cooling.aa-offset-calibrate gives the tool 540 s (its 420 s stationary gate plus the six edges) and says so in its steps. Pin forgectrl 7dbb5e1e55a12e6bd1364d920f46c96a3ae2d4ce (the tool settles at the flow tools' gate before its first edge).
816 lines
45 KiB
Python
816 lines
45 KiB
Python
"""cooling.* - the cooling engine: flow verification through forgectrl's
|
|
diagnostics runner (the same check the fire gate runs), the fan profile
|
|
returning to idle after motion, the gate settings (a value inside the
|
|
legal range trips the gate, the far end of the range turns it off by
|
|
value, and both are said out loud: the settings reply, /status, the
|
|
engine's run-start log line), and the airflow gates (a fan under its
|
|
floor past the spin-up grace is a fault for the rest of the run)."""
|
|
import time
|
|
|
|
from ..catalog import test
|
|
from .. import hw
|
|
|
|
_COOL_COVERS = [("forgectrl", "src/cool.*"), ("forgectrl", "src/coolfmt.*"), ("forgectrl", "src/diag.*"),
|
|
("forgectrl", "src/gates.*"), ("forgectrl", "src/airflow.*"),
|
|
("forgectrl", "src/settings.*"),
|
|
("forgectrl", "src/status.*"), ("forgectrl", "src/ui/**"),
|
|
("grblhal-glowforge", "src/glowforge_cooling.*"),
|
|
("kernel-module-glowforge", "src/thermal*"),
|
|
("kernel-module-glowforge", "src/pic*")]
|
|
|
|
|
|
@test("cooling.flow-verify", title="Coolant flow check separates flow from no-flow",
|
|
subsystem="cooling", kind="auto", est_min=4,
|
|
covers=_COOL_COVERS, requires=["kernel.latch-locked-idle"],
|
|
steps=["Coolant loop normal (pump on); the machine idle. The controller is suspended by "
|
|
"forgectrl for the duration (about 3 minutes)."],
|
|
description="forgectrl's flow-verify diagnostic: one heater window with the pump on and "
|
|
"one with it commanded off, judged against the configured threshold. PASS = "
|
|
"the threshold separates the two readings with the margins forgectrl reports; "
|
|
"a thin margin is recorded as a warning.")
|
|
def flow_verify(ctx):
|
|
fc = ctx.forgectrl
|
|
ev = ctx.evidence
|
|
st, body = fc.get("/diag/status")
|
|
ctx.check(st == 200 and isinstance(body, dict), "GET /diag/status -> %s", st)
|
|
ctx.check(not body.get("running"), "a diagnostic is already running (%s)", body.get("tool"))
|
|
st, body = fc.post("/diag/flow-verify")
|
|
ctx.log("POST /diag/flow-verify -> %s %s", st, body if isinstance(body, dict) else "")
|
|
ctx.check(st == 202 and isinstance(body, dict) and body.get("started") is True,
|
|
"could not start flow-verify (%s %s)", st, body)
|
|
last_phase = None
|
|
result = None
|
|
t0 = time.time()
|
|
try:
|
|
while time.time() - t0 < 900:
|
|
ctx.checkpoint()
|
|
st, d = fc.get("/diag/status")
|
|
if st == 200 and isinstance(d, dict):
|
|
if d.get("phase") != last_phase:
|
|
last_phase = d.get("phase")
|
|
ctx.log("phase: %s (down %.1f C, up %.1f C)", last_phase, d.get("down_c", 0), d.get("up_c", 0))
|
|
if not d.get("running") and d.get("result") is not None:
|
|
result = d.get("result")
|
|
for line in d.get("log", [])[-12:]:
|
|
ctx.log(" diag: %s", line)
|
|
break
|
|
time.sleep(2)
|
|
except BaseException:
|
|
fc.post("/diag/abort")
|
|
raise
|
|
ctx.check(result is not None, "flow-verify did not finish within 15 minutes")
|
|
ev["result"] = result
|
|
ctx.check("error" not in result, "flow-verify error: %s", result.get("error"))
|
|
ctx.log("verdict: pass=%s threshold=%s flow_rise=%s noflow_rise=%s margins %s/%s thin=%s",
|
|
result.get("pass"), result.get("threshold"), result.get("flow_rise"),
|
|
result.get("noflow_rise"), result.get("margin_flow"), result.get("margin_noflow"),
|
|
result.get("thin_margin"))
|
|
ctx.check(result.get("pass") is True, "the threshold does not separate flow from no-flow: %s", result)
|
|
if result.get("thin_margin"):
|
|
ctx.log("WARNING: thin margin - run flow-calibrate")
|
|
ctx.check(fc.wait_idle(120, abort=ctx.aborted), "machine did not return to idle after the diagnostic")
|
|
|
|
|
|
AA_CAL_TIMEOUT_S = 540 # the tool's 420 s settle limit plus its six edges
|
|
|
|
|
|
@test("cooling.aa-offset-calibrate", title="The air-assist ground shift on the coolant readings measures cleanly",
|
|
subsystem="cooling", kind="auto", est_min=6,
|
|
covers=_COOL_COVERS, requires=["kernel.latch-locked-idle"],
|
|
steps=["Coolant loop normal (pump on); the machine idle. The controller is suspended by "
|
|
"forgectrl for the duration; the tool first waits for a stationary loop (up to "
|
|
"7 minutes after a heater trial), then the air assist cycles three times."],
|
|
description="forgectrl's aa-offset-calibrate diagnostic: the loop settled to the flow "
|
|
"tools' stationary gate, then the air-assist fan stepped idle to run and back "
|
|
"three times with the tube dark and the heater off, both coolant sensors read "
|
|
"at every edge. The fan's return current shifts both readings by a number of "
|
|
"ADC counts the engine adds back (cool_aa_offset_counts). PASS = the tool "
|
|
"reports a recommendation, the six edges agree within its spread limit, and "
|
|
"the value sits inside the setting's legal range. The setting is not written.")
