diff --git a/docs/BRINGUP.md b/docs/BRINGUP.md index 8831559..c3d8b07 100644 --- a/docs/BRINGUP.md +++ b/docs/BRINGUP.md @@ -785,12 +785,16 @@ chooses otherwise). reach the gate; that is honest, not a bug). - **TEC handling: PLANNED (laser-milestone scope, operator-directed 2026-08-08).** The control board is common to - Basic/Plus/Pro but the TEC itself is populated on Pro only, and - `thermal/tec_on` is a bare on/off output with NO readback — - presence cannot be detected, so it is a user setting: + Basic/Plus/Pro; per Glowforge's published specs the TEC ships on + the Pro (Basic/Plus: same passive closed-loop cooling, 60-75 °F + operating window; Pro: "solid-state thermoelectric cooler", + 60-81 °F — owners-forum consensus matches), but that is a + spec-level claim, not teardown-verified per unit, and + rebuilt/revision units may vary. Moot for the design either + way: `thermal/tec_on` is a bare on/off output with NO readback — + presence cannot be detected — so it is a user setting: `tec_present` (Machine tab, default off; ForgeFIRM never drives - tec_on unless set — on the bench Basic/Plus the line lands on an - unpopulated position). Operation when present: the factory + tec_on unless set). The setting also covers retrofits. Operation when present: the factory regulates coolant toward its ~18 °C setpoints (CMet/CMdt 18134/18364 mdeg — the same WTub/WTvb raw-754/751 pair that proved the thermistor curve); plan is a simple hysteresis while