts
the producer and the shipper both hold SCHED_FIFO, then drives
2000 mm/min round trips against a deliberate nice-5 CPU hog and requires
the controller to report no clamped events.
Add the pthresh live-fire drill: a constant-power ladder from 2 % to
30 % of full on scrap. Because $35 is a percent of full duty and the
rungs are percents of $30 with $31 = 0, the lowest rung that marks reads
directly as the $35 value. It needs $35 = 0 for the run, or the floor
lifts every rung and hides the threshold.
Record both open items in BRINGUP. The laser one carries the finding
that the factory never uses duty as a power control - all five firing
jobs in the captured pulse files pin the power byte at 127 and modulate
dose by dithering the FIRE bit at 6.5-18.8 % density - so the captures
cannot supply a $35 default, and the duty to optical-power transfer
function of this supply has never been measured.
docs/VIDEO.md is the user-facing camera guide: what the endpoints return, what
the sensors can do that ForgeFIRM does not send and why, the privacy gate, and
the state of 8 MP support.
The 8 MP (OV8856) capture path now reaches the sensor's full 3264x2448 frame.
Its stock RAW10 full-resolution mode runs the link at 1.44 Gbps/lane and the
i.MX6 CSI-2 D-PHY stops at 1 Gbps; the BSP adds a RAW8 mode that carries the
same frame at half the rate, so an HD machine is no longer limited to the
binned quarter-pixel mode. kas/README.md carries the reasoning, the register
deltas and the factory configuration to fall back to if the receiver will not
lock at 720 Mbps/lane.
Acceptance: camera.sensor-profile expects the new OV8856 geometry, the camera
covers map names src/camhealth.* (the src/cam.* glob does not match it, so the
lint would have gone quiet on an uncovered file at the next pin bump), and a
new auto test camera.frame-health asserts a burst of captures with no frames
the capture queue flagged errored - a real signal about the camera ribbon even
though those frames never reach a client.
Two pages aimed at someone who owns the machine rather than works on it,
written for the documentation site. Nothing here is new behavior - it is
the behavior the machine already has, explained where an owner can find
it instead of spread across a kernel contract, a services contract and
three driver headers.
MOTION.md follows one thread: everything physical comes out of a single
fixed-tick byte stream, so the page starts there - the byte layout, speed
as step density rather than clock, the ring and the two ways to fill it,
and the hardware's own stop, halt and resume-with-waypoint. The laser is
presented as part of that stream rather than beside it, which is what
makes the three contract rules (power before fire, no consecutive power
bytes, end dark) and the persisting duty legible instead of arbitrary.
Then geometry and limits, device ownership and the liveness check the
operator sees, and the two modes in full: GRBL from connection through
the arming sequence, the stop/pause/fault table and homing-or-not; cloud
from the preloaded pulse file through the pause backtrack, the park that
ignores the lid, and the ring's cap on job length. A comparison table and
the motion-related settings close it.
COOLING.md explains the engine as what it is - one owner of the thermal
hardware answering a single question for whichever controller runs - and
gives the reasons behind the numbers rather than just the numbers: why
the flow check heats and measures the downstream rise, why 40 percent is
the duty (below it, convection mimics flow), why the settle gate uses a
split-half mean instead of peak-to-peak, and why one bad reading is a
suspicion rather than a fault. Over-temperature, the two diagnostics
tools and when to run them, the settings, and a situation-to-response
table. The fire watch is described honestly: the lid IR channels are
first of all a photometer for the lid lamp, the gate ships watch-only,
and it is not a fire alarm.
Both pages state what is not implemented - low-temperature gates, TEC
control, a fire watch that acts, limit-switch homing - so nobody plans
around them. Constants come from the sources that own them (the feeder
contract, cool.h, the board header, the services contract), not from
prose. README links both.
Documentation only, no behavior change and no catalog consequence: docs/
is outside every layer and .md is excluded from the layer content hash.
BRINGUP had grown to 3,122 lines in which the same subject was answered
differently depending on where the reader stopped: GATE A "stays open, no
live-fire" in the phase text and closed in the campaign record, the catalog
at 24 tests in one section and 35 in another, several "bench validation
pending" headings over bodies that recorded the pass.
Split by kind rather than by age. BRINGUP (907 lines) is the present state
only - status, bench runbook, laser, lid/interlock/button policy, homing,
forgectrl, diagnostics, logging, release acceptance, the measured facts
bank, and a Next work list of the 15 items that are actually open.
