forgectrl pin 47e4256: the airflow floors set from the bench measurement (exhaust 6400, intake 2290, air assist 6000 rpm, purge current 300, grace 15 s) and the operating-point rule: a fan is judged while the laser is armed, when a job's profile may raise it but never lower it below the run duty, or whenever it is commanded at the run duty; the service's hunts, sent with the extraction fans off, are measured and published unjudged. Catalog: cloud.mode-switch now waits out the connect-time hunt sampling /cool/status and requires no AIRFLOW, the exhaust row unjudged and the exhaust actually off; its covers gain forgectrl src/cool.* and src/airflow.*. cooling.fan-gate-trips uses an 8 s test grace (the intakes take 7 s to 90 percent and tripped under the old 2 s at the new floor) and its off leg waits for the row state as well as gates_off. fan_floor_measure.py names a reply that is not JSON and calls the purge readings idle and run (the pump is always on). Docs: COOLING 3a and the settings table, BRINGUP item 19 and a facts-bank entry with the measured fan speeds, the bench README, and a CAMPAIGN-LOG entry for the measurement, the two status-document finds, the hunt find and the hot-deployed bench runs of both tests.
forgetest - the ForgeFIRM release acceptance tool
The daemon behind http://<machine>:8090/ on the dev image: runs the
acceptance catalog against the machine, keeps the append-only result log,
decides which results still apply to the image that is running, exports
the release artifact scripts/release.sh gates on, and serves the bench
diagnostics page. The contract - catalog, campaigns, fingerprints,
inheritance, the gate, the coverage rule - is
docs/ACCEPTANCE.md.
Run the host tests
cd forgetest
python3 -m unittest discover -s tests -v
Run the daemon on a workstation (against a mock or a manifest file)
FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine>:8080 python3 -m forgetest --port 8090
scripts/manifest-from-tree.py produces tree-manifest.json from the recipe
pins; the coverage lint is python3 -m forgetest.coverage --manifest ....
Environment
| Variable | Default | Purpose |
|---|---|---|
FORGETEST_DATA |
/data/forgetest |
results.jsonl, bench.jsonl, token, export/ |
FORGETEST_MANIFEST |
/etc/forgefirm-manifest.json |
the image manifest |
FORGETEST_PORT, FORGETEST_HOST |
8090, 0.0.0.0 | listener |
FORGETEST_BENCH_DIR |
/usr/share/forgetest/bench |
the installed bench scripts |
FORGETEST_BENCH_DATA |
<FORGETEST_DATA>/bench |
passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN) |
FORGETEST_MARKER |
/run/forgetest.active |
takeover marker |
FORGECTRL_URL, FORGECTRL_TOKEN_FILE |
http://127.0.0.1:8080, /data/forgefirm/panel.token |
forgectrl client |
GF_SYSFS_ROOT |
/sys/glowforge/ |
kernel module sysfs |
GRBL_HOST, GRBL_PORT |
127.0.0.1, 23 | Grbl TCP |
Adding a test
Register it in the subsystem module under forgetest/suite/ with
@test(...): id subsystem.name, kind, hardware, mode (the controller
mode the test needs; the runner switches to it first), covers,
requires, always, steps. The body gets a Context (log, check, fail,
prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs,
grbl, takeover). Return normally for PASS, raise runner.Failed for
FAIL. Then run the unit tests and the coverage lint.