Files
forgefirm/forgetest/tests
ScottW514 d6f648b539 forgetest: presence is proved once per test, not once per ready gate
The ready gate lives inside the arm-and-fire helper, and the kill drill
calls that helper twice, once for the expected stop and once for the
SIGKILL. So the presence gate asked the operator for a second press part
way through a test they had already proved themselves present for, with
the actuator standing by holding the presses. It is the only test in the
catalog with two ready gates.

The second gate now returns at once. Its setup line still goes up,
because the second half may want the scrap moved, but there is no press
to make.
2026-09-03 18:08:16 -04:00
..