BRINGUP gains Next-work item 21, the kernel trim and what it still owes
(a GRBL job and the acceptance campaign); CAMPAIGN-LOG records the
2026-08-24 review, the trim, and the bench drill on dev 20260824164619
through the forced-panic read-back from pstore.
Docs only; no catalog consequence.
The first campaign with the bench actuator wired failed
motion.button-hold-resume on the tool, not the machine: the second press
was asked while the first 200 ms pulse was still on, the fixture answered
409, the runner handed the step to an operator who was not in the room,
and the post pass could not jog a controller left in Hold.
- fixture.py: a press waits for the last pulse to end (the fixture's
pulse_ms) plus a 300 ms release, so the controller sees the edge; a
409 for a pulse in progress is waited out against button_pulsing and
retried once.
- runner.py: in an unattended run a fixture refusal ends the test at
once as ERROR naming the refusal; the operator fallback stays for
attended runs.
- baseline.py: a controller in Hold or Door gets a soft reset before the
return jog, position kept.
- tests: the fake fixture refuses a press while one is in progress and
reports button_pulsing; FakeGrbl records ^X and can land a reset in a
chosen state; five new tests.
- docs: ACCEPTANCE.md fixture rules, fixture/README.md tool's side.
No catalog consequence: tool-side change, no covers map moves.
Bench: campaign c-20260824174545-0bdc 25/25 with every action by the
fixture; the hold reset proven by a dry drill.
The acceptance page is assembled by page.py from forgetest/forgetest/ui/
(index.html, page.css, help.js, app.js) plus theme.css and the vendored
Bootstrap files, which are byte for byte the ones forgectrl's panel
carries, so the two pages look like one product and share the light and
dark themes (same localStorage key). A plain file is read in a checkout;
on the dev image the recipe installs ui/ gzipped and page.py reads the
.gz sibling, inflating once at first request: the rootfs is raw ext4, so
bytes in the package are bytes on the image. The explanatory prose
(campaign rules, the queues, the campaign actions, the prerequisites
switch, the bench intro) is a "?" popover with a link into the
documentation site; operator steps, prompts, notices and the live-laser
acknowledgment stay in the page, and confirmLive() stays a blocking
dialog. The page's own rules hold: rows, prompt buttons and tool entries
are built once and updated in place, and the popovers sit on static
markup only, so no rebuild orphans one. On a phone the Run pane goes to
the top for the duration of a run.
scripts/check-ui-vendor.py compares the shared files against forgectrl
at its pinned revision (or a local checkout with --forgectrl); it runs
in forgetest-ci.yml, so the copies cannot drift.
Tests: test_page.py (the gzipped install assembles to the same bytes as
a checkout, one self-contained response, the token placeholder once, a
missing marker refused); test_server asserts the served page's
invariants; test_responsiveness keeps its rules with needles pointed at
the new files, its ASCII rule applied to our own sources (Bootstrap's
CSS carries an em dash of its own), and its self-contained rule testing
asset tags rather than the presence of https:// (the documentation links
are meant to be there). forgectrl.panel-serves gains two needles for the
panel's theme attribute and save bar. Proof: the unit suite, and the
page in Chrome against a fake catalog (both themes, popovers, the bench
tab, a full operator run with its prompt, abort).
forgectrl pinned at 9d1f6f2 (the panel on Bootstrap, one save bar, help
popovers, themes, the gzipped page); PV unchanged. The pin moves only
forgectrl's fingerprint. The forgetest changes are the harness's own and
have no catalog consequence.
The pin moves to forgectrl d97cb35: zero-based fragment timestamps and
the panel's clamped live-edge seek, the two faults MSE playback in a
real browser surfaced. CAMPAIGN-LOG carries the session record,
including the coexistence drill (a jog at commanded feed under both
live streams, underruns unmoved, planner buffer full). BRINGUP item 20
is down to one line: the full acceptance campaign on an image carrying
this pin.
The pin moves to forgectrl deee6a1: the render overlaps the previous
frame' copies and encodes behind an EGL fence, measured 13.8 fps
single-viewer at ~14 percent CPU and 9.8 fps with both stream types
served at once, luma bit-clean throughout. CAMPAIGN-LOG carries the
dated record; BRINGUP item 20 is down to MSE playback, the
coexistence drill, and the campaign.
The pin moves to forgectrl 2d59d78: the chroma passes point-sample
instead of box-averaging, taking the GPU render from 140 ms to 64 and
the stream to ~9 fps at ~7 percent CPU, with luma measured bit-clean
against the CPU path (which also retired the bottom-row artifact).
The CSI hardware frame skip is live-proven with the GPU path and is
the recommended low-CPU configuration. CAMPAIGN-LOG carries the dated
second-session record; BRINGUP item 20 now lists the render-encode
overlap as the path to 15 fps, then MSE playback, the CPU measure,
coexistence, and the campaign.
