BRINGUP: lid-IR flame signature measured - a candle reads +3..6 counts, same as a cut
This commit is contained in:
+17
-6
@@ -263,9 +263,18 @@ worst cut rise, at the ~15-count floor); it is a hand-edited
|
||||
`/data/forgefirm.conf` key, **set on the bench 2026-08-15** (verified
|
||||
present, file 0600), and takes effect at the next run start — the fire
|
||||
watch is armed from here on and the next real jobs are the false-trip
|
||||
watch. A
|
||||
flame-signature measurement (tea light in the closed bed, idle) was not
|
||||
made; the gate stands on the cut data alone until one is. **Armed kill on
|
||||
watch. **Flame
|
||||
signature, measured the same day (machine idle):** a small candle burning
|
||||
on the bed under the closed lid read `38–41 / 38–41 / 42–45 / 42–45`
|
||||
against a lid-open level of `36 / 35 / 38 / 39` and a lid-closed-empty
|
||||
control of `34–37 / 34–36 / 36–39 / 37–40` — closing the lid changes
|
||||
nothing, the candle is **+3 to +6 counts on all four channels** for as
|
||||
long as it burns. That is the same size as a full-power cut's rise, so a
|
||||
threshold cannot separate a candle-sized flame from cutting and the
|
||||
15-count gate will not react to a flame that small; what a material fire
|
||||
of a size worth stopping for produces is unmeasured. The gate is kept
|
||||
(it costs nothing on normal cuts and catches anything large), and the
|
||||
lid-IR channels are recorded as a weak fire signal on this hardware. **Armed kill on
|
||||
the expected-stop path — first run FAILED, defect fixed, re-run PASS.**
|
||||
With emission live, `POST /controller/stop` returned only after 5.30 s
|
||||
and the operator saw ~17 mm / ~5 s of continued cutting before a
|
||||
@@ -2287,9 +2296,11 @@ accordingly ("Automatic — AP country, else World").
|
||||
2026-08-15** (three cutting-power jobs, worst rise +6 counts,
|
||||
`cool_fire_ir_delta = 15` set by hand in `/data/forgefirm.conf`).
|
||||
Still open from it: watch the next several real jobs for a false
|
||||
trip before calling the gate proven, and measure an actual flame
|
||||
signature (a tea light in the closed bed, machine idle) so the 15
|
||||
is anchored on both sides.
|
||||
trip. The flame signature is measured (candle: +3 to +6 counts,
|
||||
indistinguishable from a cut) — the gate cannot catch a small
|
||||
flame; only a large one. A better fire signal (the head camera,
|
||||
or a real IR flame sensor) is the honest next step if fire
|
||||
detection is to mean more than that.
|
||||