cloud.pause-resume runs a print end to end, which is exactly what the job
lifecycle needs to be seen: a non-zero hold before the first fire, a non-zero
rest after the park, and neither on the connect-time hunt in the same
session. Folding the checks in there costs the operator nothing, where a
test of its own would cost another print.
The forgetest replay noticed first: it plays a real captured log from a build
that predates those lines. Rather than editing what the machine said that
day, the replay carries the two lines where the current build emits them.
BRINGUP's cloud item now names what is actually open on the header keys, the
park and the two periods, and records that the pause constants were looked
for in the wrong place.
A sweep of the whole catalog for the overlap the drill work found. The test
applied was "do these share a SETUP", not "do these share a subsystem":
combining only pays where a human waits - an arm press, scrap, a takeover,
a mode entry, a lid choreography - and it costs failure isolation, because
the campaign inherits per test and a merged test invalidates as a unit. The
17 auto tests were left alone for exactly that reason: they cost no operator
time and separate ids give the coverage map and the domain invalidation
finer teeth.
kernel.k3-unlock + kernel.fire-abu -> kernel.fire-line
Four phases behind ONE takeover of the pulse device instead of two:
A/B/U on the FIRE line, then the mid-ramp unlock. Same HV-not-good
gate, same zero duty, same safe state on the way out.
laser.expected-stop + laser.kill-mid-fire -> laser.armed-kill
Both ways an armed job is killed, on one scrap setup: the supervisor's
expected stop (with its separate operator-judged restart) and then a
SIGKILL of the restarted controller. The second phase re-reads the pid
after the restart, so it kills the process the supervisor just spawned.
laser.lid-cancel-mid-fire + laser.pause-resume-live -> laser.pause-resume-lid-cancel
One armed burn in the order the factory uses the machine's controls:
press (pause - emission stops, latch stays UNLOCKED, armed window
stays open), press (resume), lid (cancel, reset without alarm, return
to the job start, button latch SET). One arm press instead of two.
cloud.lid-abort + cloud.interlock-abort-park -> cloud.lid-interlock-abort
Two prints in one test: the lid, then the interlock with the lid opened
during the park. The tail both share - park complete, kernel counters
back at the job start, ':cancelled', latch locked, armed window closed -
is one helper now, so both triggers are judged the same way.
Not merged, though they share code: cloud.gfhome-homing and cloud.hunt-lid-open.
Both drive Machine._hunt (gfhome.py and gfcloud.py build the same gfhardware
machine, so the lid ungating is the same lines), but each is about the opposite
value of the same variable - gfhome's homing is camera-corrected and needs the
lid CLOSED in GRBL mode, the hunt test needs it OPEN through a cloud-mode
connect. Merging would put a mid-test mode switch back into the cloud tests.
Shared live-test prologue (the arm cue, the mark job, the wait for the emission
witness) and the post-kill trail/judging are helpers now.
Host proof: 104 unit tests - the merged cloud test replays the machine's own
lid-abort excerpt twice, once with the interlock substituted for the trigger,
and three negative cases hold it honest (loop already open, a park the lid can
interrupt, a stop that is not edge-driven) - and the coverage lint at 0
uncovered across 35 tests. Catalog time 137 -> 125 minutes, 96 of it attended.
Catalog 34 -> 39. Every remaining bench drill of the lid/button parity work
is now a test, with drills that exercise the same path combined:
motion.lid-cancel-home also cancels from a hold - a job paused on the
button is ended by the lid, never resumed - so the
armed window and the hardware button latch stay in
agreement by construction.
motion.cancel-abort also asserts what a sender abort must NOT do: it
stops where it stopped and never returns home. The
return-to-start belongs to the lid policy alone.
motion.interlock-cancel-park (new) the interlock loop cancels like the lid,
and the lid opened during the return home does not
interrupt it.
motion.lid-policy-hold (new) the other policy: Door park, no cancel, no
return, and a cycle start finishes the move. The
setting is restored on the way out.
laser.pause-resume-live (new) the button pause/resume during a live cut:
emission stops, the latch stays UNLOCKED and the
armed window open (a pause is not a cancel), the
next press resumes and the job finishes.
cloud.interlock-abort-park (new) the same interlock/park pair in cloud mode.
cloud.pause-cancel-paths (new) the two non-finishing ends of a print, each
from the state the factory ends it in: paused on the
button then cancelled by the lid, and cancelled from
the app while running.