The pin moves to forgectrl 6614833: the five hardware corrections from
the GPU demosaic's first bench session (surfaceless EGL config, ARGB
render targets, GR88 raw import, the ipu_copy stride-fix crop between
the GPU and the CODA, the chroma mirror width). CAMPAIGN-LOG carries
the dated record of how each was found; BRINGUP item 20 now separates
what that session proved (the full GPU -> IPU -> VPU path serving
correct frames, H.264 as valid fragmented MP4 on hardware, texture
limits, slot fit) from what remains (the 140 ms render, the bottom
row, MSE playback, the CPU measurement, frame skip, coexistence, the
campaign).
The stream conversion now runs on the GC880 when the image carries the
GL stack, and /cam/h264 serves the same picture as fragmented MP4 in a
fraction of MJPEG's bytes (forgectrl 6573abd). This side supplies what
that needs and holds it to account:
- Distro: opengl stays a feature, with mesa trimmed to exactly the
path used (gallium etnaviv, GLES/EGL/GBM, no GLX, no display
platforms). Image: libegl-mesa, libgles2-mesa, libgbm,
mesa-megadriver. forgectrl dlopens them, so an image without them
still streams on NEON. Platform change: the next campaign is full.
- forgetest: camera.h264-stream exercises the endpoint end to end
(codec header, init segment, media fragments, /cam/status encoder
state) and accepts a clean 503 on a machine without the stack;
the camera covers name the new forgectrl files.
- VIDEO.md 5.6 now describes both streams and why H.264 earns its
place (the WiFi transmit path measures about 7 percent of the core
per MB/s sent); BRINGUP records the bench-validation checklist as
Next work item 20, including the release-size watch: mesa must fit
the 200 MiB slot gate.
fixture.py: the bench's /data/forgetest/fixture.json (hostname, key,
optional ip, the channels wired, arm_press), a resolver for
<hostname>.local asked of the network directly (the image has no mDNS
resolver), and the client. The runner probes it before every run and
at most every 30 s otherwise; ctx.act asks it for a channel it covers
and still waits for the machine's own reading, falling back to the
operator's notice when the box fails. A test declares with hands=(...)
what it asks of a person beyond its typed actions; an operator test
with none, whose actions the fixture covers, is routed into the
unattended queue, its Ready gates pass, and a prompt it raises anyway
is a FAIL naming the undeclared step. Live tests never move; their arm
press stays a person's unless the bench opted in, in which case the
fixture presses when the button lights. Whatever the box still holds
after a run is released before the baseline's post pass and recorded.
The page shows what the fixture covers. Contract in ACCEPTANCE.md; the
wiring facts, with the interlock connector left to the bench to settle
(SAFETY.md and the sister map differ), in BRINGUP.
Catalog unchanged in its definitions; the cloud and laser suites'
shared code moved, so their implementation hashes move with it.
The coverage lint already allowed docs, CI, unit tests and licenses to
go uncovered; the same list now keeps them out of every fingerprint,
so a README edit in any component re-requires nothing. The list moves
to the manifest module as NON_BEHAVIORAL, the one place both uses read
it. And a coverage entry that selects no file of its component (a glob
without the recipe's subdirectory, a component the manifest lacks, a
glob naming docs only) fails the lint: such an entry covers nothing and
the test's fingerprint ignores the file it meant. The contract says
both. Every test whose maps reached a doc or a test file gets a new
fingerprint once.
Dev image 20260823161333, campaign c-20260823161923-0dd7, 44 of 44,
release authorized. The cloud split of the acceptance plan is complete:
the protocol by the emulator with only the app to drive, the machine's
print behavior by the offline service, the two together by one real
print, and the service's hunt paid only where it is the subject.
A cloud client the tool starts for anything but homing comes up under
the /run/gfcloud-nohunt marker: the real client back after the
emulator, a mode the runner switches to or hands back, a controller it
restarts. The service keeps the head position it has. cloud.mode-switch
and cloud.service-protocol keep their hunts, and so does the one real
print: enter_cloud reuses a running session only when that client has
hunted the machine itself (session_hunted: never the emulator's, never
a no-hunt start), otherwise it restarts the client with the hunt, since
a print placed on a head position the service only believes can run the
gantry into a rail. The markers are one start, taken down by the client
that read them first thing; the tool's own removal stays for a start
that never happened. Catalog unchanged; the cloud tests' shared code
moved, so their implementation hashes move with it.
The service-protocol half of the cloud catalog on its own test: the cloud
client restarted as gfutilities' emulator under the /run/gfcloud-emulate
marker signs in, passes the firmware check, opens the WebSocket, answers
the connect-time hunt and the image requests with the dev image's canned
frames, and runs a print from the app through the real download path to
':completed' - nothing moves, nothing arms, and only the app has to be
driven, by a person or an agent through the prompt API. The real client
is restarted afterward and its hunt waited out. session_live now knows
the emulator's session is not the machine's, so enter_cloud restarts it
rather than reusing it; restart_client is the one restart the offline
and emulator entries share.
