Commit Graph
252 Commits
Author SHA1 Message Date
ScottW514 1f2c795d8c docs: build p30, image 20260903000529, the campaign's image
BRINGUP item 9: the deferred batch is on image 20260903000529; owed is the
flash, the fresh-boot baseline, and the full campaign, then the push and
the pin bumps. CAMPAIGN-LOG: the p30 build and its checks.
2026-09-02 20:13:31 -04:00
ScottW514 9711a7fa06 The audit's deferred findings: the checksum exclude, the resume-lead drill, the record
B-16: BB_SIGNATURE_LOCAL_DIRS_EXCLUDE in the distro conf names __pycache__
and .pytest_cache, so a workstation's bytecode caches never enter a
file:// checksum (proven in the build VM: a cache under the package leaves
the fetch task alone, a source change reruns it).

kernel.resume-lead: two phases behind one takeover at a 1 kHz tick. E, a
resume whose lead is longer than the data ends at end-of-data within a few
ticks (a lost end-of-data would show as 255 ms). L, a 1000-byte lead over
FIRE bits with the latch unlocked and the chain unarmed keeps the FIRE
line low through the lead and drives it from the waypoint byte on. The
bench proof for the module's K-4 and K-8 fixes; the catalog counts 55
tests, 0 uncovered.

BRINGUP items 9 and 11 and the CAMPAIGN-LOG entry record the batch and the
campaign rule: no campaign until every audit finding is on one image.
2026-09-02 20:03:22 -04:00
ScottW514 abccbf48e5 docs: build p29 on the pushed pins, image 20260902230436
CAMPAIGN-LOG: the push in CI order, the pin bumps, and build p29 with its
checks. BRINGUP item 9: the remediation is pushed, pinned, and built; owed
now is the flash, the fresh-boot baseline, and the full campaign on the
image, which the release gate asks for.
2026-09-02 19:15:52 -04:00
ScottW514 82c3596d6a BRINGUP: item 11, the B-16 residual and its actual plan 2026-09-02 18:59:07 -04:00
ScottW514 867136d77e BRINGUP: the Next work list runs 1 to 11, and the closing paragraph closes it 2026-09-02 18:55:25 -04:00
ScottW514 b99c92e047 BRINGUP: the audit's deferred findings as Next work item 11, with the plan for each 2026-09-02 18:51:03 -04:00
ScottW514 5cb18e64ab BRINGUP: the fielded bootloader and the watchdog path, as measured 2026-09-02 18:46:11 -04:00
ScottW514 380f67d666 docs: the forced kernel hang and the two measurements closed
CAMPAIGN-LOG: the forced hang on image 20260902144848 with its times,
the watchdog register read back, U-Boot's recovery branch (the purple
button), the recovery image on the lease, and the power cycle back; the
pad measurement dropped by decision. BRINGUP item 9: both measurements
closed; the pushes, the pins, one build and the campaign on that image
remain.
2026-09-02 18:30:38 -04:00
ScottW514 61f44011aa docs: the pooled bench session's second pass
CAMPAIGN-LOG: the attended set green on image 20260902144848, the three
defects the live runs and the takeover restarts found (the dwell-gap
latch rule, the log drops, the busy-start airflow) and their fixes, and
what is owed. BRINGUP item 9: both queues green; the measurements, the
pushes, the pins, one build, and the campaign on that image are what is
left.
2026-09-02 18:14:18 -04:00
ScottW514 774ae52b61 docs: the pooled bench session's first pass, and the PIC read pattern
CAMPAIGN-LOG: the unattended set on image 20260902144848, the six
harness and diagnostic defects it found and their fixes, the numbers,
and the board's state at the end of the pass. BRINGUP: item 9 names the
reset in the hang case and the session under way; the facts bank gains
the PIC read-pattern measurement; Next work item 10 is a pacing of PIC
reads in the kernel.
2026-09-02 17:02:33 -04:00
ScottW514 88ec984e28 Audit follow-through: runbook, bench tools, recipes, release tooling
BRINGUP describes the present: the 54-test catalog and its seven-test
always core, the tier counts, the shipped low-temperature gates, the
density floor ($35 = 10), the two local core commits, the ffboot env
write, the aa-offset route, the current bench image, and the bench
measurements the audit asks for (pooled into the next session). The
workstation shell notes and every em dash are gone.

