CAMPAIGN-LOG: the attended set stopped at its first test

The record of the live-fire failure on 2026-09-03: a job fired for about a
second with idle airflow under a warm-up hold that arrived one tick later,
the leftover start-gate setting behind it, the engine's arm-time gate gap it
exposed, and what is owed before any further live fire.
This commit is contained in:
ScottW514
2026-09-02 21:59:31 -04:00
parent ec9e9860c9
commit aa0d86635c
+27
View File
@@ -7627,6 +7627,33 @@ Owed: the attended eleven (live fire, the operator, one run per turn):
`cloud.oversize-stream`, `cloud.paused-lid-cancel`; then the push in CI
order and the pin bumps.
## 2026-09-03: the attended set stopped at its first test
The operator rebooted the machine before the attended set, because the
interrupted cloud test had left the fans running, then started
`laser.emission-witness`. The fixture pressed at 01:52:46; the job started
and, one engine tick later, the engine declared a warm-up hold (coolant
22.9 C under a 24 C start gate) with the heater on and idle airflow.
grblHAL honored the hold and feed-held the job. So the laser fired and the
head moved for about a second with the fans at idle duty, then the job sat
in the hold; when the warm-up and the flow verification ended, the run
airflow came up and the job waited for the button. The operator stopped the
session there; the test was aborted, the latch relocked, the machine left
idle, disarmed and locked.
Two causes. The 24 C start gate was `cool_temp_start = 23.9`, a setting
`cloud.verdict-hold` raises to force its hold and restores afterward: the
run the forgetest restart killed never restored it, and the next run
captured 23.9 as the original and restored it to 23.9. The setting is
stored and survives a reboot, and it is still in force. The second cause
is the engine's own: after an arm, a job can fire for up to one tick before
the warm-up and flow gates are evaluated and the run airflow applied. The
raised start gate exposed it. Both are owed: the setting reset to its
default, and the engine evaluating fire and airflow at arm time, before
the first fire, which is a change to forgectrl and another image before
any further live fire. The attended eleven were not run; the campaign on
20260903011655 stands at 45 of 56.
## Reference notes