The dev image adds python3-gfutilities-emulator (the fixtures, packaged
on their own in meta-openglow); forgefirm-app moves to 12ad3b1 (gfcloud
--emulate). Catalog: 44 tests, 27 auto / 9 operator / 8 live; the new
test covers the gfutilities service layer and examples/, which step 4
will take off the other cloud tests. Replays over the prompt script;
contract and BRINGUP updated. A layer change (the dev image recipe):
everything re-requires on the next image.
Every offline test now removes the jobs it wrote under /tmp/forgetest
on its way out (the bench rule: nothing left behind in the session that
put it there). CAMPAIGN-LOG gets the 2026-08-22 entry for dev image
20260822232347: the offline service dry-checked, then campaign
c-20260822233344-08de, 13 run and 43 of 43 with the four offline tests in
5.5 minutes, and what the machine said under it. BRINGUP: the offline
service is done and bench-validated.
Four cloud tests no longer need the app, an account, a network, or
anything on the bed: cloud.lid-interlock-abort, lid-during-button-wait,
paused-lid-cancel and oversize-stream run under the offline service
(enter_offline restarts the cloud client with the /run marker for that
one start; Offline is the socket; offline_job writes the job). The jobs
come from forgetest/puls.py: the header of a factory print of this
machine type (134 tags, MCsn 0, so the client's limits and settings come
from where a service job's do) over a square traced at a steady feed
with a leading power byte of zero and no LASER bit anywhere - the arm
unlocks the latch, the beam is never commanded, so the tests stay live
and need no scrap. A job longer than the ring (33 MiB of ticks, an hour
of squares) is an 87 kB gzip written in a tenth of a second, in place of
a full-bed raster designed in the app.
session_live reads the offline mark as "no web session"; enter_cloud
restarts an offline client with the service, so cloud.pause-resume (the
one real print left, with cloud.mode-switch the service-protocol half of
the catalog) follows the offline tests without the operator's hand.
Replays over a fake socket; the contract and BRINGUP say how the cloud
catalog splits. Catalog consequence: the four re-ported tests move;
nothing else is invalidated.
CAMPAIGN-LOG: the 2026-08-22 entry for dev image 20260822204234 - the
three harness findings (the jog witness, the fading button LED, the
duplicated app cancel), the implementation-hash change they exposed,
and campaign c-20260822220701-a1c0: 43 of 43 from nothing, the 16
attended tests in 19 minutes, with what each new witness read on the
machine. BRINGUP: bench-validated, the latest campaign, the hash rule.
The implementation half of a domain fingerprint was the whole suite
file, so a two-line witness fix in laser.py re-required every laser
test and a rename in cloud.py every cloud test: sixty attended minutes
for changes that touched two test bodies. Now the hash is the test's
own function (its decorator included) together with the module's text
outside every @test function. A body edit moves that test alone; a
helper edit moves the tests of its module, which is what a helper does;
a file that defines no test in the @test form hashes whole. The gate
computes it the same way, from the same code.
Every recorded fingerprint moves once with this, so the next campaign is
a full one: the price of every later fix costing one test.
Also carries the re-targeted cloud replays that the previous commit
left in the working tree (the CI failure on 296fd68).
A campaign asked a person for about eighty things: lid, button and
interlock actions, app jobs, and sixteen confirmations by eye, most of
them as popups to read and answer while the head was already moving.
This is the forgetest-only step of cutting that down.
The operator channel. A test asks for its operator's part in four ways:
ctx.ready() pre-announces a timed step and waits for the click that
starts it; ctx.notice() is a standing instruction with no button, the
test watching the machine for the result; ctx.act(channel, state) is a
machine action by name (lid, interlock, button) - a notice for the
operator today, proven done by the switch reading or an `until`
condition, recorded in evidence.actions with who performed it, and the
seam a bench actuator plugs into through runner.fixture; ctx.confirm()
stays for the yes/no the evidence cannot answer. Tests declare
`actions`; a `precheck` refuses a start the machine cannot honor (a
reason, no result, a queue skips it and carries on).
The page shows what you will do before it is asked: the running test's
steps, a queue's attended tests still waiting, or the test whose title
you clicked while idle; notices and prompts sit under it. The campaign
card no longer carries baseline, queue and leftover notes: those go to
the runner journal (daemon.log, syslog as `forgetest`, and the run in
progress), with a Runner journal button in the footer.
The catalog, 43 tests (27 auto, 8 operator, 8 live; was 45: 25/12/8):
cloud.mode-switch absorbs cloud.hunt-lid-open and cloud.gfhome-homing
(the connect made with the lid open, the hunt judged lid-open with its
Z cycle, the re-hunt waited out after the close, the switch back, then
$H judged by gfhome's own "homing complete" line with its motion
windows; precheck homing_mode = gfcloud). kernel.fire-line is auto with
the HV-not-good precheck, camera.snapshot is auto (a second frame with
the lid lamp off differs and is smaller), motion.jog-roundtrip is auto
(the head accelerometer per leg, the supervisor's own witness). The
remaining attended tests use Ready gates and act(); the head's beam
detector and the button LEDs replace the eye, leaving two confirms: the
emission witness's mark and the app's display in cloud.pause-resume.