CAMPAIGN-LOG (2,657 lines) takes the dated blocks verbatim, in
chronological order, and is append-only: a correction is a later entry, not
an edit. Its two reading rules are stated up front, since moved text keeps
its original "above"/"below" and its pre-split item numbers.
Facts corrected against the tree while rewriting: the liveness probe gates
at p2p 800, not 500, with the real wedge, noise and jolt figures; the panel
has seven tabs including Logs and is built from src/ui/, not ui.c; the
devserver replaced tools/mock.py; /status reports real head presence; the
estop_halts_motion opt-in is gone; core PR #999 is merged, leaving only the
step_us_min commit fork-only; the update system stands at Phase 5, the
uSDHC pads and the 2026-08-08 kernel batch have shipped, and 8 MP camera
capture is tracked here for the first time.
SAFETY and UPDATE-SYSTEM point their drill records at the log. ACCEPTANCE
records that inheritance is local: there is no import of a published
artifact, so a second bench starts from a full campaign - one of the four
open items the retired tool plan held, the rest of which are now in
BRINGUP's acceptance item.
Documentation only, no behavior change and no catalog consequence: docs/
is outside every layer and .md is excluded from the layer content hash.
SAFETY: the chain de-energizes itself behind a pause without being asked -
the charge-pump feed ends with the run, so HV_ENABLE drops with the watchdog
about half a second in, and on the resume it is back ~216 ms before the first
step (pad measurements). A pause is deliberately not a cancel: the latch stays
unlocked and the window open, which is what lets the next press resume the
job, while emission still ends because the stream stops driving FIRE. The
disarm grace counts down through a hold, so a job left paused disarms itself,
and a lid or interlock open while paused takes the cancel path - nothing
resumes past an enclosure opening.
LIGHTBURN: the two things an operator needs before pausing a cut - the resume
restarts from where the deceleration ended and accelerates from a standstill,
which M3 shows as a deeper spot and M4 mostly hides, and a job left paused
disarms itself and asks for the button again. Stop leaves the head where it
stopped; returning to the job start belongs to the lid and interlock policy
alone.
Item 16 becomes the record of what the machine does rather than a list of
what is left: both modes cancel a job on a lid or interlock open - running
or paused - and return the head to where the job started with the lid still
open; the park ignores the lid; the arm wait cancels with the reason named;
the button pauses and resumes, with the factory's backtrack and lead in cloud
mode and feed hold / cycle start in GRBL; lid_policy = hold keeps the stock
door behavior for senders that want it. Item 4's mid-job Door hold is that
policy now, and item 12's LightBurn door handling is closed by the cancel -
LightBurn never lives in Door on the default path.
The GRBL resume dwell that was left open is decided against, on measurement
rather than on the mark: the chain re-arms within ~3 ms of the resume while
motion restarts ~219 ms later, so there is nothing to cover.
The two planning files at the tree root are merged and removed, as the audit
plans were. What was durable in them lives here now: the factory's own
reaction timings on 2.6.0-2228, the pause/resume behavior of the safety chain
at pad resolution, and why the hardware button latch is what makes the armed
window honest. The factory session log they were written from is archived
under _RESOURCES/.
Item 15 gains the catalog's current shape: 35 tests after the parity work and
the sweep that merged the tests sharing a setup, with the auto tests left
separate.
The cloud job tests (lid-abort, lid-during-button-wait, hunt-lid-open,
pause-resume) run in cloud mode and leave the machine there: enter_cloud
reuses a live session (pid-scoped from the client's own websocket state
lines) and switches once from GRBL mode, declaring the change to the
baseline; nothing switches back. Each test judges the log from its own
window, the print by its own "print [id]: finished" line, and waits the
service's follow-up moves out (wait_quiet) before it ends. hunt-lid-open
restarts the cloud client through the supervisor's stop/start lever for
a fresh connect. The former switch-back is what failed the last bench run
of hunt-lid-open (409 machine is not idle: the service was still
re-finding the head after the lid closed).
The baseline is mode-aware: in cloud mode the client owns the GRBL
controller's init values, the lid lamp, and the position counters; the
mode itself is preserved unless the run declared the change
(Context.mode_changed); controller_mode is never handed back as a bare
setting (a bare write left the persisted mode out of step with the live
one). The undeclared-change restore now uses the captured state, which
the post pass never saw before.
The acceptance page gets an "Ignore prerequisites" switch (remembered by
the browser): POST /start {ignore_requires} starts a test whose requires
are unmet, and the run records the unmet prerequisites in its evidence
and log; they stay required for the release. The cloud tests' requires
no longer chain through cloud.mode-switch.