|
|
def aa_offset_calibrate(ctx):
|
|
fc = ctx.forgectrl
|
|
ev = ctx.evidence
|
|
st, body = fc.get("/diag/status")
|
|
ctx.check(st == 200 and isinstance(body, dict), "GET /diag/status -> %s", st)
|
|
ctx.check(not body.get("running"), "a diagnostic is already running (%s)", body.get("tool"))
|
|
st, body = fc.post("/diag/aa-offset-calibrate")
|
|
ctx.log("POST /diag/aa-offset-calibrate -> %s %s", st, body if isinstance(body, dict) else "")
|
|
ctx.check(st == 202 and isinstance(body, dict) and body.get("started") is True,
|
|
"could not start aa-offset-calibrate (%s %s)", st, body)
|
|
result = None
|
|
last_phase = None
|
|
t0 = time.time()
|
|
try:
|
|
while time.time() - t0 < AA_CAL_TIMEOUT_S:
|
|
ctx.checkpoint()
|
|
st, d = fc.get("/diag/status")
|
|
if st == 200 and isinstance(d, dict):
|
|
if d.get("phase") != last_phase:
|
|
last_phase = d.get("phase")
|
|
ctx.log("phase: %s", last_phase)
|
|
if not d.get("running") and d.get("result") is not None:
|
|
result = d.get("result")
|
|
for line in d.get("log", [])[-10:]:
|
|
ctx.log(" diag: %s", line)
|
|
break
|
|
time.sleep(2)
|
|
except BaseException:
|
|
fc.post("/diag/abort")
|
|
raise
|
|
ctx.check(result is not None, "aa-offset-calibrate did not finish within %d s", AA_CAL_TIMEOUT_S)
|
|
ev["result"] = result
|
|
ctx.check("error" not in result, "aa-offset-calibrate error: %s", result.get("error"))
|
|
ctx.log("offset %s counts, spread %s, recommend %s, edges %s", result.get("offset_counts"),
|
|
result.get("spread_counts"), result.get("recommend"), result.get("steps"))
|
|
ctx.check("recommend" in result, "no recommendation in %s", result)
|
|
ctx.check(0 <= float(result["recommend"]) <= 60,
|
|
"recommendation %s outside the setting's range 0..60", result["recommend"])
|
|
ctx.check(fc.wait_idle(120, abort=ctx.aborted), "machine did not return to idle after the diagnostic")
|
|
|
|
|
|
IDLE_DUTY = {"thermal/exhaust_pwm": 0, "thermal/intake_pwm": 0} # forgectrl's idle posture
|
|
TACH_KEYS = ("exhaust", "intake_1", "intake_2")
|
|
SAMPLE_S = 5 # tach sampling period (the big exhaust fan coasts for tens of seconds)
|
|
STABLE_SAMPLES = 3 # consecutive agreeing samples that make an idle reference
|
|
IDLE_REF_TIMEOUT_S = 180 # a previous test's cooldown + spin-down
|
|
COOLDOWN_TIMEOUT_S = 240 # the engine's smoke phase + idle drop + spin-down
|
|
|
|
|
|
def _duties():
|
|
return {k: hw.sysfs_int(k) for k in IDLE_DUTY}
|
|
|
|
|
|
def _tach_close(now, ref):
|
|
"""Every tach at or below its idle reference, within the tolerance a
|
|
tach reading wanders by (150 rpm or 15 %). Lower is quieter, never a
|
|
fault: the reference is an idle level, not a target."""
|
|
return all(now.get(k, 0) - ref.get(k, 0) <= max(150, 0.15 * max(ref.get(k, 0), 1))
|
|
for k in TACH_KEYS)
|
|
|
|
|
|
def _tach_stable(a, b):
|
|
return all(abs(a.get(k, 0) - b.get(k, 0)) <= max(100, 0.10 * max(a.get(k, 0), 1)) for k in TACH_KEYS)
|
|
|
|
|
|
@test("cooling.fans-quiet-after-motion", title="Fan profile returns to idle after motion and after M8/M9",
|
|
subsystem="cooling", kind="auto", mode="grbl", est_min=3,
|
|
covers=_COOL_COVERS + [("forgectrl", "src/super.c")], requires=["motion.pacing"],
|
|
steps=["Bed clear; the head needs 20 mm of free +X travel."],
|
|
description="A dry jog and an M8/M9 cycle must not leave the run fan profile on: within "
|
|
"the cooldown the engine is back at its idle duty and the exhaust/intake tachs "
|
|
"are back at (or below) the idle level they held before the test. The idle "
|
|
"reference is taken only once the engine is idle and the tachs have stopped "
|
|
"changing, so a previous test's spin-down cannot be mistaken for idle.")
|
|
def fans_quiet(ctx):
|
|
fc = ctx.forgectrl
|
|
ev = ctx.evidence
|
|
|
|
def fans():
|
|
s = fc.status()
|
|
return dict(s.get("fans") or {})
|
|
|
|
def phase():
|
|
st, c = fc.get("/cool/status")
|
|
return (c or {}).get("phase") if st == 200 and isinstance(c, dict) else None
|
|
|
|
# The idle reference: engine idle, idle duty applied, and tachs that
|
|
# have stopped changing (STABLE_SAMPLES consecutive samples that
|
|
# agree). A test that ran just before leaves the fans spinning down
|
|
# for tens of seconds after the engine goes idle; a reference taken
|
|
# then is not idle, and two samples can agree by chance mid-coast.
|
|
t0 = time.time()
|
|
before = None
|
|
recent = []
|
|
while time.time() - t0 < IDLE_REF_TIMEOUT_S:
|
|
ctx.sleep(SAMPLE_S)
|
|
now, ph, d = fans(), phase(), _duties()
|
|
ctx.log(" idle ref: phase %s duty %s fans %s", ph, d, now)
|
|
recent = (recent + [now])[-STABLE_SAMPLES:] if ph == "idle" and d == IDLE_DUTY else []
|
|
if len(recent) == STABLE_SAMPLES and all(_tach_stable(a, b) for a, b in zip(recent, recent[1:])):
|
|
before = now
|
|
break
|
|
ev["before"] = before
|
|
ev["idle_ref_s"] = round(time.time() - t0, 1)
|
|
ctx.check(before is not None, "the fans never settled to an idle reference within %d s (last %s, "
|
|
"phase %s, duty %s)", IDLE_REF_TIMEOUT_S, recent[-1:] or None, phase(), _duties())
|
|
ctx.log("idle reference after %s s: %s", ev["idle_ref_s"], before)
|
|
|
|
with ctx.grbl() as g:
|
|
st = g.status_report()
|
|
ctx.check(st["state"].startswith("Idle"), "controller is %s", st["state"])
|
|
g.command("G91")
|
|
g.command("$J=G91X20F2400")
|
|
t0 = time.time()
|
|
while time.time() - t0 < 30 and not g.status_report()["state"].startswith("Idle"):
|
|
ctx.sleep(0.2)
|
|
g.command("$J=G91X-20F2400")
|
|
while time.time() - t0 < 60 and not g.status_report()["state"].startswith("Idle"):
|
|
ctx.sleep(0.2)
|
|
g.command("M8")
|
|
ctx.sleep(3)
|
|
during = fans()
|
|
ev["during_m8"] = during
|
|
ev["duty_m8"] = _duties()
|
|
ctx.log("fans during M8: %s (duty %s)", during, ev["duty_m8"])
|
|
ctx.check(ev["duty_m8"] != IDLE_DUTY, "M8 did not raise the fan duty off idle: %s", ev["duty_m8"])
|
|
g.command("M9")
|
|
g.command("G90")
