forgectrl 0.1.24 = 2380e07: every fan duty write is read back and retried, a duty a device lost is put back by the tick, and the airflow fault names the duty commanded and the duty in force. The corner card of the sheet on the bench reference was held as a slow air-assist fan after a run-duty write the head never took; nothing checked. Acceptance: cooling.fan-duty-readback (auto, grbl) opens an M8 session, reads every fan's run duty back, writes the head's air-assist register back to the idle duty and the exhaust PWM to zero behind the engine's back, and holds both to their run duties again within a few ticks, each loss named in the log, the session OK to its end, the idle duties after M9. Covers the head driver too. On the bench reference with forgectrl 0.1.24 hot-deployed it PASSED: both duties back after 0.5 s.
forgetest - the ForgeFIRM release acceptance tool
The daemon behind http://<machine>:8090/ on the dev image: runs the
acceptance catalog against the machine, keeps the append-only result log,
decides which results still apply to the image that is running, exports
the release artifact scripts/release.sh gates on, and serves the bench
diagnostics page. The contract - catalog, campaigns, fingerprints,
inheritance, the gate, the coverage rule - is
the Acceptance page of the documentation site.
Run the host tests
cd forgetest
python3 -m unittest discover -s tests -v
Run the daemon on a workstation (against a mock or a manifest file)
FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine> python3 -m forgetest --port 8090
scripts/manifest-from-tree.py produces tree-manifest.json from the recipe
pins; the coverage lint is python3 -m forgetest.coverage --manifest ....
Environment
| Variable | Default | Purpose |
|---|---|---|
FORGETEST_DATA |
/data/forgetest |
results.jsonl, bench.jsonl, token, export/ |
FORGETEST_MANIFEST |
/etc/forgefirm-manifest.json |
the image manifest |
FORGETEST_PORT, FORGETEST_HOST |
8090, 0.0.0.0 | listener |
FORGETEST_BENCH_DIR |
/usr/share/forgetest/bench |
the installed bench scripts |
FORGETEST_BENCH_DATA |
<FORGETEST_DATA>/bench |
passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN) |
FORGETEST_MARKER |
/run/forgetest.active |
takeover marker |
FORGECTRL_URL, FORGECTRL_TOKEN_FILE |
http://127.0.0.1, /data/forgefirm/panel.token |
forgectrl client (HTTP; the token authorizes writes from the board) |
FORGECTRL_TLS_URL |
https://127.0.0.1 |
forgectrl over HTTPS (self-signed, unverified), for the login test |
GF_SYSFS_ROOT |
/sys/glowforge/ |
kernel module sysfs |
GRBL_HOST, GRBL_PORT |
127.0.0.1, 23 | Grbl TCP |
Adding a test
Register it in the subsystem module under forgetest/suite/ with
@test(...): id subsystem.name, kind, hardware, mode (the controller
mode the test needs; the runner switches to it first), covers,
requires, always, steps. The body gets a Context (log, check, fail,
prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs,
grbl, takeover). Return normally for PASS, raise runner.Failed for