T
ScottW514 97b10683c2 Retire next-work item 1: the low-temperature gates are on the bench
The coolant floor and the warm-up gate are implemented, host-tested and
bench-proven (CAMPAIGN-LOG has both runs, the heater-slug lesson
included). BRINGUP: item 1 closed, items 2 to 20 are now 1 to 19, the
six cross-references follow, and the facts bank carries the slug fact.
2026-08-31 12:35:37 -04:00

94 KiB
Raw Blame History

ForgeFIRM bring-up status & cold-start runbook

Last updated: 2026-08-26.

This is the present state of the machine, the bench runbook, the measured hardware facts, and the authoritative list of open work. The dated record — bench campaigns, drills, scope gates, the audit remediation, the acceptance campaigns — is CAMPAIGN-LOG.md; come here for what is true now, go there for how it was proven.

Read together with:

Document What it settles
kernel-module-glowforge/UAPI.md the pulse-stream feeder contract, sysfs attributes, sensor conversions
forgectrl/docs/SERVICES.md the machine-services contract: switch map, hardware ownership, cooling channels, mode supervision, pulse-device ownership, logging
docs/SAFETY.md the hardware safing chain, decoded
docs/VIDEO.md the cameras as users meet them: endpoints, delivered geometry, and what the sensors can do that ForgeFIRM does not send
docs/LIGHTBURN.md, docs/UPDATE-SYSTEM.md, INSTALL.md sender setup, A/B update system, install
docs.forgefirm.org/developers build, release flow, tests, the bench runbook
python3-gfhardware/forgefirm-app/docs/CLOUD.md cloud mode, including its own open items

Where the project stands

The machine works, in both controller modes, and the whole stack is hardware-validated.

  • Platform bring-up: complete and hardware-verified. SDMA + EPIT pulse playback out of a reserved DMA pool, live-fed during a run; laser PWM at 39.98 kHz; CONFIG_PREEMPT=y; both OV5648 cameras on the mainline imx-media pipeline with VPU JPEG encode; A/B slot install, signed .fw releases and factory restore.
  • GRBL mode cuts real jobs. grblHAL (the stock core plus one local fix, and the ForgeFIRM driver) speaks Grbl 1.1f over TCP:23; LightBurn drives motion, the laser and the camera stream. First light landed 2026-08-11.
  • Cloud mode runs the factory experience end to end, deliberately kept and maintained: sign-in, camera homing, prints, pause/resume, cancel.
  • forgectrl is the one machine-services daemon behind both modes — cooling engine, controller supervision, pulse-device broker, motion-liveness gate, cameras, telemetry, settings, diagnostics, logging, updates, web panel.
  • Laser safety is hardware-first and bench-proven. The chain (LID_SW1 & LID_SW2 & INTERLOCK & HV_OK & supplies-OK → OK_2_FIRE, FIRE & OK_2_FIRE → LASER_ON) gates the beam; the kernel latch, the operator-armed window, the coolant fire gates and the dead-man chain sit on top. GATE A (uncommanded energy) and GATE B (control surface + release) are both closed.
  • Lid, interlock and button behave like the factory firmware in both modes (cancel-and-return on a lid or interlock open, button pause/resume), bench-validated 2026-08-17.
  • Releases are gated by the acceptance tool (forgetest, dev image only): a 46-test catalog, domain-scoped inheritance, an always-required safety core, a bench actuator that works the lid, the interlock and the button so most of the operator's part runs unattended, and a release gate that reads the exported artifact. The latest full campaign, on dev image 20260824230512, satisfied 45 of 45 from nothing in 27 minutes (36 tests unattended) and authorizes a release; no release is cut yet.

Current bench state: dev image 20260824230512, the board resting on the SD dev image (eMMC slot 1 = factory 2024, slot 2 = ForgeFIRM v0.1.0, archives in /data/forgefirm/archive).

The bench

  • Board: SSH root@<machine-ip> (dev images permit passwordless root login). The bench machine is a Basic/Plus (the control board is common to Basic/Plus/Pro). Dev image (forgefirm-image-dev) on SD; BusyBox userland + python3 + gdb/strace. Serial console on ttymxc0 available at the bench.
  • Deploying kernels: re-burn the SD with the freshly built forgefirm-image-dev-glowforge.rootfs.wic.gz (deploy dir below). Why this works: U-Boot (in eMMC boot0) reads the saved env at eMMC user-area 0x80000, which selects the boot device (bench board: mmcdev=0 mmcroot=/dev/mmcblk1p1 = SD), then loads /boot/uEnv.txt and /boot/zImage from that rootfs partition — so the kernel always comes from the burned SD. Full map: "eMMC boot & recovery architecture" in the facts bank below. Module-only changes hot-swap: scp glowforge.ko over /lib/modules/<kver>/extras/, then rmmod glowforge && modprobe glowforge. NOTE: a module reload turns off the lid LED (relight via /sys/class/leds/lid_led*/target) and resets the analog configuration, and the first liveness probe after a reload can read NO MOTION until the ladder re-probes.
  • Module hot-swap vs kernel re-stamps: the hot-swap only loads if the module was built against the FLASHED kernel's patch state. Any edit under the kernel recipe's overlay (e.g. glowforge.dts) re-stamps CONFIG_LOCALVERSION_AUTO — and the stamp does NOT reproduce by reverting the edit (the kernel patch tree is a fresh git commit each do_patch, not sstate-restored), so after any overlay edit the module can only ship with a full image flash. Kernel/BSP changes therefore ride one image flash, batched, and a .ko or overlay change is validated on the image that ships it, never hot-swapped onto a board about to be reflashed.
  • Build host: a Linux build environment (a WSL2 distro works) holding the forgefirm + meta-openglow sibling checkout (the site, Developers, "Build"); the ForgeFIRM source repos are fetched by pinned SRCREV. Build: cd forgefirm && kas shell kas/forgefirm-glowforge.yml -c 'bitbake forgefirm-image forgefirm-image-dev'. Artifacts: forgefirm/build/tmp/deploy/images/glowforge/.
  • fwup lab (host): a host directory (<fwup-lab>) holds host-built fwup-0.14.2 (factory-era) and fwup-v1.16.0 under bin/ and the DEV signing keypair devkeys/fwup-key.{priv,pub} (fwup-key-raw.pub = raw 32-byte form — what fwup 0.14.2 expects; 1.x reads both). Cross-version compatibility is proven both ways (modern-packed signed archives apply with 0.14.2; modern fwup verifies and applies the factory .fw — signer key 2017-05-001.pub). The production release key is held offline by the operator — the installer embeds its public key, so releases sign with that key only. Pack releases with scripts/mkfw.sh; the full pipeline is scripts/release.sh, invoked as: FWUP=<fwup-lab>/bin/fwup-v1.16.0 FWUP_COMPAT=<fwup-lab>/bin/fwup-0.14.2 FORGEFIRM_DEV_KEY=<fwup-lab>/devkeys/fwup-key.priv FORGEFIRM_SIGNING_KEY=<release key> RELEASE_STAGING_DIR=<dir> ./scripts/release.sh <version> (the publish step needs an authenticated gh; release.sh prints the exact command).
  • Bench hygiene: stage test files in /tmp; anything that must survive a reboot goes in /data/bench-scratch/ and that directory is deleted whole at the end of the session. Bench tools worth keeping live in forgefirm/scripts/bench/ and ship on the dev image under /usr/share/forgetest/bench/.
  • Shell gotchas (cost real time): PowerShell mangles embedded double quotes in git-commit here-strings (avoid " in messages); wsl -- bash -c '...' eats $VAR expansions (use script files run via PowerShell, not Git Bash, which MSYS-mangles /mnt/c paths).

Running the controller (grblHAL-glowforge on the board)

Source: the grblHAL-glowforge sibling repo — the canonical grblHAL driver repo (github.com/ScottW514/grblHAL-glowforge, branch main): core as a submodule at src/grbl (→ ScottW514/core fork, branch forgefirm = upstream master plus one local commit, the step_us_min buffer sizing that keeps a fortified build from aborting in settings_init; the settings-write crash fix merged upstream 2026-08-04 as grblHAL/core PR #999). driver.c implements the HAL; machine constants live in src/boards/glowforge.h.

The controller is spawned and supervised by forgectrl: the supervisor starts the controller selected by controller_mode (grbl | cloud) as a direct child, respawns it on a crash (after safing the machine), and switches modes live via POST /mode / the Status-tab selector. The grblhal and gfcloud init scripts defer to it (they remain as manual emergency levers, routed through POST /controller/stop|start). The pulse device arrives as a broker-inherited fd (GF_PULSE_FD) — the device never closes across mode switches, homing handovers or respawns, so the 40 V rail never cycles as a side effect — and the supervisor verifies physical motion (head-accelerometer liveness probe) before the first controller spawn of each session.

Architecture: a wall-paced producer thread runs the core stepper ISR against a virtual step clock (1000× machine tick) and maps step events to pulse bytes; a SCHED_FIFO shipper feeds /dev/glowforge through a bounded queue; a recursive core mutex stands in for interrupt masking. GFSINK unset = null-sink mode (full engine, no hardware I/O — host testing and CI).

  1. Build: bash <repo>/forgefirm/scripts/bench/build-glowforge.sh in the build environment (from Windows, launch it through the WSL distro from PowerShell — Git Bash mangles /mnt/c paths). Produces build-arm/grblHAL_glowforge in the checkout (-O1 -g; machine constants force-included into the core: 53.333 µsteps/mm XY @ ×8, 2.832 half-steps/mm Z, 0.417" Z travel, 12000 mm/min max, 700/590 mm/s² accel — factory-derived, see puls_profile.py).
  2. Deploy: move the new binary over /usr/bin/grblHAL_glowforge (mv replaces the inode, so the running instance is untouched), then kill the running controller — the supervisor respawns it on the new binary within about a second.
  3. Standalone start (bench/debug only — requires forgectrl stopped, since the broker's exclusive hold on /dev/glowforge makes any self-open fail EBUSY): cd /data && GFSINK=/dev/glowforge grblHAL_glowforge -p 23 -e /data/EEPROM-glowforge.DAT. Env knobs: GFSINK_RATE (machine tick, default 28160 Hz = factory travel tick), GFSINK_DEPTH_MS (queue depth = feed-hold latency, default 200). Standalone, the driver opens the device itself and every takeover runs the rail_settle_s off-period; under the broker it inherits the fd and skips the settle (the rail never dropped). The driver applies the full analog machine config at init either way (×8 modes, decay 1, motor_lock 8, laser latched, PIC hold currents) and swaps PIC run/hold currents around motion. Each motion run logs a producer-stats line (callbacks, µs/call, max-behind, clamped) — clamped should stay 0.
  4. Connect LightBurn/UGS to <machine-ip>:23, or jog raw: $J=G91X40F1200. ^X mid-motion aborts via kernel cnc/stop (controlled decel) and raises an alarm; TCP disconnects never kill the process (the dead-man fd stays held).