|
|
# Cooldown: the engine's smoke phase, then the drop to idle duty, then
|
|
# the tachs coast down. Every sample is logged: a quiet pane here
|
|
# looks like a hang.
|
|
settle = None
|
|
t0 = time.time()
|
|
while time.time() - t0 < COOLDOWN_TIMEOUT_S:
|
|
ctx.sleep(SAMPLE_S)
|
|
now, ph, d = fans(), phase(), _duties()
|
|
ctx.log(" cooldown +%3.0f s: phase %s duty %s fans %s", time.time() - t0, ph, d, now)
|
|
if ph == "idle" and d == IDLE_DUTY and _tach_close(now, before):
|
|
settle = time.time() - t0
|
|
break
|
|
ev["after"] = fans()
|
|
ev["duty_after"] = _duties()
|
|
ev["settle_s"] = round(settle, 1) if settle is not None else None
|
|
ctx.log("fans after: %s duty %s (settled in %s s)", ev["after"], ev["duty_after"], ev["settle_s"])
|
|
ctx.check(settle is not None, "fans did not return to the idle profile within %d s: %s, duty %s, "
|
|
"phase %s (idle reference %s)", COOLDOWN_TIMEOUT_S, ev["after"], ev["duty_after"], phase(), before)
|
|
|
|
|
|
GATE_KEYS = ("cool_temp_max", "cool_temp_resume")
|
|
VERDICT_WAIT_S = 20 # the engine reloads settings at run start and ticks at 1 Hz
|
|
SESSION_END_WAIT_S = 15 # M9 -> the engine's phase leaves "run" (1 Hz reports, 1 Hz ticks)
|
|
GATE_LOG_LINES = "400" # how far back the run-start gate lines can sit in the forgectrl log
|
|
|
|
|
|
def _cool(fc):
|
|
st, c = fc.get("/cool/status")
|
|
return c if st == 200 and isinstance(c, dict) else {}
|
|
|
|
|
|
def _gate_state(fc, key):
|
|
g = (fc.settings().get("gates") or {}).get(key) or {}
|
|
return g.get("state"), g.get("value")
|
|
|
|
|
|
def _set_gates(ctx, fc, values):
|
|
"""POST the gate settings and confirm the reply carries them."""
|
|
st, body = fc.post("/settings", params=values)
|
|
ctx.check(st == 200 and isinstance(body, dict), "POST /settings %s -> %s %s", values, st, body)
|
|
for k, v in values.items():
|
|
ctx.check(body.get(k) == v, "settings reply has %s=%r, posted %r", k, body.get(k), v)
|
|
return body
|
|
|
|
|
|
def _session_ended(ctx, fc, what):
|
|
"""After M9 the GRBL client's next report ends the engine's run
|
|
session; the client reports at 1 Hz and the engine samples at 1 Hz,
|
|
so an M8 sent inside that window is not a new session and nothing is
|
|
re-read. Wait until the phase has left "run"."""
|
|
t0 = time.time()
|
|
while time.time() - t0 < SESSION_END_WAIT_S:
|
|
ctx.sleep(1)
|
|
if _cool(fc).get("phase") != "run":
|
|
return True
|
|
ctx.log("%s: the engine is still in phase run %d s after M9", what, SESSION_END_WAIT_S)
|
|
return False
|
|
|
|
|
|
def _run_session(ctx, g, fc, until, what, wait=None):
|
|
"""M8 opens a run session (the engine re-reads its settings there and
|
|
ticks the gates at 1 Hz); wait for `until(cool)` to hold, then M9 and
|
|
wait for the session to end, so the next M8 is a new one."""
|
|
ctx.check(_cool(fc).get("phase") != "run", "%s: a run session is already open", what)
|
|
g.command("M8")
|
|
try:
|
|
t0 = time.time()
|
|
c = {}
|
|
while time.time() - t0 < (wait or VERDICT_WAIT_S):
|
|
ctx.sleep(1)
|
|
c = _cool(fc)
|
|
if until(c):
|
|
break
|
|
ctx.log("%s: verdict %s fire_ok %s hold %s gates_off %s (after %.0f s)", what,
|
|
c.get("verdict"), c.get("fire_ok"), c.get("hold"), c.get("gates_off"), time.time() - t0)
|
|
return c
|
|
finally:
|
|
g.command("M9")
|
|
_session_ended(ctx, fc, what)
|
|
|
|
|
|
def _after_session(ctx, fc, wait=5, until=None):
|
|
"""The engine's state a few ticks after a session ended: the first
|
|
sample out of phase run that satisfies `until` (default: verdict OK),
|
|
or the last sample taken."""
|
|
until = until or (lambda c: c.get("verdict") == "OK")
|
|
c = {}
|
|
t0 = time.time()
|
|
while time.time() - t0 < wait:
|
|
ctx.sleep(1)
|
|
c = _cool(fc)
|
|
if c.get("phase") != "run" and until(c):
|
|
break
|
|
return c
|
|
|
|
|
|
def _tail_has(fc, needle):
|
|
st, body = fc.get("/logs/tail", params={"name": "forgectrl", "lines": GATE_LOG_LINES})
|
|
text = body.get("text", "") if st == 200 and isinstance(body, dict) else ""
|
|
return needle in text
|
|
|
|
|
|
@test("cooling.gate-off", title="A gate setting trips inside its range and is off at its far end",
|
|
subsystem="cooling", kind="auto", mode="grbl", est_min=3,
|
|
covers=_COOL_COVERS, requires=["kernel.latch-locked-idle"],
|
|
steps=["Machine idle, coolant at room temperature (above 8 C). The test writes the coolant "
|
|
"ceiling and resume gate and restores them; three short M8/M9 cycles spin the fans."],
|
|
description="The coolant ceiling is a plain setting with a wide legal range whose top "
|
|
"turns the gate off by value. Set just above its legal minimum it must trip "
|
|
"(OVERTEMP, hold, fire blocked) at the next run start; set to its top the "
|
|
"engine must skip the gate (verdict OK), report it in gates_off on /status "
|
|
"and /cool/status, say so in the settings reply, and log the run-start line; "
|
|
"restored, everything reads as before. Alongside: /status carries the watched "
|
|
"board temperatures (chassis and SoC die in degrees, supply as a raw count, the "
|
|
"CPU unthrottled) and every run session ends with them ranged into one log line.")
