Next-work item 19 carried three open questions about the factory's
operating envelope. All three are answered now, so the item states the
policy instead of the guess.
A fan tach alert during a cut pauses the print, taking the same transition
a user pause takes, and two of the factory's three tach monitors cannot
fire at all: they treat a zero limit as unconfigured and the limits arrive
zero anyway. So a stalled extraction fan is caught by the temperature it
causes, not by its tachometer. Every temperature alert pauses as well, and
a critical fails the machine outright, which is a different state and not a
pause. The scale question behind the header's ceilings is answered by the
coolant family, which the factory carries twice, once in raw ADC counts
where the tag named min is the hot limit, and once in millidegrees. And the
factory does not verify coolant flow at all, so the cooling engine's flow
check is ahead of the factory rather than behind it.
The crash, tilt and beam-detect bullets gain the same grading: an alert
threshold that pauses and a separate abort threshold that aborts.
Also drops references to paths that resolve outside this repo, in both
documents and in two bench scripts, naming the artifact instead. In
CAMPAIGN-LOG that is a wording substitution only; no date, claim or
measurement changes.
Documentation only, so no acceptance catalog consequence.
The shipped default changed, so the drill's precondition would have
refused to run on a stock machine - the one configuration it most needs
to be able to test. Only an explicit analog selection is a refusal now,
and the drill reports whether the model came from the config or the
driver default.
grblHAL-glowforge 03d70e0, pinned here, makes density the shipped model
and $35 the density floor at 10. Every analog session in the stream
harness now selects its model rather than inheriting it: without that the
flip would have quietly turned them into density runs and taken the
analog fallback's coverage with them. laser.power-floor carries the new
floor and its PWMSAR minimum, and its description no longer describes
$35 as a duty floor.
All ten stream sessions pass on the new defaults, with the analog duties
shifting exactly as the floor predicts - min_value 12, gradient 0.115 -
along with both C harnesses and the lifecycle harness.
Recorded in BRINGUP and the campaign log, including what the defaults
rest on and what they do not: the seven ladders ran at F300 and F100 at
constant power, so production feeds, M4 into corners and the raster path
remain unproven on hardware.
$35 = 10 under the density model is a density floor, not a duty floor. It
maps S onto 9.4-100 percent density, so a commanded 1 percent lands at
10.2 percent, just above the marking floor the earlier ladders measured.
A ladder reweighted to the bottom of the user scale - 1, 2, 5, 10, 20,
40, 70, 100 percent of S - marked on all eight rungs, with eight current
segments over a 42.0 s window against exactly 8 x 5.25, and segment means
climbing 136 to 968.
That meets the goal the ladders started from: a user's 1 percent is a
real visible mark rather than silence, and 100 percent is full power. It
took all three pieces - density so every level is real pulses, the
minimum pulse so they stay strikeable, the floor so the user's range sits
on the band that works.
dladder no longer tells the operator to re-run at other base periods to
choose one. The period cancels out of the low end, and what a failing
rung now indicates is a floor set too low.
The fifth ladder, the first with a minimum pulse, moved the floor down a
full rung: only 5 percent failed to mark, and 5 percent now strikes. The
trace carries eight current segments where the run before it had seven,
with fire beginning at 6.2 s exactly at rung 1 and the usual flat
saturated final segment anchoring the count from the other end.
That retracts what the previous entry concluded. Pulse length is not
irrelevant: 10 percent moved from no mark at F100, with three times the
dose per millimeter, to a mark at F300 at the same density, the only
change being its pulses growing from 36-71 us stubs to 106 us. The
matched-pairs argument was sound but drawn entirely from comparisons at
or above 20 percent density, where every pulse length in play was already
long enough - it generalized from the one regime where pulse length does
not bite. Above ~100 us dose governs; below it pulse length does; below
~36 us the supply does not strike. The factory's 100 us quantum sits on
that boundary.
dladder now reads laser_pulse_min_ticks and prints what is actually
emitted. Without that its table reports the pulse density alone would
give, which is wrong wherever the minimum applies - at min 6 the bottom
four rungs all emit 213 us and vary their rate instead, and the operator
reads that table to interpret the material.