Spindle $-settings take effect at controller start. The core precomputes the S -> duty mapping once, when the spindle is enabled, and a settings write does not re-run it: $35=16 persists to the eeprom immediately and $$ reports it immediately, but the mapping in force is still the one loaded at start until the controller restarts (a mode switch, a POST /controller/stop + start, or a boot). Verified host-side: after a runtime $35=0 the shipped duties stay floored.

Stored $-settings beat freshly baked defaults — after changing GLOWFORGE_DEFAULTS values, run $RST=$ once on the board (settings persist in the eeprom file in /data).

Protocol-loop pacing is fd-blocking. serial_wait() drains TX then ppoll()s the listen/client fds with a state-dependent timeout: idle and alarm at 10 ms (1 ms while a delay callback is pending), motion at 200 µs, and the parked states — a completed feed hold, a parked door ajar or closed, and sleep — at the coarse idle poll, while the motion sub-phases (Hold_Pending decel, Parking_Retracting/Resuming) keep the tight pace. Measured on the bench: idle 2.7 %, active move 34–35 %, parked 2.7–3.0 %. Client RX is armed only while the ring has a full read's worth of room, so a flow-control-violating sender is paced, not spun on.

Laser control (GRBL mode)

The real spindle lives in grblHAL-glowforge/src/glowforge_laser.c. Per-segment spindle updates (the core's laser-mode path, on the stepper producer thread at exact virtual-tick positions) map power and fire transitions onto the pulse-byte grid via gf_stream_laser(), and the shipper emits them: a power byte (0x80 | 7-bit duty, raw PWMSAR counts, 127 = 100 %) inserted ahead of the first tick byte it covers, FIRE as bit 4 OR'd into tick bytes. The spindle PWM is precomputed to a period of exactly 127, so computed values ARE power bytes ($30 default 1000 → S1000 = 127).

Dose model: density, the only one. The shipper renders the per-segment value the core computes by pinning the duty at full and modulating the FIRE bit on a base period of laser_pulse_ticks (default 20 = 710 us at 28160 Hz, the factory's ~1.43 kHz) whose on-count is dithered between adjacent integers with the remainder carried, so densities finer than one tick per period average out. Every pulse is full-power, so no commanded level can land in the tube's dead band, and no beam-on ever dwells: the analog alternative (duty as the power byte, continuous FIRE) fires the strike transient as a visible spot at every turn-on whatever the power, and was removed as a product mode for it - the rendering survives only as the host harness's conservatism reference, selectable solely in the null-sink build. laser_pulse_min_ticks (default 3 = 106 us) is the shortest pulse the model emits: below it a period is skipped and its debt carried, so a faint level arrives as fewer full-width pulses instead of stubs the supply cannot strike - measured on the bench, a 36 us stub draws no discharge at all, and the factory never emits below one of its 100 us ticks. The debt is conserved, so the average density is unchanged: at level 2 the stream goes from 444 one-tick bursts to 147 three-tick bursts, same density to four decimals. Structurally the model is a mask on the core's fire state and never a source of one, so emission stays exactly where the core commanded it.

The floor is derived, never typed. laser_floor_density (default 10, the lowest density that still marks, putting a commanded 1 % at 10.2 % density) is loaded into $35 at every spindle precompute - boot included - in RAM only: the stored $35 is never written, $$ reports the floor in force, and a $35 typed by a sender is overwritten on the spot. The arm report names it (laser armed (density, floor 10 %)), and a floor of 0 is honored with a note (the ladders run that way). The cooling report carries the model with the job state.

S commands light, through the measured curve. The tube's output is convex in pulse density (this bench, 2026-08-30, by the head thermopile, the tube current and the operator's eye: 80 % density delivers about half the CW light, 60 % a third, 45 % a fifth, 30 % a fourteenth - the same physics behind the factory's 18.9 to 79.5 % mapping with Full Power kept apart). So the driver maps the commanded fraction through the measured curve's inverse onto the density that delivers it: laser_dose_curve in the machine config holds density:light percent pairs, ships with the bench-measured default compiled in, accepts off for the identity, falls back loudly on a bad value, and is reloaded at every precompute with the arm naming it (laser armed (density, floor 10 %, curve bench-default)). $35/$36 still floor and ceil the result. Under M4 the curve makes delivered light exactly proportional to velocity - and heat still accumulates where the head slows, so corners over-burned on the bench; laser_corner_gamma (default 2, range 0.25 to 4) bends the rolloff to light proportional to (v/v_programmed)^gamma, starving the slow spots the way the raw convex mapping used to by accident, while the programmed level at speed stays exactly the curve's. The knob is per machine and per taste: this bench runs 1.5, and the commissioning side-by-side chooser (the "Initial commissioning" item under Next work) is how a machine finds its own. An owner measures their own curve from the panel: the dose-curve recorder streams the ladder job itself from one Record press (absolute from X0 Y0, refused while a sender is connected; the operator's button press starts the fire with every arm gate standing), records the tube current and the head thermopile, fits the rungs, and Apply writes the result (forgectrl/docs/SERVICES.md). Rasters hold their tonality down to ~14 pulse slots per pixel (508 DPI at 6000 mm/min): the dither accumulator's cross-pixel averaging recovers the levels, with no visible dither pattern.

An S word takes effect whether or not motion is in progress. Per-segment updates carry the level inside a laser block, but an S executed between blocks - with the planner drained, so nothing is streaming - arrives only through the synchronous spindle path, which publishes the duty without touching the fire state; and the next run re-asserts the laser state the core last asked for at its first byte, fire only inside an armed window. Without those two a standalone S from a sender slow enough to drain the planner left the following moves cutting at a stale duty, or dark.

Contract rules enforced structurally: a power byte leads every kernel run before any fire bit (a run start resets duty to ~100 %), transitions are coalesced per tick so power bytes are never consecutive, and power bytes cost no machine tick. Fire only ever rides motion segments of laser blocks — jogs, G0 and homing are fire-free by construction — and the end-of-data backstop covers every stream end. Duty persists after end-of-data (PWMSAR retains its last value): the laser-off guarantee rests entirely on FIRE.

Arming — the operator's button press is required. The first laser-on of a job (M3/M4, planner-synced) refuses outright if a coolant fire gate stands or if no head is detected (ALARM:3, "laser fire blocked: no head detected"), else forces the run fan profile on, unlocks the kernel laser latch, lights the button white and blocks the gcode stream — pumping real-time traffic — until the operator presses the physical button (EV_SW bit 2), a soft reset aborts, a lid or interlock open cancels, or laser_button_timeout_s (default 300 s) expires into alarm 3. The coolant verdict is re-checked immediately after the wait, before the window opens. The armed window survives S changes and M5/M3 toggles (no re-prompt mid-job) and closes — relocking the latch — at program end (M2/M30/%), when the sender connection changes, after laser_disarm_s (default 60 s) of spindle-off idle, or immediately on alarm/homing/reset/stream fault. The disarm grace counts down in Hold, Door and Tool Change too. Both keys live in the shared machine config, re-read per arm.

Underrun policy while armed: fail safe, no retry. The stop/run recovery restarts the kernel run, which resets duty to ~100 %, so replaying queued fire bits would fire at full power: an armed underrun acks the kernel and faults (alarm, latch relock, homing anchor unlinked). Motion-only streams keep the one-shot retry.

Coolant fire gates live (gfcool_fire_ok): a flow FAULT or an over-ceiling coolant temperature blocks arming and suppresses fire mid-job with a loud warning. While armed, the run fan profile and flow interrogation are forced on regardless of the sender's M8/M9; a SUSPECT/FAULT verdict inside an armed window takes the safe posture (feed hold + run airflow). SUSPECT auto-resumes on a clean re-check; FAULT leaves the hold and the gate for the operator.

The controller publishes its state for the daemon. forgectrl can never open the Grbl socket (a connection displaces the sender), so the controller writes two files under /run/forgefirm, atomically, on edges: grbl.settings (the $$ view, rewritten on every setting change and whenever the derived floor moves) and grbl.state (JSON: machine state and alarm, the sender session with peer and generation, the laser's armed window and dose model with its floor, the exact [GC:...] modal report, overrides, driver version, ts_mono for age; on change plus a 5 s heartbeat). forgectrl echoes the state file in GET /status as the grbl block only while it supervises a live GRBL controller, serves the settings file at GET /grbl/settings, and the panel's GRBL card renders it. Position stays out: it changes per segment and is served from the kernel counters. Contract: forgectrl/docs/SERVICES.md.

Emission evidence. cnc/laser_on_sampled (surfaced as /status laser.emission_samples) is the reliable live-emission witness; emission sensed with no armed window relocks the latch and stops motion. pic/hv_current is the only live HV telemetry on this PSU. cnc/laser_pgood_sampled is not a usable witness here — it reads 0 through real cutting.

Lid, interlock and button policy

Both controller modes react the way the factory daemon does (decoded from a factory 2.6.0-2228 session; measured numbers in the facts bank).

  • Lid or interlock open during a job, running or paused: motion stops within milliseconds of the edge, the job is canceled and not resumable, the head returns to the position the job started from with the lid still open, the kernel latch relocks and the armed window closes. The return-home park ignores the lid and always runs to completion. The next job re-arms with a button press — the same press the hardware button latch needs, so software and hardware agree by construction.
  • During the pre-run button wait: a lid or interlock open cancels the job with the reason named (clean soft reset, no alarm); a press with the lid open never arms.
  • Ignored: a lid open during a hunt, homing, a jog, or at idle.
  • The button pauses and resumes a job. Cloud mode uses the factory's laser-off backtrack and resume lead (cloud_pause_backtrack_ticks 2000 / cloud_resume_lead_ticks 1950), on a preloaded job and a live-fed one alike: the retrace is sized to cnc/max_backtrack and the lead follows it, so a pause with little history behind it shortens both rather than failing. GRBL mode uses feed hold / cycle start, so a resumed GRBL cut picks up where the deceleration ended (item 14). A pause is not a cancel: the latch stays unlocked and the window open across it. There is no resume dwell: the safing chain re-arms ~216 ms before the first step (facts bank).
  • lid_policy = hold selects stock grblHAL door behavior instead (park in Door, cycle start after the lid closes resumes with position intact).

Switch mapping (grblHAL-glowforge/src/glowforge_switches.c; the controller reads EV_SW with EVIOCGSW from the protocol thread's realtime hook, no grab): doors = bit 3 (the series combination the safety chain itself uses), remote interlock = bit 5 (inverted sense), button = bit 2. The door signal is hidden from the core while it is IDLE, JOG or HOMING (gfsw_visible) so a lid cycle at idle cannot park the controller in Door:0 and leave a sender waiting. hv_enable (bit 4) is never gated on — it is the readback of the chain's HV_ENABLE output, telemetry only. The interlock latch (bit 6) is not gated on either — the hardware chain enforces it. No switch device (host builds) = no capability advertised. GF_SWITCH_FILE is the file-backed EV_SW word that lets null-sink builds drive these edges in CI.