|
|
def gate_off(ctx):
|
|
fc = ctx.forgectrl
|
|
ev = ctx.evidence
|
|
before = fc.settings()
|
|
orig = {k: before.get(k, "") for k in GATE_KEYS}
|
|
ev["orig"] = orig
|
|
ctx.log("original: %s", orig)
|
|
st0 = fc.status()
|
|
up = (st0.get("coolant") or {}).get("up_c")
|
|
ctx.check(up is not None and up > 8.0, "coolant too cold for the trip leg (up_c %s)", up)
|
|
# The board temperatures ride /status, watched and not gated: the
|
|
# chassis in degrees, the supply as its raw count.
|
|
temps = st0.get("temps") or {}
|
|
ev["temps"] = temps
|
|
ctx.check(isinstance(temps.get("chassis_c"), (int, float)) and 5.0 <= temps["chassis_c"] <= 80.0,
|
|
"/status temps.chassis_c is not a plausible chassis temperature: %s", temps)
|
|
ctx.check(isinstance(temps.get("supply_raw"), int) and 0 <= temps["supply_raw"] <= 1023,
|
|
"/status temps.supply_raw is not a 10-bit count: %s", temps)
|
|
ctx.check(isinstance(temps.get("soc_c"), (int, float)) and 10.0 <= temps["soc_c"] <= 100.0,
|
|
"/status temps.soc_c is not a plausible die temperature: %s", temps)
|
|
ctx.check(temps.get("soc_throttle") == 0,
|
|
"the CPU is throttled (or its cooling device is missing) at idle: %s", temps)
|
|
c0 = _cool(fc)
|
|
ctx.check(c0.get("verdict") == "OK", "engine is not at OK before the test: %s", c0)
|
|
ctx.check(c0.get("gates_off") == [], "a gate is already off: %s", c0.get("gates_off"))
|
|
g_default = (before.get("gates") or {}).get("cool_temp_max") or {}
|
|
ctx.check(g_default.get("gate") == "coolant_max" and g_default.get("off") == "high",
|
|
"settings reply does not describe the ceiling as the coolant_max gate, off at its top: %s", g_default)
|
|
top = g_default.get("hi")
|
|
bottom = g_default.get("lo")
|
|
ctx.check(isinstance(top, (int, float)) and isinstance(bottom, (int, float)), "no range in the reply: %s", g_default)
|
|
|
|
restored = False
|
|
with ctx.grbl() as grbl:
|
|
st = grbl.status_report()
|
|
ctx.check(st["state"].startswith("Idle"), "controller is %s", st["state"])
|
|
try:
|
|
|
|
# Leg 1: a ceiling the coolant is already over. Legal, outside
|
|
# the band (warned), and it must trip at the next run start.
|
|
_set_gates(ctx, fc, {"cool_temp_max": str(bottom + 1), "cool_temp_resume": str(bottom)})
|
|
state, val = _gate_state(fc, "cool_temp_max")
|
|
ev["trip_state"] = state
|
|
ctx.check(state == "warn", "a ceiling of %s reports state %r, expected warn", val, state)
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "OVERTEMP", "trip leg")
|
|
ev["trip"] = c
|
|
ctx.check(c.get("verdict") == "OVERTEMP", "ceiling %s C with coolant at %.1f C did not trip: %s",
|
|
bottom + 1, up, c)
|
|
ctx.check(c.get("fire_ok") is False and c.get("hold") is True,
|
|
"OVERTEMP without fire blocked and a hold: %s", c)
|
|
ctx.check(c.get("gates_off") == [], "a tripped gate is not an off gate: %s", c.get("gates_off"))
|
|
|
|
# Leg 2: the ceiling at its top. Off by value: no gate, verdict
|
|
# back to OK at the next run start, and said out loud.
|
|
_set_gates(ctx, fc, {"cool_temp_max": str(top), "cool_temp_resume": orig["cool_temp_resume"]})
|
|
state, val = _gate_state(fc, "cool_temp_max")
|
|
ev["off_state"] = state
|
|
ctx.check(state == "off", "a ceiling of %s reports state %r, expected off", val, state)
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "OK" and c.get("gates_off"), "off leg")
|
|
ev["off"] = c
|
|
ctx.check(c.get("verdict") == "OK", "ceiling at %s did not clear the gate: %s", top, c)
|
|
ctx.check(c.get("gates_off") == ["coolant_max"], "/cool/status gates_off %s, expected [coolant_max]",
|
|
c.get("gates_off"))
|
|
s_off = fc.status().get("gates_off")
|
|
ctx.check(s_off == ["coolant_max"], "/status gates_off %s, expected [coolant_max]", s_off)
|
|
ctx.check(_tail_has(fc, "gate coolant_max OFF: cool_temp_max = %g" % top),
|
|
"the run-start log line for the off gate is missing from the forgectrl log")
|
|
|
|
# Restore, and prove the restore: the next run start reloads.
|
|
_set_gates(ctx, fc, orig)
|
|
restored = True
|
|
state, val = _gate_state(fc, "cool_temp_max")
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "OK" and not c.get("gates_off"),
|
|
"restored")
|
|
ev["restored"] = c
|
|
ctx.check(c.get("verdict") == "OK" and c.get("gates_off") == [],
|
|
"engine did not return to OK with no gate off after the restore: %s", c)
|
|
ctx.log("restored ceiling %s reports state %s", val, state)
|
|
# Every run session ends with the board temperatures ranged
|
|
# into one line.
|
|
ctx.check(_tail_has(fc, "temps this job: chassis ") and _tail_has(fc, ", soc "),
|
|
"the run-end board-temperature line (chassis, soc, supply) is missing from the "
|
|
"forgectrl log")
|
|
finally:
|
|
if not restored:
