The lifecycle harness gains the state-files scenario: with GF_STATE_DIR at the session workdir, grbl.settings carries the $$ view and follows the derived floor through an M101 switch and its M2 revert, and grbl.state follows the sender connection (a reconnect bumps the generation), the armed window and the dose model, with ts_mono advancing. The panel-serves catalog test asserts the /status grbl block in GRBL mode with a live controller (fresh age, state, sender, laser, modals) and GET /grbl/settings, and its covers name the publisher and the serial layer; the glowforge_status.c covers entry selects nothing until the grblHAL pin moves past the commit that adds the file. The CAMPAIGN-LOG records the build and its proof; BRINGUP describes the mechanism.
1585 lines
104 KiB
Markdown
1585 lines
104 KiB
Markdown
# ForgeFIRM bring-up status & cold-start runbook
|
||
|
||
Last updated: **2026-08-26**.
|
||
|
||
This is the present state of the machine, the bench runbook, the measured
|
||
hardware facts, and the authoritative list of open work. **The dated record —
|
||
bench campaigns, drills, scope gates, the audit remediation, the acceptance
|
||
campaigns — is [`CAMPAIGN-LOG.md`](CAMPAIGN-LOG.md)**; come here for what is
|
||
true now, go there for how it was proven.
|
||
|
||
Read together with:
|
||
|
||
| Document | What it settles |
|
||
|---|---|
|
||
| `kernel-module-glowforge/UAPI.md` | the pulse-stream feeder contract, sysfs attributes, sensor conversions |
|
||
| `forgectrl/docs/SERVICES.md` | the machine-services contract: switch map, hardware ownership, cooling channels, mode supervision, pulse-device ownership, logging |
|
||
| `docs/SAFETY.md` | the hardware safing chain, decoded |
|
||
| `docs/VIDEO.md` | the cameras as users meet them: endpoints, delivered geometry, and what the sensors can do that ForgeFIRM does not send |
|
||
| `docs/LIGHTBURN.md`, `docs/UPDATE-SYSTEM.md`, `INSTALL.md` | sender setup, A/B update system, install |
|
||
| [docs.forgefirm.org/developers](https://docs.forgefirm.org/developers/) | build, release flow, tests, the bench runbook |
|
||
| `python3-gfhardware/forgefirm-app/docs/CLOUD.md` | cloud mode, including its own open items |
|
||
|
||
## Where the project stands
|
||
|
||
**The machine works, in both controller modes, and the whole stack is
|
||
hardware-validated.**
|
||
|
||
- **Platform bring-up: complete and hardware-verified.** SDMA + EPIT pulse
|
||
playback out of a reserved DMA pool, live-fed during a run; laser PWM at
|
||
39.98 kHz; `CONFIG_PREEMPT=y`; both OV5648 cameras on the mainline
|
||
imx-media pipeline with VPU JPEG encode; A/B slot install, signed `.fw`
|
||
releases and factory restore.
|
||
- **GRBL mode cuts real jobs.** grblHAL (the stock core plus one local fix, and
|
||
the ForgeFIRM driver) speaks Grbl 1.1f over TCP:23; LightBurn drives motion, the laser and the
|
||
camera stream. First light landed 2026-08-11.
|
||
- **Cloud mode runs the factory experience end to end**, deliberately kept
|
||
and maintained: sign-in, camera homing, prints, pause/resume, cancel.
|
||
- **forgectrl is the one machine-services daemon** behind both modes —
|
||
cooling engine, controller supervision, pulse-device broker, motion-liveness
|
||
gate, cameras, telemetry, settings, diagnostics, logging, updates, web panel.
|
||
- **Laser safety is hardware-first and bench-proven.** The chain
|
||
(`LID_SW1 & LID_SW2 & INTERLOCK & HV_OK & supplies-OK → OK_2_FIRE`,
|
||
`FIRE & OK_2_FIRE → LASER_ON`) gates the beam; the kernel latch, the
|
||
operator-armed window, the coolant fire gates and the dead-man chain sit on
|
||
top. GATE A (uncommanded energy) and GATE B (control surface + release) are
|
||
both closed.
|
||
- **Lid, interlock and button behave like the factory firmware** in both
|
||
modes (cancel-and-return on a lid or interlock open, button pause/resume),
|
||
bench-validated 2026-08-17.
|
||
- **Releases are gated by the acceptance tool** (`forgetest`, dev image only):
|
||
a 46-test catalog, domain-scoped inheritance, an always-required safety core,
|
||
a bench actuator that works the lid, the interlock and the button so most of
|
||
the operator's part runs unattended, and a release gate that reads the
|
||
exported artifact. The latest full campaign, on dev image `20260824230512`,
|
||
satisfied 45 of 45 from nothing in 27 minutes (36 tests unattended) and
|
||
authorizes a release; **no release is cut yet.**
|
||
|
||
Current bench state: dev image `20260824230512`, the board resting on the SD
|
||
dev image (eMMC slot 1 = factory 2024, slot 2 = ForgeFIRM v0.1.0, archives in
|
||
`/data/forgefirm/archive`).
|
||
|
||
## The bench
|
||
|
||
- **Board**: SSH `root@<machine-ip>` (dev images permit passwordless root
|
||
login). The bench machine is a **Basic/Plus** (the control board is common to
|
||
Basic/Plus/Pro). Dev image (`forgefirm-image-dev`) on SD; BusyBox userland +
|
||
python3 + gdb/strace. Serial console on ttymxc0 available at the bench.
|
||
- **Deploying kernels**: re-burn the SD with the freshly built
|
||
`forgefirm-image-dev-glowforge.rootfs.wic.gz` (deploy dir below). Why this
|
||
works: U-Boot (in eMMC boot0) reads the saved env at eMMC user-area 0x80000,
|
||
which selects the boot device (bench board: `mmcdev=0
|
||
mmcroot=/dev/mmcblk1p1` = SD), then loads `/boot/uEnv.txt` and `/boot/zImage`
|
||
from that rootfs partition — so the kernel always comes from the burned SD.
|
||
Full map: "eMMC boot & recovery architecture" in the facts bank below.
|
||
**Module-only changes hot-swap**: scp `glowforge.ko` over
|
||
`/lib/modules/<kver>/extras/`, then `rmmod glowforge && modprobe glowforge`.
|
||
NOTE: a module reload turns off the lid LED (relight via
|
||
`/sys/class/leds/lid_led*/target`) and resets the analog configuration, and
|
||
the first liveness probe after a reload can read NO MOTION until the ladder
|
||
re-probes.
|
||
- **Module hot-swap vs kernel re-stamps**: the hot-swap only loads if the
|
||
module was built against the FLASHED kernel's patch state. Any edit under the
|
||
kernel recipe's overlay (e.g. `glowforge.dts`) re-stamps
|
||
`CONFIG_LOCALVERSION_AUTO` — and the stamp does NOT reproduce by reverting
|
||
the edit (the kernel patch tree is a fresh git commit each `do_patch`, not
|
||
sstate-restored), so after any overlay edit the module can only ship with a
|
||
full image flash. **Kernel/BSP changes therefore ride one image flash,
|
||
batched**, and a `.ko` or overlay change is validated on the image that ships
|
||
it, never hot-swapped onto a board about to be reflashed.
|
||
- **Build host**: a Linux build environment (a WSL2 distro works) holding the
|
||
`forgefirm` + `meta-openglow` sibling checkout (the site, Developers,
|
||
"Build"); the ForgeFIRM
|
||
source repos are fetched by pinned `SRCREV`. Build:
|
||
`cd forgefirm && kas shell kas/forgefirm-glowforge.yml -c 'bitbake
|
||
forgefirm-image forgefirm-image-dev'`. Artifacts:
|
||
`forgefirm/build/tmp/deploy/images/glowforge/`.
|
||
- **fwup lab (host)**: a host directory (`<fwup-lab>`) holds host-built
|
||
`fwup-0.14.2` (factory-era) and `fwup-v1.16.0` under `bin/` and the DEV
|
||
signing keypair `devkeys/fwup-key.{priv,pub}` (`fwup-key-raw.pub` = raw
|
||
32-byte form — what fwup 0.14.2 expects; 1.x reads both). Cross-version
|
||
compatibility is proven both ways (modern-packed signed archives apply with
|
||
0.14.2; modern fwup verifies and applies the factory `.fw` — signer key
|
||
2017-05-001.pub). **The production release key is held offline by the
|
||
operator** — the installer embeds its public key, so releases sign with that
|
||
key only. Pack releases with `scripts/mkfw.sh`; the full pipeline is
|
||
`scripts/release.sh`, invoked as:
|
||
`FWUP=<fwup-lab>/bin/fwup-v1.16.0 FWUP_COMPAT=<fwup-lab>/bin/fwup-0.14.2
|
||
FORGEFIRM_DEV_KEY=<fwup-lab>/devkeys/fwup-key.priv
|
||
FORGEFIRM_SIGNING_KEY=<release key> RELEASE_STAGING_DIR=<dir>
|
||
./scripts/release.sh <version>` (the publish step needs an authenticated
|
||
`gh`; release.sh prints the exact command).
|
||
- **Bench hygiene**: stage test files in `/tmp`; anything that must survive a
|
||
reboot goes in `/data/bench-scratch/` and that directory is deleted whole at
|
||
the end of the session. Bench tools worth keeping live in
|
||
`forgefirm/scripts/bench/` and ship on the dev image under
|
||
`/usr/share/forgetest/bench/`.
|
||
- **Shell gotchas** (cost real time): PowerShell mangles embedded double quotes
|
||
in git-commit here-strings (avoid `"` in messages); `wsl -- bash -c '...'`
|
||
eats `$VAR` expansions (use script files run via PowerShell, not Git Bash,
|
||
which MSYS-mangles `/mnt/c` paths).
|
||
|
||
## Running the controller (grblHAL-glowforge on the board)
|
||
|
||
Source: the `grblHAL-glowforge` sibling repo — the **canonical grblHAL driver
|
||
repo** (github.com/ScottW514/grblHAL-glowforge, branch `main`): core as a
|
||
submodule at `src/grbl` (→ ScottW514/core fork, branch `forgefirm` = upstream
|
||
master plus one local commit, the `step_us_min` buffer sizing that keeps a
|
||
fortified build from aborting in `settings_init`; the settings-write crash fix
|
||
merged upstream 2026-08-04 as grblHAL/core PR #999). `driver.c` implements the
|
||
HAL; machine constants live in `src/boards/glowforge.h`.
|
||
|
||
**The controller is spawned and supervised by forgectrl**: the supervisor
|
||
starts the controller selected by `controller_mode` (grbl | cloud) as a direct
|
||
child, respawns it on a crash (after safing the machine), and switches modes
|
||
live via `POST /mode` / the Status-tab selector. The `grblhal` and `gfcloud`
|
||
init scripts defer to it (they remain as manual emergency levers, routed
|
||
through `POST /controller/stop|start`). The pulse device arrives as a
|
||
broker-inherited fd (`GF_PULSE_FD`) — the device never closes across mode
|
||
switches, homing handovers or respawns, so the 40 V rail never cycles as a side
|
||
effect — and the supervisor verifies **physical motion** (head-accelerometer
|
||
liveness probe) before the first controller spawn of each session.
|
||
|
||
Architecture: a wall-paced producer thread runs the core stepper ISR against a
|
||
virtual step clock (1000× machine tick) and maps step events to pulse bytes; a
|
||
SCHED_FIFO shipper feeds `/dev/glowforge` through a bounded queue; a recursive
|
||
core mutex stands in for interrupt masking. `GFSINK` unset = null-sink mode
|
||
(full engine, no hardware I/O — host testing and CI).
|
||
|
||
1. Build: `bash <repo>/forgefirm/scripts/bench/build-glowforge.sh` in the build
|
||
environment (from Windows, launch it through the WSL distro from PowerShell
|
||
— Git Bash mangles `/mnt/c` paths). Produces `build-arm/grblHAL_glowforge`
|
||
in the checkout (`-O1 -g`; machine constants force-included into the core:
|
||
53.333 µsteps/mm XY @ ×8, 2.832 half-steps/mm Z, 0.417" Z travel,
|
||
12000 mm/min max, 700/590 mm/s² accel — factory-derived, see
|
||
`puls_profile.py`).
|
||
2. Deploy: move the new binary over `/usr/bin/grblHAL_glowforge` (mv replaces
|
||
the inode, so the running instance is untouched), then kill the running
|
||
controller — the supervisor respawns it on the new binary within about a
|
||
second.
|
||
3. Standalone start (bench/debug only — requires forgectrl stopped, since the
|
||
broker's exclusive hold on `/dev/glowforge` makes any self-open fail EBUSY):
|
||
`cd /data && GFSINK=/dev/glowforge grblHAL_glowforge -p 23 -e
|
||
/data/EEPROM-glowforge.DAT`. Env knobs: `GFSINK_RATE` (machine tick, default
|
||
28160 Hz = factory travel tick), `GFSINK_DEPTH_MS` (queue depth = feed-hold
|
||
latency, default 200). Standalone, the driver opens the device itself and
|
||
every takeover runs the `rail_settle_s` off-period; under the broker it
|
||
inherits the fd and skips the settle (the rail never dropped). The driver
|
||
applies the full analog machine config at init either way (×8 modes, decay 1,
|
||
motor_lock 8, laser latched, PIC hold currents) and swaps PIC run/hold
|
||
currents around motion. Each motion run logs a producer-stats line
|
||
(callbacks, µs/call, max-behind, clamped) — `clamped` should stay 0.
|
||
4. Connect LightBurn/UGS to `<machine-ip>:23`, or jog raw: `$J=G91X40F1200`.
|
||
`^X` mid-motion aborts via kernel `cnc/stop` (controlled decel) and raises an
|
||
alarm; TCP disconnects never kill the process (the dead-man fd stays held).
|
||
|
||
**Spindle `$`-settings take effect at controller start.** The core
|
||
precomputes the S -> duty mapping once, when the spindle is enabled, and a
|
||
settings write does not re-run it: `$35=16` persists to the eeprom
|
||
immediately and `$$` reports it immediately, but the mapping in force is
|
||
still the one loaded at start until the controller restarts (a mode switch,
|
||
a `POST /controller/stop` + `start`, or a boot). Verified host-side: after a
|
||
runtime `$35=0` the shipped duties stay floored.
|
||
|
||
**Stored `$`-settings beat freshly baked defaults** — after changing
|
||
`GLOWFORGE_DEFAULTS` values, run `$RST=$` once on the board (settings persist
|
||
in the eeprom file in `/data`).