forgetest: the takeover waits for the cloud client too (found by its
command line); the unauthenticated /boot probe names the endpoint's
parameter; the UI prose is American English. Recipes: forgetest
fetches its package directory and init script only and drops
__pycache__ at unpack; the dev image no longer re-adds forgectrl; the
release image's remove list drops the gfui-client the BSP no longer
has; the platform identity strips the kernel's local-version hash
from the modules directory name, so a re-patched kernel keeps its
fingerprints. grblhal restart is stop then start. release.sh --dev
packs the dev image. fixture.sh refuses a readable env file.

Bench tools: the live-fire drills measure the lid-IR baseline before
every run and point at the fire-watch thresholds the engine reads;
one thermistor conversion (gfbench.degc) serves every drill; the six
dated measurement records leave the tool directory; feeder.c names the
two sysfs writes its caller makes.

Host tests: forgetest 258 pass; the coverage lint reports no uncovered
path across 54 tests. Acceptance: forgectrl.auth covers the /boot
probe; update.* cover ffboot and the manifest identity; the runbook
and bench-tool changes have no catalog consequence.
2026-09-02 09:51:23 -04:00
ScottW514 3b21057dfe BRINGUP: the audit remediation follow-through is a Next work item 2026-09-02 08:22:03 -04:00
ScottW514 b132965e15 docs: the runbook's settings inventory and the bench page's help links are current
BRINGUP named nine cool_* tunables (there are thirty), a cool_fire_ir_delta
key nothing reads, and panel source files that no longer exist; the
inventory is the present one. The bench page's help popovers pointed at a
documentation host and paths that do not exist; they open the site.
2026-09-02 08:15:12 -04:00
ScottW514 ef2a8607c2 repos: the sources live in the openglow-org organization
The recipe URLs, the release and install URLs, the vendor check and the CI checkouts name openglow-org, and the grblHAL core fork is openglow-org/grblHAL-core. No catalog change is owed: the recipe edits move the meta-forgefirm content hash, which every test fingerprint folds in through the platform block, so the whole catalog re-runs on its own.
2026-09-01 19:44:47 -04:00
ScottW514 64f552fc28 laser power-good: the line characterized, the kernel-drill guard, the probe, the dev image's mmap and ctypes
The supply's power-good line is active high, static across HV enable and emission, and driven; the facts bank and CAMPAIGN-LOG carry the measurement and the item closes. The kernel-drill latch-unlock guard read the old inverted value as HV not good, a check that was vacuous and would refuse every run once the module reads the line correctly; it now uses the chain's own witnesses, the charge-pump watchdog and the engine state. pgood_probe.py watches the line beside the chain through the kernel readbacks and is registered on the bench page. The dev image lists python3-mmap and python3-ctypes again for the pad-level bench tools the python trim had left without them.
2026-09-01 18:48:47 -04:00
ScottW514 8a9c6a9062 laser: feed hold and resume in GRBL mode, the sender-change hold
Stream harness rule 21: a feed hold leaves no dark ground in either mode (lit into the hold, dark while held, lit from the first step out), with realtime and wait-state steps in the session runner. Lifecycle harness: the hold a sender change puts a running job into, the resume that re-arms a held job from the sender and from the button, a reset from a held job, and the resume after the grace closed the window in Hold. Live-fire drills: holdres (the pause as a corner in time, the re-arm after the grace); senderchg follows the hold. BRINGUP: the gapless-pause and sender-change items close, the facts bank gains the measured hold and resume behavior; CAMPAIGN-LOG records the proof and the bench runs. Acceptance: the pause-resume-lid-cancel text follows the behavior; the driver stays covered by src/**.
2026-09-01 18:03:45 -04:00
ScottW514 6a48cd3969 docs: the moved documents live on the documentation site
INSTALL.md, SERIAL.md, docs/COOLING.md, docs/LIGHTBURN.md,
docs/MOTION.md, docs/SAFETY.md, docs/UPDATE-SYSTEM.md, docs/VIDEO.md and
their images are pages on https://docs.forgefirm.org/ now. Every
reference in the README, BRINGUP, the kas config, the cold-build
workflow, forgetest, and the bench scripts points to the site page. The
README carries the beta banner. docs/ keeps BRINGUP.md and
CAMPAIGN-LOG.md.