|
|
# The engine reads settings at run start only: restoring
|
|
# the file is not enough, a hold taken against the test's
|
|
# ceiling would stand until the operator's next job.
|
|
st, body = fc.post("/settings", params=orig)
|
|
ctx.log("restore on failure: POST /settings %s -> %s", orig, st)
|
|
try:
|
|
c = _run_session(ctx, grbl, fc,
|
|
lambda c: c.get("verdict") == "OK" and not c.get("gates_off"),
|
|
"restore on failure")
|
|
ctx.log("restore on failure: engine %s gates_off %s", c.get("verdict"), c.get("gates_off"))
|
|
except Exception as e: # the original failure is the one to report
|
|
ctx.log("restore on failure: run session did not complete (%s)", e)
|
|
after = fc.settings()
|
|
ctx.check(all(after.get(k, "") == orig[k] for k in GATE_KEYS),
|
|
"settings not restored: %s", {k: after.get(k) for k in GATE_KEYS})
|
|
ctx.check(fc.wait_idle(60, abort=ctx.aborted), "machine did not return to idle")
|
|
|
|
|
|
CRIT_KEYS = ("cool_temp_max", "cool_temp_resume", "cool_temp_critical_c")
|
|
|
|
|
|
@test("cooling.critical-tier", title="The coolant critical line is a fault above the ceiling's pause",
|
|
subsystem="cooling", kind="auto", mode="grbl", est_min=3,
|
|
covers=_COOL_COVERS + [("forgectrl", "src/main.c")], requires=["cooling.gate-off"],
|
|
steps=["Machine idle, coolant at room temperature (above 8 C). The test writes the coolant "
|
|
"ceiling, the resume gate and the critical line and restores them; three short M8/M9 "
|
|
"cycles spin the fans."],
|
|
description="Two tiers on the upstream coolant sensor: the ceiling pauses (OVERTEMP, resume "
|
|
"below the resume gate), the critical line above it is a fault. With the ceiling "
|
|
"and the critical line both under the coolant's temperature a run session must "
|
|
"read CRITICAL rather than OVERTEMP (fire blocked, hold, no resume), the fault "
|
|
"must end with the session, and the settings API must refuse a critical line at "
|
|
"or below the ceiling; with the critical line at its top the gate is off by "
|
|
"value (gates_off names it) and the ceiling alone pauses; restored, the next "
|
|
"session runs OK with nothing off.")
|
|
def critical_tier(ctx):
|
|
fc = ctx.forgectrl
|
|
ev = ctx.evidence
|
|
before = fc.settings()
|
|
orig = {k: before.get(k, "") for k in CRIT_KEYS}
|
|
ev["orig"] = orig
|
|
ctx.log("original: %s", orig)
|
|
up = (fc.status().get("coolant") or {}).get("up_c")
|
|
ctx.check(up is not None and up > 8.0, "coolant too cold for the trip leg (up_c %s)", up)
|
|
c0 = _cool(fc)
|
|
ctx.check(c0.get("verdict") == "OK" and c0.get("gates_off") == [],
|
|
"engine is not at OK with every gate on before the test: %s", c0)
|
|
gates = before.get("gates") or {}
|
|
ceil = gates.get("cool_temp_max") or {}
|
|
crit = gates.get("cool_temp_critical_c") or {}
|
|
ctx.check(crit.get("gate") == "coolant_critical" and crit.get("off") == "high",
|
|
"settings reply does not describe the critical line as the coolant_critical gate, off at "
|
|
"its top: %s", crit)
|
|
bottom, top = ceil.get("lo"), crit.get("hi")
|
|
ctx.check(isinstance(bottom, (int, float)) and isinstance(top, (int, float)),
|
|
"no ranges in the reply: %s %s", ceil, crit)
|
|
ctx.check(isinstance(crit.get("lo"), (int, float)) and crit.get("lo") > bottom,
|
|
"the critical line's floor %s is not above the ceiling's %s", crit.get("lo"), bottom)
|
|
|
|
# The cross-check: a critical line at or below the ceiling is refused
|
|
# before anything is written.
|
|
st, body = fc.post("/settings", params={"cool_temp_max": "33", "cool_temp_critical_c": "33"})
|
|
ev["cross_check"] = {"status": st, "body": body}
|
|
if st == 200:
|
|
fc.post("/settings", params=orig) # undo before failing
|
|
ctx.check(st == 400, "a critical line equal to the ceiling was accepted: %s %s", st, body)
|
|
after = fc.settings()
|
|
ctx.check(all(after.get(k, "") == orig[k] for k in CRIT_KEYS),
|
|
"the refused POST changed a setting: %s", {k: after.get(k) for k in CRIT_KEYS})
|
|
# A ceiling at its off end is no ceiling: the default line stands
|
|
# alone, and the POST that turns the ceiling off is accepted.
|
|
st, body = fc.post("/settings", params={"cool_temp_max": str(ceil.get("hi"))})
|
|
ev["ceiling_off_accepted"] = st
|
|
if st == 200:
|
|
fc.post("/settings", params=orig)
|
|
ctx.check(st == 200, "the ceiling at its off end %s was refused against the critical line: %s %s",
|
|
ceil.get("hi"), st, body)
|
|
|
|
restored = False
|
|
with ctx.grbl() as grbl:
|
|
st = grbl.status_report()
|
|
ctx.check(st["state"].startswith("Idle"), "controller is %s", st["state"])
|
|
try:
|
|
# Leg 1: ceiling and critical line both under the coolant's
|
|
# temperature. The fail tier wins: CRITICAL, not OVERTEMP.
|
|
low = {"cool_temp_max": str(bottom + 1), "cool_temp_resume": str(bottom),
|
|
"cool_temp_critical_c": str(bottom + 2)}
|
|
_set_gates(ctx, fc, low)
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "CRITICAL", "critical leg")
|
|
ev["critical"] = c
|
|
ctx.check(c.get("verdict") == "CRITICAL",
|
|
"critical line %s C with coolant at %.1f C did not fault (verdict %s): %s",
|
|
bottom + 2, up, c.get("verdict"), c)
|
|
ctx.check(c.get("fire_ok") is False and c.get("hold") is True,
|
|
"CRITICAL without fire blocked and a hold: %s", c)
|
|
ctx.check(c.get("resume_ok") is not True, "a coolant fault offered a resume: %s", c)
|
|
ctx.check("CRITICAL" in (c.get("reason") or "") and "coolant" in (c.get("reason") or ""),
|
|
"the reason does not name the tier and the coolant: %r", c.get("reason"))
|
|
ctx.check(c.get("gates_off") == [], "a tripped gate is not an off gate: %s", c.get("gates_off"))
|
|
# The fault ends with the session; the ceiling, still under the
|
|
# coolant, keeps its pause (OVERTEMP), never CRITICAL.
|
|
c = _after_session(ctx, fc, until=lambda c: c.get("verdict") != "CRITICAL")
|
|
ev["critical_after"] = c
|
|
ctx.check(c.get("verdict") == "OVERTEMP",
|
|
"after the faulted session the engine reads %s, expected the ceiling's OVERTEMP: %s",
|
|
c.get("verdict"), c)
|
|
ctx.check("CRITICAL" not in (c.get("reason") or ""),
|
|
"the reason still names the ended critical fault under the ceiling's hold: %r",
|
|
c.get("reason"))
