mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-30 10:01:16 -07:00
ws_connect() returns the running WsClient, so gfhome no longer needs to build the client by hand to get a clean disconnect; the exit path uses WsClient.shutdown() to stop and join the socket thread.
215 lines
7.7 KiB
Python
215 lines
7.7 KiB
Python
#!/usr/bin/python3
|
|
"""
|
|
gfhome - one-shot Glowforge web-service homing for ForgeFIRM
|
|
|
|
Connects the machine to the Glowforge web service just long enough for
|
|
the service to run its camera-based homing sequence (settings report ->
|
|
hunt (Z/lens) -> lid image -> move to the home corner -> lid image),
|
|
then parks the lens at the hall-sensor reference, disconnects, and
|
|
exits. All three axes end at the factory home position: X/Y at the
|
|
back-left home corner, Z at the top-of-travel hall trigger.
|
|
|
|
The grblHAL-glowforge controller invokes this for $H when
|
|
homing_mode = gfcloud is set in /data/forgefirm.conf, releasing
|
|
/dev/glowforge for the duration of the run. It can also be run by hand
|
|
(with the controller stopped or its homing session active). The same
|
|
shared config supplies optional identity overrides (gf_serial /
|
|
gf_password; the fuse identity is the fallback), managed from the
|
|
forgectrl UI. The service hostname is always derived from whichever
|
|
serial is in effect - it is never set independently.
|
|
|
|
The service ends the sequence silently - there is no completion
|
|
message - so the run is considered homed once a hunt and at least one
|
|
motion have completed and the service has been quiet for --quiet
|
|
seconds.
|
|
|
|
Exit codes: 0 = homed, 1 = configuration/connection failure,
|
|
2 = homing did not complete.
|
|
|
|
(C) Copyright 2026
|
|
Scott Wiederhold, s.e.wiederhold@gmail.com
|
|
SPDX-License-Identifier: MIT
|
|
"""
|
|
import argparse
|
|
import json
|
|
import logging
|
|
import os
|
|
import queue
|
|
import shutil
|
|
import signal
|
|
import sys
|
|
import time
|
|
from pathlib import Path
|
|
from queue import Queue
|
|
|
|
from gfutilities.configuration import parse, get_cfg, log_level
|
|
from gfutilities.service.authentication import authenticate_machine
|
|
from gfutilities.service.dispatch import dispatch_action, PULS_ACTIONS
|
|
from gfutilities.service.websocket import get_session, ws_connect
|
|
|
|
import ffmachine
|
|
|
|
CONF = '/data/etc/gfhome.conf'
|
|
CONF_SAMPLE = '/etc/gfhome.conf.sample'
|
|
|
|
logging.basicConfig(format='(%(levelname)s) %(module)s:%(funcName)s %(message)s')
|
|
logger = logging.getLogger('openglow')
|
|
|
|
|
|
def load_config(path: str) -> bool:
|
|
if path == CONF and not Path(CONF).is_file() and Path(CONF_SAMPLE).is_file():
|
|
Path(CONF).parent.mkdir(parents=True, exist_ok=True)
|
|
shutil.copyfile(CONF_SAMPLE, CONF)
|
|
if not Path(path).is_file():
|
|
logger.error('config file %s not found', path)
|
|
return False
|
|
parse(path)
|
|
if not get_cfg('SERVICE.SERVER_URL'):
|
|
logger.error('config %s has no SERVICE section', path)
|
|
return False
|
|
if get_cfg('LOGGING.FILE'):
|
|
Path(get_cfg('LOGGING.FILE')).parent.mkdir(parents=True, exist_ok=True)
|
|
fh = logging.FileHandler(get_cfg('LOGGING.FILE'))
|
|
fh.setLevel(log_level(get_cfg('LOGGING.LEVEL')))
|
|
fh.setFormatter(logging.Formatter(
|
|
'%(asctime)s (%(levelname)s) %(module)s:%(funcName)s %(message)s'))
|
|
logger.addHandler(fh)
|
|
logger.setLevel(logging.DEBUG)
|
|
return True
|
|
|
|
|
|
def home(machine, args) -> int:
|
|
q_rx: Queue = Queue()
|
|
q_tx: Queue = Queue()
|
|
|
|
session = get_session()
|
|
if not authenticate_machine(session):
|
|
logger.error('sign-in to %s failed', get_cfg('SERVICE.SERVER_URL'))
