Files
forgefirm/forgetest/forgetest/bench.py
T
ScottW514 965f7c3ca9 The cooling report secret: a driver harness, and two catalog tests
forgectrl's POST /cool/state now asks for the secret the supervisor hands
the running controller at its spawn; both controllers' cooling clients
send it.

scripts/bench/cool_report_test.py is the driver's host harness for it
(null-sink controller, a stand-in for forgectrl's listener on
FORGECTRL_PORT): every report carries the secret and no other new header;
none does when there is none; a value that is not 32 hex digits, a CR LF
with a header behind it included, never reaches the wire; the homing
runner the controller starts does not inherit the secret. It is in the
bench registry and the bench README, and the driver's CI runs it.

forgectrl.auth: the loopback case used to assert that any local peer is
accepted. It now asserts the three answers: no secret 403, a made-up
secret 403, and the running controller's own secret 200, read as only root
on the machine can read it, out of the controller's environment, and never
logged. The LAN cases carry the secret too and are still refused.

cooling.report-channel is new, the drill the change exists for: M8 opens a
run session, three forged idle reports from this host (no secret, a
made-up one, a made-up one with a forged Host) are each refused, and over
the next five seconds the engine stays in phase run and no commanded fan
duty drops; M9 ends the session on the controller's own report.

Proven. The harness passes on the host-built controller, with three
negative controls that each fail as they should. The unit suite passes
(421) with no undefined name. On the bench reference, forgectrl and both
clients hot-deployed over image 20260920152153: forgectrl.auth PASS,
cooling.report-channel PASS (phase run throughout, the exhaust at 65535 and
the intake at 43278), and cooling.fans-quiet-after-motion and motion.job
PASS on the same binaries.

Acceptance. forgectrl.auth and cooling.report-channel are the gate for the
report channel's secret; cloud.dark-print gates the cloud client's side.
2026-09-20 16:46:01 -04:00

426 lines
31 KiB
Python

# Copyright 2026 514 LLC d/b/a OpenGlow
# Written by Scott Wiederhold
# https://community.openglow.org
# SPDX-License-Identifier: MIT
"""The bench diagnostics page: registry of the bench tools and the
subprocess runner behind the #bench tab.
The registry lists every tool of scripts/bench (the README is the human
index; this is the machine one) with its safety class and argument spec.
A tool is runnable from the page once `ported` is set: the script is
installed under the tool directory (/usr/share/forgetest/bench on the
image, override FORGETEST_BENCH_DIR) and runs as a subprocess with the
form's arguments, output streamed to the page. Unported tools are listed
so the catalog of what exists is complete, with Start disabled.
Safety classes:
dry reads or dry motion, no emission, forgectrl stays up
takeover needs forgectrl stopped and the pulse device free
scope a takeover whose result only means something with the named
instrument on the bench (a scope on LASER_PWM / LASER_ON)
live laser emission possible (operator acknowledgment required)
The tools that also run from a LAN host (gfbench.py: GF_HOST) run on the
board here with GF_HOST=127.0.0.1, the panel token in GF_TOKEN, and
their data files under FORGETEST_BENCH_DATA (<data>/bench/). Bench runs
are recorded in <data>/bench.jsonl and never enter a campaign.
"""
import json
import os
import shlex
import sys
import threading
from .log import data_dir, now_ts
DEFAULT_TOOL_DIR = "/usr/share/forgetest/bench"
def _arg(name, type="str", default=None, help="", choices=None, flag=None):
"""One form field. `flag` names the option the value is passed as
(--feed 600); without it the value is positional, in registry order."""