Rule 15 in the stream harness holds both halves of the minimum
(grblHAL-glowforge f7e8c17, pinned here): no emitted burst falls below
laser_pulse_min_ticks, excepting one clipped by fire going off mid-burst,
and the levels too faint to fill a window still render their exact
average density. Checked against a run at minimum 1 so it cannot pass
vacuously - level 2 goes from 444 bursts of one tick to 147 of three at
the same density, and levels already above the minimum are unchanged.
Four bench ladders settle the base period at 20. The same six rungs
marked in all of them, and the matched pairs across periods separate the
variables: at identical pulse length, halving the density killed the
mark; at identical density, varying the pulse 3x changed nothing. Feed
does not move it either - 10 percent at F100 carries 44 percent more
energy per mm than 20 percent at F300, which marks, and still left
nothing. The low-end marking limit is average power, not dose per length
and not pulse length.
The F100 trace separates two failures that look alike on the material:
seven current segments for eight rungs, anchored by a flat saturated
final segment that can only be full density, put 5 percent at no
discharge at all and 10 percent at a full 15 seconds of current with no
mark. Only the first is ours, and the minimum pulse is the answer to it.
Also recorded: the factory's Precision Power 1 runs a 19.53 percent FIRE
duty cycle at full PWM duty, and its 1-100 scale maps onto density
18.9-79.5 percent, so its 1 percent is the bottom of the useful band
rather than 1 percent of the range. Under the density model $35 and $36
are that same control - a density floor and ceiling - which makes the
user-facing scale a settings choice rather than new code.
The trace is the per-rung witness: the laser-off G0 between rungs reads
0, so the runs of nonzero current count the rungs that struck and their
level tracks each rung's dose. Without it a run reports only a range,
and which rungs fired has to be read off the material alone.
Under the FIRE-bit dose model the duty is pinned at full and the level
is carried by how many ticks of each base period fire, so a rung's pulse
is density x period - and the base period is the one parameter the host
cannot settle. dladder walks 5 to 100 percent of dose on scrap at
constant power, printing what each rung actually emits: density, mean
on-ticks, and the pulse the tube sees in ticks and microseconds. Below
one tick per period the pulse stays one tick and whole periods are
skipped instead, which the table says outright rather than quoting a
sub-tick average.
Run it at 20, then 40, then 10 on the same material. At 20 percent dose
that is 107-142 us, 249-284 us and 36-71 us respectively, which brackets
the 100 us the factory never goes below. The material answers two
questions: whether depth tracks density linearly, or the low end marks
harder than its share because every burst restarts the discharge and
carries the strike transient; and how short a burst still marks, which
is the floor a given base period can reach.
Preconditions are refusals, not warnings: laser_power_model must already
be density and $35 must be 0, since a floor lifts every rung off the
bottom of the range the drill exists to explore. The $35 message says a
runtime write is not enough - the S to duty mapping is precomputed when
the spindle is enabled. The drill writes laser_pulse_ticks itself when
it can reach the machine config, preserving every other line, and
refuses with instructions when run from a LAN host where it cannot.
Four new sessions in the stream harness cover the model (grblHAL-glowforge
2bca017, pinned here). Density renders the commanded level exactly -
levels 2, 3, 7, 15, 25 and 38 came back as 0.0158, 0.0237, 0.0551,
0.1182, 0.1969 and 0.2993 against level/127 of 0.01575, 0.02362, 0.05512,
0.11811, 0.19685 and 0.29921 - S1000 renders 1.0000 and still ends dark,
every power byte carries full duty, and a level change inside a run costs
no stream byte where analog ships one per level.
Rule 13 is the one worth having: the same job run under both models
produces an identical motion grid tick for tick, and all 20051 density
FIRE ticks fall inside the 169776 the analog run fired. The model masks
the core's fire state and never sources one, measured rather than argued.