Proof: tests/test_operator.py (the channel, the precheck, the journal),
the cloud replays re-targeted to the merged round trip over a fake grbl
and the bench excerpts, 196 host tests green, coverage lint 0 uncovered.
Every re-ported attended test is owed one bench run on the next dev
image (BRINGUP). Catalog consequence: the merged and reclassified
tests' implementation hashes move; nothing else is invalidated.
Dev image 20260822182931 (forgectrl b27398a, python3-gfhardware e65cfc2):
every unattended test PASS. The record keeps what the instrumentation
said on the machine: the status temps with the SoC die, the run-end
range line with all three sensors, and the cloud client's first counted
gap line on a live hunt header (30 declared ignored, 49 undecided), so
the next decision on the undecided families starts from a number. Also
the stale-layer build that was stopped and rebuilt on the way.
forgectrl pin b27398a: the SoC die joins the watched board temperatures
(/status temps soc_c and the kernel's CPU cooling state soc_throttle,
the Status tab, the per-job range line naming a throttle), a throttle
starting or ending is logged, and the supply sensor stays a raw count by
decision (its heatsink cannot be reached with a thermometer while the
machine runs). forgefirm-app pin e65cfc2 (0.1.16+git): every pulse-header
key without an applier is declared with its reason or counted as
undecided in the job log, and CLOUD.md carries one disposition table for
the whole header.
BRINGUP: the pulse-header envelope item is closed. Its durable content is
in the facts bank ("The factory's envelope, decoded": the mandatory tags,
the empty tach windows, the factory's pause and fail tiers, the
per-sensor units, the unarmed flow controller, and ForgeFIRM's answer
with its catalog proofs) and in the "Deliberately not gated" paragraph,
which names every declared family. Item 19 is now the bench-measured
head crash and rail-contact detector; the fire-watch item holds the
header's lid IR thresholds as its prior. The facts bank also records the
SoC's own thermal guard (85 C passive, 90 C critical, no heatsink on the
factory board) and the board temperatures at idle.
Catalog: cooling.gate-off checks the die field, the unthrottled state at
idle and the widened run-end line (the unit fake mirrors it). COOLING
section 9 and the SERVICES verification status describe the present.
forgectrl pin 368fd0c: the critical-line cross-check binds only while the
ceiling is a gate. cooling.critical-tier pins that a POST setting the
ceiling to its off end is accepted with the default line (the unit fake
mirrors the exemption); CAMPAIGN-LOG records the gate-off failure on dev
image 20260822165832 that found it, and the critical-tier pass.
forgectrl pin 76115fd: the chassis LM75 and the supply sensor ride /status
as temps (degrees and a raw count), the engine ranges them over every run
session into one run-end line, and a critical fault that clears with its
session yields the reason to the standing hold.
Bench: critical_tier_drill.py (a bench tool now, registered as
critical-tier) sets the ceiling, the resume gate and the critical line a
few tenths above the live upstream reading and lets the engine's own
flow-check heater warm the loop through them inside one M8 session;
temp_calibrate.py gains supply-watch, supply-point and supply-fit for the
supply sensor against a thermometer on its heatsink, the fit shown beside
UAPI.md's unverified guess.
Catalog: cooling.gate-off checks the /status temps fields and the run-end
board-temperature line (the unit fake mirrors both, one new failure
case); cooling.critical-tier checks the reason after a faulted session.
Docs: CAMPAIGN-LOG entries for cooling.critical-tier on dev image
20260822154257 and the warm-loop drill (OVERTEMP at 10 s, CRITICAL at
14 s, the fault ending with the session); BRINGUP item 19, the facts bank
(board temperatures at idle), COOLING section 9, the bench README.
forgectrl pin a1875a8: cool_temp_critical_c (default 38 C) is the fail
tier above the coolant ceiling's pause: at or over it in a run session the
verdict is CRITICAL (fire blocked, hold, no resume this job), the fault
ends with the session, the settings API keeps it above the ceiling, and
its top turns the gate off.
Catalog: cooling.critical-tier (auto, 45 tests), driven through the
settings API like cooling.gate-off: a critical line at the ceiling is
refused (and undone should it ever be accepted); with the ceiling, the
resume gate and the critical line all under the coolant's temperature a
session reads CRITICAL rather than OVERTEMP with no resume and the reason
naming the tier and the coolant; after the session the ceiling alone
holds (OVERTEMP); with the critical line at its top the gate is off
(gates_off, the run-start log line) and the ceiling alone pauses;
restored, OK with nothing off. Four unit cases against a scripted engine.