|
||
|
||
**Protocol-loop pacing is fd-blocking.** `serial_wait()` drains TX then
|
||
`ppoll()`s the listen/client fds with a state-dependent timeout: idle and alarm
|
||
at 10 ms (1 ms while a delay callback is pending), motion at 200 µs, and the
|
||
parked states — a completed feed hold, a parked door ajar or closed, and sleep
|
||
— at the coarse idle poll, while the motion sub-phases (`Hold_Pending` decel,
|
||
`Parking_Retracting`/`Resuming`) keep the tight pace. Measured on the bench:
|
||
idle 2.7 %, active move 34–35 %, parked 2.7–3.0 %. Client RX is armed only
|
||
while the ring has a full read's worth of room, so a flow-control-violating
|
||
sender is paced, not spun on.
|
||
|
||
## Laser control (GRBL mode)
|
||
|
||
The real spindle lives in `grblHAL-glowforge/src/glowforge_laser.c`.
|
||
Per-segment spindle updates (the core's laser-mode path, on the stepper
|
||
producer thread at exact virtual-tick positions) map power and fire transitions
|
||
onto the pulse-byte grid via `gf_stream_laser()`, and the shipper emits them: a
|
||
power byte (`0x80 | 7-bit duty`, raw PWMSAR counts, 127 = 100 %) inserted ahead
|
||
of the first tick byte it covers, FIRE as bit 4 OR'd into tick bytes. The
|
||
spindle PWM is precomputed to a period of exactly 127, so computed values ARE
|
||
power bytes (`$30` default 1000 → S1000 = 127).
|
||
|
||
**Dose model.** Two models render the per-segment value the core computes:
|
||
`density` (the default) pins the duty at full and modulates the FIRE bit,
|
||
`analog` ships the value as a power byte instead. Density uses a base
|
||
period of `laser_pulse_ticks` (default 20 = 710 us at 28160 Hz, the
|
||
factory's ~1.43 kHz) whose on-count is dithered between adjacent integers
|
||
with the remainder carried, so densities finer than one tick per period
|
||
average out. Density is what the tube's dead band below its lasing
|
||
threshold requires: every pulse it emits is full-power, so no commanded
|
||
level lands in the band, and a level change inside a run costs no stream
|
||
byte at all. `laser_pulse_min_ticks` (default 3 = 106 us) is the shortest
|
||
pulse it will emit: below it a period is skipped and its debt carried, so a
|
||
faint level arrives as fewer full-width pulses instead of stubs the supply
|
||
cannot strike - measured on the bench, a 36 us stub draws no discharge at
|
||
all, and the factory never emits below one of its 100 us ticks. The debt is
|
||
conserved, so the average density is unchanged: at level 2 the stream goes
|
||
from 444 one-tick bursts to 147 three-tick bursts, same density to four
|
||
decimals. Structurally the model is a mask on the core's fire state and
|
||
never a source of one, so emission stays exactly where the core commanded
|
||
it.
|
||
|
||
**Selecting the model.** `laser_power_model` in the shared machine config
|
||
(the control panel's GRBL tab) is the boot default. A job selects its own
|
||
with the driver M-code `M101 P0` (analog) or `M101 P1` (density), sent with
|
||
the spindle off: the switch is refused (`error:253`, reason reported) with
|
||
the spindle commanded on or the controller not idle, because a model change
|
||
under fire could pair density's pinned full duty with analog's continuous
|
||
FIRE; between kernel runs, which end dark and lead with a power byte, there
|
||
is no torn state to reach. The planner drains before the switch, the armed
|
||
window stays open across it, so `M5` / `M101` / `M3` inside a job switches
|
||
models between its sections with no new press. The switch is
|
||
program-scoped: it reverts to the boot default at `M2`/`M30` and on a soft
|
||
reset, so a job header can declare the model it needs without leaving the
|
||
machine in it; `M101 P<n> Q1` sticks until the next switch or a controller
|
||
restart. The stream leads the first run after a switch dark (duty 0) until
|
||
the commanded power lands, so neither model's number is ever shipped under
|
||
the other.
|
||
|
||
**The floor is derived, never typed.** Each model has an S-range floor as a
|
||
config key: `laser_floor_density` (default 10, the lowest density that
|
||
still marks, putting a commanded 1 % at 10.2 % density) and
|
||
`laser_floor_analog` (default 16, the duty this tube lases at; 3 to 14 % is
|
||
a dead band). At every arm and every switch the controller loads the
|
||
selected model's floor into `$35` in RAM and re-precomputes the PWM
|
||
mapping; the stored `$35` is never written, `$$` reports the floor in
|
||
force, and a `$35` typed by a sender is overwritten at the next arm. The
|
||
arm and switch reports name both (`laser armed (density, floor 10 %)`,
|
||
`laser power model set for this program (analog, floor 16 %)`), and a floor
|
||
of 0 is honored with a note (the ladders run that way). The cooling report
|
||
carries the model in force (`model=` on `POST /cool/state`) so the engine's
|
||
tube-heat share follows an `M101` as well as the default.
|
||
|
||
**Measured dose response (this bench, 2026-08-30, by the head thermopile,
|
||
the tube current and the operator's eye on Thick Draftboard and acrylic).**
|
||
Density delivers about half of the CW light at 80 % density, a third at
|
||
60 %, a fifth at 45 % and a fourteenth at 30 %: the curve is the tube's
|
||
(pulsed against CW), not the sensor's, and it is the same physics behind the
|
||
factory's 18.9 to 79.5 % mapping with Full Power kept apart. Analog is
|
||
close to linear above 30 % duty (0.82 / 0.68 / 0.54 / 0.37 of CW at 80 /
|
||
60 / 45 / 30 % duty, the tube current equal to the duty) with the lasing
|
||
knee at 20 to 23 % duty below that. The finish on acrylic is the same under
|
||
both models, and the only visible pattern is mechanical (present under CW
|
||
too), so the models differ in their S scale, not their mark. A per-model S
|
||
correction (E4 in the working file) is the open item that follows.
|
||
|
||
An S word takes effect whether or not motion is in progress. Per-segment
|
||
updates carry the level inside a laser block, but an S executed between
|
||
blocks - with the planner drained, so nothing is streaming - arrives only
|
||
through the synchronous spindle path, which publishes the duty without
|
||
touching the fire state; and the next run re-asserts the laser state the
|
||
core last asked for at its first byte, fire only inside an armed window.
|
||
Without those two a standalone S from a sender slow enough to drain the
|
||
planner left the following moves cutting at a stale duty, or dark.
|
||
|
||
Contract rules enforced structurally: a power byte leads every kernel run
|
||
before any fire bit (a run start resets duty to ~100 %), transitions are
|
||
coalesced per tick so power bytes are never consecutive, and power bytes cost
|
||
no machine tick. Fire only ever rides motion segments of laser blocks — jogs,
|
||
G0 and homing are fire-free by construction — and the end-of-data backstop
|
||
covers every stream end. **Duty persists after end-of-data** (PWMSAR retains
|
||
its last value): the laser-off guarantee rests entirely on FIRE.
|
||
|
||
**Arming — the operator's button press is required.** The first laser-on of a
|
||
job (M3/M4, planner-synced) refuses outright if a coolant fire gate stands or
|
||
if no head is detected (`ALARM:3`, "laser fire blocked: no head detected"),
|
||
else forces the run fan profile on, unlocks the kernel laser latch, lights the
|
||
button white and blocks the gcode stream — pumping real-time traffic — until
|
||
the operator presses the physical button (EV_SW bit 2), a soft reset aborts, a
|
||
lid or interlock open cancels, or `laser_button_timeout_s` (default 300 s)
|
||
expires into alarm 3. The coolant verdict is re-checked immediately after the
|
||
wait, before the window opens. The armed window survives S changes and M5/M3
|
||
toggles (no re-prompt mid-job) and closes — relocking the latch — at program
|
||
end (`M2`/`M30`/`%`), when the sender connection changes, after
|
||
`laser_disarm_s` (default 60 s) of spindle-off idle, or immediately on
|
||
alarm/homing/reset/stream fault. The disarm grace counts down in Hold, Door and
|
||
Tool Change too. Both keys live in the shared machine config, re-read per arm.
|
||
|
||
**Underrun policy while armed: fail safe, no retry.** The stop/run recovery
|
||
restarts the kernel run, which resets duty to ~100 %, so replaying queued fire
|
||
bits would fire at full power: an armed underrun acks the kernel and faults
|
||
(alarm, latch relock, homing anchor unlinked). Motion-only streams keep the
|
||
one-shot retry.
|
||
|
||
**Coolant fire gates live** (`gfcool_fire_ok`): a flow FAULT or an over-ceiling
|
||
coolant temperature blocks arming and suppresses fire mid-job with a loud
|
||
warning. While armed, the run fan profile and flow interrogation are forced on
|
||
regardless of the sender's M8/M9; a SUSPECT/FAULT verdict inside an armed
|
||
window takes the safe posture (feed hold + run airflow). SUSPECT auto-resumes
|
||
on a clean re-check; FAULT leaves the hold and the gate for the operator.
|
||
|
||
**The controller publishes its state for the daemon.** forgectrl can
|
||
never open the Grbl socket (a connection displaces the sender), so the
|
||
controller writes two files under `/run/forgefirm`, atomically, on
|
||
edges: `grbl.settings` (the `$$` view, rewritten on every setting
|
||
change, the M101 switch included) and `grbl.state` (JSON: machine state
|
||
and alarm, the sender session with peer and generation, the laser's
|
||
armed window and dose model with its floor, the exact `[GC:...]` modal
|
||
report, overrides, driver version, `ts_mono` for age; on change plus a
|
||
5 s heartbeat). forgectrl echoes the state file in `GET /status` as the
|
||
`grbl` block only while it supervises a live GRBL controller, serves
|
||
the settings file at `GET /grbl/settings`, and the panel's GRBL card
|
||
renders it. Position stays out: it changes per segment and is served
|
||
from the kernel counters. Contract: `forgectrl/docs/SERVICES.md`.
|
||
|
||
**Emission evidence.** `cnc/laser_on_sampled` (surfaced as `/status`
|
||
`laser.emission_samples`) is the reliable live-emission witness; emission
|
||
sensed with no armed window relocks the latch and stops motion. `pic/hv_current`
|
||
is the only live HV telemetry on this PSU. `cnc/laser_pgood_sampled` is **not**
|
||
a usable witness here — it reads 0 through real cutting.
|
||
|
||
## Lid, interlock and button policy
|
||
|
||
Both controller modes react the way the factory daemon does (decoded from a
|
||
factory 2.6.0-2228 session; measured numbers in the facts bank).
|
||
|
||
- **Lid or interlock open during a job, running or paused:** motion stops
|
||
within milliseconds of the edge, the job is **canceled and not resumable**,
|
||
the head returns to the position the job started from **with the lid still
|
||
open**, the kernel latch relocks and the armed window closes. The
|
||
return-home park ignores the lid and always runs to completion. The next job
|
||
re-arms with a button press — the same press the hardware button latch needs,
|
||
so software and hardware agree by construction.
|
||
- **During the pre-run button wait:** a lid or interlock open cancels the job
|
||
with the reason named (clean soft reset, no alarm); a press with the lid open
|
||
never arms.
|
||
- **Ignored:** a lid open during a hunt, homing, a jog, or at idle.
|
||
- **The button pauses and resumes a job.** Cloud mode uses the factory's
|
||
laser-off backtrack and resume lead (`cloud_pause_backtrack_ticks` 2000 /
|
||
`cloud_resume_lead_ticks` 1950), on a preloaded job and a live-fed one
|
||
alike: the retrace is sized to `cnc/max_backtrack` and the lead follows it,
|
||
so a pause with little history behind it shortens both rather than failing.
|
||
GRBL mode uses feed hold / cycle start, so a resumed GRBL cut picks up where
|
||
the deceleration ended (item 17). A pause is not a cancel: the latch
|
||
stays unlocked and the window open across it. There is no resume dwell: the
|
||
safing chain re-arms ~216 ms before the first step (facts bank).
|
||
- **`lid_policy = hold`** selects stock grblHAL door behavior instead (park in
|
||
Door, cycle start after the lid closes resumes with position intact).
|
||
|
||
Switch mapping (`grblHAL-glowforge/src/glowforge_switches.c`; the controller
|
||
reads EV_SW with `EVIOCGSW` from the protocol thread's realtime hook, no grab):
|
||
doors = bit 3 (the series combination the safety chain itself uses), remote
|
||
interlock = bit 5 (inverted sense), button = bit 2. The door signal is hidden
|
||
from the core while it is IDLE, JOG or HOMING (`gfsw_visible`) so a lid cycle at
|
||
idle cannot park the controller in `Door:0` and leave a sender waiting.
|
||
**hv_enable (bit 4) is never gated on** — it is the readback of the chain's
|
||
HV_ENABLE output, telemetry only. **The interlock latch (bit 6) is not gated on
|
||
either** — the hardware chain enforces it. No switch device (host builds) = no
|
||
capability advertised. `GF_SWITCH_FILE` is the file-backed EV_SW word that lets
|
||
null-sink builds drive these edges in CI.
|
||
|
||
## Homing
|
||
|
||
Runtime-selectable through `homing_mode` in `/data/forgefirm.conf` (forgectrl
|
||
`GET/POST /settings`, panel selector); the driver re-reads the file on every
|
||
`$H`:
|
||
|
||
- `gfcloud` — factory camera homing via the Glowforge web service. **Live
|
||
verified**; a full cycle runs in 50–65 s.
|
||
- `switches` — the planned limit-switch cycle (falls through to the core, still
|
||
disabled `$22=0`).
|
||
- `none` — `$H` rejects with error 5.
|
||
|
||
Architecture: `glowforge_homing.c` registers a driver `$H` that shadows the
|
||
core's; for gfcloud it suspends the stream engine (only from a fully idle
|
||
kernel — closing the flock'd fd mid-program is an e-stop), spawns
|
||
`/usr/sbin/gfhome.py` (config `/data/etc/gfhome.conf`, first-run copy from
|
||
`/etc/gfhome.conf.sample`), pumps the protocol so senders keep getting status,
|
||
then reacquires the device and re-applies the analog config and `step_freq`.
|
||
`^X` aborts the session (SIGTERM → SIGKILL); failure or timeout queues
|
||
`ALARM:18` like a failed core cycle (`gfcloud_home_timeout_s`, default 300).
|
||
The runner drives the GFUIService dispatch itself (the stock `run()` loop can
|
||
neither stop nor close the socket) and treats hunt + ≥1
|
||
accelerometer-witnessed motion window + quiet (10 s) as complete — the modern
|
||
v2.6.0 sequence, captured from a live service session, is settings → hunt → lid_image
|
||
→ single corner move → lid_image → silence. It then re-homes
|
||
the lens against the hall for a deterministic Z. **A quiet service without an
|
||
accel-witnessed motion window is a failure, not a homing.**
|
||
|
||
Position semantics: factory home = machine origin (back-left corner, +Y =
|
||
FRONT, workspace all-positive 0..495 × 0..279); Z top-of-travel = 10.6.