a = {"name": name, "type": type, "default": default, "help": help}
if choices:
a["choices"] = list(choices)
if flag:
a["flag"] = flag
return a
TOOLS = [
# -- board-side, dry ------------------------------------------------------
{"id": "check-pwm", "title": "Laser PWM register check", "script": "check_pwm.py",
"safety": "dry", "where": "board", "ported": True, "args": [],
"desc": "Reads PWM2 PWMCR/PWMPR via /dev/mem; expects divider 13 x ~127 counts = ~40 kHz. Read-only."},
{"id": "pacing-test", "title": "Protocol-loop pacing check", "script": "pacing_test.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("mm", "float", 30.0, "jog distance (+X first)"), _arg("feed", "float", 600.0, "feed rate")],
"desc": "Dry motion: idle/parked states coarse-paced, active motion tight-paced, hold/resume mid-move keeps position."},
{"id": "bench-m2", "title": "Motion-quality bench", "script": "bench_m2.py",
"safety": "dry", "where": "board", "ported": True, "args": [],
"argv_fixed": ["127.0.0.1"],
"desc": "Bounded round-trip jogs (sanity, max-rate, diagonal) + feed-hold/resume; reports peak feed, transitions, drift."},
{"id": "bench-phase2", "title": "End-of-data protocol bench", "script": "bench_phase2.py",
"safety": "takeover", "where": "board", "ported": True, "args": [],
"desc": "Underrun detection/ack, parked no-replay guard, resume(0), continuous feed, run/underrun cycles. Motors locked, laser latched."},
{"id": "cp-watchdog", "title": "HV charge-pump watchdog timing", "script": "cp_watchdog_timing.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("duration_s", "float", 14.0, "capture length")],
"desc": "Latches CHG_PUMP feed pulses, polls the watchdog readbacks while commanding short local jogs. Motion only, laser locked."},
{"id": "accel-fast", "title": "Head accelerometer sampler", "script": "accel_fast.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("duration_s", "float", 5.0, "capture length"),
_arg("jog1", "str", None, "optional mid-capture jog, e.g. $J=G91X20F2400"),
_arg("jog2", "str", None, "optional second jog")],
"desc": "Direct-I2C sampler for the head-bus LIS2HH12s with optional mid-capture jogs. CSV to /tmp/accel.csv."},
{"id": "bump-seek", "title": "Accelerometer bump-seek homing prototype", "script": "bump_seek.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("direction", "choice", "-", "X direction", ["-", "+"]),
_arg("feed", "int", 120, "creep feed"), _arg("segment_mm", "float", 15.0, "jog segment"),
_arg("max_mm", "float", 200.0, "travel bound")],
"desc": "Creeps toward a rail in bounded jog segments, detects the contact jolt, jog-cancels and backs off."},
{"id": "accel-crash-probe", "title": "Head accel crash-detector probe", "script": "accel_crash_probe.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("seconds", "float", 20.0, "arm-and-watch window"),
_arg("mode", "choice", "coexist", "coexist keeps st_accel bound (forgectrl up); unbind frees it",
["coexist", "unbind"], flag="--mode"),
_arg("ths", "int", 40, "per-axis threshold register value 0..255", flag="--ths"),
_arg("dur", "int", 0, "IG_DUR1 duration counter (ODR samples)", flag="--dur"),
_arg("axes", "str", "xyz", "axes to arm for high events", flag="--axes"),
_arg("jog", "str", None, "optional one jog at t=2 s, e.g. $J=G91X5F1000 (+X only)", flag="--jog")],
"desc": "Arms the head LIS2HH12's on-chip interrupt generator (IG1) and polls IG_SRC1 for a latched strike. "
"coexist mode reaches the IG registers over i2c-dev with st_accel still bound (the forgectrl-only "
"path proof); provoke a trip by hand or with --jog. Touches the IG registers and CTRL1 "
"(saved, run at 800 Hz, restored; the IG only samples at a running ODR), no emission, "
"no full-scale change. CSV to /tmp/accel_crash.csv."},
# -- board-side, takeover / scope ------------------------------------------
{"id": "pwm-sweep", "title": "LASER_PWM scope sweep", "script": "pwm_sweep.py",
"safety": "scope", "where": "board", "ported": True,