_after_session takes the condition to wait for.
Docs: COOLING (verdict table, section 5, the settings table, the quick
reference), BRINGUP item 19 and the catalog count, the CAMPAIGN-LOG
paragraph for the fan-fault session rule on dev image 20260822145201.
The dated record of dev image 20260822135848: the campaign of every
non-operator, non-live test at 18 of 18 PASS with the measured floors and
the operating-point rule (cooling.fan-gate-trips and the hunt leg of
cloud.mode-switch as recorded), and the unplugged-exhaust-fan drill:
AIRFLOW at the grace plus three ticks with the exhaust dead, the other
fans held, the reason relayed on the Grbl port, the replugged fan ok
inside the next session's grace.
The drill showed the fault riding into idle, where the hold canceled
jogs and would have refused the cloud print that re-proves the fan.
forgectrl pin d51dbdb: the fault ends with its run session, and the next
session judges every fan afresh. cooling.fan-gate-trips checks the
verdict is OK with no hold once the tripped session is over (the unit
fake mirrors it); its covers, and the cooling tests' shared covers, gain
src/coolfmt.* (the tree manifest carries the new files at the bumped pin,
and the lint was right to ask). cloud.mode-switch samples the hunt's gate
rows twice a second: a hunt's run phase is a few seconds long.
Docs: COOLING 3a, BRINGUP item 19, CAMPAIGN-LOG.
forgectrl pin 47e4256: the airflow floors set from the bench measurement
(exhaust 6400, intake 2290, air assist 6000 rpm, purge current 300, grace
15 s) and the operating-point rule: a fan is judged while the laser is
armed, when a job's profile may raise it but never lower it below the run
duty, or whenever it is commanded at the run duty; the service's hunts,
sent with the extraction fans off, are measured and published unjudged.
Catalog: cloud.mode-switch now waits out the connect-time hunt sampling
/cool/status and requires no AIRFLOW, the exhaust row unjudged and the
exhaust actually off; its covers gain forgectrl src/cool.* and
src/airflow.*. cooling.fan-gate-trips uses an 8 s test grace (the
intakes take 7 s to 90 percent and tripped under the old 2 s at the new
floor) and its off leg waits for the row state as well as gates_off.
fan_floor_measure.py names a reply that is not JSON and calls the purge
readings idle and run (the pump is always on).
Docs: COOLING 3a and the settings table, BRINGUP item 19 and a facts-bank
entry with the measured fan speeds, the bench README, and a CAMPAIGN-LOG
entry for the measurement, the two status-document finds, the hunt find
and the hot-deployed bench runs of both tests.
The acceptance catalog gains the test behind forgectrl 5a31d66: an
exhaust floor at the legal maximum must trip AIRFLOW after the grace and
three ticks (hold, fire blocked, no resume, the exhaust gate TRIPPED and
named in the reason); a purge current floor at the ADC rail must trip
the same way; an exhaust floor of zero must read off in gates_off and
trip nothing; restored, the next session must run OK with every fan at
or above its floor. Three host cases against a scripted engine that
models the grace and the readings. The covers map names src/airflow.*.
COOLING.md gains 3a (the airflow gates) and the five settings with their
ranges and bands; SERVICES.md the gate rule, the rows, the AIRFLOW
verdict and fan_gates; SAFETY.md names the floors among the verdict's
inputs; BRINGUP item 19 records the gates as in with provisional floors
and the catalog at 44. Pins: forgectrl 5a31d66, forgefirm-app 81027ff
(0.1.15+git); fetch-verified.
cloud.pause-resume passed on dev image 20260821220926 with the service's
hunt windows (10 to 50 C) ignored as looser and the print's window (33 C,
5 C floor, 116 rpm air-assist floor) matched. The test now quotes the
print's job-limits line rather than the session's first (a hunt's), and
keeps the engine line that carries the header beside the last one.
forgectrl pin moves to e0b41b3 (the "not stricter" notice once per value).
The pulse header's envelope now reaches the cooling engine: the cloud
client (python3-gfhardware c34faa1) derives the coolant window and the
fans' minimum speeds from the header and rides them on every report,
and the engine (forgectrl 57f6064) resolves each as the stricter of its
setting and the job's, never looser and never overruling an off gate.
cloud.pause-resume, which runs a real print, now also reads the client's
"job limits from the header:" line and the engine's "effective limits:"
line from the two logs; two host cases cover the failure paths. The
needle guard lists the engine's phrases as not the app's.
COOLING.md section 2 explains what a cloud job brings with it; BRINGUP
item 19 records the pass-through as landed. Pins: forgectrl 57f6064,
forgefirm-app c34faa1 (0.1.14+git); fetch-verified.
First bench run of the gate-settings pattern: PASS on dev image
20260821210903 after the harness fix in f274eb1; the entry records the
failed first attempt and why it was the test's fault. BRINGUP item 19
carries the bench result.