No catalog consequence: the deleted files are documents, and the code
changes are comment and help-text repoints only.
2026-09-01 15:33:17 -04:00
ScottW514 8a93202c00 BRINGUP: the crash watch is done; item 6 is the head IRQ alone
No catalog consequence: a status-document edit.
2026-08-31 19:31:15 -04:00
ScottW514 c7c96f9cbe Pin forgectrl: the crash watch; its catalog case and the drill's latch bit
forgectrl 161686f adds the head-accelerometer crash watch (two tiers
on the LIS2HH12's interrupt generators, armed inside the laser's
armed window). The catalog grows cooling.crash-watch-plumbing - the
unarmed half of the watch provable without a button press: accel_watch
stays at watch through an unarmed session, three zeros read as the
three crash gates off, an out-of-range threshold is refused - and
_COOL_COVERS widens to src/accel.*. The armed-tier bench drill is a
BRINGUP next-work item.

The de-risk drill script's CTRL7 write moves from bit 0 (4D_IG1) to
bit 2 (LIR1), the latch the datasheet actually puts there; the drill's
findings did not depend on latching (a continuous gravity signal).
2026-08-31 18:47:49 -04:00
ScottW514 4a0338a03f bench+docs: IG threshold LSB is FS/256; factory HA* seed values recovered
The captured pulse headers carry the factory's IG programming: hunts
off, travels abort-only (HAar=133 at +/-4 g), the cut alert-only
(HAxr=132, HAyr=112), Z and idle never armed. The factory abort value
itself rules out an FS/128 LSB (4.16 g would sit over the measurable
range), and two Z-only bench windows bracket gravity between
thresholds 100 and 150, which only FS/256 explains. The drill script's
printed g conversion is corrected, and the stale motion-profile
reading of HAxr/HAyr/HAar as accel limits is corrected in the facts
bank.

No catalog consequence: a bench script's printed conversion and the
docs record; no shipped behavior changes.
2026-08-31 18:26:58 -04:00
ScottW514 61b2913e3a bench: crash-probe drill run, coexist proven, detector is forgectrl-only
The de-risk drill ran on the bench: the IG registers program and poll
over i2c-dev (I2C_SLAVE_FORCE) with st_accel bound, raw reads intact,
so the crash detector is forgectrl-only (BRINGUP item 6, CAMPAIGN-LOG
2026-08-31). The drill found the IG needs a running ODR: st_accel
leaves the part in power-down between one-shot reads. The script now
saves CTRL1, runs the window at 800 Hz, and restores it on exit; its
old ODR test checked the axis-enable bits instead of the ODR bits.

No catalog consequence: the change is a bench drill script, its bench
page text, and the docs record of the drill; no shipped behavior
changes.
2026-08-31 18:21:08 -04:00
ScottW514 765521455d bench: head-accel crash-detector de-risk drill (item 6, first step)
accel_crash_probe.py arms the head LIS2HH12's on-chip interrupt
generator (IG_CFG1/IG_THS/IG_DUR1) and polls the latched IG_SRC1 for a
strike, reporting the axes and raw magnitude. It settles the bench fact
the crash detector rides on: coexist mode reaches the IG registers over
i2c-dev with I2C_SLAVE_FORCE while st_accel stays bound, so it proves
whether the detector can be forgectrl-only with the liveness path
untouched, or whether the accel must move under glowforge.ko. It touches
only the IG registers (0x30-0x35) plus the CTRL7 latch bit, never the
full scale, so st_accel's raw scaling is undisturbed; no emission, no
commanded motion by default.