Rule 14 covers the idle-gap fix: a standalone S between moves, from a
sender slow enough to drain the planner, now fires each move at its own
level (28338 ticks each at duties 30, 52 and 84). Before the fix duty 30
held all 85014 and the other two levels never appeared. That closes
"Next work" item 18, which this work opened earlier today.
The harness now derives its expectations from the board's floor and
chains two launches over one settings file, because the core precomputes
the S to duty mapping once when the spindle is enabled: $35 written at
runtime persists and reports immediately but only enters force at the
next controller start. That is recorded in BRINGUP beside the existing
defaults note, and laser.power-floor's failure message now says so.
Acceptance: the density path shipping off by default is inert until
laser_power_model is set, and the laser tests' covers already name
grblhal-glowforge src/**; the model's own acceptance test waits on the
bench drill that picks the base period.
The pthresh ladder on scrap puts the tube's two thresholds far apart: the
discharge strikes between 2 and 3 percent duty, but nothing lases usefully
below 16 percent (PWMSAR 20), and the rungs between show only a spot at
each line start. $35 ships at 16 (grblhal-glowforge 9466f76, pinned here).
The drill said current lift-off and first mark share a rung; this run
falsifies that, so its docstring and read-the-material text now name both
thresholds and warn that a start-of-line spot is below the threshold, not
at it.
A start-of-line spot is also what a full-power leak at a kernel run start
would look like, so laser_stream_test gains a ladder session (rule 10):
every FIRE tick must ride a commanded duty, and the fire ticks must divide
evenly across rungs. Both hold exactly - six commanded duties, no others,
and 28296 fire ticks on every rung - so the spots are the tube, not the
stream. The harness now derives its expectations from the floor, which
moves the M4 session's S500 plateau from 63 to 73.
laser.power-floor is a new auto acceptance test, the suite's only
non-firing one: a machine must actually carry the commissioned floor,
since stored settings beat freshly baked defaults.
Three cloud cuts of one square at Precision Power 1, 100 and Full Power
show what the analog path is competing with: the power byte is pinned at
127 in all three, dose is FIRE-bit density on a fixed 7-tick period with
the on-count dithered between adjacent integers, and the power setting
never reaches the machine at all. Facts bank and item 17 carry the
numbers; CAMPAIGN-LOG carries both sessions.
Bump the grblHAL pin to the real-time producer change.
Add motion.step-timing-under-load: the catalog had nothing that
exercised step generation while userspace competed for the single core,
which is exactly the gap that let the condition go unnoticed - the ring
never runs dry, so cnc/underruns reads 0 through it. The test asserts
the producer and the shipper both hold SCHED_FIFO, then drives
2000 mm/min round trips against a deliberate nice-5 CPU hog and requires
the controller to report no clamped events.
Add the pthresh live-fire drill: a constant-power ladder from 2 % to
30 % of full on scrap. Because $35 is a percent of full duty and the
rungs are percents of $30 with $31 = 0, the lowest rung that marks reads
directly as the $35 value. It needs $35 = 0 for the run, or the floor
lifts every rung and hides the threshold.
Record both open items in BRINGUP. The laser one carries the finding
that the factory never uses duty as a power control - all five firing
jobs in the captured pulse files pin the power byte at 127 and modulate
dose by dithering the FIRE bit at 6.5-18.8 % density - so the captures
cannot supply a $35 default, and the duty to optical-power transfer
function of this supply has never been measured.
