BRINGUP: bench session record - lid-IR gate sized, expected-stop lever defect found, fixed, re-proven
This commit is contained in:
+52
-9
@@ -249,6 +249,46 @@ FIRE drive — each with software witnesses (`laser_enable`, `laser_on`,
|
||||
`laser_on_sampled`, interlock bit 3) plus the PSU-connector LASER_ON
|
||||
scope point, run with forgectrl stopped so the pulse device is free.
|
||||
|
||||
**Bench session 2026-08-15 (image `20260815105250`, operator present) —
|
||||
two live-fire findings closed, one real defect found and fixed.**
|
||||
Lid-IR characterization at cutting power: three 30 mm squares on scrap
|
||||
(S1000 F300, S1000 F150, S800 F600); the engine's per-job telemetry read
|
||||
run-start baseline → peak `58/59/64/63 → 62/60/66/66`, `56/56/61/62 →
|
||||
60/61/66/68`, `56/55/61/63 → 61/60/65/66` — a worst normal-cut rise of
|
||||
**+6 counts** on any channel, against ±3 counts of ambient noise. Ambient
|
||||
that day read ~57–64 vs 37–40 on 08-14 (day-to-day drift ≈ +22 counts),
|
||||
which is why the gate keys off the run-start baseline and never off an
|
||||
absolute level. `cool_fire_ir_delta = 15` is the sized gate (≥ 2× the
|
||||
worst cut rise, at the ~15-count floor); it is a hand-edited
|
||||
`/data/forgefirm.conf` key and takes effect at the next run start. A
|
||||
flame-signature measurement (tea light in the closed bed, idle) was not
|
||||
made; the gate stands on the cut data alone until one is. **Armed kill on
|
||||
the expected-stop path — first run FAILED, defect fixed, re-run PASS.**
|
||||
With emission live, `POST /controller/stop` returned only after 5.30 s
|
||||
and the operator saw ~17 mm / ~5 s of continued cutting before a
|
||||
decelerated stop: the supervisor's SIGTERM was honored by the controller
|
||||
as "exit once motion is done" (`driver.c` exited only outside
|
||||
CYCLE/JOG/HOMING), so the job ran on until the 5 s SIGKILL escalation
|
||||
and the exit safing (`escalating to SIGKILL`, exit status 0x9). Fixed on
|
||||
both sides and bench-proven the same session: forgectrl `3edb7bd` writes
|
||||
`cnc/stop` + `cnc/laser_latch=1` **before** the SIGTERM (kernel-level,
|
||||
instantaneous, no-op when idle); grblHAL `5960f05` treats SIGINT/SIGTERM
|
||||
during motion as `^X` (controlled decel, latch relocked, alarm) and exits
|
||||
on the next pass, with the handler kept installed so the supervisor's
|
||||
second SIGTERM cannot hard-kill it mid-cleanup — CI case
|
||||
`sigterm-mid-job` (exit in 0.10 s; the old logic fails it). Re-run with
|
||||
the new binaries installed: POST returned in 0.46 s, `grbl controller
|
||||
exited (status 0x0)` with no SIGKILL, kernel `idle` and `armed:false` at
|
||||
the first post-stop sample, emission gone within the counter's ~1 s
|
||||
window; the operator saw ~1 s / a few mm of cut, then the stop. Also
|
||||
found and fixed: `auth.c` read `X-ForgeFIRM-Token`/`Host`/`Origin`/
|
||||
`Sec-Fetch-Site` case-sensitively (a title-casing client was refused);
|
||||
now `u_map_get_case`. Bench tooling for the session is committed
|
||||
(`scripts/bench/platform_drills.py`, `live_fire_drills.py` `ircut` /
|
||||
`expstop` / `ctrlstart`). Session rules, now standing: one live-laser run
|
||||
per turn with the operator's confirmation before the next; only
|
||||
observations, never inferences, in live-fire reporting.
|
||||
|
||||
**Phase 11 (licensing, legal, and documentation hygiene — the last
|
||||
phase) is code-complete and host-verified, 2026-08-15.** Licensing:
|
||||
`python3-gfhardware` declares the libdc1394 Bayer decoder it compiles
|
||||
@@ -2217,12 +2257,13 @@ accordingly ("Automatic — AP country, else World").
|
||||
emission witness, A-5 HV telemetry, X-3 job-based disarm, G-10
|
||||
grace-in-Hold, A-2 lid-IR first look). What has **not** been run on
|
||||
hardware, none of it gating, in rough priority order:
|
||||
- **Lid-IR fire characterization at cutting power** — ≥3
|
||||
representative jobs at real power, read the per-job baseline/peak
|
||||
log lines, set `cool_fire_ir_delta` well above the worst normal-cut
|
||||
peak (never below ~15 counts), keep watch-only until several jobs
|
||||
show no false trip, then enable the fire-abort gate. The 40 % cut
|
||||
moved the channels only ~+3 counts, so the gate ships 0.
|
||||
- ~~**Lid-IR fire characterization at cutting power**~~ — **DONE
|
||||
2026-08-15** (three cutting-power jobs, worst rise +6 counts,
|
||||
`cool_fire_ir_delta = 15` set by hand in `/data/forgefirm.conf`).
|
||||
Still open from it: watch the next several real jobs for a false
|
||||
trip before calling the gate proven, and measure an actual flame
|
||||
signature (a tea light in the closed bed, machine idle) so the 15
|
||||
is anchored on both sides.
|
||||
- **Kernel platform-hygiene batch (item 9), on the flashed image:**
|
||||
panic mid-motion with motors locked and the laser latched (motion
|
||||
stops, safety lines read safe); decay mode set/readback per axis;
|
||||
@@ -2235,9 +2276,11 @@ accordingly ("Automatic — AP country, else World").
|
||||
during `rmmod`.
|
||||
- **Dead-man collateral:** a kernel dead-man trip leaves the pump and
|
||||
airflow running (heat sources only go off); kill forgectrl during
|
||||
an update download (no pinned device, no EBUSY respawn storm);
|
||||
re-run the armed kill drill on the *expected*-stop path (mode
|
||||
switch / diag suspend) on the current image.
|
||||
an update download (no pinned device, no EBUSY respawn storm).
|
||||
~~Re-run the armed kill drill on the *expected*-stop path~~ —
|
||||
**DONE 2026-08-15**: it failed first (5 s of continued fire), the
|
||||
defect is fixed on both sides, and the re-run passed (see the
|
||||
session record above).
|
||||
- **Physical-evidence negatives:** force a head I²C error and confirm
|
||||
the witnesses report an error, not a plausible value; confirm a
|
||||
failed head capture leaves the measure laser off.
|
||||
|
||||