Homing

Runtime-selectable through homing_mode in /data/forgefirm.conf (forgectrl GET/POST /settings, panel selector); the driver re-reads the file on every $H:

  • gfcloud — factory camera homing via the Glowforge web service. Live verified; a full cycle runs in 50–65 s.
  • switches — the planned limit-switch cycle (falls through to the core, still disabled $22=0).
  • none — $H rejects with error 5.

Architecture: glowforge_homing.c registers a driver $H that shadows the core's; for gfcloud it suspends the stream engine (only from a fully idle kernel — closing the flock'd fd mid-program is an e-stop), spawns /usr/sbin/gfhome.py (config /data/etc/gfhome.conf, first-run copy from /etc/gfhome.conf.sample), pumps the protocol so senders keep getting status, then reacquires the device and re-applies the analog config and step_freq. ^X aborts the session (SIGTERM → SIGKILL); failure or timeout queues ALARM:18 like a failed core cycle (gfcloud_home_timeout_s, default 300). The runner drives the GFUIService dispatch itself (the stock run() loop can neither stop nor close the socket) and treats hunt + ≥1 accelerometer-witnessed motion window + quiet (10 s) as complete — the modern v2.6.0 sequence, captured from a live service session, is settings → hunt → lid_image → single corner move → lid_image → silence. It then re-homes the lens against the hall for a deterministic Z. A quiet service without an accel-witnessed motion window is a failure, not a homing.

Position semantics: factory home = machine origin (back-left corner, +Y = FRONT, workspace all-positive 0..495 × 0..279); Z top-of-travel = 10.6. gfcloud_home_x/y/z calibrate the post-home coordinates once measured (defaults 0 / 0 / Z max). GRBL mode permits unhomed cutting — position shows counters-only and painted red until anchored.

The machine-services daemon (forgectrl, port 8080)

Source: the forgectrl sibling repo (github.com/ScottW514/forgectrl, branch main, MIT). It is the ForgeFIRM machine-services daemon: controller-mode supervision, the pulse-device broker, the motion-liveness gate, the cooling engine (single owner of fans/pump/TEC/heater for both modes), plus cameras, telemetry, settings, diagnostics, the web panel, updates and the logging tree. It runs under a respawn wrapper (its init script); a restarted daemon retakes supervision once the machine is idle — an unmanaged controller left running mid-move is replaced at idle, not adopted (the old inherited fd cannot be taken over). The meta-forgefirm recipe pins its SRCREV in forgectrl-pin.inc (bump deliberately after pushing) and installs the sysvinit script from the repo's init/; bench builds cross-compile with forgefirm/scripts/bench/build-forgectrl.sh. The machine-services contract — EV_SW switch map, sensor conversions, hardware single-writer ownership, cooling channels, mode supervision, pulse-device ownership, logging — is forgectrl/docs/SERVICES.md.

Every state-changing endpoint requires the first-boot bearer token in /data (embedded in the panel), a Host address-literal check, and Sec-Fetch-Site/Origin validation (CSRF and DNS-rebinding refusal). /cool/state is loopback-only. /fuse-identity and unsigned-firmware installs additionally require the physical button held.

One ulfius daemon serves it all:

  • GET / — the tabbed control panel (Status / Machine / GF Cloud / GRBL / Diagnostics / Logs / System; sources in forgectrl/src/ui/, index.html + panel.css + panel.js, bundled into the binary by embed.cmake; tools/devserver.py and the repo's .devcontainer/ serve the same panel on a workstation against a live board or a mock). Status carries the controller-mode selector, the operational dashboard, a scaled lid snapshot and an on-demand live stream; System carries A/B slot selection, ForgeFIRM updates, image install/restore, the wireless regulatory region and reboot. All settings controls disable (with a banner) while the machine is not idle or a diagnostic is running. /?action=stream|snapshot remain the mjpg-streamer-compatible aliases (lid camera; LightBurn uses the stream one).
  • GET /status — motion state and true machine position (kernel step counters anchored at homing via /run/grblhal.homed — the Grbl socket is never polled, a connection there displaces the sender), coolant temps, pump/TEC, all four fan tachs, the sensed laser evidence (emission samples, HV current, lid IR), faults, the safety switches via EVIOCGSW (head = real presence, i.e. the head sysfs group exists), and a diag flag for the UI lock.
  • GET/POST /settings — the shared machine settings store (/data/forgefirm.conf, 0600, validated keys, empty-value-clears via query params; gf_password write-only). Writes 409 unless cnc/state is idle and 409 while a diagnostic owns the hardware; a multi-key POST lands as one atomic replace. Keys: controller_mode, homing_mode, gfcloud_home_x/y/z, gfcloud_home_timeout_s, gf_serial, gf_password, ui_units, wifi_country, the nine cool_* tunables, laser_button_timeout_s, laser_disarm_s, rail_settle_s, lid_lamp_idle, lid_policy, cloud_pause_backtrack_ticks, cloud_resume_lead_ticks, the twelve log_<logger>_disk|_remote levels and syslog_server|port|proto. cool_fire_ir_delta is a hand-edited conf key, not a panel setting.
  • GET /mode, POST /mode?controller=grbl|cloud — the supervisor: current mode, controller state (running | stopped | standby | motion-fault), pid, and the motion-liveness verdict (verified | unverified | fault); the POST is the live idle-gated mode switch and the retry lever after a motion fault.
  • POST /controller/stop|start — the routed emergency levers the init scripts use. Stop writes cnc/stop + cnc/laser_latch=1 before the SIGTERM (kernel-level, instantaneous) and holds supervision suspended.
  • POST /cool/state (job-state reports from the active controller, level- triggered ~1 Hz) and GET /cool/status (engine phase, verdict, temps, report age). The verdict the controllers enforce is the /run/forgefirm/cooling.state file.
  • POST /diag/flow-verify|flow-calibrate|abort, GET /diag/status — the diagnostics runner (below).
  • GET /cam/stream?cam=lid|head — multipart MJPEG at half the sensor's frame in each axis, 1296×972 on a 5 MP machine (2×2 Bayer-superpixel demosaic, JPEG q75; FORGECTRL_STREAM_Q overrides, FORGECTRL_STREAM_FPS caps the frame rate, unset/0 = sensor max).
  • GET /cam/snapshot?cam=lid|head&res=full|half&q=1..100 — single JPEG, default the sensor's full frame, 2592×1944 on a 5 MP machine (own MIT bilinear demosaic).
  • GET /cam/status — JSON (running/cam/clients/frames/fps/fps_cap/encoder/ buffers/sensor, the stream + snapshot geometry the fitted sensor implies, and the privacy gate's capture_allowed / stopped_by_lid). Stream and snapshot answer 409 while the lid is open.
  • GET /slots, POST /boot, POST /update/check|download|apply|upload, GET /update/status, POST /restore/factory, POST /system/reboot — the A/B update manager (docs/UPDATE-SYSTEM.md). Upload is auth + idle + job gated; a booted-slot write is refused under any root= spelling.
  • GET /logs, GET /logs/tail, POST /logs/export — the logging tree (below).
  • GET /fuse-identity — serial, derived hostname and the SRK password, behind the token AND the physical button; fetched on demand only.

Panel conventions: the header identifies the machine by its fuse identity (the factory hostname derived from the OCOTP serial), regardless of any cloud identity override. Units are a display-only preference (ui_units): the backend stores metric, and saves post only fields whose display string changed. Position always shows — counters-only and painted red while unreferenced, normal once anchored.

Camera engine. One worker owns the V4L2 node persistently (media-ctl / v4l2-ctl sequences identical to gfhardware/cam.py, factory exposure/gain/WB, software hflip in the demosaic); it starts on demand and tears down fully after 10 s idle so gfhardware one-shot grabs still work. Privacy gate: neither camera captures unless the lid is closed — machine_lid_closed() (EV_SW bit 3, fail-closed) is checked at every entry point and once per frame, so an open lid refuses stream and snapshot with HTTP 409 and a lid opened mid-capture tears the pipeline down; gfhardware.cam.capture() enforces the same rule for the cloud client's direct-V4L2 fallback and raises LidOpen. No setting disables it, and the factory's lid-open focus hunt now fails as a result (docs/VIDEO.md §2, forgectrl/docs/SERVICES.md). Geometry, Bayer depth and the manual control set come from a sensor profile chosen by whichever driver bound on that camera's I2C bus, so one image serves both the 5 MP OV5648 (2592×1944) and the 8 MP OV8856 (3264×2448) — both 8-bit BGGR, so the capture word and the demosaic are the same and only the geometry changes; /cam/status reports the model and the frame sizes that follow from it. A frame the capture queue flags errored is dropped rather than demosaiced, four in a row cycle the queue, and three cycles with no usable frame stop the engine; /cam/status carries the running health counts (src/camhealth.c, host test camhealth_test). The cameras share the hardware video-mux and the NEWEST request wins it: streams preempt (the current stream's clients end cleanly), snapshots borrow (pause, switch, grab one frame, switch back — a ~1–2 s freeze). The per-camera lamp (pic/lid_led / head/white_led) is raised to FORGECTRL_LAMP (default 132) while capturing and restored to the resting level on idle. The resting lid lamp is the lid_lamp_idle setting (0–255, default 236), asserted at daemon start, on a live settings change, and at every controller spawn.

Measured performance (bench): 15.0 fps sustained at 1296×972, sensor- limited — NEON superpixel→YUV420 convert (18–20 ms) plus CODA960 VPU JPEG encode (7 ms) on cached (non-coherent) V4L2 capture buffers, so there is no bounce copy; daemon ~41 % CPU with one viewer. Full-res snapshot 2.4 s warm / 2.7 s cold. Fallbacks, each bench-verified: FORGECTRL_NO_CACHED_BUFS (bounce copy, needed on a kernel without the allow_cache_hints patch — detected via the MMAP_CACHE_HINTS capability bit), FORGECTRL_NO_NEON (scalar convert, bit-identical), FORGECTRL_NO_VPU (libjpeg; also the snapshot path). The default path is newer and bench-proven: the GC880 GPU demosaic feeding the /cam/h264 CODA960 H.264 stream (render, IPU stride-fix crop, VPU encode; ~14 fps for one viewer at ~14 % CPU, luma bit-clean against the CPU path) with CSI hardware frame skip as the low-CPU setting; camera.h264-stream covers it in the acceptance catalog. FORGECTRL_NO_GPU / FORGECTRL_NO_H264 / FORGECTRL_NO_HW_SKIP strip them individually, each falling back to the measured paths above. /cam/status reports encoder and buffers. A CSI glitch frame can out-size the coda driver's default JPEG capture buffer, so forgectrl requests 3 B/px and drops error-flagged dequeues as single bad frames. LightBurn consumes the stream directly while jogging from the same session; motion coexistence is proven (clamped 0, max behind 4.5–7.2 ms of the 200 ms queue at 15 fps).