Catalog 34 -> 39. Every remaining bench drill of the lid/button parity work
is now a test, with drills that exercise the same path combined:
motion.lid-cancel-home also cancels from a hold - a job paused on the
button is ended by the lid, never resumed - so the
armed window and the hardware button latch stay in
agreement by construction.
motion.cancel-abort also asserts what a sender abort must NOT do: it
stops where it stopped and never returns home. The
return-to-start belongs to the lid policy alone.
motion.interlock-cancel-park (new) the interlock loop cancels like the lid,
and the lid opened during the return home does not
interrupt it.
motion.lid-policy-hold (new) the other policy: Door park, no cancel, no
return, and a cycle start finishes the move. The
setting is restored on the way out.
laser.pause-resume-live (new) the button pause/resume during a live cut:
emission stops, the latch stays UNLOCKED and the
armed window open (a pause is not a cancel), the
next press resumes and the job finishes.
cloud.interlock-abort-park (new) the same interlock/park pair in cloud mode.
cloud.pause-cancel-paths (new) the two non-finishing ends of a print, each
from the state the factory ends it in: paused on the
button then cancelled by the lid, and cancelled from
the app while running.
The shared cancel tail (reason reported, reset without an alarm, position
kept, head back at the job start with the KERNEL counters confirming it) is
now one helper, so every trigger is judged the same way.
scripts/bench/resume_dark_lead.py: samples LASER_ON, FIRE, HV_ENABLE, the
charge-pump watchdog, the button and the doors off the SoC pads at ~2 kHz
through /dev/mem, with motion dated from the kernel step counters, across a
pause and a resume. Levels are taken at idle and everything after is reported
as a change from that baseline, so no polarity assumption is baked in. Dry by
default, with --auto driving the pause and resume through ! / ~ for an
unattended rehearsal; --run live adds the dark lead between FIRE and LASER_ON,
in milliseconds and in millimeters at the job's feed.
Bench registry: argument specs can name a flag (--feed 600) instead of being
positional, and an optional argument with an empty default is left off the
command line entirely.
Host proof: 104 unit tests (20 in the cloud suite - the two new cloud tests
replay the machine's own lid-abort excerpt, with the interlock and the app
cancel substituted for the trigger, and fail for the right reasons), coverage
lint 0 uncovered across 39 tests.
laser_lifecycle_test.py: the button toggle (press = Hold, press = Run;
the arming press is not a pause), lid and interlock cancel mid-job with
the return to the job start and no alarm, and lid_policy=hold.
Acceptance catalog: motion.button-hold-resume, motion.lid-cancel-home
(operator: travel job, lid open -> cancel message, banner, no alarm,
autonomous return, Idle at the start), laser.lid-cancel-mid-fire (live:
emission stops in hardware, cancelled, returned, armed=false, latch
locked, hardware button latch SET). covers name the switch and laser
sources explicitly.
LIGHTBURN.md: what the lid, Stop and the button now do; SAFETY.md: the
door policy and the button as a software layer; BRINGUP.md: item 16
records the whole parity change (host-proven, bench validation pending)
and items 4/12 point at it.
laser_lifecycle_test drives the controller's button wait through the
file-backed switch source (GF_SWITCH_FILE): a press with the lid closed
arms and nothing arms before it; the lid or the interlock loop opening
during the wait cancels the job (reason reported, alarm 3, never armed).
Acceptance catalog: laser.arm-wait-lid (operator kind - no press is
given, so nothing can fire) starts a laser job, has the operator open
the lid at the white-button prompt, and checks the cancel message,
alarm 3, armed=false, the kernel latch locked, no emission, and Idle
after $X. covers names glowforge_laser.c, glowforge_switches.c and
glowforge_switch_map.h explicitly.
LIGHTBURN.md: opening the lid or the interlock loop while the button is
lit cancels the job; a press with the lid open never arms.
The remaining bench diagnostics run from forgetest's #bench tab. The
tools that also run from a LAN host share scripts/bench/gfbench.py:
GF_HOST names a remote machine (host mode, sysfs through ssh, Grbl and
forgectrl over the LAN); unset, the tool runs on the board itself
(local mode, sysfs directly, everything on 127.0.0.1), which is how the
page runs them - with GF_HOST=127.0.0.1, the panel token in GF_TOKEN
and their data files under <data>/bench/ (FORGETEST_BENCH_DATA). The
helper also reads a machine setting from forgectrl, or from the settings
file on the board while forgectrl is stopped.