"args": [_arg("mode", "choice", "check", "check = read-only, sweep = duty staircase", ["check", "sweep"])],
"desc": "check: readbacks + PWM2 dump; sweep: PWMSAR through 50/25/75/6/100 percent with 4 s holds. "
"Locked state (the takeover): latch relocked, refuses if FIRE or LASER_ON reads active."},
{"id": "pwm-hold", "title": "LASER_PWM scope hold", "script": "pwm_hold.py",
"safety": "scope", "where": "board", "ported": True,
"args": [_arg("sar", "int", 64, "PWMSAR value"), _arg("seconds", "int", 10, "hold time")],
"desc": "Holds one PWMSAR value for a scope window, then restores. Locked state (the takeover): "
"latch relocked, refuses if FIRE or LASER_ON reads active."},
{"id": "fire-test", "title": "FIRE drop-timing test (A/B/U)", "script": "fire_test.py",
"safety": "takeover", "where": "board", "ported": True,
"args": [_arg("mode", "choice", "A", "A latch locked, B unlocked/unarmed, U true underrun", ["A", "B", "U"])],
"desc": "Duty 0 throughout; refuses to unlock if HV reports good. Software witnesses + the PSU-connector LASER_ON scope point."},
{"id": "pwm-stream", "title": "LASER_PWM stream-path test", "script": "pwm_stream_test.py",
"safety": "takeover", "where": "board", "ported": True, "args": [],
"desc": "Streams power bytes only (no steps, no FIRE, motor_lock=15, latch locked) through /dev/glowforge; "
"PASS = counters unmoved, idle at the end, no FIRE/emission read back. The scope on LASER_PWM sees the duty steps."},
{"id": "gate-a-kernel", "title": "Kernel laser-safety drills K1/K2/K3", "script": "gate_a_kernel_drills.py",
"safety": "takeover", "where": "board", "ported": True,
"args": [_arg("drill", "choice", "K1", "K1 stop floor, K2 resume honors latch, K3 mid-ramp unlock", ["K1", "K2", "K3"])],
"desc": "Software witnesses (cnc/state, laser_enable, laser_on, interlock bit 3); K3 refuses if HV reports good."},
{"id": "platform-drills", "title": "Kernel platform drills", "script": "platform_drills.py",
"safety": "takeover", "where": "board", "ported": True,
"args": [_arg("drill", "choice", "decay", "deadman / rmmod / decay / led / all",
["deadman", "rmmod", "decay", "led", "all"])],
"desc": "Dead-man trip readback, rmmod/modprobe cycles under load, decay/microstep readback, LED sequence."},
# -- cooling ------------------------------------------------------------------
{"id": "flow-confirm", "title": "Coolant flow suspicion/confirmation drill", "script": "flow_confirm_drill.py",
"safety": "dry", "where": "board", "ported": True, "args": [],
"desc": "One M8 session walks the verdict state machine through real pump-off transients; PASS/FAIL per transition."},
{"id": "flow-escalate", "title": "Coolant starved re-check escalation drill", "script": "flow_escalate_drill.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("budget_s", "int", 60, "cool_confirm_max_s for the drill (60-3600), restored after")],
"desc": "With the pump off the job-start check reads SUSPECT and the engine must escalate to FAULT when "
"the confirmation budget expires; the budget setting is shortened for the drill and restored."},
{"id": "flow-characterize", "title": "Coolant flow characterization", "script": "flow_characterize.py",
"safety": "takeover", "where": "board", "ported": True,
"args": [_arg("duty", "int", 30, "heater duty percent")],
"desc": "Baseline -> flow -> no-flow -> recovery with the factory temperature curve; aborts past 45 C "
"downstream. Drives the heater and pump directly (about 9 minutes)."},
{"id": "flow-sustained", "title": "Coolant sustained re-check run", "script": "flow_sustained.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("minutes", "float", 30.0, "how long to hold M8")],
"desc": "Long run of the real re-check cadence via M8: verdicts, false faults, loop heat accumulation."},
{"id": "flow-warm", "title": "Coolant warm-baseline validation", "script": "flow_warm_validate.py",
"safety": "takeover", "where": "board", "ported": True,