|
|
|
|
# Leg 2: the critical line at its top is the gate off; the
|
|
# ceiling alone pauses, and gates_off says so.
|
|
_set_gates(ctx, fc, {"cool_temp_critical_c": str(top)})
|
|
c = _run_session(ctx, grbl, fc,
|
|
lambda c: c.get("verdict") == "OVERTEMP" and "coolant_critical" in (c.get("gates_off") or []),
|
|
"critical off leg")
|
|
ev["critical_off"] = c
|
|
ctx.check(c.get("verdict") == "OVERTEMP",
|
|
"with the critical line off the ceiling did not pause (verdict %s): %s", c.get("verdict"), c)
|
|
ctx.check("coolant_critical" in (c.get("gates_off") or []),
|
|
"gates_off %s lacks coolant_critical", c.get("gates_off"))
|
|
ctx.check(_tail_has(fc, "gate coolant_critical OFF: cool_temp_critical_c = %g" % top),
|
|
"the run-start log line for the off gate is missing from the forgectrl log")
|
|
|
|
# Restore, and prove it: OK, nothing off.
|
|
_set_gates(ctx, fc, orig)
|
|
restored = True
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "OK" and not c.get("gates_off"),
|
|
"restored")
|
|
ev["restored"] = c
|
|
ctx.check(c.get("verdict") == "OK" and c.get("gates_off") == [],
|
|
"engine did not return to OK with every gate on after the restore: %s", c)
|
|
finally:
|
|
if not restored:
|
|
st, body = fc.post("/settings", params=orig)
|
|
ctx.log("restore on failure: POST /settings %s -> %s", orig, st)
|
|
try:
|
|
c = _run_session(ctx, grbl, fc,
|
|
lambda c: c.get("verdict") == "OK" and not c.get("gates_off"),
|
|
"restore on failure")
|
|
ctx.log("restore on failure: engine %s gates_off %s", c.get("verdict"), c.get("gates_off"))
|
|
except Exception as e: # the original failure is the one to report
|
|
ctx.log("restore on failure: run session did not complete (%s)", e)
|
|
after = fc.settings()
|
|
ctx.check(all(after.get(k, "") == orig[k] for k in CRIT_KEYS),
|
|
"settings not restored: %s", {k: after.get(k) for k in CRIT_KEYS})
|
|
|
|
|
|
FAN_KEYS = ("cool_tach_exhaust_min_rpm", "cool_purge_min_current", "cool_fan_grace_s")
|
|
FAN_GRACE_S = "8" # past the intakes' 7 s to 90 percent, so only the leg's floor trips
|
|
FAN_TRIP_WAIT_S = 20 # grace + three ticks, with slack for the 1 Hz pipeline
|
|
|
|
|
|
def _fan_gate(c, name):
|
|
return ((c.get("fan_gates") or {}).get(name) or {})
|
|
|
|
|
|
@test("cooling.fan-gate-trips", title="A fan under its floor past the grace is a fault; a floor of zero is off",
|
|
subsystem="cooling", kind="auto", mode="grbl", est_min=4,
|
|
covers=_COOL_COVERS + [("forgectrl", "src/main.c")], requires=["cooling.gate-off"],
|
|
steps=["Machine idle, fans quiet. The test writes the exhaust floor, the purge current floor and "
|
|
"the spin-up grace and restores them; four short M8/M9 cycles spin the fans."],
|
|
description="The airflow gates judge a fan commanded at the cut fan profile, which a bare M8 "
|
|
"applies, armed or not. An exhaust floor no fan "
|
|
"can meet must trip AIRFLOW after the grace plus three ticks (hold, fire blocked, no "
|
|
"resume while the session lasts) and the fault must end with the session (verdict OK, "
|
|
"no hold, once the session is over); a purge current floor at the ADC rail must trip "
|
|
"the same way; a floor of zero must read off in gates_off and trip nothing; restored, "
|
|
"the next session runs OK with every fan reading at or above its floor.")
|
|
def fan_gate_trips(ctx):
|
|
fc = ctx.forgectrl
|
|
ev = ctx.evidence
|
|
before = fc.settings()
|
|
orig = {k: before.get(k, "") for k in FAN_KEYS}
|
|
ev["orig"] = orig
|
|
ctx.log("original: %s", orig)
|
|
gates = before.get("gates") or {}
|
|
exh = gates.get("cool_tach_exhaust_min_rpm") or {}
|
|
prg = gates.get("cool_purge_min_current") or {}
|
|
ctx.check(exh.get("gate") == "exhaust" and exh.get("off") == "low",
|
|
"settings reply does not describe the exhaust floor as the exhaust gate, off at zero: %s", exh)
|
|
ctx.check(prg.get("gate") == "purge" and prg.get("off") == "low",
|
|
"settings reply does not describe the purge floor as the purge gate, off at zero: %s", prg)
|
|
c0 = _cool(fc)
|
|
ctx.check(c0.get("verdict") == "OK" and c0.get("gates_off") == [],
|
|
"engine is not at OK with every gate on before the test: %s", c0)
|
|
|
|
restored = False
|
|
with ctx.grbl() as grbl:
|
|
st = grbl.status_report()
|
|
ctx.check(st["state"].startswith("Idle"), "controller is %s", st["state"])
|
|
try:
|
|
# Leg 1: an exhaust floor at the legal maximum. No fan reaches it,
|
|
# so after the grace and three ticks the gate trips a fault.
|
|
_set_gates(ctx, fc, {"cool_tach_exhaust_min_rpm": str(exh.get("hi")), "cool_fan_grace_s": FAN_GRACE_S})
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "AIRFLOW", "exhaust trip leg",
|
|
wait=FAN_TRIP_WAIT_S)
|
|
ev["exhaust_trip"] = {"cool": c, "gate": _fan_gate(c, "exhaust")}
|
|
ctx.check(c.get("verdict") == "AIRFLOW", "an exhaust floor of %s rpm did not trip: %s", exh.get("hi"), c)
|
|
ctx.check(c.get("fire_ok") is False and c.get("hold") is True,
|
|
"AIRFLOW without fire blocked and a hold: %s", c)
|
|
ctx.check(c.get("resume_ok") is not True, "a fan fault offered a resume: %s", c)
|
|
ctx.check(_fan_gate(c, "exhaust").get("state") == "TRIPPED",
|
|
"the exhaust gate does not read TRIPPED: %s", c.get("fan_gates"))
|
|
ctx.check("exhaust" in (c.get("reason") or ""), "the reason does not name the fan: %r", c.get("reason"))