Ported: pwm_sweep / pwm_hold (scope = a takeover; the latch relocked,
the write refused if FIRE or LASER_ON reads active), pwm_stream_test
(PASS/FAIL exit), flow_characterize, flow_recheck_char,
flow_warm_validate and flow_matrix (takeovers: forgectrl owns the
thermal hardware, so the page's takeover replaces the tools' own
controller stop/restart, whose command line predated the supervisor;
results and logs in the bench data directory), flow_sustained,
fan_test, temp_calibrate (dry; watch bounded in seconds; the threshold
and the coolant conversion from the shared code), flow_escalate_drill
(cool_confirm_max_s shortened through forgectrl's settings for the
drill and restored; the setting's minimum is the default budget), and
live_fire_drills (<drill> [S] [F], all six drills, host from GF_HOST,
token from the board). flow_matrix joins the registry. What stays
unported cannot run against the machine at all: the two null-sink CI
harnesses and the .puls decoder.
Runner: a scope tool runs inside the takeover wrapper; the bench
environment above is passed to every tool. Tests: test_bench_registry
(registry <-> scripts/bench consistency, every ported tool builds its
command line, every script compiles, gfbench host/local modes) and the
server test (scope tool takeover, the environment reaching the tool).
Local mode smoke-run on the bench (temp_calibrate watch, setting, token)
from /tmp, removed after.
No catalog consequence: bench tools are not image components (dev-only
forgetest); the acceptance catalog is unchanged.
The dev image installs the bench tools under /usr/share/forgetest/bench/,
so flow_matrix.py and flow_warm_validate.py invoke the board-side sampler
from there instead of a hand-copied /data/flow_sampler.py; the README
follows. Bench-tool path change only, no machine behavior involved.
A stdlib-only daemon on the dev image (HTTP :8090) that runs the acceptance
catalog against the machine from a self-contained page, keeps the append-only
result log under /data/forgetest, and exports the release artifact the gate
reads. Tests declare kind (auto / operator / live), hardware (api / takeover),
coverage globs, prerequisites, and core membership; a test's domain
fingerprint is the hash of the manifest files its globs select plus the
platform and its own implementation, so a PASS stays valid exactly while
nothing it covers changed. Campaign rules: a FAIL ends the campaign, the core
(image health, kernel latch and drills, one live emission witness) is never
inherited, invalidate-all forces a full campaign, no SKIP. Live tests need the
operator acknowledgment and the physical arm press through the controller;
takeover tests stop forgectrl for the duration with a crash-recoverable
marker; the tool never touches the laser latch.
Catalog v1: 24 tests ported from the proven bench drills with their recorded
pass criteria (image, kernel K1-K3 and fire A/B/U, forgectrl API and logs,
motion incl. dead-man, cooling, live laser, camera, update, cloud). The bench
tab lists every scripts/bench tool and runs the board-side ones as
subprocesses (takeover tools wrapped). 44 host unit tests, including the gate
verification fixtures. Installed only by forgefirm-image-dev, with the bench
scripts under /usr/share/forgetest/bench.
rsyslog replaces busybox syslogd/klogd (VIRTUAL-RUNTIME_base-utils-syslog,
trimmed PACKAGECONFIG) and becomes the only log writer: the appended
/etc/rsyslog.conf sets the inputs and the ff_line format and includes
the per-logger rules that `forgectrl --render-syslog` renders from the
machine settings at boot. forgefirm-logrotate becomes forgefirm-logging:
render before rsyslog starts (S19), sweep the pre-syslog log files into
/data/forgefirm/legacy-logs once, and rotate the tree at boot and hourly
by rename + HUP instead of copytruncate. Pins bumped to the pushed
forgectrl (syslog emitter, Logs tab, export), grblHAL-glowforge (syslog
emitter) and python3-gfhardware apps (syslog handlers, capture dir);
the CI harnesses set FFLOG_STDERR=1 so failure diagnostics keep the
controller's log lines. BRINGUP carries the bench validation checklist
(Next work item 14); this is an image change and rides the next flash.