"args": [_arg("cycles", "int", 3, "cycles per case (flow / no-flow)"),
_arg("target_c", "float", 28.0, "warm the upstream sensor to this before each check"),
_arg("warm_min", "float", 20.0, "warm-up budget per check, minutes")],
"desc": "Runs the real check (40 percent / 50 s, cut-profile fans) from a heater-warmed baseline, alternating "
"flow and no-flow; results to the bench data directory. Slow: about 15 minutes per cycle."},
{"id": "offset-probe", "title": "Coolant-sensor offset probe", "script": "offset_probe.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("mode", "choice", "survey", "survey: one actuator at a time; ladder: the air-assist "
"duty ladder; jog: the air assist at run duty while the gantry jogs",
["survey", "ladder", "jog"])],
"desc": "Which actuator moves both coolant thermistors together? Switches the exhaust (100/50/25 "
"percent), intakes, air assist, purge, heater, pump, TEC and lid lamp one at a time, dark, "
"with both sensors at 25 Hz, and scores the common-mode step at every edge and the level "
"toggling inside every dwell; every value is restored on exit. The pump stops once for "
"8 s with the tube dark and the heater off. About five minutes."},
{"id": "aa-offset-check", "title": "Coolant offset correction under the run airflow", "script": "aa_offset_check.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("dwell", "float", 20.0, "seconds to read under the run profile")],
"desc": "M8 brings the fans to the run profile (no laser-on, no press) while the raw coolant "
"counts, /status and the engine's readings are averaged before, during and after: with "
"cool_aa_offset_counts at the machine's value the readings hold still while the raw counts "
"step; at zero they drop by about a degree. About a minute."},
{"id": "critical-tier", "title": "Coolant critical-tier warm-loop drill", "script": "critical_tier_drill.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("max_seconds", "int", 1200, "give up after this long without CRITICAL", flag="--max-seconds")],
"desc": "Sets the ceiling, the resume gate and the critical line a few tenths above the live upstream "
"reading and lets the engine's own flow-check heater warm the loop through them inside one M8 "
"session: OVERTEMP at the ceiling, then CRITICAL (fire blocked, hold, no resume), the fault ending "
"with the session; settings restored and re-read. Results to the bench data directory."},
{"id": "flow-recheck", "title": "Coolant re-check characterization", "script": "flow_recheck_char.py",
"safety": "takeover", "where": "board", "ported": True,
"args": [_arg("heater_pct", "int", 50, "heater duty percent"), _arg("window_s", "int", 30, "re-check window")],
"desc": "Short in-run re-checks and the differential metric, flow vs no-flow from a settled loop; "
"aborts past 45 C downstream (about 5 minutes)."},
{"id": "flow-matrix", "title": "Coolant flow-detection design matrix", "script": "flow_matrix.py",
"safety": "takeover", "where": "board", "ported": True,
"args": [_arg("duties", "str", "10,15,20,30,40,50", "heater duties, percent, comma-separated"),
_arg("repeats", "int", 5, "interleaved repeats per case")],
"desc": "duty x flow/no-flow x repeats from a common cooled baseline; cost and precision tables and a "
"ranked shortlist (the derivation of cool_flow_rise). Very slow: about 1.6 h for the full matrix; "
"resumable from the results file in the bench data directory."},
{"id": "flow-sampler", "title": "Coolant sampler", "script": "flow_sampler.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("duration_s", "int", 30, "capture length"), _arg("interval_s", "float", 1.0, "sample interval")],
"desc": "Prints elapsed,raw_down,raw_up at the interval; the sampler behind the flow tools."},
{"id": "temp-calibrate", "title": "Coolant temperature spot-check", "script": "temp_calibrate.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("mode", "choice", "watch", "coolant: watch / point / fit; supply (pic/pwr_temp): "
