Files
forgefirm/meta-forgefirm/recipes-forgefirm
ScottW514 4a95595afd Pin forgectrl on the gate that waits for the enclosure; add its test
forgectrl now holds the motion check while a lid or the interlock is
open instead of starting the controller unverified: GET /mode reports
controller "waiting" with why, the button blinks amber, and the check
runs when the enclosure closes. motion.gate-waits-for-lid drives the
fixture's lid channel: the lid opens, forgectrl restarts, /mode must
read waiting with why naming the lid, no pid, motion unverified, the
button amber (sampled over a blink period: the smooth trigger's target
reads 0 through the off half) and no probe line in the log; the lid
closes, and the controller must come up verified with MOTION OK on the
first probe.

Proven on the bench reference: PASS, the controller verified 6.5 s
after the lid closed.
2026-09-09 11:03:33 -04:00
..
2026-09-08 17:06:34 -04:00
2026-09-08 16:21:37 -04:00