MOTION said jogs, homing and hunts were all ungated. Jogs are: gfsw_visible withholds the door signal while the core is idle, jogging or homing, so a jog both starts and runs with the lid open. Homing is not. With homing_mode = gfcloud - the only method that works today - $H hands the cycle to a cloud homing session, and its move to the home corner is an ordinary motion action taking the default lid_gated=True: refused with the lid open, stopped on a lid edge mid-run. Only the lens/Z hunt inside that session passes lid_gated=False, and that session is also the only place a hunt happens in GRBL mode - there is no hunt outside one. BRINGUP gains item 18: GRBL pause and resume should leave no gap in the cut, the way the factory's does. The beam stops at the start of the hold (disable_laser_during_hold, on by default), so the head travels the whole deceleration dark and the resume restarts from a standstill where the decel ended - an unburned length, then a dwell through the accel that M3 shows as a deeper spot. The kernel waypoint backtrack cloud mode uses is refused with EPERM on a live-streamed ring, so the equivalent has to be built above the ring, where grblHAL still holds the planned path the kernel has already overwritten. Two wording fixes: the cooling verdict is described as a report rather than a file, and gfcloud homing as using the machine's builtin credentials. Documentation only - no behavior change, so no acceptance-catalog consequence.
367 lines
17 KiB
Markdown
367 lines
17 KiB
Markdown
# Cooling and airflow
|
||
|
||
The tube is water-cooled and the enclosure is air-cleared, and both matter
|
||
while the laser fires: coolant that has stopped circulating will let a tube
|
||
overheat within a cut, and smoke that is not pulled out spoils the work and
|
||
fogs the optics. ForgeFIRM runs this as one service — the **cooling engine** —
|
||
that owns every piece of thermal hardware and answers one question at a time
|
||
for whichever controller is running: *is it safe to fire right now?*
|
||
|
||
This page explains what the system is made of, how it decides, what you will
|
||
see when it intervenes, and what you can tune.
|
||
|
||
- The beam itself is gated in hardware; see [Laser safety](SAFETY.md).
|
||
- For how the laser and motion are driven, see [Motion and laser drive](MOTION.md).
|
||
|
||
---
|
||
|
||
## 1. What the hardware is
|
||
|
||
**The coolant loop** is closed: a pump, a radiator with fans, the laser tube,
|
||
and two thermistors — one **upstream** of the tube and one **downstream** of a
|
||
small inline heater. Pro machines are specified with a thermoelectric cooler
|
||
(TEC) on the loop; the board cannot tell whether one is fitted (§9). The
|
||
heater exists for diagnostics, not for warming the machine up: it is
|
||
how the engine proves the coolant is actually moving (§4).
|
||
|
||
**The airflow path** has four independently driven pieces:
|
||
|
||
| Piece | What it does |
|
||
|---|---|
|
||
| Exhaust blower | pulls smoke out of the enclosure |
|
||
| Two intake fans | feed clean air in behind it |
|
||
| Air assist (in the head) | blows the cut line clear at the focal point |
|
||
| Purge air (in the head) | keeps the optics clean; on whenever the machine is on |
|
||
|
||
Every fan reports a tachometer, so the engine can tell a commanded duty from an
|
||
actual airflow, and the panel shows real speeds rather than setpoints.
|
||
|
||
**Coolant temperature is read, not guessed.** Both thermistors are converted
|
||
with the factory's own beta-equation curve, checked against a thermometer. A
|
||
sensor reading at either rail is treated as open or shorted — not as a
|
||
temperature.
|
||
|
||
---
|
||
|
||
## 2. One owner, two clients
|
||
|
||
The cooling engine lives in `forgectrl`, the machine-services daemon, and it is
|
||
the **only** thing that writes fans, pump, TEC and heater. Whichever controller
|
||
is running — GRBL or cloud — is a client of it, over two channels:
|
||
|
||
- **The controller reports its job state** about once a second: idle, running
|
||
or cooling down, whether the laser is armed, and (in cloud mode) the fan
|
||
duties the job asks for. The reports are level-triggered, so a lost one
|
||
simply corrects itself on the next.