The shared cancel tail (reason reported, reset without an alarm, position
kept, head back at the job start with the KERNEL counters confirming it) is
now one helper, so every trigger is judged the same way.
scripts/bench/resume_dark_lead.py: samples LASER_ON, FIRE, HV_ENABLE, the
charge-pump watchdog, the button and the doors off the SoC pads at ~2 kHz
through /dev/mem, with motion dated from the kernel step counters, across a
pause and a resume. Levels are taken at idle and everything after is reported
as a change from that baseline, so no polarity assumption is baked in. Dry by
default, with --auto driving the pause and resume through ! / ~ for an
unattended rehearsal; --run live adds the dark lead between FIRE and LASER_ON,
in milliseconds and in millimeters at the job's feed.
Bench registry: argument specs can name a flag (--feed 600) instead of being
positional, and an optional argument with an empty default is left off the
command line entirely.
Host proof: 104 unit tests (20 in the cloud suite - the two new cloud tests
replay the machine's own lid-abort excerpt, with the interlock and the app
cancel substituted for the trigger, and fail for the right reasons), coverage
lint 0 uncovered across 39 tests.
The cloud job tests (lid-abort, lid-during-button-wait, hunt-lid-open,
pause-resume) run in cloud mode and leave the machine there: enter_cloud
reuses a live session (pid-scoped from the client's own websocket state
lines) and switches once from GRBL mode, declaring the change to the
baseline; nothing switches back. Each test judges the log from its own
window, the print by its own "print [id]: finished" line, and waits the
service's follow-up moves out (wait_quiet) before it ends. hunt-lid-open
restarts the cloud client through the supervisor's stop/start lever for
a fresh connect. The former switch-back is what failed the last bench run
of hunt-lid-open (409 machine is not idle: the service was still
re-finding the head after the lid closed).
The baseline is mode-aware: in cloud mode the client owns the GRBL
controller's init values, the lid lamp, and the position counters; the
mode itself is preserved unless the run declared the change
(Context.mode_changed); controller_mode is never handed back as a bare
setting (a bare write left the persisted mode out of step with the live
one). The undeclared-change restore now uses the captured state, which
the post pass never saw before.
The acceptance page gets an "Ignore prerequisites" switch (remembered by
the browser): POST /start {ignore_requires} starts a test whose requires
are unmet, and the run records the unmet prerequisites in its evidence
and log; they stay required for the release. The cloud tests' requires
no longer chain through cloud.mode-switch.
Proof: tests/test_cloud_suite.py replays the four tests on the bench's
own gfcloud excerpts (fixtures/) and the run loop's emitted pause/resume
lines under the real runner Context against a fake forgectrl; baseline
mode tests and the server override test; the whole suite (98) and the
coverage lint pass. Catalog consequence: cloud.* fingerprints move with
the module; the catalog hash moves with the requires.
The lid-cancel tests (motion.lid-cancel-home, laser.lid-cancel-mid-fire)
now check that the KERNEL position counters returned to the job start,
not only grbl's MPos - grbl's drift read 0.000 while the head had not
moved. The baseline reports unplayed bytes queued in the kernel ring
(cnc/position total minus processed) as a leftover and refuses its
return jog while any exist: a run started on top of them replays them
first, which is what put the head into the rail. BRINGUP item 16 records
the bench finding and the stream-engine fix.
/mode reports controller=running at the spawn, so the reference dump
raced grblHAL's init writes and captured the supervisor's motion-probe
values (motor_lock 0, step_freq 10000, y_mode at the module default)
instead of the resting state. boot_reference() now waits for the
controller's markers (step_freq/motor_lock/y_mode at their fixed values,
bounded 20 s, GRBL mode only) plus a 1 s settle before dumping, retakes
a saved reference that shows the pre-config state while the boot is
still fresh, and marks it otherwise. Tests cover the wait, its timeout,
the non-GRBL no-op, the pre-config recognition and the retake.
