From 9bfdba44c8afde0e359261463c74cf617c0b9b67 Mon Sep 17 00:00:00 2001 From: ScottW514 Date: Sat, 29 Aug 2026 18:16:07 -0400 Subject: [PATCH] Record the calibrate tool's accepted run on image 20260829220329 CAMPAIGN-LOG: aa-offset-calibrate with its 3 s at 8 Hz sampling reads 16.2 counts with a spread of 4.5 over six edges, the value already applied; the compensation's whole path stands on the bench. BRINGUP item 21 keeps only a second machine's value and the lit-tube toggling. No catalog consequence: documentation. --- docs/BRINGUP.md | 5 ++--- docs/CAMPAIGN-LOG.md | 11 +++++++++++ 2 files changed, 13 insertions(+), 3 deletions(-) diff --git a/docs/BRINGUP.md b/docs/BRINGUP.md index 2af08da..ed5a519 100644 --- a/docs/BRINGUP.md +++ b/docs/BRINGUP.md @@ -1477,9 +1477,8 @@ Open items only. Anything closed is in `CAMPAIGN-LOG.md`. assist runs unless `cool_aa_offset_counts` carries the machine's value (the `aa-offset-calibrate` diagnostic measures it, the panel's Apply writes it; zero is the factory's uncorrected reading; the bench - machine carries 16). Owed: the calibrate tool's recommendation - accepted on an image (its first sampling refused its own result), a - second machine's value when one is on the bench; and the mid-run + machine carries 16). Owed: a second machine's value when one is on + the bench; and the mid-run toggling between two levels (0.6 to 1.1 C, both sensors together), which comes only with the tube lit: not with the fans alone, not under motion, not in an armed dark window. The HV supply's input current on diff --git a/docs/CAMPAIGN-LOG.md b/docs/CAMPAIGN-LOG.md index e1aa0b0..a626ca7 100644 --- a/docs/CAMPAIGN-LOG.md +++ b/docs/CAMPAIGN-LOG.md @@ -4524,6 +4524,17 @@ left `cool_flow_check_s` at 0 (the script's restore posted an empty value and got a 400; fixed); the setting was put back to 50 and the engine re-read it at the next session. +## 2026-08-29: the calibrate tool's recommendation, on image 20260829220329 + +forgectrl 42cdb71 (each edge read over 3 s at 8 Hz a side), image +20260829220329 flashed by the operator. `aa-offset-calibrate` from the +panel's API, dark: six edges 15.5/16.1, -14.3/-14.2, 16.2/17.3, +-13.8/-14.8, 17.8/17.4, -18.1/-18.3 counts (down/up), mean 16.2, spread +4.5, recommendation 16.2, which is the value already applied. The +compensation's whole path stands on the bench: the tool measures the +machine's number, Apply writes it, and both coolant readings hold within +0.1 C when the run airflow comes on. + ## Superseded status notes ### Shared machine services — remaining polish, as listed 2026-08-13