Registered on the bench page (dry, board) and in the bench README.
BRINGUP item 6 now stages the drill as the committed first step, with
the readout path, per-state thresholds and the two-tier wiring owed
after it. Tooling only: no shipped component source changed, so no
acceptance-catalog consequence (the detector feature gets its case when
it is built); the bench registry test and coverage lint pass.
2026-08-31 17:56:53 -04:00
ScottW514 18104a0e51 BRINGUP: merge the head crash detector and head IRQ into one item
A firmware decode of the head MCU (recorded in CAMPAIGN-LOG) shows the
factory head crash detector and the head IRQ accel_irq source are one
mechanism: the head accelerometer (LIS2HH12) has an on-chip interrupt
generator the factory arms per job from the HA* header tags (bit-exact
onto its registers) and reads by polling IG_SRC1; its INT wires to the
head MCU and surfaces as reg 0x05 b1 behind HEAD_IRQ, which is
level-driven off the MCU's latched reg 0x02 and dormant until the SoC
arms an edge in reg 0x03/0x04.

Facts bank: add "The head MCU flag register and HEAD_IRQ", "The head
accelerometer", "Beam detect in the head MCU" (correcting the thinner
entry: reg 0x05 has a fourth input and a b7 processed verdict we do not
expose; beam_detect_digital is the raw comparator, not the verdict).
Next work: merge items 6 and 8, renumber 12 to 11, repoint the trailer.
CAMPAIGN-LOG: dated entry recording the decode. Docs only.
2026-08-31 17:43:43 -04:00
ScottW514 0ee48d76a7 BRINGUP: move hardware facts to the facts bank, keep Next work to owed work
Facts bank: add the head-IRQ/beam-detect entry and the coolant-ADC
offset entry; point the SDIO CRC note at the closed watch record.
Next work: trim items 6-10 to the open work with facts-bank citations,
remove the stale bench-page sentence from item 3, and retitle item 10
to the second-machine re-measure (the sensor-line scope work is
dropped by decision). Docs only, no catalog consequence.
2026-08-31 17:04:36 -04:00
ScottW514 a3127c29cd Retire next-work item 3: the debug-kernel drills passed
Load/unload under DEBUG_MUTEXES (three clean cycles) and the forced
-EPROBE_DEFER unwind both passed on the debug-kernel image, no lock
splat, machine recovered (CAMPAIGN-LOG has the run). BRINGUP: the item
closes, items 4 and up move down one.
2026-08-31 16:43:54 -04:00
ScottW514 298abf8a12 Item 3: fold the debug kernel into the closing build
kas/forgefirm-glowforge-debug.yml builds one dev image on the debug
kernel (FORGEFIRM_KERNEL_DEBUG=1, tagged dev-debug) beside the closing
release and dev images; the debug options never touch either.
scripts/bench/debug_kernel_drills.py runs the two drills (three
load/unload cycles under DEBUG_MUTEXES, a forced -EPROBE_DEFER unwind),
each read against dmesg for lock splats, refusing on a non-debug kernel
or a non-idle machine; it is registered as a board bench tool. BRINGUP
item 3 names the mechanism and stays remaining work (run it on the
closing burn); the site's Build page documents the variant.
2026-08-31 15:54:28 -04:00
ScottW514 8ba998c3ef Retire next-work item 3: the K-11 badly-answering head is proven
A head reset (its own 0xc9<-0x5a register) made the present head NAK
through its reboot; the witness reads errored (K-11 propagation) with no
spoofed positive, and the head recovered on a driver rebind
(CAMPAIGN-LOG has the drill). BRINGUP: the last physical-evidence
negative closes, items 4 and up move down one.
2026-08-31 15:43:26 -04:00
ScottW514 94f7c23ade Item 3: the failed-head-capture negative is proven; the fault note drops
A busy capture node made the real head-image path fail with the measure
laser armed; the laser ended at 0 and the camera engine recovered