- platform_drills.py (on the board, forgectrl stopped): dead-man trip
readback, rmmod/modprobe with concurrent attr reads, decay/microstep
readback, LED sequence.
- live_fire_drills.py: ircut (S/F selectable characterization job),
expstop (armed job + POST /controller/stop, controller left stopped),
ctrlstart (separate, operator-approved resume); the token header is sent
in exact case.
- laser_lifecycle_test.py: sigterm-mid-job - SIGTERM during an armed job
must stop it, relock the latch and exit promptly.
The host-side coolant and fan tools call the ssh on PATH, or the client
named by GF_SSH (a wrapper such as a WSL distro's ssh), instead of a
fixed wrapper. The bench README lists every committed tool and data
file, and explains how the coolant-flow fire-gate threshold was
derived from the committed flow-matrix data and how to re-run that
derivation on another machine.
Pulls in the coarse-pacing fix for parked wait-for-operator states (a
machine left in Door or Hold no longer pins ~28% of the core), plus
P10's grblHAL CI/tests and the mlockall-root-only change. Fetch-verified.
Adds pacing_test.py (dry hold/resume + CPU measurement) and records the
diagnosis and bench validation in BRINGUP.
Phase 5 A-1 emission witness and A-5 HV telemetry pass on live burns;
A-2 lid-IR characterized as a weak signal at 40% (gate left watch-only);
pgood confirmed unusable as a witness on this PSU. Phase 4 X-3 (0.1s
job-based disarm on M2) and G-10 (disarm counts down in Hold) pass.
Adds live_fire_drills.py (arm-lifecycle sampler over TCP + HTTP).
gate_a_kernel_drills.py stages the three remaining GATE A kernel
drills (controlled-stop deceleration floor, resume waypoint with the
latch locked, mid-ramp latch unlock) with software witnesses and the
PSU-connector scope point. lid_ir_ambient_baseline.csv is the
fire-watch ambient anchor (600 samples, lid closed, machine idle);
BRINGUP records the baseline statistics and the idle verification of
the emission/fire/HV evidence plumbing.
Four sessions against the reported messages: arm once per job with
M5/M3 persistence and the M2 close (grace pushed beyond the horizon so
only the program-end path can disarm); a displaced sender must re-arm;
the disarm grace counts down in Hold; a blocking cooling verdict
refuses the arm. Test-the-test proven: a build with the job-based
window reverted fails at the first discriminating assertion. Wired
into the controller repo CI alongside the emission harness.
- Controllers stop at K80, before forgectrl at K90: runlevel 0/6 no
longer tears down the cooling engine, fire gates, and broker while a
controller may still be executing a job.
- The grblhal/gfcloud init scripts are real emergency levers: stop
routes through the supervisor (POST /controller/stop - a bare pkill
was safed and respawned seconds later), start resumes supervision,
status exists, and the pkill fallback matches full executable paths
instead of truncated names or bare substrings.
- slotmigrate: the partition grow gets the same 2048-sector tolerance
as the filesystem branch (an exact compare rewrote the MBR at S02 on
every boot on disks where the grow cannot land on the last sector),
verifies it made progress, and the resize2fs retry is bounded at
three attempts with the counter kept on p3 itself.
- Installer: archive product/platform are verified after the signature,
and a validly signed OLDER release now requires an explicit yes
instead of installing as a silent downgrade. All predictable /tmp
paths in the installer and ffboot are mktemp now.
- release.sh rejects multiple positional versions (the last one used to
win silently) and a release without factory-era verification dies
unless explicitly bypassed; mkfw.sh refuses to pack when the public
key for the post-sign self-check is missing.
- forgefirm-logrotate: size-capped rotation (boot + hourly) for the
/data logs - a full /data breaks settings, update staging, and the
controllers own writes.
- Bench build scripts derive every path from their own location or
FF_SRC_TOP/FF_BUILD_TOP and log to mktemp files.