|
||
`gfcloud_home_x/y/z` calibrate the post-home coordinates once measured
|
||
(defaults 0 / 0 / Z max). GRBL mode permits unhomed cutting — position shows
|
||
counters-only and painted red until anchored.
|
||
|
||
## The machine-services daemon (forgectrl, port 8080)
|
||
|
||
Source: the `forgectrl` sibling repo (github.com/ScottW514/forgectrl, branch
|
||
`main`, MIT). It is the ForgeFIRM machine-services daemon: **controller-mode
|
||
supervision**, the **pulse-device broker**, the **motion-liveness gate**, the
|
||
**cooling engine** (single owner of fans/pump/TEC/heater for both modes), plus
|
||
cameras, telemetry, settings, diagnostics, the web panel, updates and the
|
||
**logging tree**. It runs under a respawn wrapper (its init script); a
|
||
restarted daemon retakes supervision once the machine is idle — an unmanaged
|
||
controller left running mid-move is replaced at idle, not adopted (the old
|
||
inherited fd cannot be taken over). The meta-forgefirm recipe pins its SRCREV
|
||
in `forgectrl-pin.inc` (bump deliberately after pushing) and installs the
|
||
sysvinit script from the repo's `init/`; bench builds cross-compile with
|
||
`forgefirm/scripts/bench/build-forgectrl.sh`. The **machine-services
|
||
contract** — EV_SW switch map, sensor conversions, hardware single-writer
|
||
ownership, cooling channels, mode supervision, pulse-device ownership, logging
|
||
— is `forgectrl/docs/SERVICES.md`.
|
||
|
||
Every state-changing endpoint requires the first-boot bearer token in `/data`
|
||
(embedded in the panel), a Host address-literal check, and
|
||
`Sec-Fetch-Site`/`Origin` validation (CSRF and DNS-rebinding refusal).
|
||
`/cool/state` is loopback-only. `/fuse-identity` and unsigned-firmware installs
|
||
additionally require the physical button held.
|
||
|
||
One ulfius daemon serves it all:
|
||
|
||
- `GET /` — the tabbed control panel (**Status / Machine / GF Cloud / GRBL /
|
||
Diagnostics / Logs / System**; sources in `forgectrl/src/ui/`,
|
||
`index.html` + `panel.css` + `panel.js`, bundled into the binary by
|
||
`embed.cmake`; `tools/devserver.py` and the repo's `.devcontainer/` serve the
|
||
same panel on a workstation against a live board or a mock). Status carries
|
||
the controller-mode selector, the operational dashboard, a scaled lid
|
||
snapshot and an on-demand live stream; System carries A/B slot selection,
|
||
ForgeFIRM updates, image install/restore, the wireless regulatory region and
|
||
reboot. All settings controls disable (with a banner) while the machine is not
|
||
idle **or a diagnostic is running**. `/?action=stream|snapshot` remain the
|
||
mjpg-streamer-compatible aliases (lid camera; LightBurn uses the stream one).
|
||
- `GET /status` — motion state and true machine position (kernel step counters
|
||
anchored at homing via `/run/grblhal.homed` — the Grbl socket is never polled,
|
||
a connection there displaces the sender), coolant temps, pump/TEC, all four
|
||
fan tachs, the sensed laser evidence (emission samples, HV current, lid IR),
|
||
faults, the safety switches via `EVIOCGSW` (head = real presence, i.e. the
|
||
head sysfs group exists), and a `diag` flag for the UI lock.
|
||
- `GET/POST /settings` — the shared machine settings store
|
||
(`/data/forgefirm.conf`, 0600, validated keys, empty-value-clears via query
|
||
params; `gf_password` write-only). **Writes 409 unless `cnc/state` is idle**
|
||
and 409 while a diagnostic owns the hardware; a multi-key POST lands as one
|
||
atomic replace. Keys: `controller_mode`, `homing_mode`, `gfcloud_home_x/y/z`,
|
||
`gfcloud_home_timeout_s`, `gf_serial`, `gf_password`, `ui_units`,
|
||
`wifi_country`, the nine `cool_*` tunables, `laser_button_timeout_s`,
|
||
`laser_disarm_s`, `rail_settle_s`, `lid_lamp_idle`, `lid_policy`,
|
||
`cloud_pause_backtrack_ticks`, `cloud_resume_lead_ticks`, the twelve
|
||
`log_<logger>_disk|_remote` levels and `syslog_server|port|proto`.
|
||
`cool_fire_ir_delta` is a hand-edited conf key, not a panel setting.
|
||
- `GET /mode`, `POST /mode?controller=grbl|cloud` — the supervisor: current
|
||
mode, controller state (`running | stopped | standby | motion-fault`), pid,
|
||
and the motion-liveness verdict (`verified | unverified | fault`); the POST is
|
||
the live idle-gated mode switch and the retry lever after a motion fault.
|
||
- `POST /controller/stop|start` — the routed emergency levers the init scripts
|
||
use. Stop writes `cnc/stop` + `cnc/laser_latch=1` **before** the SIGTERM
|
||
(kernel-level, instantaneous) and holds supervision suspended.
|
||
- `POST /cool/state` (job-state reports from the active controller, level-
|
||
triggered ~1 Hz) and `GET /cool/status` (engine phase, verdict, temps, report
|
||
age). The verdict the controllers enforce is the
|
||
`/run/forgefirm/cooling.state` file.
|
||
- `POST /diag/flow-verify|flow-calibrate|abort`, `GET /diag/status` — the
|
||
diagnostics runner (below).
|
||
- `GET /cam/stream?cam=lid|head` — multipart MJPEG at half the sensor's frame
|
||
in each axis, 1296×972 on a 5 MP machine (2×2 Bayer-superpixel demosaic,
|
||
JPEG q75; `FORGECTRL_STREAM_Q` overrides, `FORGECTRL_STREAM_FPS` caps the
|
||
frame rate, unset/0 = sensor max).
|
||
- `GET /cam/snapshot?cam=lid|head&res=full|half&q=1..100` — single JPEG,
|
||
default the sensor's full frame, 2592×1944 on a 5 MP machine (own MIT
|
||
bilinear demosaic).
|
||
- `GET /cam/status` — JSON (running/cam/clients/frames/fps/fps_cap/encoder/
|
||
buffers/sensor, the stream + snapshot geometry the fitted sensor implies,
|
||
and the privacy gate's `capture_allowed` / `stopped_by_lid`). Stream and
|
||
snapshot answer 409 while the lid is open.
|
||
- `GET /slots`, `POST /boot`, `POST /update/check|download|apply|upload`,
|
||
`GET /update/status`, `POST /restore/factory`, `POST /system/reboot` — the
|
||
A/B update manager (`docs/UPDATE-SYSTEM.md`). Upload is auth + idle + job
|
||
gated; a booted-slot write is refused under any `root=` spelling.
|
||
- `GET /logs`, `GET /logs/tail`, `POST /logs/export` — the logging tree
|
||
(below).
|
||
- `GET /fuse-identity` — serial, derived hostname and the SRK password, behind
|
||
the token AND the physical button; fetched on demand only.
|
||
|
||
**Panel conventions:** the header identifies the machine by its **fuse
|
||
identity** (the factory hostname derived from the OCOTP serial), regardless of
|
||
any cloud identity override. **Units** are a display-only preference
|
||
(`ui_units`): the backend stores metric, and saves post only fields whose
|
||
display string changed. **Position always shows** — counters-only and painted
|
||
red while unreferenced, normal once anchored.
|
||
|
||
**Camera engine.** One worker owns the V4L2 node persistently (media-ctl /
|
||
v4l2-ctl sequences identical to `gfhardware/cam.py`, factory exposure/gain/WB,
|
||
software hflip in the demosaic); it starts on demand and tears down fully after
|
||
10 s idle so gfhardware one-shot grabs still work. **Privacy gate: neither
|
||
camera captures unless the lid is closed** — `machine_lid_closed()` (EV_SW
|
||
bit 3, fail-closed) is checked at every entry point and once per frame, so an
|
||
open lid refuses stream and snapshot with HTTP 409 and a lid opened mid-capture
|
||
tears the pipeline down; `gfhardware.cam.capture()` enforces the same rule for
|
||
the cloud client's direct-V4L2 fallback and raises `LidOpen`. No setting
|
||
disables it, and the factory's lid-open focus hunt now fails as a result
|
||
(`docs/VIDEO.md` §2, `forgectrl/docs/SERVICES.md`). Geometry, Bayer depth and
|
||
the manual control set come from a **sensor profile** chosen by whichever
|
||
driver bound on that camera's I2C bus, so one image serves both the 5 MP
|
||
OV5648 (2592×1944) and the 8 MP OV8856 (3264×2448) — both 8-bit BGGR, so the
|
||
capture word and the demosaic are the same and only the geometry changes;
|
||
`/cam/status` reports the model and the frame sizes that follow from it.
|
||
A frame the capture queue flags errored is dropped rather than demosaiced,
|
||
four in a row cycle the queue, and three cycles with no usable frame stop the
|
||
engine; `/cam/status` carries the running `health` counts (`src/camhealth.c`,
|
||
host test `camhealth_test`). The cameras share the
|
||
hardware video-mux and the NEWEST request wins it: **streams preempt** (the
|
||
current stream's clients end cleanly), **snapshots borrow** (pause, switch,
|
||
grab one frame, switch back — a ~1–2 s freeze). The per-camera lamp
|
||
(`pic/lid_led` / `head/white_led`) is raised to `FORGECTRL_LAMP` (default 132)
|
||
while capturing and restored to the resting level on idle. The resting lid lamp
|
||
is the `lid_lamp_idle` setting (0–255, default 236), asserted at daemon start,
|
||
on a live settings change, and at every controller spawn.
|
||
|
||
Measured performance (bench): **15.0 fps sustained** at 1296×972, sensor-
|
||
limited — NEON superpixel→YUV420 convert (18–20 ms) plus CODA960 VPU JPEG
|
||
encode (7 ms) on cached (non-coherent) V4L2 capture buffers, so there is no
|
||
bounce copy; daemon ~41 % CPU with one viewer. Full-res snapshot 2.4 s warm /
|
||
2.7 s cold. Fallbacks, each bench-verified: `FORGECTRL_NO_CACHED_BUFS` (bounce
|
||
copy, needed on a kernel without the `allow_cache_hints` patch — detected via
|
||
the `MMAP_CACHE_HINTS` capability bit), `FORGECTRL_NO_NEON` (scalar convert,
|
||
bit-identical), `FORGECTRL_NO_VPU` (libjpeg; also the snapshot path).
|
||
The default path is newer and bench-proven: the GC880 GPU demosaic feeding the
|
||
`/cam/h264` CODA960 H.264 stream (render, IPU stride-fix crop, VPU encode;
|
||
~14 fps for one viewer at ~14 % CPU, luma bit-clean against the CPU path) with
|
||
CSI hardware frame skip as the low-CPU setting; `camera.h264-stream` covers
|
||
it in the acceptance catalog. `FORGECTRL_NO_GPU` / `FORGECTRL_NO_H264` /
|
||
`FORGECTRL_NO_HW_SKIP` strip them individually, each falling back to the
|
||
measured paths above.
|
||
`/cam/status` reports `encoder` and `buffers`. A CSI glitch frame can out-size
|
||
the coda driver's default JPEG capture buffer, so forgectrl requests 3 B/px and
|
||
drops error-flagged dequeues as single bad frames. **LightBurn consumes the
|
||
stream directly** while jogging from the same session; motion coexistence is
|
||
proven (`clamped 0`, max behind 4.5–7.2 ms of the 200 ms queue at 15 fps).
|
||
|
||
Run by hand: `/usr/bin/forgectrl &` after `/etc/init.d/forgectrl stop` (kill
|
||
before scp when redeploying — text-file-busy). It logs through syslog
|
||
(`/data/log/forgefirm/forgectrl/forgectrl.log`; a terminal, or `FFLOG_STDERR=1`,
|
||
echoes the lines).
|
||
|
||
**Wireless region.** `wifi_country` (System tab, full ISO 3166-1 alpha-2
|
||
dropdown, default 00 = world) is applied with `iw reg reload` + `iw reg set`
|
||
at daemon startup and on every change; the same pass pins `wlan0 power_save
|
||
off`. With the regulatory db loaded and no user hint, cfg80211 follows the AP's
|
||
802.11d country IE; a user-set region overrides it. The startup pass hints a
|
||
region only when one is set (hinting `00` into the default world domain makes
|
||
cfg80211 report the confusing `country 98` alias).
|
||
|
||
## Diagnostics (forgectrl-owned hardware tests)
|
||
|
||
The Diagnostics tab runs tools that **take the hardware over**: the runner
|
||
(`diag.c`, one slot) suspends the active controller through the supervisor
|
||
(launch is gated on cnc idle + no diagnostic), drives the loop directly through
|
||
sysfs, and resumes the controller on every exit path (completion, tool error,
|
||
operator abort via `POST /diag/abort`, safety ceiling). The cooling engine
|
||
suspends its own writes for the duration and publishes fire-blocked.
|
||
`/run/forgefirm-diag.active` marks the ownership, and forgectrl startup recovers
|
||
a stale marker. The laser is untouched throughout (latch stays locked). While a
|
||
diagnostic runs, settings POSTs 409, `/status` reports `diag:true`, and the
|
||
panel locks with a banner. Live progress streams through `GET /diag/status`.
|
||
|
||
Both cooling tools run at the *configured* duty/window/threshold, with
|
||
cut-profile chassis fans (the characterization condition); pump-off windows
|
||
hard-abort at 48 °C downstream:
|
||
|
||
- **flow-verify** (~3 min): one check with the pump on, one with it commanded
|
||
off, judged against `cool_flow_rise`. PASS = the threshold separates the
|
||
readings; margins under 1.5 °C add a run-calibration warning.
|
||
- **flow-calibrate** (~15–25 min): 3 trials per case, alternating, with settle
|
||
gates between; reports both bands and recommends threshold = (flow max +
|
||
no-flow min)/2 with an Apply button, or refuses when the gap is under 3 °C.
|
||
|
||
**Cooling tunables are conf-backed**: the nine `cool_*` keys (`flow_rise`,
|
||
`flow_heater_pct`, `flow_check_s`, `recheck_s`, `confirm_max_s`, `temp_max`,
|
||
`temp_resume`, `cooldown_s`, `cooldown_max_s`) live in `/data/forgefirm.conf`
|
||
(Machine tab, validated ranges), and the cooling engine re-reads them at **every
|
||
run start** (env `GFCOOL_*` > conf > compiled default; env stays the bench
|
||
override and wins for the process lifetime).
