The flowload drill in scripts/bench/live_fire_drills.py runs the two tests of the flow-check plan: t1 fires two CW fills on the press with the check at its defaults, t2 fires one fill of a chosen length with the check off, and fit reads rise against dose over the t2 records with the ADC offset steps masked. The sampler adds the heater output, /cool/status is polled at 1 Hz with the fan gates, and every controller reply is kept. The job is fed against the RX buffer's free count, M5 is acknowledged before a run, a run is refused while the window is armed, and M2 is acknowledged and the window's close is waited for. BRINGUP gets item 20: the arm at the first laser-on is skipped while the driver's spindle-state record reads on, the record is not cleared on disarm, and the serial layer drops bytes on a full RX ring, so a job with a lost M5 lets the next job run unarmed. CAMPAIGN-LOG records the Test 1 and Test 2 runs and their numbers. No catalog consequence: a bench drill on the dev image and documentation; no runtime behavior of the release image changes.