The remaining bench diagnostics run from forgetest's #bench tab. The
tools that also run from a LAN host share scripts/bench/gfbench.py:
GF_HOST names a remote machine (host mode, sysfs through ssh, Grbl and
forgectrl over the LAN); unset, the tool runs on the board itself
(local mode, sysfs directly, everything on 127.0.0.1), which is how the
page runs them - with GF_HOST=127.0.0.1, the panel token in GF_TOKEN
and their data files under <data>/bench/ (FORGETEST_BENCH_DATA). The
helper also reads a machine setting from forgectrl, or from the settings
file on the board while forgectrl is stopped.
Ported: pwm_sweep / pwm_hold (scope = a takeover; the latch relocked,
the write refused if FIRE or LASER_ON reads active), pwm_stream_test
(PASS/FAIL exit), flow_characterize, flow_recheck_char,
flow_warm_validate and flow_matrix (takeovers: forgectrl owns the
thermal hardware, so the page's takeover replaces the tools' own
controller stop/restart, whose command line predated the supervisor;
results and logs in the bench data directory), flow_sustained,
fan_test, temp_calibrate (dry; watch bounded in seconds; the threshold
and the coolant conversion from the shared code), flow_escalate_drill
(cool_confirm_max_s shortened through forgectrl's settings for the
drill and restored; the setting's minimum is the default budget), and
live_fire_drills (<drill> [S] [F], all six drills, host from GF_HOST,
token from the board). flow_matrix joins the registry. What stays
unported cannot run against the machine at all: the two null-sink CI
harnesses and the .puls decoder.
Runner: a scope tool runs inside the takeover wrapper; the bench
environment above is passed to every tool. Tests: test_bench_registry
(registry <-> scripts/bench consistency, every ported tool builds its
command line, every script compiles, gfbench host/local modes) and the
server test (scope tool takeover, the environment reaching the tool).
Local mode smoke-run on the bench (temp_calibrate watch, setting, token)
from /tmp, removed after.
No catalog consequence: bench tools are not image components (dev-only
forgetest); the acceptance catalog is unchanged.
A component pin bump counted as a platform change: the layer content hash
in the platform identity covered the recipe carrying the SRCREV, the
platform is folded into every acceptance fingerprint, so every image
that carried any component update invalidated the whole catalog (dev
image 20260816191951: every test domain-changed after a one-line
forgectrl bump; the two manifests differ only in
platform.layers.meta-forgefirm). The component entry already identifies
the pinned source file by file; the pin double-counted it.
Component pins now live in <recipe>-pin.inc (SRCREV and the PV that
moves with it, nothing else) - forgectrl, grblhal-glowforge and
forgefirm-app here, the BSP components in meta-openglow - and
forgefirm-image-manifest.bbclass leaves *-pin.inc out of the layer
content (FORGEFIRM_MANIFEST_PIN_SUFFIX). Recipe bodies, patches, config
fragments, init scripts and third-party pins with no manifest entry stay
layer content; a pin written into a recipe body still hashes (the safe
direction). manifest-from-tree.py mirrors the rule and reads pins
through the recipe's requires; test_tree_manifest.py proves both
(pin bump: hash unchanged; recipe body or inline pin: changed).
Bitbake resolves the same SRCREV/PV for every pinned recipe.
Docs: ACCEPTANCE.md (what layer content is), kas/README.md (the pin
files in the push order), BRINGUP.md (the finding and the bench
consequence: the first image built with the pin files is itself a
platform change, so its campaign is a full one; pin bumps inherit
after it).
No catalog consequence: nothing in the image's behavior changes; the
change is to the acceptance identity computation, proven by the unit
tests and the CI lint on the tree manifest.
The lid lamp now has a resting policy in forgectrl (lid_lamp_idle,
default 236, asserted at start and at every spawn), so the baseline
expects it there instead of preserving whatever level a boot left, and
forgectrl.settings-bounds proves it: resting at the setting, 256 / -1 /
'bright' refused, a new level applied to the lamp at once, the cleared
key back to the default. Clearing a key goes through the query-string
form (an empty JSON value reads as no setting).
motion.liveness-probe adds the regression the bench needed: with every
axis masked (cnc/motor_lock=15, as a bench tool may leave it) forgectrl
is restarted and its fresh probe must read MOTION OK on the first try -
the probe unmasks the axes itself - and the controller comes up with the
mask cleared. Bench 2026-08-16: MOTION OK at p2p 2047/1341 against the
800 threshold, no ladder.