|
||
|
||
**Flow verification, as it runs:** a one-shot check at flood start (M8) heats
|
||
the loop at `cool_flow_heater_pct` for `cool_flow_check_s` and discriminates on
|
||
downstream temperature RISE, with periodic re-checks every `cool_recheck_s` —
|
||
a stopped pump is undetectable any other way. A check starts only once the
|
||
sensors agree and the downstream reading is stationary (split-half mean
|
||
difference, not peak-to-peak). An over-limit check is a **suspicion**, not a
|
||
fault: the next completed check decides it (over-limit again → FAULT, clean →
|
||
cleared, three cleared episodes in one job → aggregated warning), and a
|
||
suspicion that produces no verdict within `cool_confirm_max_s` escalates to
|
||
FAULT. Over-temp policy is the factory's: a CYCLE over `cool_temp_max` gets a
|
||
feed hold plus forced cooling airflow and auto-resumes under `cool_temp_resume`;
|
||
a JOG gets a jog-cancel.
|
||
|
||
## Logging
|
||
|
||
rsyslog is the system logger and the only log writer. forgectrl and the grblHAL
|
||
driver emit through the shared non-blocking `fflog` emitter (drops, never waits
|
||
— a stalled log daemon can never park a controller thread), gfcloud/gfhome
|
||
through `SysLogHandler`, the kernel through `imklog`; a controller's stray
|
||
stdout/stderr rides a per-controller `logger` relay under its own name. Tree:
|
||
`/data/log/forgefirm/{forgectrl,grblhal,gfcloud,gfhome,kernel,system}/`,
|
||
size-capped and rotated at boot and hourly (the `forgefirm-logging` recipe
|
||
renders the rsyslog rules from the settings at S19 via
|
||
`forgectrl --render-syslog`). Levels (`log_<logger>_disk` /
|
||
`_remote`) and the remote target (`syslog_server/port/proto`) are machine
|
||
settings **applied at reboot** — the panel's Logs tab shows configured vs.
|
||
effective and offers the reboot, plus a live viewer and a sanitized `tar.gz`
|
||
export for issue reports (`POST /logs/export`; `src/sanitize.c` replaces
|
||
serial, hostname, cloud credentials, panel token, SSID/PSK, IPs, MACs and
|
||
e-mails with stable placeholders). Design and contract: `SERVICES.md`
|
||
"Logging".
|
||
|
||
## Release acceptance (forgetest, port 8090)
|
||
|
||
The release acceptance tool — catalog, campaigns, domain fingerprints,
|
||
inheritance, the always-required core, invalidate-all, the release gate and the
|
||
coverage currency rule — is specified on the site (Developers, "Acceptance"); the tool lives in
|
||
`forgetest/` and ships only on the dev image (`/etc/init.d/forgetest`, HTTP
|
||
:8090). It is **bench-validated**: the full campaign on dev image
|
||
`20260824230512` (`c-20260824231028-b7ca`) satisfied 45 of 45 from nothing,
|
||
36 of them unattended with the bench actuator in the loop, in 27 minutes, and
|
||
the export reads "Release authorized: YES" for that image's manifest. That
|
||
authorizes a release; it is not one until `releases/v<version>/acceptance.json`
|
||
is committed.
|
||
|
||
- **Catalog: 46 tests** in `forgetest/forgetest/suite/`, every one a port of a
|
||
proven bench drill or a bench-verified check: the always-required core
|
||
(`image.health`, `kernel.latch-locked-idle`, `kernel.k1-k2`,
|
||
`kernel.fire-line`), `forgectrl.*`, `logs.*`, `update.*`, `motion.*`
|
||
(pacing, jog round-trip, liveness probe, cancel/abort, dead-man, the lid,
|
||
interlock and button parity tests), `cooling.*` (flow verification, fans
|
||
quiet after motion, a gate setting tripping and off by value, a fan under
|
||
its floor), `camera.*`,
|
||
`laser.*` (emission witness, arm-wait lid, disarm-in-hold, armed kill,
|
||
pause/resume/lid-cancel, the rapids after an M5 shipping dark) and `cloud.*` (the service protocol answered by
|
||
the emulator in this machine's identity, with only the app to drive; the
|
||
mode round trip with the lid-open hunt and the web-service homing on it;
|
||
one real print; and the job-behavior tests under the offline service:
|
||
the cloud client driven from a local socket with a synthesized
|
||
laser-free job, no account, no network, nothing on the bed). Tests that
|
||
share a setup are merged; the `auto` tests stay separate for failure
|
||
isolation. 28 are `auto`, 9 `operator`, 9 `live`; with the bench actuator up,
|
||
eight of the operator tests run in the unattended queue.
|
||
- **The operator's part is asked for by name, not by popup**
|
||
(the site, Developers, "Acceptance", "The operator's part"): a Ready prompt before a
|
||
timed step, a standing notice the test takes down when the machine shows
|
||
the action done (`ctx.act("lid", "open")` and its kin, the seam a bench
|
||
actuator will plug into), and one confirm by eye left in the catalog (the
|
||
emission witness's mark). The head accelerometer, the beam detector, the
|
||
button LEDs, and a lid-lamp toggle between two snapshots replaced the
|
||
other eyeball confirmations; `kernel.fire-line` and `camera.snapshot` are
|
||
`auto`. With the bench actuator up the attended block is the ten tests
|
||
that need a person (five laser live, five cloud): 12 minutes on dev image
|
||
`20260824230512`. A test's implementation hash is its own function plus its
|
||
module's shared code, so a fix inside one test re-requires that test
|
||
alone.
|
||
- **Machine identity is content-defined.** Every component recipe contributes
|
||
`forgefirm-manifest.bbclass` entries (the kernel and the module through
|
||
`do_deploy`), `forgefirm-image-manifest.bbclass` assembles them plus the layer
|
||
content hashes into `/etc/forgefirm-manifest.json` (also deployed beside the
|
||
image as `*.forgefirm-manifest.json`), and `scripts/manifest-from-tree.py`
|
||
computes the byte-identical thing on a workstation — the identity is
|
||
content-defined, independent of the checkout's commit or dirty state.
|
||
**Component pins live in `<recipe>-pin.inc`** (SRCREV + the PV that moves
|
||
with it, nothing else) and
|
||
are left out of the layer content hash, so a pin bump invalidates only the
|
||
tests covering that component; a pin written into a recipe body counts as a
|
||
platform change and invalidates everything.
|
||
- **Baseline rule:** every test and bench tool is bracketed by a baseline pass
|
||
(`forgetest/baseline.py`), against a fresh-boot reference taken once per boot
|
||
**after a power cycle** (a soft reboot leaves the lid lamp dark — the PIC
|
||
lights it at power-on). Takeover runs capture the controller-owned kernel
|
||
attributes on entry and write them back before forgectrl restarts, so a
|
||
leftover `motor_lock` mask can never read as a wedged driver.
|
||
- **Coverage currency is enforced in CI** (`python3 -m forgetest.coverage
|
||
--enforce` in `forgetest-ci.yml`, over the tree manifest): an uncovered
|
||
manifest path fails the build, because it would let an inherited PASS survive
|
||
a change that should have invalidated it.
|
||
- **Bench tab:** every board-runnable tool in `scripts/bench` is runnable from
|
||
the page (scope tools, the flow characterization family, the escalation
|
||
drill, the live drills, `resume_dark_lead.py`), with takeover tools bracketed
|
||
by a forgectrl stop/start. `scripts/bench/gfbench.py` resolves `GF_HOST`
|
||
(host mode, ssh) or the board itself (local mode). Not ported by nature: the
|
||
two null-sink CI harnesses and the `.puls` decoder.
|
||
- Releases are signed only when `releases/v<version>/acceptance.json`
|
||
authorizes the built rootfs (`scripts/release.sh`).
|
||
|
||
## Hardware facts bank (measured)
|
||
|
||
- **The bench actuator's wiring** (`fixture/README.md` for the box itself).
|
||
Three 3.3 V optocoupler relay modules, high-level trigger, coils from the
|
||
machine's 3.3 V (about 100 mA each), inputs from the ESP32-S3 DevKitC-1's
|
||
GPIO 4 (lid), 5 (interlock), 6 (button), the button's enable jumper on
|
||
GPIO 7 to GND. The lid contact (NC) goes in series with the lid-switch
|
||
loop at J4.12/13; the button contact (NO) across the front button input
|
||
at J5 (BTN and its 12 V); the interlock contact (NC) in the remote
|
||
interlock loop at J8 (SAFETY.md; J6 is the speaker). The machine's 3.3 V
|
||
rail carries the three coils with room to spare. The DevKit and the
|
||
machine share a ground through the modules, so the DevKit is powered from
|
||
a USB wall adapter. The interposer harness itself is bench-local and is
|
||
not described in any repository.
|
||
|
||
- **The factory's envelope, decoded** (firmware 2.6.0-2228, the 23 captured
|
||
headers, this board's own factory logs). The pulse header is the job's
|
||
operating envelope and the factory refuses to cut without it: 29 tags are
|
||
mandatory, 346 are header-legal, an unknown tag is logged and skipped. The
|
||
service fills the fan duties, the coolant window, the per-sensor temperature
|
||
ceilings, the lid IR thresholds, the accelerometer thresholds and an HV
|
||
current cap per job; a cut job carries the real fan duties (air assist
|
||
1023, exhaust 65535, intake 43278, equal to ForgeFIRM's run profile) and a
|
||
hunt or motion file carries air assist 204 with the extraction fans off.
|
||
Every tach window is zero in every capture except `AArx` 64500 on cuts, and
|
||
the factory's intake and exhaust tach monitors treat zero as not configured,
|
||
so a stalled extraction fan is caught there by the temperature it causes;
|
||
when a fan alert does fire during a cut the factory pauses the print on the
|
||
same transition as a user pause. Temperature runs two tiers there: a plain
|
||
alert pauses, a `*_temp_critical` fails the machine; the units are per
|
||
sensor (the coolant family is carried twice, raw counts with the NTC's hot
|
||
end as "min", and millidegrees), and a stock machine's live coolant window
|
||
is 10 to 30 C idle and 5 to 35 C warm-up and run, `CMrx` 33000 on a cut
|
||
being exactly the shipped 33 C ceiling. The factory does not verify coolant
|
||
flow: the calorimetric `CF` controller in its firmware is never armed and
|
||
its heater is written only at phase changes. ForgeFIRM's answer, all of it
|
||
landed and bench-proven in the catalog (`cooling.gate-off`,
|
||
`cooling.fan-gate-trips`, `cooling.critical-tier`, the hunt leg of
|
||
`cloud.mode-switch`) and in the CAMPAIGN-LOG drills: every gate a plain
|
||
setting with an off end; a header value only ever tightening a local one;
|
||
every fan held to a measured floor with a fault, not a pause, for the
|
||
session; a coolant critical line above the ceiling's pause; the board
|
||
temperatures watched per job; and the rest of the envelope declared, tag by
|
||
tag, in `CLOUD.md` "The pulse header".
|
||
- **Board temperatures at idle** (room ~22 C, machine on for hours): the
|
||
chassis LM75 reads **29.0 C**, `pic/pwr_temp` reads **589 raw** (the
|
||
unverified guess `raw * 0.08715 - 21` would make that 30.3 C), the SoC die
|
||
**42.8 C**. Ranged per job by the engine from here on. The supply stays a
|
||
raw count by decision: its heatsink cannot be reached with a thermometer
|
||
while the machine runs, so the conversion is not going to be verified on
|
||
this bench, and a number nobody has checked is not published as degrees.
|
||
The per-job range in raw counts is the record, and a ceiling, if one is
|
||
ever wanted, is set in raw counts from it (`temp_calibrate.py supply-*`
|
||
stays for a machine where the heatsink is reachable).
|
||
- **The SoC guards itself.** The i.MX6DL (rev 1.3) on-die monitor is
|
||
`thermal_zone0` (`imx_thermal_zone`, the same node as `hwmon0`), governor
|
||
`step_wise`, trips at **85 C passive** and **90 C critical** (the
|
||
consumer-grade points the driver derives from the fuses: hot point 95,
|
||
critical at hot minus 5, passive at hot minus 10). The passive trip is
|
||
bound to `cpufreq-cpu0` (996 / 792 / 396 MHz OPPs; `performance` is the only
|
||
governor built, so the core sits at 996 MHz until the trip lowers it) and
|
||
both GPU cooling devices; the critical trip is the kernel's orderly
|
||
poweroff. A throttle slows the engine, the camera and the protocol thread
|
||
before the step stream (the ring is in hand). The factory board carries
|
||
**no heatsink or fan on the SoC**, only the mounting holes for one, and
|
||
needs none: under a full core for five minutes on top of the live camera
|
||
stream, in a 30 C chassis, the bare die plateaus at **70.8 C**, 14 C under
|
||
the passive trip, with the core at 996 MHz and no cooling device off
|
||
state 0. The die-to-chassis delta at full load is about 41 C, so the
|
||
passive trip is a hot-chassis case (above roughly 44 C), not a load case.
|
||
The per-job SoC range and the throttle log line are the running record.
|
||
- **Fan speeds at the cut profile** (exhaust duty 65535, intake 43278, air
|
||
assist 1023; sampled at 1 Hz over 120 s from idle, the exhaust duct's
|
||
inline booster fan off): exhaust **11640 rpm** steady (spread 11444 to
|
||
11947, 90 percent of steady in 5 s), intakes **4157 / 4158 rpm** (spread
|
||
under 100, 7 s), air assist **11050 rpm** (spread 30, 1 s); at idle the
|
||
exhaust and intakes read 0 / ~745 rpm and the air assist ~1900 rpm
|
||
(idle duty 204). The purge-air fan is always on and reads **~625 counts**
|
||
of `head/purge_air_current` (~1 when off). The airflow floors are 55
|
||
percent of these (bands 50 to 60 percent); an inline booster fan changes
|
||
the exhaust's back pressure and can move its reading by a few percent
|
||
either way, well inside the margin.
|
||
|
||
- **DRV8825 stepper drivers wedge on 40 V rail glitches** (factory board; the
|
||
TMC2130s belong to the upgraded OpenGlow board only). A glitch can leave the
|
||
drivers unserviceable: SDMA playback and the position counters run normally
|
||
while the motors produce nothing. The supply itself is fine — this is a
|
||
driver failure mode, not a marginal rail. Their reset lines are strapped (no
|
||
kernel pin), `cnc/faults` does not flag the state, and whether a given rail
|
||
power-up wedges them is chance. Recovery: a longer true power-off (the
|
||
forgectrl supervisor ladders 5/15/30 s) and, at worst, a full machine power
|
||
cycle. Consequences: **counters, anchors and `H:1` are never proof of
|
||
motion**; keep the rail up (every power-up is a wedge lottery), which is why
|
||
the pulse-device broker exists and why there is no idle-rail-off policy.