Proof: tests/test_cloud_suite.py replays the four tests on the bench's
own gfcloud excerpts (fixtures/) and the run loop's emitted pause/resume
lines under the real runner Context against a fake forgectrl; baseline
mode tests and the server override test; the whole suite (98) and the
coverage lint pass. Catalog consequence: cloud.* fingerprints move with
the module; the catalog hash moves with the requires.
The lid-cancel tests (motion.lid-cancel-home, laser.lid-cancel-mid-fire)
now check that the KERNEL position counters returned to the job start,
not only grbl's MPos - grbl's drift read 0.000 while the head had not
moved. The baseline reports unplayed bytes queued in the kernel ring
(cnc/position total minus processed) as a leftover and refuses its
return jog while any exist: a run started on top of them replays them
first, which is what put the head into the rail. BRINGUP item 16 records
the bench finding and the stream-engine fix.
/mode reports controller=running at the spawn, so the reference dump
raced grblHAL's init writes and captured the supervisor's motion-probe
values (motor_lock 0, step_freq 10000, y_mode at the module default)
instead of the resting state. boot_reference() now waits for the
controller's markers (step_freq/motor_lock/y_mode at their fixed values,
bounded 20 s, GRBL mode only) plus a 1 s settle before dumping, retakes
a saved reference that shows the pre-config state while the boot is
still fresh, and marks it otherwise. Tests cover the wait, its timeout,
the non-GRBL no-op, the pre-config recognition and the retake.
laser_lifecycle_test.py: the button toggle (press = Hold, press = Run;
the arming press is not a pause), lid and interlock cancel mid-job with
the return to the job start and no alarm, and lid_policy=hold.
Acceptance catalog: motion.button-hold-resume, motion.lid-cancel-home
(operator: travel job, lid open -> cancel message, banner, no alarm,
autonomous return, Idle at the start), laser.lid-cancel-mid-fire (live:
emission stops in hardware, cancelled, returned, armed=false, latch
locked, hardware button latch SET). covers name the switch and laser
sources explicitly.
LIGHTBURN.md: what the lid, Stop and the button now do; SAFETY.md: the
door policy and the button as a software layer; BRINGUP.md: item 16
records the whole parity change (host-proven, bench validation pending)
and items 4/12 point at it.
laser_lifecycle_test drives the controller's button wait through the
file-backed switch source (GF_SWITCH_FILE): a press with the lid closed
arms and nothing arms before it; the lid or the interlock loop opening
during the wait cancels the job (reason reported, alarm 3, never armed).
Acceptance catalog: laser.arm-wait-lid (operator kind - no press is
given, so nothing can fire) starts a laser job, has the operator open
the lid at the white-button prompt, and checks the cancel message,
alarm 3, armed=false, the kernel latch locked, no emission, and Idle
after $X. covers names glowforge_laser.c, glowforge_switches.c and
glowforge_switch_map.h explicitly.
LIGHTBURN.md: opening the lid or the interlock loop while the button is
lit cancels the job; a press with the lid open never arms.
The remaining bench diagnostics run from forgetest's #bench tab. The
tools that also run from a LAN host share scripts/bench/gfbench.py:
GF_HOST names a remote machine (host mode, sysfs through ssh, Grbl and
forgectrl over the LAN); unset, the tool runs on the board itself
(local mode, sysfs directly, everything on 127.0.0.1), which is how the
page runs them - with GF_HOST=127.0.0.1, the panel token in GF_TOKEN
and their data files under <data>/bench/ (FORGETEST_BENCH_DATA). The
helper also reads a machine setting from forgectrl, or from the settings
file on the board while forgectrl is stopped.
Ported: pwm_sweep / pwm_hold (scope = a takeover; the latch relocked,
the write refused if FIRE or LASER_ON reads active), pwm_stream_test
(PASS/FAIL exit), flow_characterize, flow_recheck_char,
flow_warm_validate and flow_matrix (takeovers: forgectrl owns the
thermal hardware, so the page's takeover replaces the tools' own
controller stop/restart, whose command line predated the supervisor;
results and logs in the bench data directory), flow_sustained,
fan_test, temp_calibrate (dry; watch bounded in seconds; the threshold
and the coolant conversion from the shared code), flow_escalate_drill
(cool_confirm_max_s shortened through forgectrl's settings for the
drill and restored; the setting's minimum is the default budget), and
live_fire_drills (<drill> [S] [F], all six drills, host from GF_HOST,
token from the board). flow_matrix joins the registry. What stays
unported cannot run against the machine at all: the two null-sink CI
harnesses and the .puls decoder.