|
||
- **The engine publishes a verdict** the controller reads and enforces in its
|
||
own process: may the laser fire, should the job hold, may it resume.
|
||
|
||
Two properties of that split are worth understanding, because they explain the
|
||
machine's behavior in odd situations:
|
||
|
||
**A missing verdict is a bad verdict.** If the report is absent or more than two
|
||
seconds old, a controller treats it as *fire blocked, hold*. The engine going
|
||
away looks exactly like a fault, never like permission.
|
||
|
||
**Arming requires being seen.** The engine only grants fire when it is
|
||
receiving fresh job reports. A controller about to fire is, by contract, one
|
||
that is reporting — an armed window the engine cannot see never gets a green
|
||
light.
|
||
|
||
**If a controller goes silent** past five seconds, the engine blocks fire
|
||
immediately and stands the machine down through the normal cooldown, because a
|
||
smoke clear is the right physical response to a job that died mid-cut. If the
|
||
silence happens while the laser is armed, or while the pulse engine still says
|
||
a program is playing, the engine additionally stops motion and locks the laser
|
||
latch itself. It also refuses to let exhaust and intake drop below cooldown
|
||
duty while a program is still running.
|
||
|
||
**If a diagnostic takes the hardware over** (§6), the engine suspends its own
|
||
writes and publishes fire-blocked until the diagnostic finishes.
|
||
|
||
**If the engine itself is provably gone** while the laser is armed, the
|
||
controller writes the factory run duties to the fans once, holds the job, and
|
||
stands down. That is the single sanctioned exception to single-owner control,
|
||
and the duties are compiled in so that a lost configuration file cannot take
|
||
the fans with it.
|
||
|
||
---
|
||
|
||
## 3. What the fans do, and when
|
||
|
||
The engine runs in phases. Duties are the factory machine's own values.
|
||
|
||
| Phase | Pump | Air assist | Exhaust | Intake | Heater |
|
||
|---|---|---|---|---|---|
|
||
| **Idle** | on | 204 | off | off | off |
|
||
| **Run** (or armed, whatever the reported mode) | on | 1023 | 65535 | 43278 | flow checks only |
|
||
| **Cooldown — smoke clear** (15 s) | on | run duty | run duty | run duty | off |
|
||
| **Cooldown — thermal** | on | idle | 32768 | 21639 | off |
|
||
| **Over-temp / fault hold** | on | run duty | forced | forced | off |
|
||
|
||
Notes on the phases:
|
||
|
||
- **The pump runs whenever the machine is on**, including at idle. Circulation
|
||
is cheap; a stagnant loop with a warm tube is not.
|
||
- **The heater is off at idle by design.** An always-on flow heater measurably
|
||
warms the loop within minutes, eating headroom below the start gate for no
|
||
benefit while nothing can fire.
|
||
- **Being armed counts as running.** If the laser is armed, the engine forces
|
||
the run profile and the flow checks regardless of what mode the controller
|
||
reported — fire never happens without cut airflow and active flow
|
||
verification.
|
||
- **Cooldown has two stages**: a smoke clear at full run duty, then reduced
|
||
airflow (the radiator cools the loop measurably) until the upstream coolant
|
||
temperature is back under the resume gate or the cooldown budget expires.
|
||
- **The TEC is left off.** Its output has no readback, so the machine cannot
|
||
tell whether one is fitted; driving it blind is not something ForgeFIRM does
|
||
(see §9).
|
||
|
||
In **GRBL mode** the run profile follows your sender's `M8`/`M9` (LightBurn's
|
||
per-layer Air Assist), OR'd with the armed window. In **cloud mode** the job's
|
||
own header carries the duties and the client passes them through, so a print
|
||
gets the fan profile the service designed for it and a lens hunt stays quiet.
|
||
|
||
---
|
||
|
||
## 4. Coolant flow verification
|
||
|
||
### The problem
|
||
|
||
A pump can stop, an impeller can slip, a line can airlock — and none of it
|
||
shows up in a temperature reading until the tube is already in trouble.
|
||
Absolute coolant temperature only tracks a loop that is *circulating*, and
|
||
"coolant should warm up while cutting" is not a usable signal either: a light
|
||
engrave may add no measurable heat at all.