The acceptance catalog gains the test behind forgectrl 9e44fdc: the
coolant ceiling set just over its legal minimum must trip OVERTEMP with
a hold and fire blocked at the next run start; set to its top the engine
must skip the gate (verdict OK), report it in gates_off on /status and
/cool/status, and log the run-start line; the original values are
restored, on failure too, and proven restored. Five host cases against a
scripted engine. The cooling covers map now names the files that carry
gate state (gates, settings, status, the panel) and corrects a glob that
matched nothing: the GRBL cooling client is src/glowforge_cooling.c, not
src/gfcool*. The fake forgectrl serves /logs/tail and keeps blank form
values as "clear", which is what the daemon does with them.
Docs: COOLING.md section 8 carries each setting's legal range and
recommended band and a new 8a on turning a gate off; SAFETY.md names
what no setting can reach; ACCEPTANCE.md records that gates are
exercised through the settings API, never GFCOOL_* env overrides;
BRINGUP item 19 records the pattern as landed and the catalog is 43.
forgectrl pin moves to 9e44fdc; fetch-verified.
The full acceptance campaign on dev image 20260821181036, the first built on
the <recipe>-pin.inc layout, satisfied 42 of 42 and its export authorizes a
release, so the status header, the acceptance section and item 12 describe
that rather than a campaign still owed; the catalog count is 42, not 35.
CAMPAIGN-LOG records the completion. Item 7 stops listing the cloud work the
campaign closed (the oversize live print, the progress bar watched from the
app, packaged-path cloud boot, the lid flash), records the operator's
declines (SPKI pinning, emulator parity, the ten-event pause machine) and the
reasoned memory guards, and item 19 no longer lists MCsn and PDfm as
unchecked: the client refuses both, so seventeen mandatory tags are dropped,
not nineteen.
forgefirm-app pin moves to b82d379 (python3-gfhardware): CLOUD.md and three
present-tense comments, no behavior change. No catalog consequence beyond the
pin bump itself, which the manifest scopes to the component.
laser.pause-resume-lid-cancel failed on the bench with the head 14.925 mm
along the first leg after the lid cancel: the driver took every resume
from a feed hold as a new job start (the core restarts a held cycle
through Idle), so the cancel returned the head to the pause point and
said "returned to the job start" about it. The driver fix is in
grblHAL-glowforge; this is its proof and the record.
The null-sink lifecycle harness gains rule 9: a job paused and resumed by
the button, then cancelled by the lid, returns to where the job began
(reproduces the bench failure to the millimeter on the old driver,
X=13.088 instead of 0); and a job abandoned in a hold and soft-reset is
over, so the next job from that spot returns to that spot. The campaign
log carries the dated account.
No catalog consequence: the acceptance test measured exactly this and
stays as it is; the harness is the CI side of the same contract.
The cloud job tests enter cloud mode and stay there, by design, so a
queue (or an operator) that goes on to a motion test reaches it with
gfcloud as the controller and no grblHAL process to find:
motion.step-timing-under-load failed on exactly that, before it touched
the machine. Nothing in the runner put the machine into the mode a test
needed; the baseline only preserved the mode it found.
A test now declares `mode="grbl"` (or "cloud") in @test. The runner's pre
pass, after the leftovers are handled and before the preserved state is
captured, switches through POST /mode, waits for the supervisor to settle
(controller running, motion verified) and for the Grbl port to answer,
and fails the test with the reason when the mode cannot be established.
Capturing after the switch means the post pass keeps the mode the test
asked for, so the machine changes mode only where the next test asks for
it and never between tests of the same mode. The cloud job tests keep
managing their own entry (enter_cloud also waits for the service
session) and declare nothing.
Tagged: every motion.* test but the mode-agnostic liveness probe, the six
laser.* tests, cooling.fans-quiet-after-motion, cloud.mode-switch and
cloud.gfhome-homing (both start in GRBL mode). controller_pid() now says
what mode forgectrl reports when the process is missing. The page shows
the declared mode as a badge; the Grbl port probe moved to hw.
Proof: tests/test_mode.py (switch_mode against the fake forgectrl,
including a refused switch, a controller that never comes up and a port
that never opens; the runner end to end from cloud mode, from grbl mode,
an undeclared test, and a failed switch). 151 unit tests pass; the
coverage lint is clean. No catalog consequence beyond the suite modules'
own source hashes: the change is to how a test is started, not to what
it proves.
A campaign is mostly waiting for the next Start. The page now offers two
queues, and each takes every test of its kinds the campaign does not
already count as satisfied: Unattended for the auto tests, which need
nobody in the room, and Operator and live for the ones that need somebody
at the machine, since they prompt and they fire the laser. The buttons
say how many they would run and ask before starting; the live queue names
the tests that fire and takes the acknowledgment once, for all of them.
