Files
forgefirm/forgetest
ScottW514 f51140e528 The coolant critical tier, with its catalog test
forgectrl pin a1875a8: cool_temp_critical_c (default 38 C) is the fail
tier above the coolant ceiling's pause: at or over it in a run session the
verdict is CRITICAL (fire blocked, hold, no resume this job), the fault
ends with the session, the settings API keeps it above the ceiling, and
its top turns the gate off.

Catalog: cooling.critical-tier (auto, 45 tests), driven through the
settings API like cooling.gate-off: a critical line at the ceiling is
refused (and undone should it ever be accepted); with the ceiling, the
resume gate and the critical line all under the coolant's temperature a
session reads CRITICAL rather than OVERTEMP with no resume and the reason
naming the tier and the coolant; after the session the ceiling alone
holds (OVERTEMP); with the critical line at its top the gate is off
(gates_off, the run-start log line) and the ceiling alone pauses;
restored, OK with nothing off. Four unit cases against a scripted engine.
_after_session takes the condition to wait for.

Docs: COOLING (verdict table, section 5, the settings table, the quick
reference), BRINGUP item 19 and the catalog count, the CAMPAIGN-LOG
paragraph for the fan-fault session rule on dev image 20260822145201.
2026-08-22 11:41:18 -04:00
..

forgetest - the ForgeFIRM release acceptance tool

The daemon behind http://<machine>:8090/ on the dev image: runs the acceptance catalog against the machine, keeps the append-only result log, decides which results still apply to the image that is running, exports the release artifact scripts/release.sh gates on, and serves the bench diagnostics page. The contract - catalog, campaigns, fingerprints, inheritance, the gate, the coverage rule - is docs/ACCEPTANCE.md.

Run the host tests

cd forgetest
python3 -m unittest discover -s tests -v

Run the daemon on a workstation (against a mock or a manifest file)

FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine>:8080 python3 -m forgetest --port 8090

scripts/manifest-from-tree.py produces tree-manifest.json from the recipe pins; the coverage lint is python3 -m forgetest.coverage --manifest ....

Environment

Variable Default Purpose
FORGETEST_DATA /data/forgetest results.jsonl, bench.jsonl, token, export/
FORGETEST_MANIFEST /etc/forgefirm-manifest.json the image manifest
FORGETEST_PORT, FORGETEST_HOST 8090, 0.0.0.0 listener
FORGETEST_BENCH_DIR /usr/share/forgetest/bench the installed bench scripts
FORGETEST_BENCH_DATA <FORGETEST_DATA>/bench passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN)
FORGETEST_MARKER /run/forgetest.active takeover marker
FORGECTRL_URL, FORGECTRL_TOKEN_FILE http://127.0.0.1:8080, /data/forgefirm/panel.token forgectrl client
GF_SYSFS_ROOT /sys/glowforge/ kernel module sysfs
GRBL_HOST, GRBL_PORT 127.0.0.1, 23 Grbl TCP

Adding a test

Register it in the subsystem module under forgetest/suite/ with @test(...): id subsystem.name, kind, hardware, mode (the controller mode the test needs; the runner switches to it first), covers, requires, always, steps. The body gets a Context (log, check, fail, prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs, grbl, takeover). Return normally for PASS, raise runner.Failed for FAIL. Then run the unit tests and the coverage lint.