# CIRA tunnel watchdog LIVE on pfi-tacticalrmm (Prime go, 1232)
`[2026-10-03]` **CIRA tunnel watchdog LIVE on pfi-tacticalrmm (Prime go, 1232)** fixes MeshCentral "HW Connect stuck at Setup": after a power event AMT leaves its old tunnel half-open, and MeshCentral's relay picks it (3 of 3 episodes: esh-pve-2 twice, nh3-pve-2 once). A timer runs every minute and `ss -K`s any :4433 socket silent >180 s (healthy tunnels 6–30 s). Controls passed. → `services/cira-tunnel-watchdog/`. **Same day: nh3-pve-2's host moved to its X710 10G port** (`38:05:25:3b:a0:a8`, USW Pro 24 port 25 now native nh3-mgmt + tagged auto, reservation and DNS `nh3-pve-2.nh3.internal` = 10.100.250.62). ⚠ At 1233 its AMT (`:a6`, UDM port 5) had NO link, probably because the I226 port has no `auto` line now (MS-01 lesson, unconfirmed); flagged to Prime at 1235.