#!/usr/bin/env python3
|
|
# Copyright 2026 514 LLC d/b/a OpenGlow
|
|
# Written by Scott Wiederhold
|
|
# https://community.openglow.org
|
|
# SPDX-License-Identifier: MIT
|
|
"""Characterize the coolant flow signature using the FACTORY temperature
|
|
curve, and recommend flow-fault thresholds.
|
|
|
|
The loop heater sits between the two water sensors; flowing coolant
|
|
carries its heat away, so downstream-minus-upstream settles at a small
|
|
stable delta. Stopping the pump lets that heat pool, and the delta
|
|
climbs. This measures both signatures and prints the separation.
|
|
|
|
Phases: baseline (heater off) -> flow (heater on, pump on) -> no-flow
|
|
(pump off) -> recovery (pump on). Restores heater off / pump on.
|
|
|
|
Drives the heater and pump directly, so it runs with forgectrl (the
|
|
thermal-hardware owner) and the controller stopped: the bench page's
|
|
takeover does that; from a host, stop them first. Runs on the board or
|
|
from a host (gfbench: GF_HOST).
|
|
|
|
Usage: flow_characterize.py [heater_pct] (default 10)
|
|
"""
|
|
import sys
|
|
import time
|
|
|
|
from gfbench import board, degc
|
|
|
|
|
|
def sample():
|
|
out = board('cat /sys/glowforge/pic/water_temp_1 /sys/glowforge/pic/water_temp_2').split()
|
|
if len(out) != 2:
|
|
return None
|
|
d, u = degc(int(out[0])), degc(int(out[1]))
|
|
return d, u, d - u
|
|
|
|
|
|
DOWN_ABORT_C = 45.0 # never cook the loop while characterizing
|
|
|
|
|
|
def phase(tag, seconds, interval=10, settle=0):
|
|
"""Log a phase; return the deltas after the settle period."""
|
|
t0 = time.time()
|
|
keep = []
|
|
while time.time() - t0 < seconds:
|
|
s = sample()
|
|
if s:
|
|
el = time.time() - t0
|
|
print(' %-7s t=%3.0fs down=%5.2f up=%5.2f dT=%+5.2f'
|
|
% (tag, el, s[0], s[1], s[2]), flush=True)
|
|
if el >= settle:
|
|
keep.append(s[2])
|
|
if s[0] >= DOWN_ABORT_C:
|
|
print(' ABORT: downstream %.1f C >= %.1f C safety limit'
|
|
% (s[0], DOWN_ABORT_C), flush=True)
|
|
board('echo 1 > /sys/glowforge/thermal/water_pump_on; '
|
|
'echo 0 > /sys/glowforge/thermal/heater_pwm')
|
|
break
|
|
time.sleep(interval)
|
|
return keep
|
|
|
|
|
|
def stats(name, ds):
|
|
if not ds:
|
|
print('%s: no samples' % name)
|
|
return None, None
|
|
print('%s: n=%d min=%+.2f max=%+.2f mean=%+.2f'
|
|
% (name, len(ds), min(ds), max(ds), sum(ds) / len(ds)))
|
|
return min(ds), max(ds)
|
|
|
|
|
|
heater_pct = int(sys.argv[1]) if len(sys.argv) > 1 else 10
|
|
heater_pwm = str(int(65535 * heater_pct / 100))
|
|
|
|
print('=== baseline: heater off, pump on (60 s)')
|
|
board('echo 1 > /sys/glowforge/thermal/water_pump_on; echo 0 > /sys/glowforge/thermal/heater_pwm')
|
|
base = phase('base', 60, 10, 30)
|
|
stats('baseline dT', base)
|
|
|
|
print('=== flow: heater %d%%, pump on (240 s; first 60 s ignored while dT establishes)' % heater_pct)
|
|
board('echo ' + heater_pwm + ' > /sys/glowforge/thermal/heater_pwm')
|
|
flow = phase('flow', 240, 10, 60)
|
|
fmin, fmax = stats('flow dT', flow)
|
|
|
|
print('=== no-flow: pump OFF, heater still on (150 s; first 20 s ignored)')
|
|
board('echo 0 > /sys/glowforge/thermal/water_pump_on')
|
|
noflow = phase('noflow', 150, 10, 20)
|
|
nmin, nmax = stats('no-flow dT', noflow)
|
|
|
|
print('=== recovery: pump on, heater off (90 s)')
|
|
board('echo 1 > /sys/glowforge/thermal/water_pump_on; echo 0 > /sys/glowforge/thermal/heater_pwm')
|
|
phase('recov', 90, 15)
|
|
|
|
print()
|
|
if fmax is not None and nmin is not None:
|
|
print('flow band: up to %+.2f C' % fmax)
|
|
print('no-flow band: from %+.2f C' % nmin)
|
|
if nmin > fmax:
|
|
fault = (fmax + nmin) / 2.0
|
|
print('separation: %.2f C -> suggested fault threshold %.2f C, re-arm %.2f C'
|
|
% (nmin - fmax, fault, fault - 0.4))
|
|
else:
|
|
print('BANDS OVERLAP - flow detection unreliable at %d%% heater; try a higher duty'
|
|
% heater_pct)
|
|
print('restored: pump on, heater off')
|