"supply-watch / supply-point / supply-fit",
["watch", "point", "fit", "supply-watch", "supply-point", "supply-fit"]),
_arg("value", "str", None, "point: the thermometer reading in C; watch: seconds (default 60)")],
"desc": "Pairs a measured temperature with averaged raw readings; fits a per-machine line. The coolant "
"sensors, or the power supply's (thermometer on its heatsink, against the documented unverified "
"guess). Points accumulate in the bench data directory."},
{"id": "fan-test", "title": "Fan/coolant bench", "script": "fan_test.py",
"safety": "dry", "where": "board", "ported": True, "args": [],
"desc": "Snapshots fan PWMs/tachs/temps, drives M8 -> cut fans, M9 -> cooldown -> idle; the tach "
"readbacks in each snapshot are the evidence."},
{"id": "fan-floor", "title": "Fan floor measurement", "script": "fan_floor_measure.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("mode", "choice", "spinup", "spinup (M8, from idle) / cut (sample only, during a real cut)",
["spinup", "cut"]),
_arg("seconds", "int", 120, "sampling window", flag="--seconds"),
_arg("steady", "int", 60, "spinup: the steady window at the end", flag="--steady")],
"desc": "The numbers the airflow gates ship with: per fan the steady speed at run duty, the time to "
"90 percent and the spread, the purge current off and on, and (cut) the spread under a real "
"cut; results to the bench data directory."},
# -- laser (live) --------------------------------------------------------------
{"id": "live-fire", "title": "LIVE laser drills", "script": "live_fire_drills.py",
"safety": "live", "where": "board", "ported": True,
"args": [_arg("drill", "choice", "witness", "witness / hold / ircut / expstop / ctrlstart",
["witness", "hold", "ircut", "expstop", "ctrlstart"]),
_arg("power", "int", 1000, "ircut: S value"), _arg("feed", "int", 300, "ircut: F value")],
"desc": "Emission witness, disarm grace in Hold, lid-IR characterization cut, armed "
"kill on the expected-stop path (+ the separate controller restart). The operator's arm press is "
"required for every drill; eye protection, fire watch, extinguisher, exhaust."},
{"id": "resume-dark-lead", "title": "Pause / resume chain timing (dark lead)", "script": "resume_dark_lead.py",
"safety": "live", "where": "board", "ported": True,
"args": [_arg("run", "choice", "dry", "dry travel, or LIVE FIRE", ["dry", "live"], flag="--run"),
_arg("mode", "choice", "m3", "laser mode for a live run", ["m3", "m4"], flag="--mode"),
_arg("power", "int", 400, "live: S value", flag="--power"),
_arg("feed", "float", 600.0, "feed rate", flag="--feed"),
_arg("len", "float", 60.0, "move length in mm (+X)", flag="--len"),
_arg("passes", "int", 1, "alternating +X/-X moves", flag="--passes"),
_arg("secs", "float", 45.0, "sampling window", flag="--secs"),
_arg("auto", "str", "", "dry only: 'P,R' seconds to send ! and ~ unattended", flag="--auto")],
"desc": "Samples LASER_ON, FIRE, HV_ENABLE and the charge-pump watchdog straight off the SoC pads "
"across a pause and a resume, with motion dated from the kernel counters: how long HV survives "
"a pause, how fast the chain re-arms, and - on a live run - the dark lead between FIRE and "
"LASER_ON that a resumed cut loses. Dry by default; --run live needs the arm press, eye "
"protection, fire watch, extinguisher, exhaust."},
{"id": "pgood-probe", "title": "Supply power-good line against the chain", "script": "pgood_probe.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("secs", "float", 90.0, "sampling window", flag="--secs")],
"desc": "Watches the supply's power-good line (cnc/laser_pgood, reported as the raw pin level) beside "
"LASER_ON, FIRE, the charge-pump watchdog, HV_ENABLE and the doors through the kernel readbacks at a "
"few hundred hertz, with hv_current at 20 Hz, and prints every transition. It only watches: drive "
"the machine meanwhile (a jog, an armed cut, a pause, a lid open). Needs no pad mapping."},