- LIGHTBURN.md: mandatory "Before you cut" safety section; the
walkthrough now reflects the firing machine (dry runs need the
layer output off or M5; live first-cut instructions); the homing
entry documents homing_mode and the gfcloud method; the machine
address is a placeholder.
- README.md: condensed safety section linking the full text and the
regulatory notes.
- INSTALL.md: "Regulatory and legal" section ahead of the install
steps; routine updates route through the panel updater rather than
the installer.
- BRINGUP.md: the release signing key is described as held offline
(no on-disk path); bench address and credential notes removed;
Next-work item 7 corrected (the installer embeds the production
release key); status entry for audit remediation Phases 0-1; the
GATE A kernel drills join the pending image-flash checklist.
- bench scripts: the target host comes from GF_HOST (or argv) instead
of a hardcoded address.
- laser_stream_test.py: per-session controller runs with a hermetic
cooling-verdict publisher; new assertions that every stream
terminates with FIRE clear (including M3 held to stream end) and
that no FIRE bit rides a zero-step gap; a cycle-churn session
exercises the stop/start seams.
Audit findings D-1, D-2, D-3, D-5, D-10, D-12, B-10, and the harness
half of D-4/G-1.
BRINGUP item 2: grbl-mode laser software implemented + bench-verified
without fire (record in the gate list); first light pending.
LIGHTBURN.md: arming/button-press operation, S-max 1000, fire gates.
scripts/bench/laser_stream_test.py: host-side stream-dump contract
verification against the null-sink build.
flow_confirm_drill.py walks the driver's suspicion/confirmation state
machine through every verdict with real pump-off transients in one M8
session; flow_escalate_drill.py exercises the starved-re-check
escalation against a short GFCOOL_CONFIRM_MAX_S. BRINGUP records the
triage resolution (the 2026-08-03 faults were a real transient
stagnation, probable pump airlock - the check was right), the slug/
circulation measurements, and the new check semantics.
The head lis2hh12 (i2c-3 0x1e, direct-I2C at ~530 Hz - st_accel sysfs one-shots are ~6 Hz and the kernel has no IIO triggers) sees rail contact as a 20-40x jolt over the creep baseline within ~4 ms. bump_seek.py: 3/3 detected hits, zero false positives over ~180 mm of creep, jog-cancel stop and back-off. BRINGUP carries the full record and the driver integration design.
Sources live at github.com/ScottW514/forgectrl (history extracted, layout src/ + init/); the recipe pins SRCREV and installs the init script from the repo. Adds the build-forgectrl.sh bench cross-compile script.
Adds the design matrix and its supporting tools, and records in BRINGUP
what the 60-run matrix overturned: sub-40-percent duty mimics flow
(three of five dead-pump trials looked healthier than a working pump),
the operating point and threshold now rest on 25 pooled observations,
periodic re-checks are thermally free with the fans running, and the
settle gate closes a bench-proven miss. Also records what is NOT yet
validated - warm-loop baselines and behaviour under laser heating - as
first-light commissioning items.
Records why the temperature formula changed (and that everything
derived from the old one had to be re-derived), the flow
characterization data at both heater duties, the false negative that
killed the dT-threshold design, and the downstream-rise check that
replaced it. Adds flow_characterize.py to the bench kit.
The UAPI raw->Celsius formula is an explicitly unverified best guess and
every absolute coolant threshold inherits it. temp_calibrate.py records
reference points (measured temperature paired with averaged raw ADC
readings) and least-squares fits the real line per sensor, printing it
against the guess with a difference table. Modes: watch / point / fit.
BRINGUP records the gate as complete with tach-verified results;
LIGHTBURN.md documents the per-layer Air Assist toggle driving the
cut-profile ventilation; fan_test.py joins the bench kit.
Scope on GPIO2_IO30 (the SoC FIRE drive): two 2.000 s FIRE windows,
the second terminated only by the SDMA end-of-data backstop. Measured
2.0000 s exactly with clean edges on BOTH termination paths - normal
completion and true underrun (streaming=1, kernel underrun state
reached and acked; fire_test.py gains the U mode). The backstop drops
FIRE within one tick regardless of how the stream dies.