Run by hand: /usr/bin/forgectrl & after /etc/init.d/forgectrl stop (kill before scp when redeploying — text-file-busy). It logs through syslog (/data/log/forgefirm/forgectrl/forgectrl.log; a terminal, or FFLOG_STDERR=1, echoes the lines).

Wireless region. wifi_country (System tab, full ISO 3166-1 alpha-2 dropdown, default 00 = world) is applied with iw reg reload + iw reg set at daemon startup and on every change; the same pass pins wlan0 power_save off. With the regulatory db loaded and no user hint, cfg80211 follows the AP's 802.11d country IE; a user-set region overrides it. The startup pass hints a region only when one is set (hinting 00 into the default world domain makes cfg80211 report the confusing country 98 alias).

Diagnostics (forgectrl-owned hardware tests)

The Diagnostics tab runs tools that take the hardware over: the runner (diag.c, one slot) suspends the active controller through the supervisor (launch is gated on cnc idle + no diagnostic), drives the loop directly through sysfs, and resumes the controller on every exit path (completion, tool error, operator abort via POST /diag/abort, safety ceiling). The cooling engine suspends its own writes for the duration and publishes fire-blocked. /run/forgefirm-diag.active marks the ownership, and forgectrl startup recovers a stale marker. The laser is untouched throughout (latch stays locked). While a diagnostic runs, settings POSTs 409, /status reports diag:true, and the panel locks with a banner. Live progress streams through GET /diag/status.

Both cooling tools run at the configured duty/window/threshold, with cut-profile chassis fans (the characterization condition); pump-off windows hard-abort at 48 °C downstream:

  • flow-verify (~3 min): one check with the pump on, one with it commanded off, judged against cool_flow_rise. PASS = the threshold separates the readings; margins under 1.5 °C add a run-calibration warning.
  • flow-calibrate (~15–25 min): 3 trials per case, alternating, with settle gates between; reports both bands and recommends threshold = (flow max + no-flow min)/2 with an Apply button, or refuses when the gap is under 3 °C.

Cooling tunables are conf-backed: the nine cool_* keys (flow_rise, flow_heater_pct, flow_check_s, recheck_s, confirm_max_s, temp_max, temp_resume, cooldown_s, cooldown_max_s) live in /data/forgefirm.conf (Machine tab, validated ranges), and the cooling engine re-reads them at every run start (env GFCOOL_* > conf > compiled default; env stays the bench override and wins for the process lifetime).

Flow verification, as it runs: a one-shot check at flood start (M8) heats the loop at cool_flow_heater_pct for cool_flow_check_s and discriminates on downstream temperature RISE, with periodic re-checks every cool_recheck_s — a stopped pump is undetectable any other way. A check starts only once the sensors agree and the downstream reading is stationary (split-half mean difference, not peak-to-peak). An over-limit check is a suspicion, not a fault: the next completed check decides it (over-limit again → FAULT, clean → cleared, three cleared episodes in one job → aggregated warning), and a suspicion that produces no verdict within cool_confirm_max_s escalates to FAULT. Over-temp policy is the factory's: a CYCLE over cool_temp_max gets a feed hold plus forced cooling airflow and auto-resumes under cool_temp_resume; a JOG gets a jog-cancel.

Logging

rsyslog is the system logger and the only log writer. forgectrl and the grblHAL driver emit through the shared non-blocking fflog emitter (drops, never waits — a stalled log daemon can never park a controller thread), gfcloud/gfhome through SysLogHandler, the kernel through imklog; a controller's stray stdout/stderr rides a per-controller logger relay under its own name. Tree: /data/log/forgefirm/{forgectrl,grblhal,gfcloud,gfhome,kernel,system}/, size-capped and rotated at boot and hourly (the forgefirm-logging recipe renders the rsyslog rules from the settings at S19 via forgectrl --render-syslog). Levels (log_<logger>_disk / _remote) and the remote target (syslog_server/port/proto) are machine settings applied at reboot — the panel's Logs tab shows configured vs. effective and offers the reboot, plus a live viewer and a sanitized tar.gz export for issue reports (POST /logs/export; src/sanitize.c replaces serial, hostname, cloud credentials, panel token, SSID/PSK, IPs, MACs and e-mails with stable placeholders). Design and contract: SERVICES.md "Logging".

Release acceptance (forgetest, port 8090)

The release acceptance tool — catalog, campaigns, domain fingerprints, inheritance, the always-required core, invalidate-all, the release gate and the coverage currency rule — is specified on the site (Developers, "Acceptance"); the tool lives in forgetest/ and ships only on the dev image (/etc/init.d/forgetest, HTTP :8090). It is bench-validated: the full campaign on dev image 20260824230512 (c-20260824231028-b7ca) satisfied 45 of 45 from nothing, 36 of them unattended with the bench actuator in the loop, in 27 minutes, and the export reads "Release authorized: YES" for that image's manifest. That authorizes a release; it is not one until releases/v<version>/acceptance.json is committed.

  • Catalog: 46 tests in forgetest/forgetest/suite/, every one a port of a proven bench drill or a bench-verified check: the always-required core (image.health, kernel.latch-locked-idle, kernel.k1-k2, kernel.fire-line), forgectrl.*, logs.*, update.*, motion.* (pacing, jog round-trip, liveness probe, cancel/abort, dead-man, the lid, interlock and button parity tests), cooling.* (flow verification, fans quiet after motion, a gate setting tripping and off by value, a fan under its floor), camera.*, laser.* (emission witness, arm-wait lid, disarm-in-hold, armed kill, pause/resume/lid-cancel, the rapids after an M5 shipping dark) and cloud.* (the service protocol answered by the emulator in this machine's identity, with only the app to drive; the mode round trip with the lid-open hunt and the web-service homing on it; one real print; and the job-behavior tests under the offline service: the cloud client driven from a local socket with a synthesized laser-free job, no account, no network, nothing on the bed). Tests that share a setup are merged; the auto tests stay separate for failure isolation. 28 are auto, 9 operator, 9 live; with the bench actuator up, eight of the operator tests run in the unattended queue.
  • The operator's part is asked for by name, not by popup (the site, Developers, "Acceptance", "The operator's part"): a Ready prompt before a timed step, a standing notice the test takes down when the machine shows the action done (ctx.act("lid", "open") and its kin, the seam a bench actuator will plug into), and one confirm by eye left in the catalog (the emission witness's mark). The head accelerometer, the beam detector, the button LEDs, and a lid-lamp toggle between two snapshots replaced the other eyeball confirmations; kernel.fire-line and camera.snapshot are auto. With the bench actuator up the attended block is the ten tests that need a person (five laser live, five cloud): 12 minutes on dev image 20260824230512. A test's implementation hash is its own function plus its module's shared code, so a fix inside one test re-requires that test alone.
  • Machine identity is content-defined. Every component recipe contributes forgefirm-manifest.bbclass entries (the kernel and the module through do_deploy), forgefirm-image-manifest.bbclass assembles them plus the layer content hashes into /etc/forgefirm-manifest.json (also deployed beside the image as *.forgefirm-manifest.json), and scripts/manifest-from-tree.py computes the byte-identical thing on a workstation — the identity is content-defined, independent of the checkout's commit or dirty state. Component pins live in <recipe>-pin.inc (SRCREV + the PV that moves with it, nothing else) and are left out of the layer content hash, so a pin bump invalidates only the tests covering that component; a pin written into a recipe body counts as a platform change and invalidates everything.
  • Baseline rule: every test and bench tool is bracketed by a baseline pass (forgetest/baseline.py), against a fresh-boot reference taken once per boot after a power cycle (a soft reboot leaves the lid lamp dark — the PIC lights it at power-on). Takeover runs capture the controller-owned kernel attributes on entry and write them back before forgectrl restarts, so a leftover motor_lock mask can never read as a wedged driver.
  • Coverage currency is enforced in CI (python3 -m forgetest.coverage --enforce in forgetest-ci.yml, over the tree manifest): an uncovered manifest path fails the build, because it would let an inherited PASS survive a change that should have invalidated it.
  • Bench tab: every board-runnable tool in scripts/bench is runnable from the page (scope tools, the flow characterization family, the escalation drill, the live drills, resume_dark_lead.py), with takeover tools bracketed by a forgectrl stop/start. scripts/bench/gfbench.py resolves GF_HOST (host mode, ssh) or the board itself (local mode). Not ported by nature: the two null-sink CI harnesses and the .puls decoder.
  • Releases are signed only when releases/v<version>/acceptance.json authorizes the built rootfs (scripts/release.sh).

Hardware facts bank (measured)

  • The bench actuator's wiring (fixture/README.md for the box itself). Three 3.3 V optocoupler relay modules, high-level trigger, coils from the machine's 3.3 V (about 100 mA each), inputs from the ESP32-S3 DevKitC-1's GPIO 4 (lid), 5 (interlock), 6 (button), the button's enable jumper on GPIO 7 to GND. The lid contact (NC) goes in series with the lid-switch loop at J4.12/13; the button contact (NO) across the front button input at J5 (BTN and its 12 V); the interlock contact (NC) in the remote interlock loop at J8 (SAFETY.md; J6 is the speaker). The machine's 3.3 V rail carries the three coils with room to spare. The DevKit and the machine share a ground through the modules, so the DevKit is powered from a USB wall adapter. The interposer harness itself is bench-local and is not described in any repository.

  • The factory's envelope, decoded (firmware 2.6.0-2228, the 23 captured headers, this board's own factory logs). The pulse header is the job's operating envelope and the factory refuses to cut without it: 29 tags are mandatory, 346 are header-legal, an unknown tag is logged and skipped. The service fills the fan duties, the coolant window, the per-sensor temperature ceilings, the lid IR thresholds, the accelerometer thresholds and an HV current cap per job; a cut job carries the real fan duties (air assist 1023, exhaust 65535, intake 43278, equal to ForgeFIRM's run profile) and a hunt or motion file carries air assist 204 with the extraction fans off. Every tach window is zero in every capture except AArx 64500 on cuts, and the factory's intake and exhaust tach monitors treat zero as not configured, so a stalled extraction fan is caught there by the temperature it causes; when a fan alert does fire during a cut the factory pauses the print on the same transition as a user pause. Temperature runs two tiers there: a plain alert pauses, a *_temp_critical fails the machine; the units are per sensor (the coolant family is carried twice, raw counts with the NTC's hot end as "min", and millidegrees), and a stock machine's live coolant window is 10 to 30 C idle and 5 to 35 C warm-up and run, CMrx 33000 on a cut being exactly the shipped 33 C ceiling. The factory does not verify coolant flow: the calorimetric CF controller in its firmware is never armed and its heater is written only at phase changes. ForgeFIRM's answer, all of it landed and bench-proven in the catalog (cooling.gate-off, cooling.fan-gate-trips, cooling.critical-tier, the hunt leg of cloud.mode-switch) and in the CAMPAIGN-LOG drills: every gate a plain setting with an off end; a header value only ever tightening a local one; every fan held to a measured floor with a fault, not a pause, for the session; a coolant critical line above the ceiling's pause; the board temperatures watched per job; and the rest of the envelope declared, tag by tag, in CLOUD.md "The pulse header".