|
|
# The fault is the session's: with the session over, the
|
|
# verdict is back to OK and nothing holds (jogs and the next
|
|
# job's pre-check must not see a fan fault at idle).
|
|
c = _after_session(ctx, fc)
|
|
ev["exhaust_trip_after"] = c
|
|
ctx.check(c.get("verdict") == "OK" and c.get("hold") is False,
|
|
"the fan fault outlived its run session: %s", c)
|
|
|
|
# Leg 2: the purge fan by current, floor at the ADC rail.
|
|
_set_gates(ctx, fc, {"cool_tach_exhaust_min_rpm": orig["cool_tach_exhaust_min_rpm"],
|
|
"cool_purge_min_current": str(prg.get("hi"))})
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "AIRFLOW", "purge trip leg",
|
|
wait=FAN_TRIP_WAIT_S)
|
|
ev["purge_trip"] = {"cool": c, "gate": _fan_gate(c, "purge")}
|
|
ctx.check(c.get("verdict") == "AIRFLOW" and _fan_gate(c, "purge").get("state") == "TRIPPED",
|
|
"a purge current floor of %s did not trip: %s", prg.get("hi"), c)
|
|
|
|
# Leg 3: the exhaust floor at zero is the gate off: nothing trips,
|
|
# gates_off says so, and the other fans are judged on their own.
|
|
_set_gates(ctx, fc, {"cool_tach_exhaust_min_rpm": "0",
|
|
"cool_purge_min_current": orig["cool_purge_min_current"]})
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "OK" and "exhaust" in (c.get("gates_off") or [])
|
|
and _fan_gate(c, "exhaust").get("state") == "off",
|
|
"exhaust off leg")
|
|
ev["exhaust_off"] = {"cool": c, "gate": _fan_gate(c, "exhaust")}
|
|
ctx.check(c.get("verdict") == "OK", "the exhaust floor at zero did not clear the gate: %s", c)
|
|
ctx.check("exhaust" in (c.get("gates_off") or []), "gates_off %s lacks exhaust", c.get("gates_off"))
|
|
ctx.check(_fan_gate(c, "exhaust").get("state") == "off",
|
|
"the exhaust gate does not read off: %s", c.get("fan_gates"))
|
|
|
|
# Restore, and prove it: every fan at or above its floor, nothing off.
|
|
_set_gates(ctx, fc, orig)
|
|
restored = True
|
|
# The restored grace is the shipped one, so this leg waits it out.
|
|
c = _run_session(ctx, grbl, fc,
|
|
lambda c: c.get("verdict") == "OK" and not c.get("gates_off")
|
|
and all(g.get("state") == "ok" for g in (c.get("fan_gates") or {}).values()),
|
|
"restored", wait=FAN_TRIP_WAIT_S + 20)
|
|
ev["restored"] = c.get("fan_gates")
|
|
ctx.check(c.get("verdict") == "OK" and c.get("gates_off") == [],
|
|
"engine did not return to OK with every gate on after the restore: %s", c)
|
|
bad = {k: g for k, g in (c.get("fan_gates") or {}).items() if g.get("state") != "ok"}
|
|
ctx.check(not bad, "fans not at or above their floors after the grace: %s", bad)
|
|
ctx.log("fans at run duty: %s", {k: "%s/%s" % (g.get("reading"), g.get("floor"))
|
|
for k, g in (c.get("fan_gates") or {}).items()})
|
|
finally:
|
|
if not restored:
|
|
st, body = fc.post("/settings", params=orig)
|
|
ctx.log("restore on failure: POST /settings %s -> %s", orig, st)
|
|
try:
|
|
c = _run_session(ctx, grbl, fc, lambda c: c.get("verdict") == "OK" and not c.get("gates_off"),
|
|
"restore on failure")
|
|
ctx.log("restore on failure: engine %s gates_off %s", c.get("verdict"), c.get("gates_off"))
|
|
except Exception as e: # the original failure is the one to report
|
|
ctx.log("restore on failure: run session did not complete (%s)", e)
|
|
after = fc.settings()
|
|
ctx.check(all(after.get(k, "") == orig[k] for k in FAN_KEYS),
|
|
"settings not restored: %s", {k: after.get(k) for k in FAN_KEYS})
|
|
ctx.check(fc.wait_idle(60, abort=ctx.aborted), "machine did not return to idle")
|
|
|
|
|
|
# The flow check under a lit tube. With a prompt press the tube is lit for
|
|
# most of the arm-time window, which adds about 1.5 C to the heater rise at
|
|
# full power; the engine takes that share off from the tube current before
|
|
# the limit (cool_laser_heat_*), reads its baseline and end as means, and
|
|
# says so on the verdict line: "verified (heater rise 11.3 C, dT 9.6 C;
|
|
# laser 0.8 off 12.0)". The share on the line is the proof the window and
|
|
# the fire overlapped; the judged rise inside the dark band is the proof
|
|
# the share was right.
|
|
LOAD_FEED = 1500 # mm/min: 25 mm/s, the engrave dose that does not char
|
|
LOAD_PITCH = 0.3 # mm between lines
|
|
LOAD_WIDTH = 30.0 # mm, the line length (+X)
|
|
LOAD_LINES = 27 # two 30 x 4 mm fills back to back, about 35 s lit
|
|
LOAD_SHARE_MIN_C = 0.3 # the tube was lit inside the window
|
|
LOAD_MARGIN_C = 1.0 # the judged rise this far under the limit
|
|
LOAD_VERDICT_WAIT_S = 120 # the window opens ~15 s into the session and runs 50 s
|
|
LOAD_LOG_LINES = "300"
|
|
_LOAD_LINE_RX = None
|
|
|
|
|
|
def _load_verdict_rx():
|
|
global _LOAD_LINE_RX
|
|
if _LOAD_LINE_RX is None:
|
|
import re
|
|
_LOAD_LINE_RX = re.compile(
|
|
r"(COOLANT FLOW SUSPECT|COOLANT FLOW FAULT|coolant flow verified|"
|
|
r"coolant flow suspicion cleared|coolant flow recovered)[^\n]*?heater rise ([0-9.]+) C"
|
|
r"(?: \(limit ([0-9.]+))?, dT ([0-9.]+)(?: C)?(?:; laser ([0-9.]+) off ([0-9.]+))?\)?")