# -- host-side harnesses (CI) ------------------------------------------------------
{"id": "laser-stream-test", "title": "Laser pulse-stream emission harness", "script": "laser_stream_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "Null-sink controller stream capture against the feeder contract. A CI harness (the grblHAL repo): "
"it needs the host-built null-sink controller, not the machine, so it is not a bench-page tool."},
{"id": "laser-lifecycle-test", "title": "Armed-window lifecycle harness", "script": "laser_lifecycle_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "Arm/disarm lifecycle on the null-sink controller. A CI harness (the grblHAL repo): needs the "
"host-built null-sink controller, not the machine, so it is not a bench-page tool."},
{"id": "z-envelope-test", "title": "Z envelope harness", "script": "z_envelope_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "The Z soft limit belongs to the driver, not to $20: an unreferenced Z is collapsed to where the "
"lens stands, and neither a $20 nor a $132 write frees it. A referenced lens (forgectrl's marker "
"and the lens settings) opens it to the window the settings hold, the fallback or the focus "
"card's stops: the ends of the reach run, two half-steps past either end alarms. A CI harness "
"(the grblHAL repo): needs the host-built null-sink controller, not the machine, so it is not a "
"bench-page tool."},
{"id": "ctlport-test", "title": "Controller port and line multiplexer harness", "script": "ctlport_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "A scripted sender that counts every response, beside the controller port's one client, on the "
"null-sink controller: a port jog's status goes to the port and never to the sender, a port "
"error does not reach the sender's parser, a sender line cancels a port jog and gets its own ok "
"(a line queued right behind the port's included), the refusals, the single client, a CR LF "
"sender, a soft reset, and the client as the dead-man. A CI harness (the grblHAL repo): needs "
"the host-built null-sink controller, not the machine, so it is not a bench-page tool."},
{"id": "cool-report-test", "title": "Cooling report secret harness", "script": "cool_report_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "The controller's cooling reports on the null-sink controller, read by a stand-in for "
"forgectrl's listener: every report carries the secret the supervisor hands the controller at "
"its spawn (GF_REPORT_SECRET), none does when there is none, a value that is not 32 hex digits "
"(a CR LF with a header behind it included) never reaches the wire, and the homing runner the "
"controller starts does not inherit it. A CI harness (the grblHAL repo): needs the host-built "
"null-sink controller, not the machine, so it is not a bench-page tool."},
{"id": "manual-home-test", "title": "Manual home and motor release harness", "script": "manual_home_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "The manual homing provider and the motor release on the null-sink controller: $H under manual "
"ships nothing and declares X0 Y0 with the soft limits on and Z kept; while the motors are "
"released every motion source is refused and ships nothing, $X and a soft reset do not unlock "
"it, and only $ME and a manual $H write the energize, once each; the port's panel operations "
"do the same with the sender's count exact. Imports its sender and port client from "
"ctlport_test.py. A CI harness (the grblHAL repo): needs the host-built null-sink controller, "
"not the machine, so it is not a bench-page tool."},
{"id": "raster-dry", "title": "Dry top-speed raster per XY microstep mode", "script": "raster_dry.py",
"safety": "dry", "where": "board", "ported": True,
"args": [_arg("modes", "choice", "8 16 32", "the modes to run, in order", ["8", "16", "32", "8 16 32"])],
"desc": "For each mode given: stores xy_microsteps, waits for the restarted controller, streams a 60-pass "