|
||
- **Motion liveness = the head accelerometer** (`glowforge.dts` `head-accel`,
|
||
i2c-3 @0x1e — resolve iio devices by bus path, never by index; lid = i2c-0
|
||
@0x1e, board = i2c-3 @0x1d). Signatures on an identical commanded move: real
|
||
motion **1800–2900 counts peak-to-peak** on X/Y (noise floor at 1 g ≈ 16384),
|
||
a genuinely dead/wedged axis ≤ ~250, and the rail-on / current-step jolt up to
|
||
~700 — which is why the forgectrl probe gates controller start at
|
||
**p2p ≥ 800** (`P2P_MOVING`), writes `cnc/motor_lock=0` for its own move (a
|
||
leftover mask from any tool must not read as a wedge) and settles 300 ms
|
||
after the run-current step before sampling. A masked axis reads 144–480.
|
||
gfhome requires at least one accel-witnessed motion window before a quiet
|
||
service counts as homed. Raw sysfs accel reads are slow (~150 ms each) —
|
||
enough for a binary verdict over a multi-second window, not for waveforms.
|
||
- **Any probe/liveness move goes RIGHT (+X) first, then back**: a cable lives
|
||
at the end of LEFT travel and must never be crushed.
|
||
- **Rail-contact signature** (from the retired accelerometer-homing spike,
|
||
relevant to any future contact sensing; tools `accel_fast.py`,
|
||
`bump_seek.py`): creep baseline ≈0.5–2 k counts, contact jumps to 29–42 k
|
||
within ~4 ms (20–40×). But **slow approaches are near-silent** — belt
|
||
compliance turns slow-speed skipping into sub-threshold grinding — so any
|
||
contact-sensing scheme must strike fast. Direct I²C (unbind st-accel,
|
||
CTRL1=0x6F = 800 Hz ODR) reads ~530 Hz from Python; st_accel sysfs one-shots
|
||
are ~6 Hz and the kernel has no IIO triggers.
|
||
- **WL1805 Wi-Fi rides uSDHC1** (mmc0, 4-bit, SD-high-speed at 49.5 MHz,
|
||
`no-1-8-v`; IRQ GPIO6_04, WLAN_EN GPIO5_26). Factory pad control, now ours
|
||
too: CMD/DATA `0x17069`, CLK `0x10069` (SPEED_MED, DSE 48 Ω, fast slew, HYS;
|
||
47 kΩ pull-up on CMD/DATA only). eMMC (uSDHC3) and the SD slot (uSDHC2) use
|
||
`0x17059`/`0x10059` (80 Ω), SD2_DAT3 `0x13059`. An SDIO CRC error surfaces as
|
||
`sdio write failed (-84)` and costs ~1 s of Wi-Fi (wlcore firmware recovery)
|
||
— see "Wi-Fi SDIO CRC watch" under Next work.
|
||
- **SDMA pulse engine**: ring size = the `ring_mb` module parameter (default
|
||
32 MiB, the factory ring size; power of two, must fit the 32 MiB
|
||
`cnc-pulsebuf` no-map DT pool). Free = size − 32 KiB gap, so 33,521,664 bytes.
|
||
Bench-verified on the 16 MiB ring the earlier images shipped, and the
|
||
mechanism is size-independent: 20 MB streamed at 100 kHz through the wrapping
|
||
ring, 0 ENOMEM, 0.4 ms max write latency, starve → `underrun` per protocol.
|
||
The ring holds ~1 MiB per 100 s of 10 kHz stream, so ~56 min of a cloud
|
||
print at a time; a longer job is fed live as it plays, and the grblHAL feed
|
||
keeps only a few KB in flight. The 32 KiB gap is retained history: the
|
||
writer stops that far short of the play head, so any fill leaves 3.2 s of
|
||
played program (at the print tick) to back a pause into, which is what
|
||
`cnc/max_backtrack` reports less the deceleration tail. The engine's `ipg`
|
||
and `ahb` clocks are enabled only by a channel holder: imx-sdma leaves them
|
||
off after probe, and glowforge.ko holds them itself through
|
||
`sdma_get_channel()` in the SDMA API patch for as long as it is loaded;
|
||
nothing else on this board holds an SDMA channel (ecspi2 runs PIO). With the
|
||
block gated every channel-0 transfer completes at once and moves nothing:
|
||
the ring reads back its bounce page, the probe cannot start and `cnc/free`
|
||
exceeds the ring, which is why `image.health` asserts the clock enable
|
||
count directly.
|
||
- **Reserved memory**: 511 MiB usable DRAM (`0x10000000`–`0x2fefffff`), of which
|
||
96 MiB is reserved for DMA: the 32 MiB `cnc-pulsebuf` no-map pool (dynamically
|
||
placed, `alignment = size`, so it lands at `0x2c000000`) plus 64 MiB of
|
||
reusable CMA for camera/IPU/VPU buffers. no-map means the pulse pool is gone
|
||
from the kernel's map whether a job uses it or not, which is what makes
|
||
`dma_alloc_coherent()` deterministic for a late-probing out-of-tree module.
|
||
The 1 MiB above the memory node (`0x2ff00000`, held back by the bootloader)
|
||
is pstore/ramoops: 32 KiB dump records, a 256 KiB console record, 16-byte
|
||
ECC, mounted at `/sys/fs/pstore` from fstab and staged by the log export.
|
||
MemTotal ~464 MiB on the board-only kernel (`linux-fslc` 6.12, `SMP` off,
|
||
`CONFIG_PREEMPT=y`, zImage 4.8 MB, 31 module packages, ROM SDMA scripts);
|
||
measured idle use in GRBL mode with the daemon and
|
||
controller up is ~100 MiB. The playback script is
|
||
relocated to SDMA channel 26 at `<26 0xF00>` (halfword 7680) with a pre-run
|
||
integrity guard; the probe lines to look for are `EPIT clock 66000000 Hz` and
|
||
`SDMA channel 26 reserved for pulse playback (script at halfword 7680)`.
|
||
Measured script ceiling **~165 kHz effective** (~6 µs/byte); position
|
||
counters (`sdma_context`
|
||
sc0/1/2 = X/Y/Z steps, sc3 = bytes) match grblHAL exactly. Underrun proof:
|
||
100 kHz × 120 s under full load, 150 ms queue, 0.2 ms worst write latency,
|
||
zero underruns. Real time: the kernel runs `CONFIG_PREEMPT=y` (the factory
|
||
behavior; `imx_v6_v7_defconfig` alone gives `PREEMPT_VOLUNTARY`).
|
||
PREEMPT_RT is not selectable on arm32 6.12 (no `ARCH_SUPPORTS_RT`) and is
|
||
not needed: the ring drains at 1 byte per EPIT tick, at most 200 KB/s even at
|
||
the 200 kHz ceiling, so the feeder's bounded queue depth of ~150 ms (a few
|
||
KB in flight) rides out worst-case scheduling latency with orders of
|
||
magnitude to spare. Bounded queue depth plus `SCHED_FIFO` for the feeder is
|
||
the design; RT is worth revisiting only if the underrun bench ever
|
||
contradicts this arithmetic.
|
||
- Byte layout and stream rules: see the UAPI.md feeder contract
|
||
(authoritative).
|
||
- **Z**: bit 6 SET = lens UP = +Z (hardware-verified). Home = hall trigger at
|
||
TOP; usable travel ≈ 30 half-steps ≈ 10.6 mm ≈ 0.417"; 0.3534 mm/half-step.
|
||
Never blind-drive Z — hall-supervised only.
|
||
- **XY**: 0.15 mm per full step; DIR bit set = −X / +Y (Y1/Y2 complementary).
|
||
**+Y physically moves the gantry toward the FRONT.** Home corner (convention,
|
||
for the planned limit-switch homing) = back-left (X min, Y min), workspace
|
||
all-positive from that corner.
|
||
- **Factory motion profile** (measured from captured factory pulse streams
|
||
with `puls_profile.py`): accel ≈ 700 mm/s² X / 590 mm/s² Y on v2.6.0 firmware
|
||
(2018 firmware used ≈1000); header HAxr=132/HAyr=112/HAar=133 ⇒ ≈5.3 mm/s²
|
||
per HA unit. Travel moves peak 202 mm/s vector (≈ 8 in/s) at STfr=28160 Hz;
|
||
prints and hunts run STfr=10000. Cut feed in the sample print: 145 mm/s. Z
|
||
cadence ≈ 61–115 ms per half-step (≈ 5.7 mm/s max).
|
||
- **Factory analog config** (constant across all captured jobs, 2018→2026):
|
||
PIC currents X 135 run / 33 hold, Y 22 run / 5 hold (axis DAC scales differ by
|
||
design); x/y_decay=1; ×8 microstepping; run currents applied only while
|
||
motion plays, hold otherwise.
|
||
- **Laser PWM**: 39.98 kHz register-verified (divider 13 × 127 counts), scope-
|
||
confirmed at 25.0 µs period across the full duty range, clean at the low end
|
||
(6.4 % measured vs 6.3 % commanded at PWMSAR=8).
|
||
- **Laser duty thresholds** (ladder on scrap at F300, constant power): the
|
||
tube has two thresholds, far apart. The discharge **strikes between 2 % and
|
||
3 %** duty — 2 % (PWMSAR 2) draws no measurable `hv_current` and leaves
|
||
nothing at all, 3 % (PWMSAR 3) draws current — but it does **not lase
|
||
usefully until 16 %** (PWMSAR 20), the lowest duty leaving a continuous
|
||
mark. Between them (3–14 %) is a **dead band**: current flows and climbs,
|
||
and each line shows only a spot at its start (the strike transient) with a
|
||
dark line after it. So the usable analog range is ~16–100 %, and `$35`
|
||
(`DEFAULT_SPINDLE_PWM_MIN_VALUE`) ships at **16** to hold every nonzero S
|
||
above it. Raw `hv_current` counts are a presence/absence witness only: the
|
||
per-rung means are non-monotonic at the top of the ladder and the signal
|
||
has no characterized transfer function.
|
||
- **Factory power model** (three cloud cuts of one 1" square, same location,
|
||
material and speed, only the UI power setting changed, pulse files captured
|
||
from each): the **power byte is pinned at 127**
|
||
in all three runs — three occurrences each, one as the cut begins and a
|
||
refresh every ~27 000 ticks (~2.7 s). Analog duty is never a power control.
|
||
**Dose is FIRE-bit density on a fixed 7-tick period** (700 µs at
|
||
`STfr` = 10 000, ~1.43 kHz), the on-count dithered between adjacent integers
|
||
to reach a fractional duty: Precision Power 1 = 1.371 of 7 (density 0.1953,
|
||
runs of 1 and 2), PP 100 = 5.576 of 7 (0.7952, runs of 5 and 6), Full Power
|
||
= 7 of 7 (0.9965, continuous). The period was exactly 7 in all 570 measured
|
||
cycles of both dithered runs, and the mix of adjacent on-counts matches the
|
||
fractional part exactly (PP 1 wants 1.371; 2-runs are 212 of 571 = 0.371).
|
||
The three **headers are identical** — the power setting never reaches the
|
||
machine, so the whole model is service-side. Motion is identical too: 5420
|
||
steps, 101.62 mm, 10.81 s at 9.44 mm/s. **Density tracks velocity through
|
||
corners**, by the same relative factor at every power setting (corner/cruise
|
||
0.38, 0.38, 0.41), but only partly: fire ticks per step rise 3.89 → 7.00 as
|
||
speed falls 9.44 → 1.22 mm/s, so dose per unit length rises ~1.8× at a
|
||
corner instead of the ~7.7× it would rise with no compensation. On the UI
|
||
scale, PP 1→100 is linear in density (~0.006 per unit, intercept ~0.189) and
|
||
Full Power sits off that line, where PP ~134 would land.
|
||
- **Density dose limits** (measured on five ladders, `dladder`): under the
|
||
FIRE-density model the interval between pulses at a level below the
|
||
minimum is `min_ticks x tick / density` - **the base period cancels**,
|
||
which is why periods 10, 20 and 40 gave identical results. The tube
|
||
**strikes down to ~5 % density at a 2.26 ms interval** (`min_ticks` 3,
|
||
106 us pulses) and **fails to strike at 4.51 ms** (`min_ticks` 6, 213 us):
|
||
lengthening the pulse at fixed density lengthens the gap in proportion,
|
||
and the gap is what kills re-striking. It **marks from ~10 %** at F300 on
|
||
scrap. `min_ticks` 3 is essentially the factory's own structure - its
|
||
6.5 % engrave jobs put 100 us pulses 1.54 ms apart, against 1.64 ms for
|
||
`min_ticks` 3 at that density - and 6 is outside anything the factory
|
||
does. Below ~5 % no pulse shape reaches the tube: the interval grows as
|
||
1/density, so 1 % implies an 11 ms gap, five times what already failed.
|
||
**The scale closes that gap instead:** `$35` = 10 maps S onto 9.4-100 %
|
||
density, putting a commanded 1 % at 10.2 %, and a ladder weighted to the
|
||
bottom (1, 2, 5, 10, 20, 40, 70, 100 % of S) then marked on **all eight
|
||
rungs**, with eight current segments and means rising 136 -> 968. So a
|
||
user's 1 % is a real, visible mark rather than silence.
|
||
- **Cooling operating point**: 40 % heater duty, 50 s window, flow-rise
|
||
threshold 14.4 °C, re-checks every 150 s. Below ~40 % duty the stagnant loop
|
||
sheds the heater's output by convection well enough to mimic flow (at 30 %,
|
||
three of five dead-pump trials looked healthier than a working pump). Record
|
||
at 40 %: 25/25 correct classifications, plus all three settle cases. Settled-
|
||
loop noise is 0.52 °C peak-to-peak but only 0.11 °C split-half, which is why
|
||
the stationarity gate uses split-half means. Coolant windows: run ceiling
|
||
33 °C, resume 31 °C (factory job-header CMrx/…); the factory's low side
|
||
(floors ≈1.0/4.0 °C, ~16 °C warm-up gate) is not implemented yet. The
|
||
coolant thermistor conversion is the factory B-equation recovered from the
|
||
v2.6.0 binary — derivation in `kernel-module-glowforge/UAPI.md`; the old
|
||
UAPI "best guess" linear formula was 3–5 °C high and everything derived from
|
||
it had to be re-derived.
