ScottW514 520d62ac05 forgetest tests: the confirmed trims of the tool's own unit tests
The cases that tested a mock, a timer, a wording or a table, or that
replayed a judgment a host test already holds, leave forgetest/tests.
What catches a false PASS, keeps the bench safe, or guards the gate
stays.

- test_baseline: the fake sysfs tree is a mixin with no test_ methods,
  so ExtensionFreeTests and BaselineModeTests no longer re-run
  BaselineTests' 25 cases (133 runs, now 45). CoolPublishTests, the
  lamp-fade cases and TransientNotLeftoverTests go; PositionDeadbandTests
  keeps a reading past the band and an unreadable reading, both never
  excused. Both latch-relock cases stay.
- test_fixture: MdnsTests, the three timing cases, the probe's log
  wording, and nine prompt-routing variants go. A live test never runs
  unattended, the arm-press opt-in, the short-press edge, the presence
  press handing over the arm press, and the arm notice dropping at the
  press stay (35 cases, now 21).
- test_cloud_suite: three false-PASS guards stay: the latch open at a
  dark print's button, a lid stop that is not edge-driven, the kernel
  refusing the resume. The guards for the latch unlocking in the hold
  and a paused print resuming left with their catalog tests in 6a434bb.
  The rest go, with the harness pieces and the hunt-lid fixture only
  they read (41 cases, now 3).
- test_cooling_suite: GateOffTests, CriticalTierTests, FanGateTests and
  FansQuietTests go with their harness; the flow verdict's log reads
  stay: only the text after the offset, never an older verdict before it
  (the flow-under-load false-PASS guard), a rotated log read whole.
- test_queue: RunClockTests and three ordering cases go, and refusals
  are judged by a reason given, not its words; both live
  acknowledgment cases stay.
- test_takeover_position: the six cases that judge the head and move
  nothing stay.
- test_camera_home_return: the five cases where the head must not move
  stay, and so do the three that check the hand-back jog's direction and
  distance (homed, unhomed with the counters not counted twice, after
  cloud mode): a wrong sign or a double count drives the head into the
  gantry stops (15 cases, now 8).
- test_server: the keep-alive and ETag cases, the takeover and scope
  half of the bench case, and the page's self-contained asserts
  (test_page.py's) go.
- test_operator: the wording cases, the fixture case (test_fixture.py's)
  and JournalTests go.
- test_mode: the supervisor timeout table goes.
- test_takeover_client: the listener, the offline service back, the
  online client without the hunt, and GRBL under no marker stay.
- test_responsiveness: PageTests and ImplementationCostTests go; the
  log cache keeps appends, a partial line, a replaced file and a fresh
  list, and the fingerprint cache a changed manifest and one with no
  content hash.
- test_bench_registry: GfbenchTests and two description and argument
  pins go.
- test_installer: the log-format and TLS-wording cases and
  InstallerShapeTests go; the die case checks the reason is in the log,
  not its format.
- test_image: KernelIdentTests and the registration pin go.

Each file's __main__ guard now ends the file, and the docstrings say what
each still proves.

Proof: each of the fifteen files passes under Linux as forgetest-ci
discovers it, and pyflakes reports nothing new in them.

Acceptance: none; test-only.
2026-10-13 20:29:25 -04:00
..
2026-09-18 12:14:22 -04:00

forgetest - the ForgeFIRM release acceptance tool

The daemon behind http://<machine>:8090/ on the dev image: runs the acceptance catalog against the machine, keeps the append-only result log, decides which results still apply to the image that is running, exports the release artifact scripts/release.sh gates on, and serves the bench diagnostics page. The contract - catalog, campaigns, fingerprints, inheritance, the gate, the coverage rule - is the Acceptance page of the documentation site.

Run the host tests

cd forgetest
python3 -m unittest discover -s tests -v

Run the daemon on a workstation (against a mock or a manifest file)

FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine> python3 -m forgetest --port 8090

scripts/manifest-from-tree.py produces tree-manifest.json from the recipe pins; the coverage lint is python3 -m forgetest.coverage --manifest ....

Environment

Variable Default Purpose
FORGETEST_DATA /data/forgetest results.jsonl, bench.jsonl, token, export/
FORGETEST_MANIFEST /etc/forgefirm-manifest.json the image manifest
FORGETEST_PORT, FORGETEST_HOST 8090, 0.0.0.0 listener
FORGETEST_BENCH_DIR /usr/share/forgetest/bench the installed bench scripts
FORGETEST_BENCH_DATA <FORGETEST_DATA>/bench passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN)
FORGETEST_MARKER /run/forgetest.active takeover marker
FORGECTRL_URL, FORGECTRL_TOKEN_FILE http://127.0.0.1, /data/forgefirm/panel.token forgectrl client (HTTP; the token authorizes writes from the board)
FORGECTRL_TLS_URL https://127.0.0.1 forgectrl over HTTPS (self-signed, unverified), for the login test
GF_SYSFS_ROOT /sys/glowforge/ kernel module sysfs
GRBL_HOST, GRBL_PORT 127.0.0.1, 23 Grbl TCP

Adding a test

Register it in the subsystem module under forgetest/suite/ with @test(...): id subsystem.name, kind, hardware, mode (the controller mode the test needs; the runner switches to it first), covers, requires, always, steps. The body gets a Context (log, check, fail, prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs, grbl, takeover). Return normally for PASS, raise runner.Failed for FAIL. Then run the unit tests and the coverage lint.