  • Board temperatures at idle (room ~22 C, machine on for hours): the chassis LM75 reads 29.0 C, pic/pwr_temp reads 589 raw (the unverified guess raw * 0.08715 - 21 would make that 30.3 C), the SoC die 42.8 C. Ranged per job by the engine from here on. The supply stays a raw count by decision: its heatsink cannot be reached with a thermometer while the machine runs, so the conversion is not going to be verified on this bench, and a number nobody has checked is not published as degrees. The per-job range in raw counts is the record, and a ceiling, if one is ever wanted, is set in raw counts from it (temp_calibrate.py supply-* stays for a machine where the heatsink is reachable).

  • The SoC guards itself. The i.MX6DL (rev 1.3) on-die monitor is thermal_zone0 (imx_thermal_zone, the same node as hwmon0), governor step_wise, trips at 85 C passive and 90 C critical (the consumer-grade points the driver derives from the fuses: hot point 95, critical at hot minus 5, passive at hot minus 10). The passive trip is bound to cpufreq-cpu0 (996 / 792 / 396 MHz OPPs; performance is the only governor built, so the core sits at 996 MHz until the trip lowers it) and both GPU cooling devices; the critical trip is the kernel's orderly poweroff. A throttle slows the engine, the camera and the protocol thread before the step stream (the ring is in hand). The factory board carries no heatsink or fan on the SoC, only the mounting holes for one, and needs none: under a full core for five minutes on top of the live camera stream, in a 30 C chassis, the bare die plateaus at 70.8 C, 14 C under the passive trip, with the core at 996 MHz and no cooling device off state 0. The die-to-chassis delta at full load is about 41 C, so the passive trip is a hot-chassis case (above roughly 44 C), not a load case. The per-job SoC range and the throttle log line are the running record.

  • Fan speeds at the cut profile (exhaust duty 65535, intake 43278, air assist 1023; sampled at 1 Hz over 120 s from idle, the exhaust duct's inline booster fan off): exhaust 11640 rpm steady (spread 11444 to 11947, 90 percent of steady in 5 s), intakes 4157 / 4158 rpm (spread under 100, 7 s), air assist 11050 rpm (spread 30, 1 s); at idle the exhaust and intakes read 0 / ~745 rpm and the air assist ~1900 rpm (idle duty 204). The purge-air fan is always on and reads ~625 counts of head/purge_air_current (~1 when off). The airflow floors are 55 percent of these (bands 50 to 60 percent); an inline booster fan changes the exhaust's back pressure and can move its reading by a few percent either way, well inside the margin.

  • DRV8825 stepper drivers wedge on 40 V rail glitches (factory board; the TMC2130s belong to the upgraded OpenGlow board only). A glitch can leave the drivers unserviceable: SDMA playback and the position counters run normally while the motors produce nothing. The supply itself is fine — this is a driver failure mode, not a marginal rail. Their reset lines are strapped (no kernel pin), cnc/faults does not flag the state, and whether a given rail power-up wedges them is chance. Recovery: a longer true power-off (the forgectrl supervisor ladders 5/15/30 s) and, at worst, a full machine power cycle. Consequences: counters, anchors and H:1 are never proof of motion; keep the rail up (every power-up is a wedge lottery), which is why the pulse-device broker exists and why there is no idle-rail-off policy.

  • Motion liveness = the head accelerometer (glowforge.dts head-accel, i2c-3 @0x1e — resolve iio devices by bus path, never by index; lid = i2c-0 @0x1e, board = i2c-3 @0x1d). Signatures on an identical commanded move: real motion 1800–2900 counts peak-to-peak on X/Y (noise floor at 1 g ≈ 16384), a genuinely dead/wedged axis ≤ ~250, and the rail-on / current-step jolt up to ~700 — which is why the forgectrl probe gates controller start at p2p ≥ 800 (P2P_MOVING), writes cnc/motor_lock=0 for its own move (a leftover mask from any tool must not read as a wedge) and settles 300 ms after the run-current step before sampling. A masked axis reads 144–480. gfhome requires at least one accel-witnessed motion window before a quiet service counts as homed. Raw sysfs accel reads are slow (~150 ms each) — enough for a binary verdict over a multi-second window, not for waveforms.

  • Any probe/liveness move goes RIGHT (+X) first, then back: a cable lives at the end of LEFT travel and must never be crushed.

  • Rail-contact signature (from the retired accelerometer-homing spike, relevant to any future contact sensing; tools accel_fast.py, bump_seek.py): creep baseline ≈0.5–2 k counts, contact jumps to 29–42 k within ~4 ms (20–40×). But slow approaches are near-silent — belt compliance turns slow-speed skipping into sub-threshold grinding — so any contact-sensing scheme must strike fast. Direct I²C (unbind st-accel, CTRL1=0x6F = 800 Hz ODR) reads ~530 Hz from Python; st_accel sysfs one-shots are ~6 Hz and the kernel has no IIO triggers.

  • WL1805 Wi-Fi rides uSDHC1 (mmc0, 4-bit, SD-high-speed at 49.5 MHz, no-1-8-v; IRQ GPIO6_04, WLAN_EN GPIO5_26). Factory pad control, now ours too: CMD/DATA 0x17069, CLK 0x10069 (SPEED_MED, DSE 48 Ω, fast slew, HYS; 47 kΩ pull-up on CMD/DATA only). eMMC (uSDHC3) and the SD slot (uSDHC2) use 0x17059/0x10059 (80 Ω), SD2_DAT3 0x13059. An SDIO CRC error surfaces as sdio write failed (-84) and costs ~1 s of Wi-Fi (wlcore firmware recovery) — see "Wi-Fi SDIO CRC watch" under Next work.

  • SDMA pulse engine: ring size = the ring_mb module parameter (default 32 MiB, the factory ring size; power of two, must fit the 32 MiB cnc-pulsebuf no-map DT pool). Free = size − 32 KiB gap, so 33,521,664 bytes. Bench-verified on the 16 MiB ring the earlier images shipped, and the mechanism is size-independent: 20 MB streamed at 100 kHz through the wrapping ring, 0 ENOMEM, 0.4 ms max write latency, starve → underrun per protocol. The ring holds ~1 MiB per 100 s of 10 kHz stream, so ~56 min of a cloud print at a time; a longer job is fed live as it plays, and the grblHAL feed keeps only a few KB in flight. The 32 KiB gap is retained history: the writer stops that far short of the play head, so any fill leaves 3.2 s of played program (at the print tick) to back a pause into, which is what cnc/max_backtrack reports less the deceleration tail. The engine's ipg and ahb clocks are enabled only by a channel holder: imx-sdma leaves them off after probe, and glowforge.ko holds them itself through sdma_get_channel() in the SDMA API patch for as long as it is loaded; nothing else on this board holds an SDMA channel (ecspi2 runs PIO). With the block gated every channel-0 transfer completes at once and moves nothing: the ring reads back its bounce page, the probe cannot start and cnc/free exceeds the ring, which is why image.health asserts the clock enable count directly.

  • Reserved memory: 511 MiB usable DRAM (0x10000000–0x2fefffff), of which 96 MiB is reserved for DMA: the 32 MiB cnc-pulsebuf no-map pool (dynamically placed, alignment = size, so it lands at 0x2c000000) plus 64 MiB of reusable CMA for camera/IPU/VPU buffers. no-map means the pulse pool is gone from the kernel's map whether a job uses it or not, which is what makes dma_alloc_coherent() deterministic for a late-probing out-of-tree module. The 1 MiB above the memory node (0x2ff00000, held back by the bootloader) is pstore/ramoops: 32 KiB dump records, a 256 KiB console record, 16-byte ECC, mounted at /sys/fs/pstore from fstab and staged by the log export. MemTotal ~464 MiB on the board-only kernel (linux-fslc 6.12, SMP off, CONFIG_PREEMPT=y, zImage 4.8 MB, 31 module packages, ROM SDMA scripts); measured idle use in GRBL mode with the daemon and controller up is ~100 MiB. The playback script is relocated to SDMA channel 26 at <26 0xF00> (halfword 7680) with a pre-run integrity guard; the probe lines to look for are EPIT clock 66000000 Hz and SDMA channel 26 reserved for pulse playback (script at halfword 7680). Measured script ceiling ~165 kHz effective (~6 µs/byte); position counters (sdma_context sc0/1/2 = X/Y/Z steps, sc3 = bytes) match grblHAL exactly. Underrun proof: 100 kHz × 120 s under full load, 150 ms queue, 0.2 ms worst write latency, zero underruns. Real time: the kernel runs CONFIG_PREEMPT=y (the factory behavior; imx_v6_v7_defconfig alone gives PREEMPT_VOLUNTARY). PREEMPT_RT is not selectable on arm32 6.12 (no ARCH_SUPPORTS_RT) and is not needed: the ring drains at 1 byte per EPIT tick, at most 200 KB/s even at the 200 kHz ceiling, so the feeder's bounded queue depth of ~150 ms (a few KB in flight) rides out worst-case scheduling latency with orders of magnitude to spare. Bounded queue depth plus SCHED_FIFO for the feeder is the design; RT is worth revisiting only if the underrun bench ever contradicts this arithmetic.

  • Byte layout and stream rules: see the UAPI.md feeder contract (authoritative).

  • Z: bit 6 SET = lens UP = +Z (hardware-verified). Home = hall trigger at TOP; usable travel ≈ 30 half-steps ≈ 10.6 mm ≈ 0.417"; 0.3534 mm/half-step. Never blind-drive Z — hall-supervised only.

  • XY: 0.15 mm per full step; DIR bit set = −X / +Y (Y1/Y2 complementary). +Y physically moves the gantry toward the FRONT. Home corner (convention, for the planned limit-switch homing) = back-left (X min, Y min), workspace all-positive from that corner.

  • Factory motion profile (measured from captured factory pulse streams with puls_profile.py): accel ≈ 700 mm/s² X / 590 mm/s² Y on v2.6.0 firmware (2018 firmware used ≈1000); header HAxr=132/HAyr=112/HAar=133 ⇒ ≈5.3 mm/s² per HA unit. Travel moves peak 202 mm/s vector (≈ 8 in/s) at STfr=28160 Hz; prints and hunts run STfr=10000. Cut feed in the sample print: 145 mm/s. Z cadence ≈ 61–115 ms per half-step (≈ 5.7 mm/s max).