|
|
return 1
|
|
|
|
# No session passed: homing is a single short connect that never needs
|
|
# a reconnect token refresh.
|
|
ws = ws_connect(q_rx, q_tx)
|
|
if not ws:
|
|
logger.error('web socket connection failed')
|
|
return 1
|
|
|
|
result = 2
|
|
try:
|
|
machine.start(session, q_tx)
|
|
|
|
from gfhardware._common import InputSwitch
|
|
switches = machine._sw_thread.all_switches()
|
|
if not switches[InputSwitch.SW_DOORS]:
|
|
logger.error('lid is open - close it and re-home')
|
|
return 2
|
|
if not switches[InputSwitch.SW_ESTOP]:
|
|
logger.error('e-stop is tripped')
|
|
return 2
|
|
|
|
t0 = time.monotonic()
|
|
last_activity = t0
|
|
in_flight = ''
|
|
done = set()
|
|
|
|
while True:
|
|
now = time.monotonic()
|
|
if now - t0 > args.timeout:
|
|
logger.error('homing timed out after %ds (completed: %s)',
|
|
args.timeout, sorted(done) or 'nothing')
|
|
return 2
|
|
if 'hunt' not in done and now - t0 > args.start_timeout:
|
|
logger.error('service did not start homing within %ds',
|
|
args.start_timeout)
|
|
return 2
|
|
|
|
busy = bool(machine.running_action_id)
|
|
if busy:
|
|
last_activity = now
|
|
elif in_flight:
|
|
logger.info('%s completed', in_flight)
|
|
done.add(in_flight)
|
|
in_flight = ''
|
|
|
|
if ('hunt' in done and 'motion' in done and not busy
|
|
and now - last_activity >= args.quiet):
|
|
logger.info('homing complete (service quiet %.0fs)', args.quiet)
|
|
result = 0
|
|
break
|
|
|
|
try:
|
|
msg = json.loads(q_rx.get(timeout=0.5))
|
|
except queue.Empty:
|
|
continue
|
|
except ValueError:
|
|
logger.warning('unparseable service message')
|
|
continue
|
|
last_activity = time.monotonic()
|
|
logger.info('service action: %s (%s)',
|
|
msg.get('action_type'), msg.get('status'))
|
|
# Homing borrows the service only for camera homing; a print must
|
|
# never run inside a homing session (allow_print=False).
|
|
result = dispatch_action(machine, msg, allow_print=False)
|
|
if result in PULS_ACTIONS:
|
|
in_flight = result
|
|
finally:
|
|
if result == 0:
|
|
# Deterministic Z: the hunt file leaves the lens wherever its
|
|
# pattern ends; re-reference against the hall sensor so the
|
|
# controller can trust top-of-travel.
|
|
try:
|
|
from gfhardware.z_axis import ZAxis
|
|
ZAxis.home()
|
|
except Exception:
|
|
logger.exception('final Z reference failed')
|
|
result = 2
|
|
ws.shutdown()
|
|
try:
|
|
machine.stop()
|
|
except Exception:
|
|
logger.exception('machine shutdown failed')
|
|
return result
|
|
|
|
|
|
def main() -> int:
|
|
try:
|
|
# The controller exports its own $H budget minus a margin, so
|
|
# the runner always gives up before the controller kills it.
|
|
timeout_default = max(30, int(os.environ.get('GFHOME_TIMEOUT_S', 240)))
|
|
except ValueError:
|
|
timeout_default = 240
|
|
|
|
ap = argparse.ArgumentParser(description='ForgeFIRM one-shot Glowforge cloud homing')
|
|
ap.add_argument('-c', '--config', default=CONF, help='config file (default %s)' % CONF)
|
|
ap.add_argument('--timeout', type=int, default=timeout_default,
|
|
help='overall time budget in seconds (default %d)' % timeout_default)
|
|
ap.add_argument('--start-timeout', type=int, default=120,
|
|
help='max seconds to wait for the service to begin homing (default 120)')
|
|
ap.add_argument('--quiet', type=int, default=10,
|
|
help='silence after the last action that means done (default 10)')
|
|
args = ap.parse_args()
|
|
|
|
signal.signal(signal.SIGTERM, lambda *_: sys.exit(2))
|
|
|
|
if not load_config(args.config):
|
|
return 1
|
|
|
|
ffmachine.apply_identity_overrides()
|
|
|
|
# Machine() reads the OCOTP identity and head info; it fails cleanly
|
|
# when the controller still owns /dev/glowforge.
|
|
try:
|
|
machine = ffmachine.build_machine()
|
|
except Exception:
|
|
logger.exception('machine init failed (is the motion controller '
|
|
'still holding /dev/glowforge?)')
|
|
return 1
|
|
|
|
rc = home(machine, args)
|
|
logger.info('exit %d (%s)', rc, 'homed' if rc == 0 else 'not homed')
|
|
return rc
|
|
|
|
|
|
if __name__ == '__main__':
|
|