The baseline's settle no longer counts 'probe verified, spawn pending' as
settled (the post pass ran between the probe's own writes and the
controller's init writes and mis-flagged motor_lock/step_freq): it waits
for the controller to be running, with a bounded allowance for a respawn
backoff.
cloud.mode-switch took the optional connect-time firmware probe file as
the evidence of a live session and failed on a bench where that check is
off; the evidence is now gfcloud's own authenticate/ws-connect lines in
the unified log after the switch, the probe recorded when present. Cloud
mode's connect clears the kernel position counters at the head's start
and its hunt homes the head to the corner: the test tells the runner the
counters were re-zeroed (Context.counters_rezeroed) and jogs the head
back by the counter-measured displacement, and hands the lid lamp back
at the level it found. cloud.gfhome-homing documents that it leaves the
machine homed at the corner.
Baseline: a displaced head is jogged back along its own path by the
kernel-measured X/Y delta through the GRBL controller (bounded 100 mm,
waits out a controller respawn backoff); Z is never touched.
A baseline pass brackets every test and bench tool: before the run the
machine is verified against the fresh-boot idle state and anything off it
is restored; after the run - pass, fail, or abort - it is restored again.
Fixed items are the resting values the boot establishes (module defaults,
forgectrl's start-up writes, the GRBL controller's init writes) and
forgectrl's idle picture (controller running with motion verified, no
diagnostic, camera and cooling engines idle); preserved items (lid lamp
level, position counters, settings map, controller mode) are captured
before and handed back after. Deviations are leftovers: in the run pane,
in the result's evidence, and on the page - attributed to the previous run
when found before, to the run itself when found after.
forgetest takes a fresh-boot reference once per boot (within ten minutes
of boot, after the supervisor settles) as the session's resting lid-lamp
level and the check on the fixed values; the values were confirmed
against a fresh boot of the dev image on the bench (step_freq rests at
28160, the controller's default tick, not the probe's 10000).
Takeover runs capture the controller-owned kernel attributes on entry and
write them back before forgectrl restarts: the bench found the kernel
tests leaving motor_lock=15 behind, which masked the supervisor's
liveness probe - no motion by construction, a false driver-wedge verdict,
the rail-off ladder, and finally motion-fault. The takeover wrapper also
waits for the supervisor to settle on both sides (moved into baseline).
Catalog consequence: none beyond the runner; the tests' own drills are
unchanged.
forgectrl's supervisor probes motion liveness on every start - a small
head move verified by the accelerometer, with a rail-off ladder of up to
about 70 s on a dead verdict. The takeover wrapper returned as soon as
forgectrl start succeeded, so a test that followed found the machine
busy (bench: cooling.flow-verify refused with 409 machine is not idle
13 s after kernel.fire-abu), and back-to-back takeover tests stopped
forgectrl mid-probe. The wrapper now waits for /mode to settle - motion
verified, motion-fault (logged as a warning), or standby - before it
stops forgectrl and again after it starts it, giving up after 10 s when
forgectrl does not answer at all (the host, or a daemon that is down).
No catalog consequence: the takeover tests' own drills are unchanged.
A stdlib-only daemon on the dev image (HTTP :8090) that runs the acceptance
catalog against the machine from a self-contained page, keeps the append-only
result log under /data/forgetest, and exports the release artifact the gate
reads. Tests declare kind (auto / operator / live), hardware (api / takeover),
coverage globs, prerequisites, and core membership; a test's domain
fingerprint is the hash of the manifest files its globs select plus the
platform and its own implementation, so a PASS stays valid exactly while
nothing it covers changed. Campaign rules: a FAIL ends the campaign, the core
(image health, kernel latch and drills, one live emission witness) is never
inherited, invalidate-all forces a full campaign, no SKIP. Live tests need the
operator acknowledgment and the physical arm press through the controller;
takeover tests stop forgectrl for the duration with a crash-recoverable
marker; the tool never touches the laser latch.
Catalog v1: 24 tests ported from the proven bench drills with their recorded
pass criteria (image, kernel K1-K3 and fire A/B/U, forgectrl API and logs,
motion incl. dead-man, cooling, live laser, camera, update, cloud). The bench
tab lists every scripts/bench tool and runs the board-side ones as
subprocesses (takeover tools wrapped). 44 host unit tests, including the gate
verification fixtures. Installed only by forgefirm-image-dev, with the bench
scripts under /usr/share/forgetest/bench.