  • Factory analog config (constant across all captured jobs, 2018→2026): PIC currents X 135 run / 33 hold, Y 22 run / 5 hold (axis DAC scales differ by design); x/y_decay=1; ×8 microstepping; run currents applied only while motion plays, hold otherwise.

  • Laser PWM: 39.98 kHz register-verified (divider 13 × 127 counts), scope- confirmed at 25.0 µs period across the full duty range, clean at the low end (6.4 % measured vs 6.3 % commanded at PWMSAR=8).

  • Laser duty thresholds (ladder on scrap at F300, constant power): the tube has two thresholds, far apart. The discharge strikes between 2 % and 3 % duty — 2 % (PWMSAR 2) draws no measurable hv_current and leaves nothing at all, 3 % (PWMSAR 3) draws current — but it does not lase usefully until 16 % (PWMSAR 20), the lowest duty leaving a continuous mark. Between them (3–14 %) is a dead band: current flows and climbs, and each line shows only a spot at its start (the strike transient) with a dark line after it. So the usable analog range is ~16–100 %, and $35 (DEFAULT_SPINDLE_PWM_MIN_VALUE) ships at 16 to hold every nonzero S above it. Raw hv_current counts are a presence/absence witness only: the per-rung means are non-monotonic at the top of the ladder and the signal has no characterized transfer function.

  • Factory power model (three cloud cuts of one 1" square, same location, material and speed, only the UI power setting changed, pulse files captured from each): the power byte is pinned at 127 in all three runs — three occurrences each, one as the cut begins and a refresh every ~27 000 ticks (~2.7 s). Analog duty is never a power control. Dose is FIRE-bit density on a fixed 7-tick period (700 µs at STfr = 10 000, ~1.43 kHz), the on-count dithered between adjacent integers to reach a fractional duty: Precision Power 1 = 1.371 of 7 (density 0.1953, runs of 1 and 2), PP 100 = 5.576 of 7 (0.7952, runs of 5 and 6), Full Power = 7 of 7 (0.9965, continuous). The period was exactly 7 in all 570 measured cycles of both dithered runs, and the mix of adjacent on-counts matches the fractional part exactly (PP 1 wants 1.371; 2-runs are 212 of 571 = 0.371). The three headers are identical — the power setting never reaches the machine, so the whole model is service-side. Motion is identical too: 5420 steps, 101.62 mm, 10.81 s at 9.44 mm/s. Density tracks velocity through corners, by the same relative factor at every power setting (corner/cruise 0.38, 0.38, 0.41), but only partly: fire ticks per step rise 3.89 → 7.00 as speed falls 9.44 → 1.22 mm/s, so dose per unit length rises ~1.8× at a corner instead of the ~7.7× it would rise with no compensation. On the UI scale, PP 1→100 is linear in density (~0.006 per unit, intercept ~0.189) and Full Power sits off that line, where PP ~134 would land.

  • Density dose limits (measured on five ladders, dladder): under the FIRE-density model the interval between pulses at a level below the minimum is min_ticks x tick / density - the base period cancels, which is why periods 10, 20 and 40 gave identical results. The tube strikes down to ~5 % density at a 2.26 ms interval (min_ticks 3, 106 us pulses) and fails to strike at 4.51 ms (min_ticks 6, 213 us): lengthening the pulse at fixed density lengthens the gap in proportion, and the gap is what kills re-striking. It marks from ~10 % at F300 on scrap. min_ticks 3 is essentially the factory's own structure - its 6.5 % engrave jobs put 100 us pulses 1.54 ms apart, against 1.64 ms for min_ticks 3 at that density - and 6 is outside anything the factory does. Below ~5 % no pulse shape reaches the tube: the interval grows as 1/density, so 1 % implies an 11 ms gap, five times what already failed. The scale closes that gap instead: $35 = 10 maps S onto 9.4-100 % density, putting a commanded 1 % at 10.2 %, and a ladder weighted to the bottom (1, 2, 5, 10, 20, 40, 70, 100 % of S) then marked on all eight rungs, with eight current segments and means rising 136 -> 968. So a user's 1 % is a real, visible mark rather than silence.

  • Cooling operating point: 40 % heater duty, 50 s window, flow-rise threshold 14.4 °C, re-checks every 150 s. Below ~40 % duty the stagnant loop sheds the heater's output by convection well enough to mimic flow (at 30 %, three of five dead-pump trials looked healthier than a working pump). Record at 40 %: 25/25 correct classifications, plus all three settle cases. Settled- loop noise is 0.52 °C peak-to-peak but only 0.11 °C split-half, which is why the stationarity gate uses split-half means. Coolant windows: run ceiling 33 °C, resume 31 °C (factory job-header CMrx/…); the factory's low side (floors ≈1.0/4.0 °C, ~16 °C warm-up gate) is not implemented yet. The coolant thermistor conversion is the factory B-equation recovered from the v2.6.0 binary — derivation in kernel-module-glowforge/UAPI.md; the old UAPI "best guess" linear formula was 3–5 °C high and everything derived from it had to be re-derived. The flow check's bands hold from 19 to 27 C, the loop heater's ceiling in a 20 C room, with the margin widening warm; above that only a running tube warms the loop, and the check takes the tube's share off. With the pump on, a heater slug reaches the upstream sensor within seconds and inflates the instant reading by a degree; the warm-up release therefore judges a one-minute rolling minimum of that reading.

  • The four pic/lid_ir_* channels are first of all a photometer for the lid lamp. Measured against lid_led (sysfs brightness, 0 to 1023): all four channels follow it as a straight line, 2 counts dark, 32 to 35 at 128, 54 to 61 at 256, 96 to 105 at 512, 131 to 143 at 768 and 161 to 177 at 1023; channels 3 and 4 read about 7 percent above 1 and 2. Against that lamp-set level, a full-power cut raises them only +4 to +6 counts and a candle burning on the bed +3 to +6, with ±3 counts of ambient noise and ~+22 counts of day-to-day drift. forgectrl's camera engine drives pic/lid_led for every lid capture, and the resting level varies (131, 8 after a reboot, cloud mode sets its own), so a fixed-count gate fires a phantom FIRE stop on any lamp change. cool_fire_ir_delta therefore ships 0 = watch-only; each job still logs baseline and peaks.

  • Emission and HV witnesses: cnc/laser_on_sampled goes to its full 255 count on a commanded fire window and returns to 0 at Idle — the reliable witness. pic/hv_current tracks the cut (0 idle → hundreds/1023 raw while firing) and is the only live HV telemetry on this PSU (hv_voltage is grounded). cnc/laser_pgood_sampled stays 0 through real cutting: not usable here.

  • Switches: truthy = closed/OK for lid/doors/button. SW_INTERLOCK is INVERTED: the remote interlock (the regulatory 2-pin lockout connector) reads ACTIVE only when the loop is OPEN. Basic/Plus — including the bench machine — ship the connector factory-jumpered, so the bit reads 0 = satisfied; Pro brings it out for an external lockout chain. It must NOT gate motion (the beam is hardware-gated), but ForgeFIRM's kernel module does drive INTERLOCK_RESET high whenever the loop reads open, so the CD4043B latch blocks the LASER_ON gate in hardware until the loop is closed again (bench-verified: loop pulled → interlock_latch=1, interlock_circuit b4 set, all within one 50 ms sample; reinserted → all clear).

  • hv_enable (EV_SW bit 4, GPIO4_06) is the readback of the safety chain's HV_ENABLE output through the U24 inverter — not an input. Active for the whole duration of any run, inactive at idle, and it drops 454 ± 3 ms after the last charge-pump pulse (one-shot t_w measured pulse-to-drop with scripts/bench/cp_watchdog_timing.py: 451.8 / 455.6 ms; feed period 199.98 ms; matching the measured R·C ≈ 500 kΩ × ≈900 nF). It gates nothing — it is telemetry (/status switches.hv_enable, panel "HV enable"), read alongside cnc/charge_pump_alive (interlock_circuit b5). Across a pause and a resume (measured at the pads with scripts/bench/resume_dark_lead.py, ~2 kHz through /dev/mem): a pause stops motion 317 ms after the command and HV_ENABLE drops with the watchdog 550 ms after it, so a pause shorter than about half a second never drops HV at all; on the resume HV_ENABLE and the watchdog are back within ~3 ms while motion only restarts at ~219 ms — the chain re-arms ~216 ms before the first step, so a resumed cut loses nothing and no dark dwell is warranted. Naming note: the factory design labels this net E-STOP; entries in CAMPAIGN-LOG.md written before the 2026-08-15 rename call it estop/SW_ESTOP with the pre-rename polarity (the DTS then declared the pin active-high, so the bit read HIGH at idle and LOW through a run — the same physical behavior, inverted). The DTS now declares it active-low, and the former estop_halts_motion / MOTION.ESTOP_HALTS_MOTION opt-in is gone: a real e-stop belongs in the lid-switch chain (docs/SAFETY.md). Doors/door1/door2 stay stable during motion.

  • Factory job behavior on the lid and the button, measured on 2.6.0-2228 (bench session 2026-08-16; this is what ForgeFIRM's parity policy reproduces). Lid open mid-print: cnc/stop 5–6 ms after the edge, decel to idle in 86–91 ms, the return-home park starting ~300–340 ms after the edge and running to completion with the lid still open, the job reported :cancelled. A cancel from the app takes the same path. The button pauses a print — controlled stop, then a 2000-tick laser-off backtrack — and resumes it with a 1950-tick laser-off lead; the button flashes white while paused. A lid open while paused cancels the job and parks from where it stands. The lens hunt is not lid-gated.

  • The hardware button latch is what makes the armed window honest. A lid open SETs it (set-dominant), and it stays SET until the lid is closed, the SoC lock is released and the button is pressed (docs/SAFETY.md). So a policy that cancels the job on a lid open and re-arms only through a fresh button press keeps software and hardware in agreement by construction; one that resumes a job after a lid open leaves the beam blocked in hardware while software believes it is armed.

  • interlock_circuit bitmask: b0 = SoC-side LASER_ON monitor, active LOW (1 = not lasing); b1 = FIRE, active high; b2 = button latch; b3 = latch, 1 = locked; b4 = interlock latch reset; b5 = charge-pump watchdog readback. b0/b1/b3 were pinned by scope experiment, b2/b4 come from the factory decode. cnc/laser_latch is write-only, so lock state is read from b3.