|
|
return _LOAD_LINE_RX
|
|
|
|
|
|
def _load_fill():
|
|
lines = []
|
|
for i in range(LOAD_LINES):
|
|
lines.append("G1 X%g F%d" % (LOAD_WIDTH if i % 2 == 0 else -LOAD_WIDTH, LOAD_FEED))
|
|
if i < LOAD_LINES - 1:
|
|
lines.append("G1 Y%g F%d" % (LOAD_PITCH, LOAD_FEED))
|
|
return lines
|
|
|
|
|
|
def _forgectrl_tail(fc):
|
|
st, body = fc.get("/logs/tail", params={"name": "forgectrl", "lines": LOAD_LOG_LINES})
|
|
return body.get("text", "") if st == 200 and isinstance(body, dict) else ""
|
|
|
|
|
|
@test("cooling.flow-under-load", title="The flow check reads true with the tube lit through its window",
|
|
subsystem="cooling", kind="live", mode="grbl", est_min=4,
|
|
covers=_COOL_COVERS + [("forgectrl", "src/main.c")],
|
|
requires=["laser.emission-witness", "cooling.flow-verify"], actions=["button"],
|
|
steps=["Scrap under the head with 35 mm of free +X and 10 mm of +Y travel; lid closed; exhaust on.",
|
|
"Press the physical button AS SOON AS it lights white: the check must run while the "
|
|
"tube is lit, and the share on the verdict line is the proof it did."],
|
|
description="Two 30 x 4 mm fills at full power on the press (about 35 s lit), the window "
|
|
"held open until the engine's flow verdict lands. The verdict must be "
|
|
"'verified' with the laser's share on the line (at least 0.3 C: the tube was "
|
|
"lit inside the window) and the judged rise at least 1 C under the limit, "
|
|
"where the same check read within tenths of the limit before the engine took "
|
|
"the tube's share off and read its baseline as a mean.")
|
|
def flow_under_load(ctx):
|
|
from .laser import sample, prepare, LiveJob, ARM_CUE, run_and_sample, wait_disarm
|
|
fc = ctx.forgectrl
|
|
ev = ctx.evidence
|
|
state, check_s = _gate_state(fc, "cool_flow_check_s")
|
|
_st, limit = _gate_state(fc, "cool_flow_rise")
|
|
ctx.check(state != "off" and check_s, "the flow check is off (cool_flow_check_s=%s)", check_s)
|
|
ctx.check(limit, "cool_flow_rise unreadable")
|
|
ev.update({"check_s": check_s, "limit_c": limit})
|
|
before = _forgectrl_tail(fc).count("heater rise")
|
|
# The fill ends one line length out and (LOAD_LINES - 1) pitches up;
|
|
# the job brings the head back so the baseline finds it where it began.
|
|
back = "G0 X%g Y%g" % (-LOAD_WIDTH if LOAD_LINES % 2 else 0.0, -LOAD_PITCH * (LOAD_LINES - 1))
|
|
job = ["G91", "G21", "M3 S1000"] + _load_fill() + ["M5", back]
|
|
line = None
|
|
heater_seen = False
|
|
with ctx.grbl() as g, LiveJob(ctx, g):
|
|
prepare(ctx, g)
|
|
base = sample(ctx)
|
|
ctx.check(base, "forgectrl /status or /cool/status unavailable")
|
|
ctx.check(not base["emission"], "emission_samples nonzero before the job (%s)", base["emission"])
|
|
ctx.ready(ARM_CUE % "35 mm +X and 10 mm +Y")
|
|
ctx.arm_press()
|
|
t_job = time.time()
|
|
try:
|
|
samples = run_and_sample(ctx, g, job, overall_timeout=240)
|
|
finally:
|
|
ctx.clear_notice()
|
|
emis = [s["emission"] for s in samples if s["emission"] is not None]
|
|
ev["emission_peak"] = max(emis) if emis else 0
|
|
# An arm refused by a gate names itself: the engine's verdict left OK
|
|
# during the wait (AIRFLOW, OVERTEMP, a flow FAULT).
|
|
gates = sorted({s["verdict"] for s in samples if s.get("verdict") not in (None, "OK")})
|
|
ev["verdicts_seen"] = gates
|
|
ctx.check(ev["emission_peak"] > 0,
|
|
"no emission witnessed: %s" % ("the engine held the run (%s) before the arm"
|
|
% ", ".join(gates) if gates
|
|
else "arm refused, or no button press"))
|
|
# The window stays open (no M2) until the check has judged.
|
|
t0 = time.time()
|
|
while time.time() - t0 < LOAD_VERDICT_WAIT_S:
|
|
ctx.checkpoint()
|
|
if hw.sysfs_int("thermal/heater_pwm", 0) > 0:
|
|
heater_seen = True
|
|
text = _forgectrl_tail(fc)
|
|
if text.count("heater rise") > before:
|
|
m = None
|
|
for m in _load_verdict_rx().finditer(text):
|
|
pass
|
|
line = m.group(0) if m else None
|
|
break
|
|
ctx.sleep(1)
|
|
ev["heater_seen"] = heater_seen
|
|
ctx.log("M2: %s", g.command("G90\nM2", timeout=10))
|
|
dt = wait_disarm(ctx, 30)
|
|
ev["disarm_after_m2_s"] = round(dt, 1) if dt is not None else None
|
|
ctx.check(line, "the engine published no flow verdict within %d s of the job (heater seen: %s)",
|
|
LOAD_VERDICT_WAIT_S, heater_seen)
|
|
m = _load_verdict_rx().search(line)
|
|
kind, rise, _lim, dtc, share, raw = m.groups()
|
|
rise = float(rise)
|
|
share = float(share) if share else 0.0
|
|
raw = float(raw) if raw else rise
|
|
ev.update({"verdict_line": line, "kind": kind, "rise_c": rise, "dt_c": float(dtc),
|
|
"laser_share_c": share, "raw_rise_c": raw, "job_to_verdict_s": round(time.time() - t_job, 1)})
|
|
ctx.log("engine: %s", line)
|
|
ctx.check(kind == "coolant flow verified", "the check did not verify flow under load: %s", line)
|
|
ctx.check(share >= LOAD_SHARE_MIN_C,
|
|
"the tube's share on the line is %.1f C (under %.1f): the window and the fire did not "
|
|
"overlap - press the button as soon as it lights", share, LOAD_SHARE_MIN_C)
|
|
ctx.check(rise <= float(limit) - LOAD_MARGIN_C,
|
|
"judged rise %.1f C is within %.1f C of the %.1f C limit", rise, LOAD_MARGIN_C, float(limit))
|
|
ctx.check(dt is not None, "the window did not close after M2")
|
|
ctx.log("PASS: lit through the window, raw rise %.1f C, laser %.1f C off, judged %.1f C against %.1f "
|
|
"(dT %.1f), window closed %.1f s after M2", raw, share, rise, float(limit), float(dtc), dt)
|