ScottW514 5c282ce167 Add the senderchg and overrun bench drills; close BRINGUP item 20
Two live-fire drills in live_fire_drills.py: senderchg drops the sender
mid-line with the tube lit, reconnects and expects the next laser-on to
prompt again; overrun writes a 93-line fill at once into a running job
and expects the report, the alarm, the disarm and a fresh prompt after
$X. Both read hv_current and the thermopile for the instant emission
ends and open their "nothing lit" window 2.5 s after the event, since
laser_on_sampled is a one-second window count. Both passed on image
20260829190323; CAMPAIGN-LOG records the runs.

BRINGUP item 20 (the arm skipped on a stale spindle state) closes: fix on
the image, host and bench proven, covers in place. Its text moves to the
superseded notes; items 21 to 23 are now 20 to 22.

No catalog consequence: bench drills and documentation.