|
||
|
||
### The method
|
||
|
||
The small heater sits between the two thermistors. Each check runs it at a
|
||
fixed duty for a fixed window and watches how far the **downstream** sensor
|
||
climbs:
|
||
|
||
- **flowing coolant carries that heat away** — the downstream sensor rises a
|
||
little;
|
||
- **a stagnant loop cooks the sensor** — the downstream sensor rises a lot.
|
||
|
||
The discriminator is the rise, not the difference between sensors, and the
|
||
operating point is measured rather than assumed:
|
||
|
||
| Parameter | Value | Why |
|
||
|---|---|---|
|
||
| Heater duty | 40 % | Below about 40 %, natural convection sheds the heat well enough to *mimic* flow — dead-pump trials have looked healthier than a working pump. At 40 % heat input outruns convection, and it is the cheapest duty that does. |
|
||
| Window | 50 s | Long enough for the bands to separate cleanly. |
|
||
| Fault threshold | 14.4 °C rise | Midway between the observed flowing band and the observed stagnant band. |
|
||
| Re-check interval | 150 s | A pump that stops mid-job is invisible otherwise. |
|
||
|
||
Each check costs the loop under a degree of heating, and with cut-profile fans
|
||
running the loop still nets cooler over a long job.
|
||
|
||
### Checks start from a settled loop
|
||
|
||
Measuring a rise from a baseline captured while the loop is still cooling from
|
||
earlier heat produces garbage — and it fails in the dangerous direction: it can
|
||
report flow with the pump stopped. So a check is *requested*, and starts only
|
||
once the two sensors agree within 1.5 °C **and** the downstream reading has
|
||
stopped drifting.
|
||
|
||
Stationarity is judged by comparing the mean of the first half of a 15-second
|
||
window against the second half, not by peak-to-peak spread. On a settled loop,
|
||
peak-to-peak noise is about 0.5 °C while the split-half difference is about
|
||
0.1 °C — any peak-to-peak threshold tight enough to catch real drift would sit
|
||
below the noise floor and never open the gate.
|
||
|
||
### One bad reading is a suspicion, not a fault
|
||
|
||
Transients happen: cycling the pump by hand can burp an airlock that clears
|
||
itself within minutes. So the engine runs a two-step decision:
|
||
|
||
1. **First over-limit check → `COOLANT FLOW SUSPECT`.** A warning, a hold
|
||
request, and an immediate re-check — no waiting for the normal cadence.
|
||
2. **The next completed check decides.** Over-limit again, with no clean check
|
||
in between → `COOLANT FLOW FAULT`. Clean → the suspicion clears and the job
|
||
continues.
|
||
|
||
Two more rules close the loopholes:
|
||
|
||
- **A suspicion that cannot resolve escalates.** If no verdict can be produced
|
||
within the confirmation budget (default 480 s), it becomes a fault: a loop
|
||
that will not settle after a fault-level reading has shown no evidence of
|
||
health.
|
||
- **Cleared suspicions still count.** Three of them in one job earn an
|
||
aggregated "check your coolant" warning; the counter resets when cooldown
|
||
reaches idle.
|
||
|
||
A clean check from the fault state logs a recovery.
|
||
|
||
### What the verdicts do
|
||
|
||
| Verdict | Effect |
|
||
|---|---|
|
||
| `OK` | Fire permitted. |
|
||
| `SUSPECT` | Hold requested, cut airflow held; auto-resumes on a clean re-check. |
|
||
| `FAULT` | Fire gated and the hold stands — for the operator to resolve. |
|
||
| `OVERTEMP` | Hold with forced cooling airflow; auto-resumes below the resume gate (§5). |
|
||
| `FIRE` | Motion stopped, latch locked, hold until the next run session (§7). |
|
||
|
||
Practical note: **expect a legitimate suspicion on the first checks after
|
||
manually stopping and starting the pump.** That is an airlock, the machinery
|
||
above absorbs it, and it clears on its own.
|
||
|
||
---
|
||
|
||
## 5. Over-temperature
|
||
|
||
The engine uses the factory's coolant windows:
|
||
|
||
- **Run ceiling 33 °C** — above this, the verdict goes `OVERTEMP` with a hold
|
||
request and cooling airflow forced on.
