vh 514ce7acc8 docs(esh): record the held DAC decision — forced 10G stays until the weekend cable swap
Operator is keeping the override rather than reverting: he has a replacement
cable and will run it at the weekend. Recorded as a held position so a later
session does not revert it as an oversight or re-run the diagnosis.

Also corrects a claim this runbook made an hour earlier. I wrote that the
zero-error 1G link ruled out a marginal cable. It did not — it only proved the
cable was clean at 1G. The two-hour soak shows errors climbing monotonically at
10G (200 to 221 rx, ~1 per 23 MB) plus one self-recovering link drop, so the
autoneg fallback had a real basis and the fix is the cable, not the config.
2026-09-04 10:52:58 -07:00
..