mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-27 16:51:12 -07:00
docs: TEC ships on Pro per published specs, not verified per unit
Basic/Plus share the passive closed-loop cooling and the 60-75 F window per Glowforge's tech specs and owners-forum consensus; the Pro's solid-state TEC buys 60-81 F. Spec-level only - tec_present stays a user setting regardless, since tec_on has no readback.
This commit is contained in:
+9
-5
@@ -785,12 +785,16 @@ chooses otherwise).
|
|||||||
reach the gate; that is honest, not a bug).
|
reach the gate; that is honest, not a bug).
|
||||||
- **TEC handling: PLANNED (laser-milestone scope,
|
- **TEC handling: PLANNED (laser-milestone scope,
|
||||||
operator-directed 2026-08-08).** The control board is common to
|
operator-directed 2026-08-08).** The control board is common to
|
||||||
Basic/Plus/Pro but the TEC itself is populated on Pro only, and
|
Basic/Plus/Pro; per Glowforge's published specs the TEC ships on
|
||||||
`thermal/tec_on` is a bare on/off output with NO readback —
|
the Pro (Basic/Plus: same passive closed-loop cooling, 60-75 °F
|
||||||
presence cannot be detected, so it is a user setting:
|
operating window; Pro: "solid-state thermoelectric cooler",
|
||||||
|
60-81 °F — owners-forum consensus matches), but that is a
|
||||||
|
spec-level claim, not teardown-verified per unit, and
|
||||||
|
rebuilt/revision units may vary. Moot for the design either
|
||||||
|
way: `thermal/tec_on` is a bare on/off output with NO readback —
|
||||||
|
presence cannot be detected — so it is a user setting:
|
||||||
`tec_present` (Machine tab, default off; ForgeFIRM never drives
|
`tec_present` (Machine tab, default off; ForgeFIRM never drives
|
||||||
tec_on unless set — on the bench Basic/Plus the line lands on an
|
tec_on unless set). The setting also covers retrofits. Operation when present: the factory
|
||||||
unpopulated position). Operation when present: the factory
|
|
||||||
regulates coolant toward its ~18 °C setpoints (CMet/CMdt
|
regulates coolant toward its ~18 °C setpoints (CMet/CMdt
|
||||||
18134/18364 mdeg — the same WTub/WTvb raw-754/751 pair that
|
18134/18364 mdeg — the same WTub/WTvb raw-754/751 pair that
|
||||||
proved the thermistor curve); plan is a simple hysteresis while
|
proved the thermistor curve); plan is a simple hysteresis while
|
||||||
|
|||||||
Reference in New Issue