ScottW514 64f552fc28 laser power-good: the line characterized, the kernel-drill guard, the probe, the dev image's mmap and ctypes
The supply's power-good line is active high, static across HV enable and emission, and driven; the facts bank and CAMPAIGN-LOG carry the measurement and the item closes. The kernel-drill latch-unlock guard read the old inverted value as HV not good, a check that was vacuous and would refuse every run once the module reads the line correctly; it now uses the chain's own witnesses, the charge-pump watchdog and the engine state. pgood_probe.py watches the line beside the chain through the kernel readbacks and is registered on the bench page. The dev image lists python3-mmap and python3-ctypes again for the pad-level bench tools the python trim had left without them.