|
||
- **Resume gate 31 °C** — below this, recovery is signaled and the controller
|
||
resumes automatically.
|
||
|
||
The **upstream** sensor gates, because it reads the coolant actually entering
|
||
the tube.
|
||
|
||
What you see depends on what the machine was doing. A running cycle takes a
|
||
feed hold and resumes by itself once the loop recovers — your sender shows the
|
||
hold state and a warning message. A jog is canceled instead (a jog cannot be
|
||
held). Fire stays gated for the whole excursion.
|
||
|
||
---
|
||
|
||
## 6. Diagnostics: verifying and calibrating flow
|
||
|
||
The web panel's **Diagnostics** tab runs the two cooling tools. Both take the
|
||
hardware over: the active controller is suspended for the duration, the engine
|
||
stands aside, and the controller is restored on every exit path — completion,
|
||
error, or your pressing Abort. The laser stays latched throughout. Progress,
|
||
both coolant temperatures and a scrolling log stream to the page while it runs.
|
||
|
||
Both tools run at your *configured* duty, window and threshold, so the verdict
|
||
applies to the check the machine actually performs, and both use cut-profile
|
||
chassis fans — the condition the numbers were characterized under. Any
|
||
pump-off window aborts immediately if the downstream sensor passes 48 °C.
|
||
|
||
**Flow verify** (about 3 minutes) — one check with the pump running and one
|
||
with it commanded off.
|
||
|
||
- **PASS** = your threshold separates the two readings.
|
||
- Margins under 1.5 °C add a warning that you should re-calibrate.
|
||
- A failure here means the threshold no longer suits the loop, or the loop has
|
||
a real problem.
|
||
|
||
**Flow calibrate** (15–25 minutes) — three trials of each case, alternating,
|
||
with settle gates between them. It reports both bands and recommends a
|
||
threshold midway between the highest flowing reading and the lowest stagnant
|
||
one, with an **Apply** button that writes it to your settings.
|
||
|
||
- If the gap between the bands is under 3 °C it refuses to recommend anything
|
||
and tells you to raise the heater duty and rerun.
|
||
|
||
**When to calibrate:** after replacing coolant, after changing or servicing the
|
||
pump, if flow verify warns about thin margins, or if you see suspicions that
|
||
you can trace to nothing real. The shipped default suits the factory loop; a
|
||
rebuilt one may differ.
|
||
|
||
---
|
||
|
||
## 7. The fire watch
|
||
|
||
Alongside the flow work, the engine watches for evidence of things going wrong
|
||
at one-second resolution:
|
||
|
||
- **Emission evidence.** The kernel samples the *gated output* of the hardware
|
||
AND-gate — actual emission, not a commanded state. Emission seen with no
|
||
armed window in the recent past stops motion and locks the latch, and keeps
|
||
doing so while the evidence persists.
|
||
- **Laser power-good degradation** during an armed window is warned once per
|
||
session.
|
||
- **Stepper-driver faults** appearing during a run are warned, and HV current
|
||
is ranged for each job in the same log line.
|
||
- **Lid infrared channels** are polled every tick, and every job logs their
|
||
baseline and peaks.
|
||
|
||
**About the lid IR fire watch specifically:** it ships in *watch-only* mode and
|
||
logs rather than acts. The reason is honest and worth stating — those sensors
|
||
are, first of all, a photometer for the lid lamp. A full-power cut raises them
|
||
only a few counts above the level the lamp sets, a candle burning on the bed
|
||
raises them about the same amount, and anything that changes the lamp (a camera
|
||
snapshot, for instance) moves them by tens of counts. A fixed threshold would
|
||
therefore stop jobs for lighting changes while still missing a small flame. A
|
||
lamp-aware design is planned; until then the channels are recorded, not acted
|
||
on, and **the fire watch is not a fire alarm**. Never leave a running laser
|
||
unattended.
|
||
|
||
---
|
||
|
||
## 8. Settings
|
||
|
||
All of these live in the panel's Machine tab, are validated on entry, and can
|
||
only be changed while the machine is idle. The engine re-reads them at the
|
||
start of every run, so a change takes effect on your next job.