(CAMPAIGN-LOG has the drill). The STATE_FAULT-recovery note leaves the
item by operator decision. What remains is the K-11 case, one bench
slot.
2026-08-31 15:32:33 -04:00
ScottW514 8d68cee5bf docs: correct the DRV8825 reset-line fact in the wedge entry
The nRESET and nSLEEP lines are not strapped: glowforge.ko drives them
(reset-gpio gpio3 18, sleep-gpio gpio3 16), confirmed by pad traces to
U20/U21/U22 pins 16 and 17. They move only as a pair in every
enable/disable cycle, together with the rail, so the reset pulse is part
of every recovery attempt and has never shortened the ladder. A logic
reset alone does not clear the wedge.
2026-08-31 15:23:00 -04:00
ScottW514 99902a1579 Retire next-work item 3: the shared-services polish is closed as a set
Diagnostics run as an engine mode behind cool_diag_take/release, the
HTTP surface carries its accept caps with bounded camera setup
children, and the busy-state arbitration is declined with its reasoning
(CAMPAIGN-LOG has the proof runs and the two cross-check lessons the
queue taught). BRINGUP: the item closed, items 4 and up move down one.
2026-08-31 15:13:08 -04:00
ScottW514 33461556c3 Retire next-work item 6: the SDIO watch is clean
97 boots across 16 days of persisted kernel logs carry zero SDIO CRC
failures against the pre-fix baseline of one in 49 minutes; the
factory-exact uSDHC pads hold and the 25 MHz cap stays unneeded.
Items 7 and up move down one.
2026-08-31 13:56:10 -04:00
ScottW514 4e78ef03d7 BRINGUP: trim the top of next work
Limit-switch homing is its one sentence. Cameras holds only the
untested 8 MP sensor's questions; the emulator homing-image smoke moves
to the acceptance follow-through, where the tool work lives. The cloud
item closes as a status recitation: its facts live in CLOUD.md, and the
one open question rides the 8 MP first light. Items 4 and up move down
one.
2026-08-31 13:52:39 -04:00
ScottW514 fe977c0dcc Retire next-work item 1: the fire watch is armed on the bench
The factory-shaped watch is implemented, host-tested and bench-proven
with the lamp as the flame stand-in (CAMPAIGN-LOG has the run, the
fault-class mapping and the recorded interpretation). BRINGUP: the item
closed, items 2 to 18 are now 1 to 17, the references follow, and the
facts bank reads the armed posture. Pin forgectrl for its doc fix.
2026-08-31 13:48:53 -04:00
ScottW514 a3d921b7ee Retire next-work item 1: the TEC drive is on the bench
TEC handling is implemented, host-tested and proven at the GPIO
(CAMPAIGN-LOG has the run and the CMet/CMdt correction: readings, not
setpoints; the defaults are chosen). BRINGUP: the item closed, items 2
to 19 are now 1 to 18, the five cross-references follow.
2026-08-31 12:59:10 -04:00
ScottW514 97b10683c2 Retire next-work item 1: the low-temperature gates are on the bench
The coolant floor and the warm-up gate are implemented, host-tested and
bench-proven (CAMPAIGN-LOG has both runs, the heater-slug lesson
included). BRINGUP: item 1 closed, items 2 to 20 are now 1 to 19, the
six cross-references follow, and the facts bank carries the slug fact.
2026-08-31 12:35:37 -04:00
ScottW514 85d266e572 Retire next-work item 1: the gap question is answered from the chain
The button latch is SET by lid-open or the SoC lock and RESET by the
button only; the charge-pump watchdog feeds HV_ENABLE, not the latch.
A kernel-run gap inside an armed job drops HV_ENABLE and leaves the
latch alone, and the next run has HV_ENABLE back before its first step.
No keepalive.

laser.emission-witness carries a G4 P2 between the second and third
sides of its square and checks cnc/button_latch clear in every armed
sample, HV_ENABLE dropped across the dwell and back with emission after
it; the operator confirms all four sides.