  • Machine identity from OCOTP nvmem: HW_OCOTP_MAC0 is the serial, base-23-encoded to the factory hostname (BCDFGHJKMQRTVWXY2346789, XXX-YYY) — fuse-verified against the factory label, and the C implementation matches gfhardware id.py over 200 k random serials. The bench machine's actual values are deliberately not recorded here: this is a public document and a fuse identity cannot be rotated.

eMMC boot & recovery architecture

  • eMMC (mmcblk2): 3.6 GiB user area + two 16 MiB hardware boot partitions (mmcblk2boot0/1). Factory user-area MBR (per the factory .fw manifest): p1/p2 = 200 MiB rootfs A/B at blocks 8192/417792, p3 = /data from block 827392 to end of disk. (The bench board ran the legacy ForgeFIRM layout — p3 shrunk plus a p4 — until slotmigrate reclaimed it to the byte-exact factory geometry.)
  • U-Boot lives in boot0 at 1 KiB (IMX IVT header), not in the user area. Any boot0 rewrite below 0xC0000 risks the bootloader.
  • Saved env: user area 0x80000 with a redundant copy at 0x82000 (what ffboot/fw_setenv target; boot0's own 0x80000 region is zeros). Slot selection = mmcdev/mmchwpart/mmcpart/mmcroot. Gap: ffboot sets three of the four but never mmchwpart — it relies on the saved 0.
  • Default (compiled-in) env boots recovery: mmcdev=1 mmchwpart=1 boot_recovery=yes — a blank or corrupt env lands in recovery mode, not a brick. bootcmd: select mmc dev+hwpart → load and import /boot/uEnv.txt from the selected partition → if boot_recovery=yes, boot kernel+DTB from raw boot0 sectors, else load /boot/zImage from the slot's rootfs. U-Boot polls the button at power-on for a recovery request.
  • boot0 map: MBR / U-Boot @1 KiB / zeros @0x80000 / recovery DTB @0xC0000 (fdt_dev_addr=0x600, 64 KiB slot) / recovery zImage @0x100000 (image_dev_addr=0x800, 5 MiB slot, kernel 3.14.28) / recovery squashfs = boot0p1 @6 MiB (10 MiB slot). boot1 map: MBR / squashfs @1 KiB = boot1p1, mounted as the recovery /usr (python runtime) by init.d/recovery-usr.
  • Recovery userspace = the factory setup webapp (bottle): WiFi setup/AP, log export, /version, and .fw upload (→ tmpfs → glowforge-updater -f → fwup signature check → writes slot A → flips env). It is never updated in the field, so every machine still runs its as-manufactured recovery.
  • Factory .fw format = signed fwup 0.14.2 archive (ZIP: meta.conf + meta.conf.ed25519 + payloads). Tasks: complete (MBR, U-Boot to user area, zero both env copies, rootfs → slot A, zero p2/p3 heads) and upgrade.a/upgrade.b (raw-write rootfs.ext4 into a slot). Factory updater flow: authenticated GET <server>/update/current → {version, download_url} → resumable download to /data/glowforge.fw → verify against /glowforge/pubkeys → apply to the INACTIVE slot → fw_setenv mmcpart mmcroot → reboot. Factory rootfs.ext4 is 65 MiB; the ForgeFIRM release rootfs uses about 89 MiB, so it fits a 200 MiB slot with headroom.
  • Facts about the factory 2024 firmware (learned during the slot install): no /factory/imgN mounts, the generic fw_env.config points at the WRONG device (use the per-device fw_env_mmcblk2.config — ffboot's selection logic), no SSH (serial console only), and the factory kernel cannot see the SD card (ffboot -s needs -f from factory). Factory /etc/version is a numeric datetime stamp, so newest-slot selection is integer comparison.
  • Platform quirk: busybox mount's auto-type iteration against an already-mounted ext4 device prints a kernel "Can't open blockdev" for each foreign-type (ext3/ext2) exclusive claim before the ext4 attempt joins the existing superblock. Cosmetic only; ffboot and the installer reuse existing mountpoints from /proc/mounts and mount fresh targets with explicit -t ext4.

Next work

Open items only. Anything closed is in CAMPAIGN-LOG.md.

  1. TEC handling (planned). thermal/tec_on is a bare on/off output with no readback, so presence cannot be detected: it becomes a tec_present user setting (Machine tab, default off; ForgeFIRM never drives tec_on unless set), which also covers retrofits. Operation when present: simple hysteresis while a job runs — TEC on above cool_tec_on_c, off below cool_tec_off_c, defaults from the factory setpoints (CMet/CMdt 18134/18364 mdeg — the same WTub/WTvb raw-754/751 pair that proved the thermistor curve), off at idle — with cool_temp_min as the chill floor, so the TEC can never drive the loop toward condensation or freeze territory. Whether a given unit has a TEC at all is a spec-level claim (Glowforge ships it on the Pro; Basic/Plus use the same passive closed-loop cooling), not teardown-verified per unit — another reason it is a setting.

  2. Fire watch (lid IR) redesign. The gate stays disabled (cool_fire_ir_delta = 0) until it is lamp-aware: the engine must own or observe the lamp level (suspend the watch and re-baseline for a few ticks after any lid_led change) and the threshold must be relative to the lamp-set level, not a fixed count. Even then the signal is weak — a candle reads like a cut — so the head camera or a real flame sensor is the honest path to fire detection that means something.

    One lead worth a bench hour before building anything. The cloud ships flame thresholds in every pulse header, and the numbers do not look lamp-naive: baseline 3 counts on all four channels, alert at 275 and critical at 688 on the first quartile, 374 and 1022 on the second, with the third and fourth left at zero. The lamp response (facts bank) puts a fully lit lamp at 161 to 177 counts on every channel and the dark floor at 2, so the factory's alert sits above the lamp and its baseline matches the floor: the factory rides out the lamp by choosing thresholds above it rather than by tracking it, and the watch could be re-armed on fixed numbers after all. Still unproven: that the header's quartiles map onto the raw channels and share their units (all four channels behave alike, while the header leaves the third and fourth quartiles at zero). Confirm against the header the next cloud job carries. By decision those header thresholds (IR??) are the prior for this redesign and nothing else: the cloud client declares them ignored, and the watch stays disabled until it is lamp-aware.

  3. Limit-switch homing. The planned second homing method ($22 stays 0 until it lands); printable brackets are in 3d-models/. Also: calibrate gfcloud_home_x/y against a jog to a known reference if the factory corner offset matters.

  4. Cameras. First light on an 8 MP (OV8856) machine: the whole path is written but nothing has run on one, and only that hardware can answer whether the 2-lane RAW8 full-resolution mode locks the D-PHY at 720 Mbps/lane and what exposure/gain the sensor wants; the details, the reachable-mode reasoning and the factory fallback configuration are in the headers of kernel patches 0011-0013 (meta-glowforge-bsp, recipes-kernel/linux/). Lens shading (OmniVision LENC) is not a gap: the factory rootfs carries load_cam_regs.sh, a loader that writes a register file into the OV8856 driver's regs sysfs attribute (OV8858 0x58xx addresses remapped to 0x59xx), but nothing calls it; the app references /usr/bin/apply_cam_regs.sh, which is not on the rootfs; the OV5648 driver has no regs attribute; and this machine's /data holds no register file. No shipped machine applies a per-unit shading table, so ForgeFIRM owes none. Finally the deferred emulator homing-image smoke, now that the emulator can be pointed at live snapshots.

  5. Cloud mode. A print is no longer capped by the ring: the client holds the compressed body, fills the ring before the button, and tops it up as it plays, with the body bounded by pulse_reject_threshold_bytes because memory is what that costs. A feed that wedges is caught by progress rather than by ring depth (a healthy feeder keeps the ring brim-full, so depth only falls an hour after the feed died): thirty seconds of no progress with room in the ring stops the job cleanly and retraces, and it resumes if the feed moves again. A running print also reports itself to the app again, on the carrier a factory-session capture settled: the type:"progress" frame that is the periodic settings report, every 30 s and at every phase change, divided by the job's own length rather than by the kernel byte counter that climbs all job long under a live feed. The cloud.* acceptance tests cover all of it on the bench, a print longer than the ring fed from the live service included, and the app has been watched reporting a print's progress. gfcloud.init autostart with controller_mode = cloud is validated on a flashed image, and the lid flash follows the action's LCfl. What is left is tracked in python3-gfhardware/forgefirm-app/docs/CLOUD.md "Outstanding items" and is short: whether the service accepts an 8 MP machine's larger images (no HD machine has been on the bench). The pulse header's envelope is settled: every tag the service fills in is applied, passed through as a limit that can only tighten, refused on, logged or declared ignored with its reason (CLOUD.md "The pulse header"), and the gates behind it live in the cooling engine so they hold in GRBL mode too. The memory guards (pulse_reject_threshold_bytes, 128 MiB of compressed body) stay reasoned rather than measured, by decision: nothing the service sends comes near them, and every job logs the body and program sizes the guards are reasoned from. The lifecycle keys (CFrh, CCwp, CCrp, CCup) are settled as inert, in the factory too, so the configured warm-up and rest on the factory's measured timings are the model, and CCbp/CCbt are report-only tags that cannot appear in a header. The four actions the service has never been seen to send were read out of the factory binary: user_image is a lid capture and is implemented; update_check, factory_reset and head_firmware_update each hand off to a program this machine does not have (a factory updater, a reset script, a head firmware push), so each is answered on the wire and none is performed, and focus is ignored exactly as the factory ignores it. Declined outright: SPKI pinning, emulator full-session parity, and the factory's ten-event pause phase machine. Not inducible from the bench: the cancel-with-a-rejected-settings-action case, a malformed frame (needs a MITM), a body past the memory guard (the service has no such job to send), and a wedged feed (a healthy machine will not stall on request).

  6. Shared machine services — remaining polish. None of it blocking:

    • Diagnostics as engine modes. The flow tools still drive the thermal hardware themselves while the engine suspends its writes; the check parameters are already shared (cool.h), so what remains is folding the tools into the engine and retiring the suspend/resume dance.
    • Busy-state arbitration under one lock. The idle/busy gates (POST /settings, /mode, diagnostics start, upload/apply) each cross-check machine_is_idle() and update_job_running() at their own call sites. They fail closed and are drilled, but a single arbiter would close the remaining request-interleaving windows by construction.
    • HTTP surface caps. An explicit MHD_OPTION_CONNECTION_LIMIT plus a per-IP cap is the right hardening (a 500-connection flood plateaued at 379 fds under the raised 4096 RLIMIT_NOFILE, no crash), and the camera ensure_engine popen()s should move out of the HTTP callback so a slow media-ctl cannot stall the request thread. Changing the MHD start flags touches the streaming model, so this wants a bench slot of its own.
  7. Physical-evidence negatives still open. A present head answering I²C badly (the K-11 runtime case) and a failed head capture leaving the measure laser off — both need the head connected and a fault injected. Opportunistic: STATE_FAULT recovery via enable the next time a DRV8825 fault line actually trips.

