forgectrl pin a1875a8: cool_temp_critical_c (default 38 C) is the fail tier above the coolant ceiling's pause: at or over it in a run session the verdict is CRITICAL (fire blocked, hold, no resume this job), the fault ends with the session, the settings API keeps it above the ceiling, and its top turns the gate off. Catalog: cooling.critical-tier (auto, 45 tests), driven through the settings API like cooling.gate-off: a critical line at the ceiling is refused (and undone should it ever be accepted); with the ceiling, the resume gate and the critical line all under the coolant's temperature a session reads CRITICAL rather than OVERTEMP with no resume and the reason naming the tier and the coolant; after the session the ceiling alone holds (OVERTEMP); with the critical line at its top the gate is off (gates_off, the run-start log line) and the ceiling alone pauses; restored, OK with nothing off. Four unit cases against a scripted engine. _after_session takes the condition to wait for. Docs: COOLING (verdict table, section 5, the settings table, the quick reference), BRINGUP item 19 and the catalog count, the CAMPAIGN-LOG paragraph for the fan-fault session rule on dev image 20260822145201.