BRINGUP: item 1 removed, items 2 to 21 are now 1 to 20, the five
cross-references follow, the flow-band sentence is in the facts bank.
CAMPAIGN-LOG: the answer, the retired item, and the unattended set run
green on the hot-deployed board (campaign c-20260831151846).
2026-08-31 11:37:53 -04:00
ScottW514 a73ee9c6bf docs: lens shading resolved from the factory rootfs
The factory image carries a register loader that nothing calls, the app
references an apply script the rootfs does not have, and the OV5648
driver has no regs attribute. No shipped machine applies a per-unit
shading table. BRINGUP item 6 drops the claim; CAMPAIGN-LOG has the
search.
2026-08-31 10:47:31 -04:00
ScottW514 c01699ee94 docs: the 2026-08-31 pass over the small items
CAMPAIGN-LOG: the rail policy, the /cool/status changes, the armed-kill
placement, the image trims with the 20260831130656 manifest, the lid IR
lamp step, the SDIO count, the lens-shading search, the debug-kernel
assessment, and the bench cleanup; the four closed items in the
superseded notes.

BRINGUP: item 18 closed (the trims landed), items 19 to 22 are now 18 to
21; the release rootfs size fact reads the measured 89 MiB.
2026-08-31 10:19:20 -04:00
ScottW514 b334c4cc33 image: drop the python3 meta-package and the GnuTLS stack; pin forgectrl and grblHAL
The release rootfs carried python3-modules (tkinter, idle, 2to3, pydoc,
ensurepip, venv, asyncio, multiprocessing, xmlrpc) through the python3
meta-package, and libgnutls30, nettle, libgmp10, libunistring5 and
libtasn1 through libmicrohttpd (https) and ulfius (GnuTLS). Nothing on
the image uses either. Each Python recipe declares the module packages it
imports; forgetest declares its own, so the dev image carries no module
the release image lacks.

Pins: forgectrl 0e907f7db54b7a4c90b660f198d49e5c66b667b5 (armed shown from a
fresh report only, zero smoke phase for a dark session), grblhal-glowforge
fa9ed7834faab6f48367dc1ca5a5109b474f788d (rail enable only standalone).

BRINGUP: the lid IR lamp response measured over the full range; no camera
register file under /data; the rail policy and the cool status items
closed; laser.armed-kill stays in its domain; the debug-kernel drill
constraints.

Platform change (layer content): the full campaign is owed on the built
image.
2026-08-31 09:04:37 -04:00
ScottW514 431f0f29fa Close the laser power model item; add the side-by-side chooser
The corner rolloff's right value is per machine (this bench settled at
1.5 against the shipped default of 2), so the commissioning item gains
a side-by-side chooser: the same corner-heavy pattern cut at several
settings, the operator picks the best by eye, Apply writes the winner -
with the dose-curve recorder as the first piece of that tool family and
its template. With that, everything the laser power model item held is
answered or homed: its conclusions live in the Laser control section
and the facts bank, its dated record in the CAMPAIGN-LOG, and the
tree-root working file is deleted per its own charter. Next work item
16 closes; the later items renumber down by one.
2026-08-30 22:21:37 -04:00
ScottW514 58cad9a8d8 Prove the corner rolloff; document the one-press recorder
The stream harness gains rule 20: under M4 with the curve in force, the
accelerate-in head of a line renders less density at the default gamma
of 2 than at gamma 1 (0.317 against 0.537 on the host grid) while the
cruise middle renders identically - the exponent shapes only the
velocity-scaled rolloff, never the programmed level. The panel-serves
covers widen to the whole recorder (src/curverec.*). BRINGUP describes
the rolloff and the one-press recorder; the MOTION table gains
laser_corner_gamma; the panel help explains the knob.
2026-08-30 21:48:32 -04:00
ScottW514 0b941fd743 Prove the dose curve and the recorder; document S-means-light
The stream harness gains rule 19: with the bench-default curve in force
a ladder of S rungs renders the curve's densities exactly (half light
lands near 80 percent density), monotonic, floored and ceiled by
$35/$36; every other session pins laser_dose_curve = off so its
S-to-level arithmetic stays exact, and the arm-report checks carry the
curve name. The lifecycle harness asserts the published state file
names the curve in force. The catalog's forgectrl.panel-serves asserts
the curve field in the grbl report, /curve/status and the ladder
G-code, and its covers name the recorder.