|
||
|
||
| Setting | Default | What it controls |
|
||
|---|---|---|
|
||
| `cool_flow_rise` | 14.4 °C | Downstream rise that counts as no-flow. Set this from **flow calibrate**. |
|
||
| `cool_flow_heater_pct` | 40 % | Heater duty during a check. Raising it separates the bands further at the cost of warming the loop more. |
|
||
| `cool_flow_check_s` | 50 s | Length of a check window. `0` disables flow verification entirely. |
|
||
| `cool_recheck_s` | 150 s | How often checks repeat during a job. |
|
||
| `cool_confirm_max_s` | 480 s | How long a suspicion may stay unresolved before it escalates to a fault. |
|
||
| `cool_temp_max` | 33 °C | Run ceiling — above it, hold. |
|
||
| `cool_temp_resume` | 31 °C | Resume gate — below it, continue. |
|
||
| `cool_cooldown_s` | 15 s | Smoke-clear phase at run duty after a job. |
|
||
| `cool_cooldown_max_s` | 300 s | Cap on the thermal cooldown phase. |
|
||
|
||
Two settings are deliberately not on the panel:
|
||
|
||
- `cool_fire_ir_delta` — the lid-IR fire gate (§7). It is `0`, watch-only, and
|
||
changing it by hand is not recommended until the watch is lamp-aware.
|
||
- `GFCOOL_*` environment overrides exist for bench work; they win for the
|
||
lifetime of the process and are not a normal operating path.
|
||
|
||
---
|
||
|
||
## 9. Not implemented yet
|
||
|
||
Stated plainly so nobody counts on them:
|
||
|
||
- **Low-temperature gates and warm-up.** The factory holds a job and warms the
|
||
coolant when the loop is below roughly 16 °C, and refuses to fire at all near
|
||
freezing. ForgeFIRM does not yet; a cold-room machine will start cutting at a
|
||
temperature the factory would have waited out. Two settings — a hard floor
|
||
and a warm-up gate — are planned.
|
||
- **TEC control.** ForgeFIRM never drives the thermoelectric cooler. Presence
|
||
cannot be detected (the output has no readback), so this will become a user
|
||
setting plus a simple hysteresis around the factory's setpoints.
|
||
- **A fire watch that acts** (§7).
|
||
|
||
---
|
||
|
||
## 10. Quick reference: what the machine does when
|
||
|
||
| Situation | Machine response |
|
||
|---|---|
|
||
| Idle | Pump on, purge air on, fans at idle, heater off, TEC off. |
|
||
| Job starts (or the laser arms) | Cut airflow, flow check requested once the loop is settled. |
|
||
| Flow check over limit, first time | `SUSPECT`: warning, hold, immediate re-check. |
|
||
| Second consecutive over limit | `FAULT`: fire gated, hold stands until you resolve it. |
|
||
| Suspicion unresolved past the budget | Escalates to `FAULT`. |
|
||
| Three cleared suspicions in one job | Aggregated "check your coolant" warning. |
|
||
| Upstream coolant above 33 °C | `OVERTEMP`: hold + forced cooling; auto-resume under 31 °C. |
|
||
| Job ends | 15 s smoke clear at run duty, then reduced airflow until the loop is under the resume gate. |
|
||
| Controller stops reporting | Fire blocked at once, stand-down through cooldown. |
|
||
| Silence while armed, or a program still playing | Motion stopped and the latch locked by the engine itself. |
|
||
| Verdict file missing or stale | The controller treats it as fire-blocked and holds. |
|
||
| Diagnostic running | Engine suspends its writes and publishes fire-blocked. |
|
||
| Engine gone while armed | Controller writes factory run duties once, holds, stands down. |
|
||
|
||
---
|
||
|
||
## See also
|
||
|
||
- [Motion and laser drive](MOTION.md) — arming, job phases, both controller modes.
|
||
- [Laser safety](SAFETY.md) — the hardware chain the beam actually passes through.
|
||
- [LightBurn setup & operation](LIGHTBURN.md) — `M8`/`M9` and air assist in practice.
|
||
- `forgectrl/docs/SERVICES.md` — the machine-services contract, including the
|
||
report and verdict channels in full.
|