Dell R750xa JPJ1ZP3, 2x RTX 6000 Ada to be fitted, ComfyUI's new home at NH3. Diffing
Dell's factory CSV against the reseller invoice shows four downgrades: half the RAM, the
2400 W PSUs, and the GPU risers, cables and high-performance fans all absent.
Records the resolved GPU power chain, correcting my own first answer: the chassis' CPU
8-pin cabling is the right source type and NVIDIA 930-00030-1546-000 bridges it to the
card's 12VHPWR, so the PCIe-type RCCWC I first proposed is withdrawn. Also closes the NVMe
question — the backplane is SAS/SATA only — and notes that free PCIe slots may moot it.
Auto-archival fired at 308 lines; seven entries moved to archival-memory.md. The 250-line
target was not reached because the guards hold nearly everything else back as under 14 days
or carrying open deferred work.
Run 3c's new intended home is the GX10 rather than a power triage on ana-ml2: a ~240 W
appliance instead of the kilowatt-class box that tripped the breaker, and 121 GB unified
holds the 49 GB bf16 base comfortably where ana-ml2 was tight. The box is bare, so the
first move is a throughput probe rather than a harness port.
Also banked: the Ada migration settling on zfs send with branch (b) ruled out by irv-ml1
keeping its eight services; the Synapse 39-release upgrade with its one-way schema
migration, the appservice namespace opening and the admin API lockdown; the ratified room
alias convention; and a named failure class — a correct check aimed at the wrong object —
with six instances from one day across three sessions.
Single static page (nginx) fronted by Traefik at www.phasefinal.com, built
from the design brief. Site markup/CSS checked in verbatim from the design
session; fonts self-hosted (SIL OFL) with the @font-face block uncommented,
which every fresh export re-comments.
Routed via a Traefik file-provider config rather than the container labels:
the docker provider on ana-docker was not registering newly-created
containers, so the file router avoids restarting shared ingress. Labels are
retained in compose so the file can be dropped once that is fixed.