|
||
- **The four `pic/lid_ir_*` channels are first of all a photometer for the lid
|
||
lamp.** Measured against `lid_led`: 0 → `2 2 1 2`, 8 → `2 2 3 2`, 131 →
|
||
`54 55 61 62`, 255 → `172 171 190 188`. Against that lamp-set level, a
|
||
full-power cut raises them only +4 to +6 counts and a candle burning on the
|
||
bed +3 to +6, with ±3 counts of ambient noise and ~+22 counts of day-to-day
|
||
drift. forgectrl's camera engine drives `pic/lid_led` for every lid capture,
|
||
and the resting level varies (131, 8 after a reboot, cloud mode sets its own),
|
||
so a fixed-count gate fires a phantom FIRE stop on any lamp change.
|
||
`cool_fire_ir_delta` therefore ships **0 = watch-only**; each job still logs
|
||
baseline and peaks.
|
||
- **Emission and HV witnesses**: `cnc/laser_on_sampled` goes to its full 255
|
||
count on a commanded fire window and returns to 0 at Idle — the reliable
|
||
witness. `pic/hv_current` tracks the cut (0 idle → hundreds/1023 raw while
|
||
firing) and is the only live HV telemetry on this PSU (`hv_voltage` is
|
||
grounded). `cnc/laser_pgood_sampled` stays 0 through real cutting: not usable
|
||
here.
|
||
- **Switches**: truthy = closed/OK for lid/doors/button. **SW_INTERLOCK is
|
||
INVERTED**: the remote interlock (the regulatory 2-pin lockout connector)
|
||
reads ACTIVE only when the loop is OPEN. Basic/Plus — including the bench
|
||
machine — ship the connector factory-jumpered, so the bit reads 0 =
|
||
satisfied; Pro brings it out for an external lockout chain. It must NOT gate
|
||
motion (the beam is hardware-gated), but ForgeFIRM's kernel module does drive
|
||
INTERLOCK_RESET high whenever the loop reads open, so the CD4043B latch
|
||
blocks the LASER_ON gate in hardware until the loop is closed again
|
||
(bench-verified: loop pulled → `interlock_latch`=1, `interlock_circuit` b4
|
||
set, all within one 50 ms sample; reinserted → all clear).
|
||
- **`hv_enable` (EV_SW bit 4, GPIO4_06) is the readback of the safety chain's
|
||
HV_ENABLE output** through the U24 inverter — not an input. Active for the
|
||
whole duration of any run, inactive at idle, and it drops 454 ± 3 ms after
|
||
the last charge-pump pulse (one-shot t_w measured pulse-to-drop with
|
||
`scripts/bench/cp_watchdog_timing.py`: 451.8 / 455.6 ms; feed period
|
||
199.98 ms; matching the measured R·C ≈ 500 kΩ × ≈900 nF). It gates nothing —
|
||
it is telemetry (`/status` `switches.hv_enable`, panel "HV enable"), read
|
||
alongside `cnc/charge_pump_alive` (`interlock_circuit` b5). **Across a pause
|
||
and a resume** (measured at the pads with `scripts/bench/resume_dark_lead.py`,
|
||
~2 kHz through /dev/mem): a pause stops motion 317 ms after the command and
|
||
HV_ENABLE drops with the watchdog 550 ms after it, so a pause shorter than
|
||
about half a second never drops HV at all; on the resume HV_ENABLE and the
|
||
watchdog are back within ~3 ms while motion only restarts at ~219 ms — the
|
||
chain re-arms ~216 ms **before** the first step, so a resumed cut loses
|
||
nothing and no dark dwell is warranted. Naming note: the factory design
|
||
labels this net **E-STOP**; entries in `CAMPAIGN-LOG.md` written before the
|
||
2026-08-15 rename call it `estop`/`SW_ESTOP` with the pre-rename polarity
|
||
(the DTS then declared the pin active-high, so the bit read HIGH at idle and
|
||
LOW through a run — the same physical behavior, inverted). The DTS now
|
||
declares it active-low, and the former `estop_halts_motion` /
|
||
`MOTION.ESTOP_HALTS_MOTION` opt-in is gone: a real e-stop belongs in the
|
||
lid-switch chain (`docs/SAFETY.md`). Doors/door1/door2 stay stable during
|
||
motion.
|
||
- **Factory job behavior on the lid and the button, measured on 2.6.0-2228**
|
||
(bench session 2026-08-16; this is what ForgeFIRM's parity policy
|
||
reproduces). Lid open mid-print: `cnc/stop` 5–6 ms after the edge, decel to
|
||
idle in 86–91 ms, the return-home park starting ~300–340 ms after the edge and
|
||
running to completion **with the lid still open**, the job reported
|
||
`:cancelled`. A cancel from the app takes the same path. The button pauses a
|
||
print — controlled stop, then a 2000-tick laser-off backtrack — and resumes it
|
||
with a 1950-tick laser-off lead; the button **flashes white while paused**. A
|
||
lid open while paused cancels the job and parks from where it stands. The lens
|
||
hunt is not lid-gated.
|
||
- **The hardware button latch is what makes the armed window honest.** A lid
|
||
open SETs it (set-dominant), and it stays SET until the lid is closed, the SoC
|
||
lock is released **and the button is pressed** (`docs/SAFETY.md`). So a policy
|
||
that cancels the job on a lid open and re-arms only through a fresh button
|
||
press keeps software and hardware in agreement by construction; one that
|
||
resumes a job after a lid open leaves the beam blocked in hardware while
|
||
software believes it is armed.
|
||
- **`interlock_circuit` bitmask**: b0 = SoC-side LASER_ON monitor, active LOW
|
||
(1 = not lasing); b1 = FIRE, active high; b2 = button latch; b3 = latch,
|
||
1 = locked; b4 = interlock latch reset; b5 = charge-pump watchdog readback.
|
||
b0/b1/b3 were pinned by scope experiment, b2/b4 come from the factory decode.
|
||
`cnc/laser_latch` is write-only, so lock state is read from b3.
|
||
- **Machine identity from OCOTP nvmem**: HW_OCOTP_MAC0 is the serial,
|
||
base-23-encoded to the factory hostname (`BCDFGHJKMQRTVWXY2346789`, XXX-YYY)
|
||
— fuse-verified against the factory label, and the C implementation matches
|
||
gfhardware `id.py` over 200 k random serials. The bench machine's actual
|
||
values are deliberately not recorded here: this is a public document and a
|
||
fuse identity cannot be rotated.
|
||
|
||
### eMMC boot & recovery architecture
|
||
|
||
- eMMC (`mmcblk2`): 3.6 GiB user area + two 16 MiB hardware boot partitions
|
||
(`mmcblk2boot0/1`). Factory user-area MBR (per the factory `.fw` manifest):
|
||
p1/p2 = 200 MiB rootfs A/B at blocks 8192/417792, p3 = `/data` from block
|
||
827392 to end of disk. (The bench board ran the legacy ForgeFIRM layout —
|
||
p3 shrunk plus a p4 — until `slotmigrate` reclaimed it to the byte-exact
|
||
factory geometry.)
|
||
- **U-Boot lives in boot0** at 1 KiB (IMX IVT header), not in the user area.
|
||
Any boot0 rewrite below 0xC0000 risks the bootloader.
|
||
- **Saved env**: user area 0x80000 with a redundant copy at 0x82000 (what
|
||
`ffboot`/`fw_setenv` target; boot0's own 0x80000 region is zeros). Slot
|
||
selection = `mmcdev`/`mmchwpart`/`mmcpart`/`mmcroot`. Gap: `ffboot` sets
|
||
three of the four but never `mmchwpart` — it relies on the saved 0.
|
||
- **Default (compiled-in) env boots recovery**: `mmcdev=1 mmchwpart=1
|
||
boot_recovery=yes` — a blank or corrupt env lands in recovery mode, not a
|
||
brick. `bootcmd`: select mmc dev+hwpart → load and import `/boot/uEnv.txt`
|
||
from the selected partition → if `boot_recovery=yes`, boot kernel+DTB from
|
||
raw boot0 sectors, else load `/boot/zImage` from the slot's rootfs. U-Boot
|
||
polls the button at power-on for a recovery request.
|
||
- **boot0 map**: MBR / U-Boot @1 KiB / zeros @0x80000 / recovery DTB @0xC0000
|
||
(`fdt_dev_addr=0x600`, 64 KiB slot) / recovery zImage @0x100000
|
||
(`image_dev_addr=0x800`, 5 MiB slot, kernel 3.14.28) / recovery squashfs =
|
||
`boot0p1` @6 MiB (10 MiB slot). **boot1 map**: MBR / squashfs @1 KiB =
|
||
`boot1p1`, mounted as the recovery `/usr` (python runtime) by
|
||
`init.d/recovery-usr`.
|
||
- **Recovery userspace** = the factory setup webapp (bottle): WiFi setup/AP,
|
||
log export, `/version`, and `.fw` upload (→ tmpfs → `glowforge-updater -f` →
|
||
fwup signature check → writes slot A → flips env). It is never updated in the
|
||
field, so every machine still runs its as-manufactured recovery.
|
||
- **Factory `.fw` format** = signed fwup 0.14.2 archive (ZIP: `meta.conf` +
|
||
`meta.conf.ed25519` + payloads). Tasks: `complete` (MBR, U-Boot to user area,
|
||
zero both env copies, rootfs → slot A, zero p2/p3 heads) and
|
||
`upgrade.a`/`upgrade.b` (raw-write `rootfs.ext4` into a slot). Factory
|
||
updater flow: authenticated `GET <server>/update/current` →
|
||
`{version, download_url}` → resumable download to `/data/glowforge.fw` →
|
||
verify against `/glowforge/pubkeys` → apply to the INACTIVE slot →
|
||
`fw_setenv mmcpart mmcroot` → reboot. Factory `rootfs.ext4` is 65 MiB; the
|
||
ForgeFIRM rootfs is ~141 MB used, so it fits a 200 MiB slot with headroom.
|
||
- **Facts about the factory 2024 firmware** (learned during the slot install):
|
||
no `/factory/imgN` mounts, the generic `fw_env.config` points at the WRONG
|
||
device (use the per-device `fw_env_mmcblk2.config` — ffboot's selection
|
||
logic), no SSH (serial console only), and the factory kernel cannot see the
|
||
SD card (`ffboot -s` needs `-f` from factory). Factory `/etc/version` is a
|
||
numeric datetime stamp, so newest-slot selection is integer comparison.
|
||
- **Platform quirk**: busybox `mount`'s auto-type iteration against an
|
||
already-mounted ext4 device prints a kernel "`Can't open blockdev`" for each
|
||
foreign-type (ext3/ext2) exclusive claim before the ext4 attempt joins the
|
||
existing superblock. Cosmetic only; ffboot and the installer reuse existing
|
||
mountpoints from `/proc/mounts` and mount fresh targets with explicit
|
||
`-t ext4`.
|
||
|
||
## Next work
|
||
|
||
Open items only. Anything closed is in `CAMPAIGN-LOG.md`.
|
||
|
||
1. **Laser commissioning leftovers.** Verify the hardware button latch persists
|
||
across kernel-run gaps mid-job (if OK_2_FIRE drops between motion bursts, the
|
||
fix is a stream keepalive across armed gaps). The flow check's bands
|
||
hold from 19 to 27 C, the loop heater's ceiling in a 20 C room, with the
|
||
margin widening warm; above that only a running tube warms the loop,
|
||
and the check takes the tube's share off.
|
||
2. **Low-temperature gates and warm-up (planned).** Two keys in the Cooling
|
||
card: `cool_temp_min` (hard floor, default ~5 °C, a fire gate) and
|
||
`cool_temp_start` (warm-up gate, default ~16 °C) — a job starting below the
|
||
gate holds in a factory-style warm-up phase with the loop heater on and
|
||
releases above it; below the floor nothing fires. Rationale: cold-tube
|
||
thermal shock, condensation when the TEC pulls below the dew point, frozen
|
||
coolant. Sequencing: warm-up first, flow check after. Measured physics on
|
||
this bench: 50 % duty warms the bulk ~0.5–0.8 °C/min and plateaus ~8–9 °C
|
||
above ambient — the same unaided limit the factory has.
|
||
3. **TEC handling (planned).** `thermal/tec_on` is a bare on/off output with no
|
||
readback, so presence cannot be detected: it becomes a `tec_present` user
|
||
setting (Machine tab, default off; ForgeFIRM never drives `tec_on` unless
|
||
set), which also covers retrofits. Operation when present: simple hysteresis
|
||
while a job runs — TEC on above `cool_tec_on_c`, off below `cool_tec_off_c`,
|
||
defaults from the factory setpoints (CMet/CMdt 18134/18364 mdeg — the same
|
||
WTub/WTvb raw-754/751 pair that proved the thermistor curve), off at idle —
|
||
with `cool_temp_min` as the chill floor, so the TEC can never drive the loop
|
||
toward condensation or freeze territory. Whether a given unit has a TEC at
|
||
all is a spec-level claim (Glowforge ships it on the Pro; Basic/Plus use the
|
||
same passive closed-loop cooling), not teardown-verified per unit — another
|
||
reason it is a setting.
|
||
4. **Fire watch (lid IR) redesign.** The gate stays disabled
|
||
(`cool_fire_ir_delta = 0`) until it is lamp-aware: the engine must own or
|
||
observe the lamp level (suspend the watch and re-baseline for a few ticks
|
||
after any `lid_led` change) and the threshold must be relative to the
|
||
lamp-set level, not a fixed count. Even then the signal is weak — a candle
|
||
reads like a cut — so the head camera or a real flame sensor is the honest
|
||
path to fire detection that means something.
|
||
|
||
One lead worth a bench hour before building anything. The cloud ships flame
|
||
thresholds in every pulse header, and the numbers do not look lamp-naive:
|
||
baseline 3 counts on all four channels, alert at 275 and critical at 688 on
|
||
the first quartile, 374 and 1022 on the second, with the third and fourth
|
||
left at zero. Measured lamp response on this bench is 0 counts to 2, 131 to
|
||
58, 255 to 180, so the factory's alert sits above the reading a fully lit
|
||
lamp produces and its baseline matches the lamp-off floor. If that holds,
|
||
the factory rides out the lamp by choosing thresholds above it rather than
|
||
by tracking it, and the watch could be re-armed on fixed numbers after all.
|
||
Unproven: it assumes the header's quartiles map onto the raw channels and
|
||
share their units. Confirm both by reading the four channels while stepping
|
||
the lamp, then compare against the header the next cloud job carries. By
|
||
decision those header thresholds (`IR??`) are the prior for this redesign
|
||
and nothing else: the cloud client declares them ignored, and the watch
|
||
stays disabled until it is lamp-aware.