  8. Debug-kernel checks. Module load/unload under CONFIG_DEBUG_MUTEXES and a forced -EPROBE_DEFER unwind still need a debug kernel build. Both drills cycle what the rail policy avoids: a module unload powers the 40 V rail off (a stepper driver can come out of the power-up unserviceable), and a forced defer needs the 40 V regulator or the SDMA device unbound under the module's probe. This is a bench slot with the rail-cycle gamble accepted, not a quick check.

  9. Wi-Fi SDIO CRC watch. The uSDHC pads now carry the factory-exact values and ship in every image. Watch dmesg | grep -c "sdio .* failed" across sessions (baseline: 1 event in 49 min of uptime). Effect if one lands mid-job: a 1–2 s sender stall — a cut-quality nuisance, never a safety matter. Only if it still recurs, cap the bus with max-frequency = <25000000> on &usdhc1 (halves Wi-Fi throughput — last resort; the factory ran 50 MHz on these pads).

  10. Release acceptance follow-through. The campaign is the release gate and runs as designed: dev image 20260824230512, 45 of 45 from nothing, 36 of them unattended with the bench actuator in the loop, release authorized (the export is on the board at /data/forgetest/export/). What is left is small. The ported bench tools are registered and unit-tested but not yet driven from the page. Two catalog gaps from the tool's own plan, cooling.confirm-escalate and cooling.fire-gate-blocks-arm, are not ported (both need the pump switched by hand mid-run, so they are bench-tab material first). From the coverage maps: splitting gfutilities' websocket.py into transport and transfer helpers would take websocket-transport changes off the offline tests (a gfutilities refactor, not a map). Tools that genuinely need a second host (LAN flood, remote auth probes) stay host-side by design, and the registry marks them so. The first release is item 11.

  11. Publish. The first release: releases/v<version>/acceptance.json from the authorized export, scripts/release.sh, the kas flip and the first GitHub release, per the site (Developers, "Release flow"), once ready to publish. Repoint the core submodule to upstream if the step_us_min sizing fix merges.

  12. Update system Phase 5 — recovery refresh. The remaining phase of docs/UPDATE-SYSTEM.md (a refreshed recovery image in boot0); Phases 0–4 are done.

  13. Head-IRQ source validation — beam-emission hypothesis (exploratory, not gating). The EV_SW head bit (GPIO3_22, factory pad HEAD_IRQ) is the head MCU's attention line — idle LOW with a healthy head, pulsing on head reboot, floating to the SoC pull-up with no head — so the raw level is not a presence signal (presence = the head answering at I²C 0x47). The factory app answers the IRQ by reading the head's flag register (reg 0x05: b0 hall_sensor, b1 accel_irq, b2 beam_detect_digital), so there are exactly three candidate sources; the working hypothesis is the head's IR beam-emission detector (digital flag + analog level reg 0x16, both already head sysfs attrs; the tunable detection model at regs 0x22–0x2a is not exposed). Whether the factory actually uses beam detect is unknown — the v2.6.0 app carries a complete but config-gated subsystem — and detection at low fire energies is unverified. Cheap opportunistic check during live fire: log EV_SW head-bit edges plus head/beam_detect_digital|_analog while firing.

  14. Gapless pause and resume in GRBL mode (planned). A pause leaves a mark in the cut. With laser mode on, the core stops the beam at the start of the hold (disable_laser_during_hold, on by default), so the head travels the whole deceleration dark, and the resume re-accelerates from a standstill at the point the decel ended — an unburned length, then a restart that dwells through the accel. At constant power (M3) that restart is a deeper spot you can see; M4 scales power with velocity and mostly hides it, but neither closes the gap. GRBL mode should pause and resume with no discontinuity in the cut, the way the factory does.

    Cloud mode already does, on the kernel's waypoint resume: controlled stop, laser-off backtrack (cloud_pause_backtrack_ticks 2000), then a laser-off lead back up to speed on the next press (cloud_resume_lead_ticks 1950), so the beam returns only once the head is retracing ground it already cut and is back at feed. The kernel offers that mechanism to a live feed as well: what bounds a backward run is the ring's retained history, not how the ring was filled, and the 32 KiB the writer must leave clear is 3.2 s of history at the print tick (cnc/max_backtrack, UAPI.md). What is not settled is the bookkeeping above it: a backward run moves the head and the kernel's counters while grblHAL's planner still holds a partly executed block, so borrowing the mechanism means reconciling the two, and a GRBL cut runs a much shorter queue than a cloud print does.

    So the equivalent likely belongs above the ring, where grblHAL still holds what the kernel does not: the planned path. Shape to evaluate: capture the point where the beam went off at the hold; on the resume plan a laser-off retrace back along the path and a laser-off accelerate-in, and unmask FIRE only once the head is at feed and has passed the captured point. Open: how far back is enough (2000/1950 ticks is a reference, not a transferable number — the tick rates differ), whether the retrace can reuse planner blocks or needs a synthesized one, what a hold inside an arc or a raster line does to it, and how it composes with the armed window's disarm grace across a long hold.

  15. Head crash and rail-contact detector (planned). The head accelerometer is the motion-liveness probe and nothing more; the factory runs two tiers off the same sensor (a per-axis alert that pauses, a per-axis abort), and its thresholds arrive in every pulse header in a unit and behind a filter that are not known. A detector here is bench-measured from scratch, not adopted from the header: the rail-contact signature in the facts bank (a 20 to 40 times jump within 4 ms on a fast strike, near-silent on a slow one) is the starting point, and the header values are only a cross-check once the units are established. A pause on contact, on the factory's shape, would be the first use.

  16. A sender change while a job runs: discussion. Today a sender that disconnects mid-job leaves the motion running to the end of what the controller holds, with the window closed and fire suppressed (the consent belonged to the displaced session), so the job finishes dark and the material is left with an unfinished cut. This is the stock Grbl and grblHAL expectation for the motion: the controller has no notion of sender presence, executes what its planner and RX ring hold, and then waits; the core's stream code (stream.c, stream_disconnect) only switches streams, with no hold and no alarm, and senders treat a lost connection as a failed job (LightBurn stops its own side and resumes nothing). ForgeFIRM adds only the disarm on top. The open question is whether the disarm should also feed-hold the job, so a reconnecting sender can press and resume where the cut stopped instead of finding the head at the end of a dark pass: a hold parks the head over hot material with the assist air on the run profile, and the grace then closes the window in Hold as it does today; running on leaves a clean stop position but wastes the piece. Decide with the gapless pause and resume item (14), which owns the resume mechanics.

  17. The flow check while the tube is lit. The arm-time heater check starts at the session open, so with a prompt press the tube is lit for most of its window, and a lit CW window adds about 1.5 C to the rise (0.5 C at 45 % density) against a 1.6 C margin; on top of that the engine takes its baseline from one sample while the coolant ADC carries a common-mode offset of about 1 C that steps in when the airflow goes to the run profile, steps out when it returns to idle, and toggles between two levels in between. Together they put an ordinary job's check within a few tenths of the limit. The engine now reads means and takes the tube's share off (cool_laser_heat_cw, cool_laser_heat_density), and cooling.flow-under-load is the catalog's case. Owed: a re-measure of the two coefficients once a second machine is on the bench (one tube, one supply so far); and if a lit check still trips, the void-on-emission design with the tube as its own flow tracer. The offset's source is the air-assist fan's return current on a ground path the thermistor reference shares (about 1.2 C at the run duty, proportional to the fan's current, both sensors alike; not crosstalk on the sensor cable and not HV). The check cancels it now that its baseline is taken under the run profile, but the over-temperature gates read the coolant about 1.2 C cooler than it is while the air assist runs unless cool_aa_offset_counts carries the machine's value (the aa-offset-calibrate diagnostic measures it, the panel's Apply writes it; zero is the factory's uncorrected reading; the bench machine carries 16). Owed: a second machine's value when one is on the bench; and the mid-run toggling between two levels (0.6 to 1.1 C, both sensors together), which comes only with the tube lit: not with the fans alone, not under motion, not in an armed dark window. The HV supply's input current on a return the thermistor reference shares, or its switching, is what remains; a scope on the two sensor lines during a cut is the next instrument. It sits inside the ceiling's 2 C hysteresis and the flow check reads means, so it is a measurement item, not a gate item.

  18. Laser power-good: what the line means. cnc/laser_pgood and its sampled count are defined in the UAPI (active low, one sample every ~3.9 ms), the facts bank records that the sampled count reads 0 through real cutting, and the cooling engine warns laser power-good degraded during the armed window whenever fewer than half the samples read low, so the warning fires at every session open and carries no information. Nobody knows what the line reports on this PSU: whether it is the supply's own power-good, an HV-present flag, a polarity we have inverted, or unconnected. Owed: the line on a scope against hv_current through an armed cut, its meaning written into the facts bank and the UAPI, and then either a warning that means something or no warning.

  19. Initial commissioning: measure and set the machine's own numbers methodically. Every tunable that was measured on the bench machine and shipped as a default varies from machine to machine: the flow check's bands and cool_flow_rise, the tube's heat coefficients (cool_laser_heat_cw, cool_laser_heat_density), the air-assist ground offset on the coolant readings, the laser's striking and lasing thresholds and the duty floor, the fan floors, the thermistor curve itself. Owed: one commissioning procedure, run once on a new machine from the panel or the bench page, that measures each of these in order with the tube dark wherever it can be, fires only where it must, and writes the results as that machine's settings with a record; and a reading of what the cloud sets for the same machine, taken from cloud cuts (the pulse header carries the factory's per-machine values), so the commissioning can start from the factory's own numbers where they exist and note where they differ from the measured ones. The dose-curve recorder (the panel's one-press ladder, fit and apply) is the first piece of this tool family and the template for the rest. Next piece, from the corner work: a side-by-side chooser - the tool cuts the same corner-heavy pattern at several settings of a knob (the corner rolloff first: a row of passes at, say, 1.0 / 1.25 / 1.5 / 1.75 / 2.0), labels them, and the operator picks the best by eye; Apply writes the winner. The rolloff is the proof case (this bench settled at 1.5 and may go lower, so the shipped default of 2 is a starting point, not a truth), and the same shape fits any by-eye tunable the commissioning flow meets.

Deliberately not gated: an armed GRBL job after an underrun cuts at the stale origin unless homing is required (GRBL mode permits unhomed cutting; the underrun itself alarms and unlinks the anchor). Not in the acceptance catalog by design, for the same reason. From the pulse-header envelope, each by decision and each declared in the cloud client so every job's log counts it as decided rather than missed: the warm-up fan profile (the run profile covers the warm-up hold), the supply temperature window (the service sends the whole ADC range and the factory binds it to nothing; the supply is watched per job instead), the head, lid, interconnect and fused temperature ceilings (no sensor at those locations; the chassis is watched per job), the head accelerometer thresholds (item 15), the lid IR thresholds (item 2), the HV current caps (the sampled emission witness covers the idle case, and HV current is ranged per job), the thermal report upload conditions and the pump flag. Beam detect stays with item 13.