With the waveform, stream-path, latch, topology, and interlock-
semantics results from earlier today, every standing hardware
verification gate for live fire is now passed; what remains is the
laser-milestone software and a chain-armed first-light procedure.
fire_test.py phases A/B with the scope on the PSU LASER_ON pin, power
byte 0 throughout, HV unpowered, operator-executed unlock: latch LOCKED
severs FIRE entirely (pin flat + kernel laser_enable 0 under 40k
streamed fire bits); latch unlocked with the chain unarmed shows FIRE
live kernel-side while the PSU pin stays flat - the factory board
gates LASER_ON behind OK_2_FIRE exactly like the OpenGlow AND design.
interlock_circuit semantics pinned by the 13-to-7 transition: b0
LASER_ON monitor active low, b1 FIRE active high, b3 latch 1=locked.
The 1-tick FIRE drop measurement is deferred (SoC net inaccessible;
PSU pin needs an armed chain) - documented with both closure paths.
Power-bytes-only program played by the pulse engine with the scope on
LASER_PWM: full duty staircase observed, run-start 100 percent duty
reset confirmed on the pin, consecutive-power-byte drop confirmed
(second byte of a back-to-back pair discarded), and duty persists
after end-of-data - the laser-off guarantee rests entirely on FIRE.
Zero motion (motor_lock=15 + no step bytes; position counters pinned)
and the laser chain silent throughout. Adds pwm_stream_test.py to the
bench kit and records the FIRE/OK_2_FIRE/LASER_ON/HV_EN naming from
the OpenGlow LASER SAFING sheet.
Direct PWMSAR duty steps with the machine in the locked state
(controller stopped, cnc disabled so steppers are unpowered, laser
latch locked, lid closed; laser_on_sampled stayed 0 throughout).
Measured on the pin: 25.0 us period / 40 kHz stable across the full
duty range; 50/25/75 percent confirmed visually; low end
cursor-measured 6.4 vs 6.3 percent commanded (PWMSAR=8), clean pulse.
Matches the register-level audit numbers (divider 13 x 127 counts).
Adds pwm_sweep.py / pwm_hold.py to the bench kit and records the two
remaining pre-live-fire gates (1-tick laser drop at underrun via the
stream path with FIRE observable under a locked latch; interlock
readback semantics) in BRINGUP.
The step backend now lives in github.com/ScottW514/grblHAL-glowforge
(grblHAL driver convention: core submodule, driver.c HAL, board header).
Add build-glowforge.sh, update the BRINGUP runbook (no -t throttle,
EEPROM path, kill-before-scp, producer stats line, reset/disconnect
semantics), and teach bench_m2.py to parse the F: status field (no
spindle registered = no FS: field). Settings-write crash fix is
upstream as grblHAL/core PR 999.
Extract the factory motion profile from the _RESOURCES pulse streams
(new puls_profile.py): 700/590 mm/s2 X/Y accel on v2.6.0 firmware,
202 mm/s travel peak at the 28160 Hz travel tick, PIC currents X 135/33
and Y 22/5 run/hold, decay mode 1. Add the bench_m2.py round-trip jog +
feed-hold suite (all green 2026-08-02: sustained 200 mm/s, exact
returns, clean hold/resume, zero underruns) and update BRINGUP.md:
board moved to a fixed lease at 172.16.1.97, analog config now applied
by the sink itself, $RST=$ note for stale stored settings.
BRINGUP.md is the cold-start reference: project status (audit phases
0-5 complete, Phase 6 spike achieved - first grblHAL-commanded motion
2026-07-26), bench/board access, build+deploy procedures, the step
backend runbook incl. the required analog machine config, the measured
hardware facts bank, and the ordered next-work list. scripts/bench/
preserves the hardware-verification tools (underrun feeder, end-of-
data protocol bench, PWM register check, cross-build scripts).