Record the calibrate tool's accepted run on image 20260829220329

CAMPAIGN-LOG: aa-offset-calibrate with its 3 s at 8 Hz sampling reads
16.2 counts with a spread of 4.5 over six edges, the value already
applied; the compensation's whole path stands on the bench. BRINGUP item
21 keeps only a second machine's value and the lit-tube toggling.

No catalog consequence: documentation.
This commit is contained in:
ScottW514
2026-08-29 18:16:07 -04:00
parent e32c86fb10
commit 9bfdba44c8
2 changed files with 13 additions and 3 deletions
+2 -3
View File
@@ -1477,9 +1477,8 @@ Open items only. Anything closed is in `CAMPAIGN-LOG.md`.
assist runs unless `cool_aa_offset_counts` carries the machine's value assist runs unless `cool_aa_offset_counts` carries the machine's value
(the `aa-offset-calibrate` diagnostic measures it, the panel's Apply (the `aa-offset-calibrate` diagnostic measures it, the panel's Apply
writes it; zero is the factory's uncorrected reading; the bench writes it; zero is the factory's uncorrected reading; the bench
machine carries 16). Owed: the calibrate tool's recommendation machine carries 16). Owed: a second machine's value when one is on
accepted on an image (its first sampling refused its own result), a the bench; and the mid-run
second machine's value when one is on the bench; and the mid-run
toggling between two levels (0.6 to 1.1 C, both sensors together), toggling between two levels (0.6 to 1.1 C, both sensors together),
which comes only with the tube lit: not with the fans alone, not under which comes only with the tube lit: not with the fans alone, not under
motion, not in an armed dark window. The HV supply's input current on motion, not in an armed dark window. The HV supply's input current on
+11
View File
@@ -4524,6 +4524,17 @@ left `cool_flow_check_s` at 0 (the script's restore posted an empty value
and got a 400; fixed); the setting was put back to 50 and the engine and got a 400; fixed); the setting was put back to 50 and the engine
re-read it at the next session. re-read it at the next session.
## 2026-08-29: the calibrate tool's recommendation, on image 20260829220329
forgectrl 42cdb71 (each edge read over 3 s at 8 Hz a side), image
20260829220329 flashed by the operator. `aa-offset-calibrate` from the
panel's API, dark: six edges 15.5/16.1, -14.3/-14.2, 16.2/17.3,
-13.8/-14.8, 17.8/17.4, -18.1/-18.3 counts (down/up), mean 16.2, spread
4.5, recommendation 16.2, which is the value already applied. The
compensation's whole path stands on the bench: the tool measures the
machine's number, Apply writes it, and both coolant readings hold within
0.1 C when the run airflow comes on.