  • [2026-09-03] pfi-gx10 racked and networked: VLAN 50 via a DHCP RESERVATION, not a host static; Wi-Fi down.

pfi-gx10.nh3.internal10.100.50.60, wired only.

Operator ruling, and the better design: put the address on the switch/firewall side as a DHCP reservation and leave the host on DHCP. A host-side static works until the box moves, and then it is a stale netplan file on a machine whose address you no longer know. A reservation moves with the MAC.

UniFi switch port 22 native network  ->  nh3-servers (VLAN 50)
UniFi client reservation             ->  30:c5:99:3d:a7:45 = 10.100.50.60
host                                     unchanged, still DHCP

playbooks/gx10-rack-network.yaml was pre-written to apply a host static and was NOT used — annotated as retired at its top. Its safety ordering was followed and is still right.

The port arrived on the native VLAN, not the server VLAN — it DHCP'd 10.100.0.111 from nh3-default. The switch port had to be repointed before anything else could work. Do not assume a racked port is on the VLAN you asked for.

port_overrides is a WHOLE-ARRAY PUT. Anything omitted is deleted. Two unrelated overrides (ports 21, 23) were read, backed up to a file, preserved and written back.

The step that is easy to skip and expensive to miss: while Wi-Fi was still up, traffic from the box to nh3-dev preferred wlP9s9 — that interface sits directly on the userland subnet — so "I can reach it on the new address" proved NOTHING about the wired path. Downing Wi-Fi on that evidence is a coin flip on inter-VLAN routing, and losing it is a rack visit. Forcing the interface is what settled it:

ping -c3 -I enP7s7 10.100.10.50   0% loss   VLAN 50 -> VLAN 10
ping -c2 -I enP7s7 1.1.1.1        0% loss   egress

Only then did Wi-Fi come down, as its own step, /etc/netplan backed up to /etc/netplan.bak-preWifiDown. nmcli radio wifi off persists across reboot — verified by reading /var/lib/NetworkManager/NetworkManager.state back.

The box now has exactly ONE path. If that switch port or the reservation breaks it is a rack visit; the escape hatch is deliberately gone. Correct end state for a racked server, but a posture change from the desk setup — and this is the box run 3c moved to.

Runbook docs/runbooks/gx10-rack-network.md; commit a95717e.