|
||
5. **Limit-switch homing.** The planned second homing method (`$22` stays 0
|
||
until it lands); printable brackets are in `3d-models/`. Also: calibrate
|
||
`gfcloud_home_x/y` against a jog to a known reference if the factory corner
|
||
offset matters.
|
||
6. **Cameras.** **First light on an 8 MP (OV8856) machine**: the
|
||
whole path is written but nothing has run on one, and only that hardware can
|
||
answer whether the 2-lane RAW8 full-resolution mode locks the D-PHY at
|
||
720 Mbps/lane and what exposure/gain the sensor wants; the details, the
|
||
reachable-mode reasoning and the factory fallback configuration are in
|
||
the headers of kernel patches 0011-0013 (`meta-glowforge-bsp`,
|
||
`recipes-kernel/linux/`). Also unapplied: the factory's **per-unit lens-shading
|
||
calibration**, an OmniVision LENC register file the factory pushes into the
|
||
sensor at every stream start (`load_cam_regs.sh` → a `regs` sysfs attribute
|
||
its driver adds; OV8858 `0x58xx` addresses remapped to the OV8856's
|
||
`0x59xx`). The files are per-machine data, not in the factory rootfs — look
|
||
for them under `/data` on a machine booted into the factory slot before
|
||
deciding whether to reimplement the mechanism. Finally the deferred emulator
|
||
homing-image smoke, now that the emulator can be pointed at live snapshots.
|
||
7. **Cloud mode.** A print is no longer capped by the ring: the client holds
|
||
the compressed body, fills the ring before the button, and tops it up as it
|
||
plays, with the body bounded by `pulse_reject_threshold_bytes` because
|
||
memory is what that costs. A feed that wedges is caught by progress rather
|
||
than by ring depth (a healthy feeder keeps the ring brim-full, so depth
|
||
only falls an hour after the feed died): thirty seconds of no progress with
|
||
room in the ring stops the job cleanly and retraces, and it resumes if the
|
||
feed moves again. A running print also reports itself to the app again, on
|
||
the carrier a factory-session capture settled: the `type:"progress"` frame
|
||
that is the periodic settings report, every 30 s and at every phase change,
|
||
divided by the job's own length rather than by the kernel byte counter that
|
||
climbs all job long under a live feed. The `cloud.*` acceptance tests
|
||
cover all of it on the bench, a print longer than the ring fed from the
|
||
live service included, and the app has been watched reporting a print's
|
||
progress. `gfcloud.init` autostart with `controller_mode = cloud` is
|
||
validated on a flashed image, and the lid flash follows the action's
|
||
`LCfl`. What is left is tracked in
|
||
`python3-gfhardware/forgefirm-app/docs/CLOUD.md` "Outstanding items" and
|
||
is short: whether the service accepts an 8 MP machine's larger images (no
|
||
HD machine has been on the bench). The pulse header's envelope is
|
||
settled: every tag the service fills in is applied, passed through as a
|
||
limit that can only tighten, refused on, logged or declared ignored with
|
||
its reason (`CLOUD.md` "The pulse header"), and the gates behind it live
|
||
in the cooling engine so they hold in GRBL mode too. The memory guards
|
||
(`pulse_reject_threshold_bytes`, 128 MiB of compressed body) stay
|
||
reasoned rather than measured, by decision: nothing the service sends
|
||
comes near them, and every job logs the body and program sizes the
|
||
guards are reasoned from. The lifecycle keys (`CFrh`, `CCwp`, `CCrp`,
|
||
`CCup`) are settled as inert, in the factory too, so the configured
|
||
warm-up and rest on the factory's measured timings are the model, and
|
||
`CCbp`/`CCbt` are report-only tags that cannot appear in a header. The
|
||
four actions the service has never been seen to send were read out of
|
||
the factory binary: `user_image` is a lid capture and is implemented;
|
||
`update_check`, `factory_reset` and `head_firmware_update` each hand off
|
||
to a program this machine does not have (a factory updater, a reset
|
||
script, a head firmware push), so each is answered on the wire and none
|
||
is performed, and `focus` is ignored exactly as the factory ignores it.
|
||
Declined outright: SPKI pinning, emulator full-session parity, and the
|
||
factory's ten-event pause phase machine. Not inducible from the bench:
|
||
the cancel-with-a-rejected-`settings`-action case, a malformed frame
|
||
(needs a MITM), a body past the memory guard (the service has no such job
|
||
to send), and a wedged feed (a healthy machine will not stall on request).
|
||
8. **Shared machine services — remaining polish.** None of it blocking:
|
||
- **Diagnostics as engine modes.** The flow tools still drive the thermal
|
||
hardware themselves while the engine suspends its writes; the check
|
||
parameters are already shared (`cool.h`), so what remains is folding the
|
||
tools into the engine and retiring the suspend/resume dance.
|
||
- **Rail policy** (the one `[contract]` item left in SERVICES.md). The GRBL
|
||
driver still writes `cnc/enable` at init and at homing resume —
|
||
idempotent, since the rail is already up, so this is tidiness rather than
|
||
a bounce source.
|
||
- **Busy-state arbitration under one lock.** The idle/busy gates (`POST
|
||
/settings`, `/mode`, diagnostics start, upload/apply) each cross-check
|
||
`machine_is_idle()` and `update_job_running()` at their own call sites.
|
||
They fail closed and are drilled, but a single arbiter would close the
|
||
remaining request-interleaving windows by construction.
|
||
- **HTTP surface caps.** An explicit `MHD_OPTION_CONNECTION_LIMIT` plus a
|
||
per-IP cap is the right hardening (a 500-connection flood plateaued at 379
|
||
fds under the raised 4096 `RLIMIT_NOFILE`, no crash), and the camera
|
||
`ensure_engine` `popen()`s should move out of the HTTP callback so a slow
|
||
media-ctl cannot stall the request thread. Changing the MHD start flags
|
||
touches the streaming model, so this wants a bench slot of its own.
|
||
- **`/cool/status` cosmetics.** The endpoint echoes the last reported `armed`
|
||
flag even when that report is stale (`report_age_s` tells the truth), and a
|
||
gfcloud homing session reports every motion as a job, so the engine cycles
|
||
run → smoke → idle per motion. Both are silent and safe.
|
||
9. **Physical-evidence negatives still open.** A present head answering I²C
|
||
badly (the K-11 runtime case) and a failed head capture leaving the measure
|
||
laser off — both need the head connected and a fault injected. Opportunistic:
|
||
`STATE_FAULT` recovery via `enable` the next time a DRV8825 fault line
|
||
actually trips.
|
||
10. **Debug-kernel checks.** Module load/unload under `CONFIG_DEBUG_MUTEXES`
|
||
and a forced `-EPROBE_DEFER` unwind still need a debug kernel build.
|
||
11. **Wi-Fi SDIO CRC watch.** The uSDHC pads now carry the factory-exact values
|
||
and ship in every image. Watch `dmesg | grep -c "sdio .* failed"` across
|
||
sessions (baseline: 1 event in 49 min of uptime). Effect if one lands
|
||
mid-job: a 1–2 s sender stall — a cut-quality nuisance, never a safety
|
||
matter. Only if it still recurs, cap the bus with
|
||
`max-frequency = <25000000>` on `&usdhc1` (halves Wi-Fi throughput — last
|
||
resort; the factory ran 50 MHz on these pads).
|
||
12. **Release acceptance follow-through.** The campaign is the release gate
|
||
and runs as designed: dev image `20260824230512`, 45 of 45 from nothing,
|
||
36 of them unattended with the bench actuator in the loop, release
|
||
authorized (the export is on the board at `/data/forgetest/export/`).
|
||
What is left is small. The ported bench tools are registered and
|
||
unit-tested but not yet driven from the page. Two catalog gaps from the
|
||
tool's own plan, `cooling.confirm-escalate` and
|
||
`cooling.fire-gate-blocks-arm`, are not ported (both need the pump
|
||
switched by hand mid-run, so they are bench-tab material first), and
|
||
whether `laser.armed-kill` belongs in the always-required core rather
|
||
than its domain is still an open call (the core carries the emission
|
||
witness). From the coverage maps: splitting gfutilities' `websocket.py`
|
||
into transport and transfer helpers would take websocket-transport
|
||
changes off the offline tests (a gfutilities refactor, not a map).
|
||
Tools that genuinely need a second host (LAN flood, remote auth probes)
|
||
stay host-side by design, and the registry marks them so. The first
|
||
release is item 13.
|
||
13. **Publish.** The first release: `releases/v<version>/acceptance.json`
|
||
from the authorized export, `scripts/release.sh`, the kas flip and the
|
||
first GitHub release, per the site (Developers, "Release flow"), once
|
||
ready to publish. Repoint the core submodule to
|
||
upstream if the `step_us_min` sizing fix merges.
|
||
14. **Update system Phase 5 — recovery refresh.** The remaining phase of
|
||
`docs/UPDATE-SYSTEM.md` (a refreshed recovery image in boot0); Phases 0–4
|
||
are done.
|
||
15. **Head-IRQ source validation — beam-emission hypothesis (exploratory, not
|
||
gating).** The EV_SW `head` bit (GPIO3_22, factory pad HEAD_IRQ) is the head
|
||
MCU's attention line — idle LOW with a healthy head, pulsing on head reboot,
|
||
floating to the SoC pull-up with no head — so the raw level is not a
|
||
presence signal (presence = the head answering at I²C 0x47). The factory app
|
||
answers the IRQ by reading the head's flag register (reg 0x05: b0
|
||
hall_sensor, b1 accel_irq, b2 beam_detect_digital), so there are exactly
|
||
three candidate sources; the working hypothesis is the head's IR
|
||
beam-emission detector (digital flag + analog level reg 0x16, both already
|
||
head sysfs attrs; the tunable detection model at regs 0x22–0x2a is not
|
||
exposed). Whether the factory actually uses beam detect is unknown — the
|
||
v2.6.0 app carries a complete but config-gated subsystem — and detection at
|
||
low fire energies is unverified. Cheap opportunistic check during live fire:
|
||
log EV_SW head-bit edges plus `head/beam_detect_digital|_analog` while
|
||
firing.
|
||
|
||
16. **Laser power model: dose by FIRE-bit density.** grblHAL maps S onto the
|
||
analog PWM duty (`$30`/`$31` → `$35`/`$36`, written raw into PWMSAR against
|
||
the 127-count period). `$35` now ships at 16, the measured lasing
|
||
threshold (facts bank), which keeps M4's velocity-scaled power out of the
|
||
dead band at corners, reversals and segments shorter than the
|
||
accelerate-in-and-out distance (~1.6 mm at 2000 mm/min with the default
|
||
700 mm/s²) — where an unfloored duty is commanded below the threshold and
|
||
does not burn at all.
|
||
|
||
The floor is a patch on a model this tube does not fit. Only 16–100 % of
|
||
the duty range does anything, so analog control has a ~6:1 span, and the
|
||
floor buys freedom from dropout by putting its full 16 % into corners
|
||
where velocity — and dose per unit length — goes the other way. The
|
||
factory does not use duty as a power control at all: all five firing jobs
|
||
in the captured pulse files pin the power byte at 127 (one also uses 102)
|
||
and modulate dose entirely by dithering the FIRE bit at the 10 kHz tick,
|
||
at 6.5–18.8 % density. The measured dead band is why. Dose set by pulse
|
||
density cannot fall below the lasing threshold by construction, which is
|
||
what the per-tick FIRE bit exists for, and it is the only power model this
|
||
tube and supply are known to work well with. The duty → optical-power
|
||
transfer function is still unmeasured — nothing has ever depended on it.
|
||
|
||
The factory's implementation is now measured rather than inferred (facts
|
||
bank): power byte pinned at 127, dose set by a fixed 7-tick period
|
||
(~1.43 kHz) whose on-count is dithered between adjacent integers, and a
|
||
velocity compensation that is real but partial. Two things follow for the
|
||
ForgeFIRM implementation. The base period is a free parameter — the
|
||
factory's 700 µs is 7 ticks at its 10 kHz print rate, and GRBL mode ships
|
||
the stream at 28 160 Hz, so the same PRF is ~20 ticks; the accumulator, not
|
||
the period, is what recovers fractional density. And velocity scaling
|
||
arrives for free: under M4 the core already scales S by velocity, so
|
||
mapping S onto density inherits compensation that is *more* complete than
|
||
the factory's, which still lets dose per unit length rise ~1.8× at a
|
||
corner.
|
||
|
||
The model itself is implemented and host-proven, off by default
|
||
(`laser_power_model`, above). What the harness holds: density renders
|
||
the commanded level exactly (level/127 to four decimals at every rung),
|
||
no level ever reaches PWMSAR, a level change inside a run costs no
|
||
stream byte where analog pays one each, and - run against the same job
|
||
under both models - the motion grid is identical and every density FIRE
|
||
tick is one the analog run also fired, so the model only ever masks.
|
||
|
||
**Both dose and pulse length matter, in different regimes.** Four
|
||
ladders run with no minimum pulse (F300 at periods 20, 40 and 10, then
|
||
F100 at 20) put the same six rungs on the material every time - 20 %
|
||
and up - and their matched pairs looked like a clean answer: at
|
||
identical pulse length, halving density killed the mark; at identical
|
||
density, varying pulse length 3x changed nothing; and feed did not move
|
||
it either, 10 % at F100 carrying 44 % more energy per millimeter than a
|
||
marking 20 % at F300 and still leaving nothing.
|
||
|
||
That reading was too broad. Every one of those comparisons sat at or
|
||
above 20 % density, where the pulses in play were already long enough.
|
||
A fifth ladder with a 3-tick minimum moved 10 % from nothing to a mark
|
||
at the **same density and less dose**, purely by lengthening its pulses
|
||
from 36-71 us to 106 us. So above ~100 us the outcome follows dose;
|
||
below it pulse length dominates - too short and the energy does
|
||
nothing, shorter still (36 us, one tick) and the supply does not strike
|
||
at all, which the `hv_current` trace showed as a rung with no discharge
|
||
for its full 15 s. That is what the factory's 100 us quantum protects,
|
||
and what `laser_pulse_min_ticks` now protects.
|
||
|
||
With a minimum in place the low end is decoupled from the base period,
|
||
so the period is free to be chosen on other grounds. It stays at 20.
|
||
|
||
**The low end is a scaling problem, not a modulation one.** The band
|
||
this tube gives is ~5 % density to strike and ~10 % to mark (facts
|
||
bank); below that the pulse interval outruns the discharge whatever the
|
||
pulse shape. So a commanded 1 % can only be made useful by mapping it
|
||
onto that band, which is what the factory does and what `$35` is under
|
||
this model.