Runner: a scope tool runs inside the takeover wrapper; the bench
environment above is passed to every tool. Tests: test_bench_registry
(registry <-> scripts/bench consistency, every ported tool builds its
command line, every script compiles, gfbench host/local modes) and the
server test (scope tool takeover, the environment reaching the tool).
Local mode smoke-run on the bench (temp_calibrate watch, setting, token)
from /tmp, removed after.
No catalog consequence: bench tools are not image components (dev-only
forgetest); the acceptance catalog is unchanged.
A component pin bump counted as a platform change: the layer content hash
in the platform identity covered the recipe carrying the SRCREV, the
platform is folded into every acceptance fingerprint, so every image
that carried any component update invalidated the whole catalog (dev
image 20260816191951: every test domain-changed after a one-line
forgectrl bump; the two manifests differ only in
platform.layers.meta-forgefirm). The component entry already identifies
the pinned source file by file; the pin double-counted it.
Component pins now live in <recipe>-pin.inc (SRCREV and the PV that
moves with it, nothing else) - forgectrl, grblhal-glowforge and
forgefirm-app here, the BSP components in meta-openglow - and
forgefirm-image-manifest.bbclass leaves *-pin.inc out of the layer
content (FORGEFIRM_MANIFEST_PIN_SUFFIX). Recipe bodies, patches, config
fragments, init scripts and third-party pins with no manifest entry stay
layer content; a pin written into a recipe body still hashes (the safe
direction). manifest-from-tree.py mirrors the rule and reads pins
through the recipe's requires; test_tree_manifest.py proves both
(pin bump: hash unchanged; recipe body or inline pin: changed).
Bitbake resolves the same SRCREV/PV for every pinned recipe.
Docs: ACCEPTANCE.md (what layer content is), kas/README.md (the pin
files in the push order), BRINGUP.md (the finding and the bench
consequence: the first image built with the pin files is itself a
platform change, so its campaign is a full one; pin bumps inherit
after it).
No catalog consequence: nothing in the image's behavior changes; the
change is to the acceptance identity computation, proven by the unit
tests and the CI lint on the tree manifest.
The lid lamp now has a resting policy in forgectrl (lid_lamp_idle,
default 236, asserted at start and at every spawn), so the baseline
expects it there instead of preserving whatever level a boot left, and
forgectrl.settings-bounds proves it: resting at the setting, 256 / -1 /
'bright' refused, a new level applied to the lamp at once, the cleared
key back to the default. Clearing a key goes through the query-string
form (an empty JSON value reads as no setting).
motion.liveness-probe adds the regression the bench needed: with every
axis masked (cnc/motor_lock=15, as a bench tool may leave it) forgectrl
is restarted and its fresh probe must read MOTION OK on the first try -
the probe unmasks the axes itself - and the controller comes up with the
mask cleared. Bench 2026-08-16: MOTION OK at p2p 2047/1341 against the
800 threshold, no ladder.
The baseline's settle no longer counts 'probe verified, spawn pending' as
settled (the post pass ran between the probe's own writes and the
controller's init writes and mis-flagged motor_lock/step_freq): it waits
for the controller to be running, with a bounded allowance for a respawn
backoff.
A baseline pass brackets every test and bench tool: before the run the
machine is verified against the fresh-boot idle state and anything off it
is restored; after the run - pass, fail, or abort - it is restored again.
Fixed items are the resting values the boot establishes (module defaults,
forgectrl's start-up writes, the GRBL controller's init writes) and
forgectrl's idle picture (controller running with motion verified, no
diagnostic, camera and cooling engines idle); preserved items (lid lamp
level, position counters, settings map, controller mode) are captured
before and handed back after. Deviations are leftovers: in the run pane,
in the result's evidence, and on the page - attributed to the previous run
when found before, to the run itself when found after.
forgetest takes a fresh-boot reference once per boot (within ten minutes
of boot, after the supervisor settles) as the session's resting lid-lamp
level and the check on the fixed values; the values were confirmed
against a fresh boot of the dev image on the bench (step_freq rests at
28160, the controller's default tick, not the probe's 10000).
Takeover runs capture the controller-owned kernel attributes on entry and
write them back before forgectrl restarts: the bench found the kernel
tests leaving motor_lock=15 behind, which masked the supervisor's
liveness probe - no motion by construction, a false driver-wedge verdict,
the rail-off ladder, and finally motion-fault. The takeover wrapper also
waits for the supervisor to settle on both sides (moved into baseline).
Catalog consequence: none beyond the runner; the tests' own drills are
unchanged.