Record the calibrate tool's accepted run on image 20260829220329

CAMPAIGN-LOG: aa-offset-calibrate with its 3 s at 8 Hz sampling reads
16.2 counts with a spread of 4.5 over six edges, the value already
applied; the compensation's whole path stands on the bench. BRINGUP item
21 keeps only a second machine's value and the lit-tube toggling.

No catalog consequence: documentation.
This commit is contained in:
ScottW514
2026-08-29 18:16:07 -04:00
parent e32c86fb10
commit 9bfdba44c8
2 changed files with 13 additions and 3 deletions
+11
View File
@@ -4524,6 +4524,17 @@ left `cool_flow_check_s` at 0 (the script's restore posted an empty value
and got a 400; fixed); the setting was put back to 50 and the engine
re-read it at the next session.
## 2026-08-29: the calibrate tool's recommendation, on image 20260829220329
forgectrl 42cdb71 (each edge read over 3 s at 8 Hz a side), image
20260829220329 flashed by the operator. `aa-offset-calibrate` from the
panel's API, dark: six edges 15.5/16.1, -14.3/-14.2, 16.2/17.3,
-13.8/-14.8, 17.8/17.4, -18.1/-18.3 counts (down/up), mean 16.2, spread
4.5, recommendation 16.2, which is the value already applied. The
compensation's whole path stands on the bench: the tool measures the
machine's number, Apply writes it, and both coolant readings hold within
0.1 C when the run airflow comes on.
## Superseded status notes
### Shared machine services — remaining polish, as listed 2026-08-13