|
||
|
||
**The defaults are flipped:** `laser_power_model` defaults to `density`
|
||
with a 10 % floor (`laser_floor_density`), so a stock machine runs the
|
||
model and a commanded 1 % marks. The analog path remains as
|
||
`laser_power_model = analog` or `M101 P0` in a job, with its own floor
|
||
key (`laser_floor_analog`, 16); the controller derives `$35` from the
|
||
selected model's key at every arm and switch, so no floor is typed and
|
||
no mismatch exists ("Laser control (GRBL mode)" above).
|
||
|
||
Owed: validation at production feeds. Every ladder behind these
|
||
defaults ran at F300 or F100, where dose per millimeter is generous and
|
||
the power is constant - none of them exercised M4's velocity scaling
|
||
into corners, a real sender's level changes, or the raster path, which
|
||
has not run at all. The arithmetic says dotting will not be the
|
||
problem (at 10 % density the pulse interval is 1.07 ms, which at
|
||
2000 mm/min is 35 um against a ~200 um spot), but that is reasoning,
|
||
not a cut.
|
||
|
||
For reference, the factory maps its whole 1-100 power
|
||
scale onto density 18.9-79.5 % (fit from the three captures; Full Power
|
||
is off that line at ~99.7 %), so its "1 %" is the bottom of the band
|
||
that does useful work rather than 1 % of the physical range. Under the
|
||
density model `$35` and `$36` are exactly that control - a density
|
||
floor and ceiling - so the scale is a settings choice, not new code.
|
||
The floor's value wants one more ladder: the step from 10 % to 20 % is
|
||
coarse, and the factory's own answer is 18.9 %. Note the captures also
|
||
run 6.5-18.8 % density on other jobs, so that intercept is a product
|
||
decision about cutting, not a physical limit - which is why the
|
||
minimum-pulse fix matters for the raster low end regardless of where
|
||
the cut scale starts. The factory never emits a pulse shorter than
|
||
100 us; a tick here is 35.5 us, and every pulse restarts the discharge,
|
||
so each carries the strike transient the threshold ladder made visible
|
||
- dose per pulse is therefore probably not proportional to pulse length
|
||
and density -> dose may be superlinear at the low end. A density ladder
|
||
on scrap at two or three `laser_pulse_ticks` values answers both that
|
||
and the shortest pulse that marks reliably. grblHAL is userspace, so it
|
||
deploys by replacing the binary; no image flash. Then the raster path
|
||
below.
|
||
|
||
What that model means for image engraving, since it decides the design as
|
||
much as cutting does. LightBurn has two image paths. Its 1-bit modes
|
||
(Dither, Stucki, Jarvis, Halftone, Ordered) dither in the image domain and
|
||
emit only `Smax` or 0, so density is solid whenever a dot is on. Grayscale
|
||
mode emits a level per pixel, and that is the path the present duty model
|
||
breaks worst: dark pixels map below the striking threshold and mark
|
||
nothing, so shadows do not fade, they drop out. FIRE-bit density fixes that
|
||
by construction — a low level becomes sparse full-power pulses, every one
|
||
of which marks. Three consequences to design around:
|
||
- **Tonal resolution is set by ticks per pixel**, `rate × pixel_mm ÷
|
||
speed_mm_s`: 56 ticks at 254 DPI and 3000 mm/min, 14 at 508 DPI and
|
||
6000 mm/min. Fine, fast rasters have few pulse slots per pixel and lose
|
||
levels. The factory works at 10 kHz with ~20 ticks per pixel at 254 DPI,
|
||
so this envelope is livable, not comfortable.
|
||
- **The dither accumulator must carry across pixels**, so a level too fine
|
||
to express inside one pixel still averages over a run of them — that
|
||
spatial averaging is what recovers the levels the arithmetic above
|
||
loses. It follows that the accumulator resets only on fire-off, run
|
||
boundaries, disarm and abort, never per pixel.
|
||
- **A 1-bit image run below full layer power stacks two dithers**, and a
|
||
plain integer carry repeats on a short period, so it can beat against
|
||
LightBurn's own pattern as moiré. Perturbing the accumulator removes the
|
||
short period; the workflow answer is that 1-bit modes belong at 100 %
|
||
power with darkness set by speed, where density is solid and no second
|
||
dither exists.
|
||
|
||
Rasters also gain from the model directly: a level change costs a power
|
||
byte in the stream today, and the feeder contract forbids back-to-back
|
||
power bytes, while under FIRE dithering the duty is a constant sent once
|
||
per run and a per-pixel level change costs no stream byte at all.
|
||
17. **Gapless pause and resume in GRBL mode (planned).** A pause leaves a mark
|
||
in the cut. With laser mode on, the core stops the beam at the start of the
|
||
hold (`disable_laser_during_hold`, on by default), so the head travels the
|
||
whole deceleration dark, and the resume re-accelerates from a standstill at
|
||
the point the decel ended — an unburned length, then a restart that dwells
|
||
through the accel. At constant power (`M3`) that restart is a deeper spot
|
||
you can see; `M4` scales power with velocity and mostly hides it, but
|
||
neither closes the gap. GRBL mode should pause and resume with no
|
||
discontinuity in the cut, the way the factory does.
|
||
|
||
Cloud mode already does, on the kernel's waypoint resume: controlled stop,
|
||
laser-off backtrack (`cloud_pause_backtrack_ticks` 2000), then a laser-off
|
||
lead back up to speed on the next press (`cloud_resume_lead_ticks` 1950),
|
||
so the beam returns only once the head is retracing ground it already cut
|
||
and is back at feed. The kernel offers that mechanism to a live feed as
|
||
well: what bounds a backward run is the ring's retained history, not how
|
||
the ring was filled, and the 32 KiB the writer must leave clear is 3.2 s of
|
||
history at the print tick (`cnc/max_backtrack`, `UAPI.md`). What is not
|
||
settled is the bookkeeping above it: a backward run moves the head and the
|
||
kernel's counters while grblHAL's planner still holds a partly executed
|
||
block, so borrowing the mechanism means reconciling the two, and a GRBL
|
||
cut runs a much shorter queue than a cloud print does.
|
||
|
||
So the equivalent likely belongs above the ring, where grblHAL still holds
|
||
what the kernel does not: the planned path. Shape to evaluate: capture the
|
||
point where the beam went off at the hold; on the resume plan a laser-off
|
||
retrace back along the path and a laser-off accelerate-in, and unmask FIRE
|
||
only once the head is at feed and has passed the captured point. Open: how
|
||
far back is enough (2000/1950 ticks is a reference, not a transferable
|
||
number — the tick rates differ), whether the retrace can reuse planner
|
||
blocks or needs a synthesized one, what a hold inside an arc or a raster
|
||
line does to it, and how it composes with the armed window's disarm grace
|
||
across a long hold.
|
||
|
||
18. **Head crash and rail-contact detector (planned).** The head
|
||
accelerometer is the motion-liveness probe and nothing more; the
|
||
factory runs two tiers off the same sensor (a per-axis alert that
|
||
pauses, a per-axis abort), and its thresholds arrive in every pulse
|
||
header in a unit and behind a filter that are not known. A detector
|
||
here is bench-measured from scratch, not adopted from the header: the
|
||
rail-contact signature in the facts bank (a 20 to 40 times jump within
|
||
4 ms on a fast strike, near-silent on a slow one) is the starting
|
||
point, and the header values are only a cross-check once the units
|
||
are established. A pause on contact, on the factory's shape, would be
|
||
the first use.
|
||
|
||
19. **Image trims not taken.** Two rootfs reductions the kernel review left
|
||
on the table, each wanting a check before it lands. The `python3`
|
||
meta-package installs `python3-modules` (tkinter, idle, 2to3, pydoc,
|
||
ensurepip, venv, the debugger, doctest, asyncio, multiprocessing,
|
||
xmlrpc: ~10 MB) where the apps declare `python3-core` and a few modules,
|
||
so replacing it with the explicit set needs an import audit of gfcloud,
|
||
gfhome, gfhardware and gfutilities (the cloud tests are the check).
|
||
`libgnutls30`, `libunistring5`, `nettle` and `libgmp10` (~4.9 MB) sit on
|
||
the rootfs with no package depending on them and no binary linking them;
|
||
a `PACKAGE_EXCLUDE` experiment on a build would name the holder if there
|
||
is one. Five helper modules are built and not shipped (`crc7`,
|
||
`crc-ccitt`, `libcrc32c`, `st-accel-spi`, `st-sensors-spi`: 0.1 MB,
|
||
harmless). The debug features stay in the release kernel by decision
|
||
(`KPROBES`, `PERF_EVENTS`, `BPF_SYSCALL`, `DEBUG_FS`, `DEVMEM`,
|
||
`MAGIC_SYSRQ`: no runtime cost unused, root-only exposure, and root can
|
||
load modules anyway).
|
||
20. **A sender change while a job runs: discussion.** Today a sender that
|
||
disconnects mid-job leaves the motion running to the end of what the
|
||
controller holds, with the window closed and fire suppressed (the
|
||
consent belonged to the displaced session), so the job finishes dark
|
||
and the material is left with an unfinished cut. This is the stock
|
||
Grbl and grblHAL expectation for the motion: the controller has no
|
||
notion of sender presence, executes what its planner and RX ring hold,
|
||
and then waits; the core's stream code (`stream.c`,
|
||
`stream_disconnect`) only switches streams, with no hold and no
|
||
alarm, and senders treat a lost connection as a failed job (LightBurn
|
||
stops its own side and resumes nothing). ForgeFIRM adds only the
|
||
disarm on top. The open question is whether the disarm should also
|
||
feed-hold the job, so a reconnecting sender can press and resume where
|
||
the cut stopped instead of finding the head at the end of a dark pass:
|
||
a hold parks the head over hot material with the assist air on the run
|
||
profile, and the grace then closes the window in Hold as it does today;
|
||
running on leaves a clean stop position but wastes the piece. Decide
|
||
with the gapless pause and resume item (17), which owns the resume
|
||
mechanics.
|
||
21. **The flow check while the tube is lit.** The arm-time heater check
|
||
starts at the session open, so with a prompt press the tube is lit
|
||
for most of its window, and a lit CW window adds about 1.5 C to the
|
||
rise (0.5 C at 45 % density) against a 1.6 C margin; on top of that the
|
||
engine takes its baseline from one sample while the coolant ADC
|
||
carries a common-mode offset of about 1 C that steps in when the
|
||
airflow goes to the run profile, steps out when it returns to idle,
|
||
and toggles between two levels in between. Together they put an
|
||
ordinary job's check within a few tenths of the limit. The engine now
|
||
reads means and takes the tube's share off (`cool_laser_heat_cw`,
|
||
`cool_laser_heat_density`), and `cooling.flow-under-load` is the
|
||
catalog's case. Owed: a re-measure of the two coefficients once a
|
||
second machine is on the bench (one tube, one supply so far); and if a
|
||
lit check still trips, the void-on-emission design with the tube as
|
||
its own flow tracer.
|
||
The offset's source is the air-assist fan's return current on a ground
|
||
path the thermistor reference shares (about 1.2 C at the run duty,
|
||
proportional to the fan's current, both sensors alike; not crosstalk
|
||
on the sensor cable and not HV). The check cancels it now that its
|
||
baseline is taken under the run profile, but the over-temperature
|
||
gates read the coolant about 1.2 C cooler than it is while the air
|
||
assist runs unless `cool_aa_offset_counts` carries the machine's value
|
||
(the `aa-offset-calibrate` diagnostic measures it, the panel's Apply
|
||
writes it; zero is the factory's uncorrected reading; the bench
|
||
machine carries 16). Owed: a second machine's value when one is on
|
||
the bench; and the mid-run
|
||
toggling between two levels (0.6 to 1.1 C, both sensors together),
|
||
which comes only with the tube lit: not with the fans alone, not under
|
||
motion, not in an armed dark window. The HV supply's input current on
|
||
a return the thermistor reference shares, or its switching, is what
|
||
remains; a scope on the two sensor lines during a cut is the next
|
||
instrument. It sits inside the ceiling's 2 C hysteresis and the flow
|
||
check reads means, so it is a measurement item, not a gate item.
|
||
22. **Laser power-good: what the line means.** `cnc/laser_pgood` and its
|
||
sampled count are defined in the UAPI (active low, one sample every
|
||
~3.9 ms), the facts bank records that the sampled count reads 0 through
|
||
real cutting, and the cooling engine warns
|
||
`laser power-good degraded during the armed window` whenever fewer
|
||
than half the samples read low, so the warning fires at every session
|
||
open and carries no information. Nobody knows what the line reports
|
||
on this PSU: whether it is the supply's own power-good, an HV-present
|
||
flag, a polarity we have inverted, or unconnected. Owed: the line on a
|
||
scope against `hv_current` through an armed cut, its meaning written
|
||
into the facts bank and the UAPI, and then either a warning that means
|
||
something or no warning.
|
||
23. **Initial commissioning: measure and set the machine's own numbers
|
||
methodically.** Every tunable that was measured on the bench machine
|
||
and shipped as a default varies from machine to machine: the flow
|
||
check's bands and `cool_flow_rise`, the tube's heat coefficients
|
||
(`cool_laser_heat_cw`, `cool_laser_heat_density`), the air-assist
|
||
ground offset on the coolant readings, the laser's striking and lasing
|
||
thresholds and the duty floor, the fan floors, the thermistor curve
|
||
itself. Owed: one commissioning procedure, run once on a new machine
|
||
from the panel or the bench page, that measures each of these in
|
||
order with the tube dark wherever it can be, fires only where it
|
||
must, and writes the results as that machine's settings with a
|
||
record; and a reading of what the cloud sets for the same machine,
|
||
taken from cloud cuts (the pulse header carries the factory's
|
||
per-machine values), so the commissioning can start from the
|
||
factory's own numbers where they exist and note where they differ
|
||
from the measured ones.
|
||
|
||
**Deliberately not gated:** an armed GRBL job after an underrun cuts at the
|
||
stale origin unless homing is required (GRBL mode permits unhomed cutting; the
|
||
underrun itself alarms and unlinks the anchor). Not in the acceptance catalog
|
||
by design, for the same reason. From the pulse-header envelope, each by
|
||
decision and each declared in the cloud client so every job's log counts it
|
||
as decided rather than missed: the warm-up fan profile (the run profile
|
||
covers the warm-up hold), the supply temperature window (the service sends
|
||
the whole ADC range and the factory binds it to nothing; the supply is
|
||
watched per job instead), the head, lid, interconnect and fused temperature
|
||
ceilings (no sensor at those locations; the chassis is watched per job), the
|
||
head accelerometer thresholds (item 18), the lid IR thresholds (item 4), the
|
||
HV current caps (the sampled emission witness covers the idle case, and HV
|
||
current is ranged per job), the thermal report upload conditions and the
|
||
pump flag. Beam detect stays with item 15.
|