BRINGUP describes S-commands-light through the measured curve and the
owner recorder; the MOTION table gains laser_dose_curve; LIGHTBURN
tells the operator power now means light and how to record their own
tube's curve from the panel.
2026-08-30 20:19:24 -04:00
ScottW514 d612c0099a Prove the density-only model; record the rasters and the decision
The stream harness keeps the analog rendering as the host-test
conservatism reference (rule 13's mask, the duty ladders) and drops the
M101 switch sessions; rule 18 stays as the derived-floor proof, now
satisfied from boot by the precompute. The lifecycle harness's
state-files scenario asserts the derived floor is in $$ before any arm.
The catalog's laser.power-model-switch goes and laser.power-floor reads
the one floor key with no M-code needed. The mswitch drill goes; the
m4corner drill becomes a single density pass; the dpatch drill returns
to density only.

The CAMPAIGN-LOG records the first rasters (254 and 508 DPI grayscale
wedges: tonality held to ~14 pulse slots per pixel, no dither artifact,
one benign stale-verdict suppression under CPU starvation) and the
decision that ends the analog mode - the strike transient fires a spot
at every beam-on, and the finish comparison found no advantage. BRINGUP,
LIGHTBURN, MOTION and SAFETY describe the density-only present.
2026-08-30 19:41:50 -04:00
ScottW514 917b4bb55e Prove the controller's published state files
The lifecycle harness gains the state-files scenario: with GF_STATE_DIR
at the session workdir, grbl.settings carries the $$ view and follows
the derived floor through an M101 switch and its M2 revert, and
grbl.state follows the sender connection (a reconnect bumps the
generation), the armed window and the dose model, with ts_mono
advancing. The panel-serves catalog test asserts the /status grbl block
in GRBL mode with a live controller (fresh age, state, sender, laser,
modals) and GET /grbl/settings, and its covers name the publisher and
the serial layer; the glowforge_status.c covers entry selects nothing
until the grblHAL pin moves past the commit that adds the file. The
CAMPAIGN-LOG records the build and its proof; BRINGUP describes the
mechanism.
2026-08-30 15:59:56 -04:00
ScottW514 3025996c86 Prove the M101 dose-model switch; record the judged dose curves
The stream harness gains rules 18 to 21: the floor is derived from the
selected model's config key at the arm and a typed $35 is overwritten;
M101 switches the rendering exactly at the boundary in both directions
with no continuous FIRE at full duty across it; a refused switch (the
spindle on) leaves the stream unchanged, and the harness resyncs with
an empty line because the core skips G-code after an error until the
sender resyncs; M2 reverts a program-scoped switch and Q1 holds. The
analog sessions pin laser_floor_analog at the density floor so the
existing duty expectations stand, and the density ladder's unfloored
run moves from a chained $35 write to the laser_floor_density key.

The catalog's laser.power-floor becomes model-aware: it reads the
configured model and the floor keys from forgectrl, switches to the
configured model with M101 so the derivation runs without a fire, and
expects $35 to be that model's floor. The new laser.power-model-switch
switches to each model with the spindle off, checks the reported
message and $35 after each switch, and checks the M2 revert. The new
mswitch bench drill runs the switch on the machine in one armed run.