A queue runs one test at a time through the runner's single slot, in
prerequisite order. Registration order otherwise, so a run reads down the
page, but a prerequisite inside the queue always goes first. It stops on
the first result that is not a PASS: a FAIL closes the campaign, and
carrying on would only open a second one behind the operator's back. A
test the runner refuses to start is skipped with the reason on the page
and the rest carry on, which is what happens to an auto test waiting on an
operator one: run the attended queue, then the unattended one again.
The queue lives in the runner, not in the tab, so reloading the page or
closing it leaves the run alone. While one is up it holds the machine
between its tests as well as during them, so a single Start and the bench
tools are refused rather than cutting in. Stop the queue cancels what is
still waiting and lets the run in progress finish; Abort ends that one
too, and lands as the non-PASS that stops the queue. Every run a queue
starts records which one put it there.
Also moves the /state ETag test to the end of its class. It invalidates,
timestamps are whole seconds, and a PASS stamped in the same second as an
invalidate is deliberately not inheritable, so on a fast run it decided
the inheritance an earlier test was checking.
forgetest is a dev-only component and can never appear in a coverage map,
so this has no acceptance catalog consequence.
The work ran from 2026-08-18 to 2026-08-20 and is finished, so the plan it ran
from is retired the way plans are retired here: what is durable moved into the
documents that describe the present, and the dated record of how the result was
obtained lands here.
The entry keeps the parts that live nowhere else. That the campaign started
from a wrong belief and was corrected by the factory itself, which stages a job
into its ring in free-checked segments and then appends to it for as long as
the job lasts. That the proof was already on the machine, a 107 MB job played
through a 32 MiB ring in this board's own factory logs. The two defects the
building surfaced, a dry ring reporting success and a pause that could not
retrace on a streamed job. And what it cost to be sure: a decoder 41 times too
slow to keep a ring fed, which only showed itself against a real 53 MB job.
They were open because the service has never sent them and cannot be asked
to. That is not a reason to leave them open: the factory application says
what each one does, and it says all four are hand-offs to programs this
machine does not have. BRINGUP's cloud item now records the disposition
rather than the question.
Two tests already run a print end to end, and progress is a property of a
running print, so the checks go there rather than into a test of their own
that would cost the operator another job.
cloud.pause-resume takes the job that fits the ring: the client names the
length it is reporting against, and the operator is asked the question only a
person can answer, whether the bar actually moved.
cloud.oversize-stream takes the job that does not fit, which is where a moving
denominator would show: the kernel's program total grows all run long under a
live feed, and the test already samples it growing, so the check is that the
figure progress divides by is larger than that - the job, not the count the
ring had swallowed when the run started.
The forgetest replay plays a captured log from a build that predates the line,
so it carries the line where the current build emits it, as it already does
for the warm-up and the rest.
BRINGUP's cloud item now says a print reports itself again, and what is left
on it is a print watched from the app.
The campaign log gains the F1 entry: the question was which of three carriers
the factory uses for the progress bar, and the answer is that two of them
collapse into one. Progress rides an outbound WSS type:"progress" frame that is
itself the periodic settings report, every 30 s. The write-up lives in CLOUD.md;
the log records how it was gotten and what else the capture proved, including a
factory progress total that grew 256 KiB per interval because the factory
live-appends to its own ring.
BRINGUP's cloud item now lists F2 among the open work with the carrier settled,
so what is owed is emitting the frame against the feeder's job total rather
than the kernel byte counter.
Documentation only, no behavior change, so no acceptance-catalog consequence.
cloud.pause-resume runs a print end to end, which is exactly what the job
lifecycle needs to be seen: a non-zero hold before the first fire, a non-zero
rest after the park, and neither on the connect-time hunt in the same
session. Folding the checks in there costs the operator nothing, where a
test of its own would cost another print.
The forgetest replay noticed first: it plays a real captured log from a build
that predates those lines. Rather than editing what the machine said that
day, the replay carries the two lines where the current build emits them.
BRINGUP's cloud item now names what is actually open on the header keys, the
park and the two periods, and records that the pause constants were looked
for in the wrong place.
BRINGUP's cloud item said a print is capped by the ring and listed the two
gaps that closed when it stopped being. It now says what bounds a print
(memory, through pulse_reject_threshold_bytes) and what catches a feed that
wedges (progress against room, not ring depth), and it names the two new
cases that cannot be induced from the bench: a body past the memory guard,
because the service has no such job to send, and a wedged feed, because a
healthy machine will not stall on request.
forgectrl.settings-bounds gains a probe at the far end of the new byte
range, so the validator behind those keys is exercised rather than assumed.
kernel.backtrack-bounds plays a program, stops it, and holds the readback
to the bytes it played less the deceleration tail: a step past the boundary
has to be refused rather than quietly shortened, and the run at the boundary
has to play out and come back idle. Motors locked, latch locked, duty zero,
so nothing moves and nothing fires.
cloud.oversize-stream pauses and resumes the live-fed print it already has
running. That is the pause the kernel change makes possible, and it costs a
minute of a job that is on the bed either way.
