forgectrl pin 47e4256: the airflow floors set from the bench measurement (exhaust 6400, intake 2290, air assist 6000 rpm, purge current 300, grace 15 s) and the operating-point rule: a fan is judged while the laser is armed, when a job's profile may raise it but never lower it below the run duty, or whenever it is commanded at the run duty; the service's hunts, sent with the extraction fans off, are measured and published unjudged. Catalog: cloud.mode-switch now waits out the connect-time hunt sampling /cool/status and requires no AIRFLOW, the exhaust row unjudged and the exhaust actually off; its covers gain forgectrl src/cool.* and src/airflow.*. cooling.fan-gate-trips uses an 8 s test grace (the intakes take 7 s to 90 percent and tripped under the old 2 s at the new floor) and its off leg waits for the row state as well as gates_off. fan_floor_measure.py names a reply that is not JSON and calls the purge readings idle and run (the pump is always on). Docs: COOLING 3a and the settings table, BRINGUP item 19 and a facts-bank entry with the measured fan speeds, the bench README, and a CAMPAIGN-LOG entry for the measurement, the two status-document finds, the hunt find and the hot-deployed bench runs of both tests.