Docs follow: BRINGUP's Laser control section describes the switch, the
derived floors and the measured dose response of both models; the
MOTION settings table gains the five keys; LIGHTBURN gains a Power
models section and drops the stale 30 percent floor advice; SAFETY
names the switch's refusal rule; the CAMPAIGN-LOG records the judged
depth-witness runs of 2026-08-30 and the switch's host and bench proof.
2026-08-30 15:08:34 -04:00
ScottW514 cd00b0d16f Warm the loop by the mixed bulk; record the flow check to the heater's ceiling
flow_warm_validate.py warms in rounds (the heater at 50 percent for three
minutes, off, 45 s of circulation, the two sensors' mean read) and judges
the target on that mixed bulk, not on the upstream sensor beside the
heater, which reached any target within two minutes while the bulk had
barely moved. Run with a 28 C target the loop plateaus at 27.2 C in a
20 C room; six checks at 26.2 to 27.2 C read every verdict right, the flow
band under 11.9 C and the no-flow band over 18.0 C against the 14.4 C
limit. CAMPAIGN-LOG records the run; BRINGUP item 1 keeps only the
button-latch check, the flow check's bands holding from 19 to 27 C.

No catalog consequence: a bench tool and documentation.
2026-08-29 19:37:26 -04:00
ScottW514 9bfdba44c8 Record the calibrate tool's accepted run on image 20260829220329
CAMPAIGN-LOG: aa-offset-calibrate with its 3 s at 8 Hz sampling reads
16.2 counts with a spread of 4.5 over six edges, the value already
applied; the compensation's whole path stands on the bench. BRINGUP item
21 keeps only a second machine's value and the lit-tube toggling.

No catalog consequence: documentation.
2026-08-29 18:16:07 -04:00
ScottW514 e32c86fb10 Pin forgectrl 42cdb71; add the coolant offset check; record the compensation on the bench
The pin carries the calibrate tool's sampling fix (3 s at 8 Hz a side).
aa_offset_check.py proves the correction on a machine: M8 brings the fans
to the run profile, dark, while the raw coolant counts, /status and the
engine's readings are averaged before, during and after; it turns the
flow check off for its session and restores it. On the bench page as
aa-offset-check. CAMPAIGN-LOG records the tool's first run, the applied
value (16 counts) and the proof: the readings held within 0.1 C under
the run profile where they dropped 1.0 C uncorrected. BRINGUP item 21
names what remains.

No catalog consequence: a bench tool and records.
2026-08-29 18:02:46 -04:00
ScottW514 8831d9b20e Pin forgectrl f9b4893: the air-assist ground shift off the coolant readings
The pin carries the compensation (cool_aa_offset_counts, the
aa-offset-calibrate diagnostic, the panel's Apply); verified with
bitbake -c fetch. The catalog gains cooling.aa-offset-calibrate, which
runs the tool and checks its recommendation and spread.

scripts/bench/offset_probe.py is the differential probe that found the
source: one actuator switched at a time with both sensors at 25 Hz
(survey), the air-assist duty ladder, the gantry jogging under the fan,
and an armed dark dwell. CAMPAIGN-LOG records the four probes and the
result; BRINGUP item 21 names the setting and the calibrate as what
remains on this machine, and item 23 opens the initial commissioning
procedure.

No catalog consequence beyond the new case: a bench tool and records.
2026-08-29 17:36:02 -04:00
ScottW514 61b68c387c Add cooling.flow-under-load: the flow check with the tube lit through its window
A live catalog case: two 30 x 4 mm fills at full power on the press, the
window held open until the engine's flow verdict lands in the forgectrl
log, then M2 and the head brought back. PASS needs a verified line with
the laser's share on it (at least 0.3 C: the window and the fire
overlapped) and the judged rise at least 1 C under cool_flow_rise; an arm
refused by a gate names the gate. Passed on image 20260829190323
(heater rise 11.9 C judged, laser 0.6 off 12.5).

CAMPAIGN-LOG records the run and the day's two air-assist gate holds (a
bench connection, reseated); BRINGUP item 21 names the case.

Catalog: the case covers forgectrl src/cool.* and its neighbors; a new
test, so the manifest's coverage widens rather than moves.
2026-08-29 16:39:03 -04:00