BRINGUP's pause bullet, its ring facts and item 18 all said a ring under a
live feed has nothing left to back into. The gap the writer keeps clear says
otherwise; what is still open for GRBL mode is the bookkeeping above the
ring, not the kernel below it.
The ring and the device-tree pool that backs it are now the size the
factory firmware runs. Docs follow, and the hardware facts bank gains the
reserved-memory map: 511 MiB usable, 96 MiB reserved for DMA, ~454 MiB
left to Linux.
image.health reads the pool size and ring_mb back and fails if they
disagree, so a pool the parameter does not use cannot ship unnoticed, and
checks that free never exceeds the ring less its gap.
Next-work item 19 carried three open questions about the factory's
operating envelope. All three are answered now, so the item states the
policy instead of the guess.
A fan tach alert during a cut pauses the print, taking the same transition
a user pause takes, and two of the factory's three tach monitors cannot
fire at all: they treat a zero limit as unconfigured and the limits arrive
zero anyway. So a stalled extraction fan is caught by the temperature it
causes, not by its tachometer. Every temperature alert pauses as well, and
a critical fails the machine outright, which is a different state and not a
pause. The scale question behind the header's ceilings is answered by the
coolant family, which the factory carries twice, once in raw ADC counts
where the tag named min is the hot limit, and once in millidegrees. And the
factory does not verify coolant flow at all, so the cooling engine's flow
check is ahead of the factory rather than behind it.
The crash, tilt and beam-detect bullets gain the same grading: an alert
threshold that pauses and a separate abort threshold that aborts.
Also drops references to paths that resolve outside this repo, in both
documents and in two bench scripts, naming the artifact instead. In
CAMPAIGN-LOG that is a wording substitution only; no date, claim or
measurement changes.
Documentation only, so no acceptance catalog consequence.
The section describes two channels flowing opposite ways - the
controller's job-state reports and the engine's verdict - so "the report"
pointed at the wrong one directly under a lead that names the verdict.
MOTION said jogs, homing and hunts were all ungated. Jogs are:
gfsw_visible withholds the door signal while the core is idle, jogging or
homing, so a jog both starts and runs with the lid open. Homing is not.
With homing_mode = gfcloud - the only method that works today - $H hands
the cycle to a cloud homing session, and its move to the home corner is
an ordinary motion action taking the default lid_gated=True: refused with
the lid open, stopped on a lid edge mid-run. Only the lens/Z hunt inside
that session passes lid_gated=False, and that session is also the only
place a hunt happens in GRBL mode - there is no hunt outside one.
BRINGUP gains item 18: GRBL pause and resume should leave no gap in the
cut, the way the factory's does. The beam stops at the start of the hold
(disable_laser_during_hold, on by default), so the head travels the whole
deceleration dark and the resume restarts from a standstill where the
decel ended - an unburned length, then a dwell through the accel that M3
shows as a deeper spot. The kernel waypoint backtrack cloud mode uses is
refused with EPERM on a live-streamed ring, so the equivalent has to be
built above the ring, where grblHAL still holds the planned path the
kernel has already overwritten.
Two wording fixes: the cooling verdict is described as a report rather
than a file, and gfcloud homing as using the machine's builtin
credentials.
Documentation only - no behavior change, so no acceptance-catalog
consequence.
grblHAL-glowforge 03d70e0, pinned here, makes density the shipped model
and $35 the density floor at 10. Every analog session in the stream
harness now selects its model rather than inheriting it: without that the
flip would have quietly turned them into density runs and taken the
analog fallback's coverage with them. laser.power-floor carries the new
floor and its PWMSAR minimum, and its description no longer describes
$35 as a duty floor.
All ten stream sessions pass on the new defaults, with the analog duties
shifting exactly as the floor predicts - min_value 12, gradient 0.115 -
along with both C harnesses and the lifecycle harness.
Recorded in BRINGUP and the campaign log, including what the defaults
rest on and what they do not: the seven ladders ran at F300 and F100 at
constant power, so production feeds, M4 into corners and the raster path
remain unproven on hardware.
$35 = 10 under the density model is a density floor, not a duty floor. It
maps S onto 9.4-100 percent density, so a commanded 1 percent lands at
10.2 percent, just above the marking floor the earlier ladders measured.
A ladder reweighted to the bottom of the user scale - 1, 2, 5, 10, 20,
40, 70, 100 percent of S - marked on all eight rungs, with eight current
segments over a 42.0 s window against exactly 8 x 5.25, and segment means
climbing 136 to 968.
That meets the goal the ladders started from: a user's 1 percent is a
real visible mark rather than silence, and 100 percent is full power. It
took all three pieces - density so every level is real pulses, the
minimum pulse so they stay strikeable, the floor so the user's range sits
on the band that works.
dladder no longer tells the operator to re-run at other base periods to
choose one. The period cancels out of the low end, and what a failing
rung now indicates is a floor set too low.