"raster of 150 mm at F12000 with the laser off, and reports the peak feed, the controller CPU, the "
"kernel counters against the start, underruns and clamped events. Needs the head with 150 mm of "
"free +X and 12 mm of free +Y travel, no other Grbl client. Ends at x8."},
{"id": "xy-pattern-accel", "title": "XY microstep modes by the head accelerometer, the machine silent",
"script": "xy_pattern_accel.py", "safety": "dry", "where": "board", "ported": True,
"args": [_arg("modes", "choice", "8 16 32", "the modes to run, in order", ["8", "16", "32", "8 16 32"])],
"desc": "From home at F12000: to (18, 9) in, to (9, 9) in, a 9 in circle from its mid-bottom back to "
"(9, 9), to (9, 0), home. Per mode: every fan, the coolant pump and the TEC commanded off through "
"the engine's quiet hold (the machine silent, the modes audible), the fixed 10 s wait, the head "
"accelerometer sampled over the bus at 800 Hz through the pattern; "
"cruise-window RMS and peak-to-peak per leg and overall, the kernel counters against home, "
"underruns; JSON with the trace to the bench data directory. Needs the machine homed and at home, "
"the lid closed, no other Grbl client, the bed clear. Ends at x8."},
{"id": "arc-tolerance-sweep", "title": "How fine an arc the controller can plan ($12 ladder)",
"script": "arc_tolerance_sweep.py", "safety": "dry", "where": "board", "ported": True,
"args": [_arg("mode", "choice", "16", "the XY microstep mode", ["8", "16", "32"], flag="--mode"),
_arg("ladder", "str", "0.002 0.001 0.0005 0.00025 0.0001", "the $12 values to try, in order")],
"desc": "From home, the machine silent: to (9, 9) in, then the 9 in circle at F12000 once per $12 in the "
"ladder. Per rung: the chords and boundaries a second, the circle time against the ideal, the lowest "
"feed mid-circle, the fewest free planner blocks, the controller CPU, clamped events, underruns, the "
"accelerometer's cruise RMS. $12 goes back to what it was; the head returns home. Needs the machine "
"homed and at home, the lid closed, no other Grbl client."},
{"id": "planner-blocks-test", "title": "Planner buffer depth harness", "script": "planner_blocks_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "A deep planner buffer starts: the controller restarted at $398=400 and at $398=1000 answers "
"on the port, reports the depth in its status report and runs a move. A CI harness (the grblHAL "
"repo): needs the host-built null-sink controller, not the machine, so it is not a bench-page tool."},
{"id": "xy-mode-test", "title": "XY microstep mode harness", "script": "xy_mode_test.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "The XY scale is the microstep mode's, never typed: xy_microsteps sets $100/$101 and the "
"machine tick, a typed $100 is overwritten, and $110/$111 are held under a lowered tick. A CI "
"harness (the grblHAL repo): needs the host-built null-sink controller, not the machine, so it "
"is not a bench-page tool."},
{"id": "puls-profile", "title": "Factory .puls profile decoder", "script": "puls_profile.py",
"safety": "dry", "where": "host", "ported": False, "args": [],
"desc": "Decodes factory pulse streams into velocity/accel profiles. Runs anywhere; needs a .puls file "
"(the reference captures live off the machine), so it is not a bench-page tool."},
{"id": "debug-kernel-drills", "title": "Debug-kernel lock drills (load/unload, forced defer)",
"script": "debug_kernel_drills.py",
"safety": "takeover", "where": "board", "ported": True, "args": [],
"desc": "Runs only on the debug-kernel image (kas/forgefirm-glowforge-debug.yml): three glowforge.ko "
"load/unload cycles under DEBUG_MUTEXES and a forced -EPROBE_DEFER unwind, each read against "
"dmesg for lock splats. Cycles the 40 V rail; refuses on a non-debug kernel or a non-idle machine."},
]
# Files in scripts/bench the page never offers: the helper module the
# host/board tools share (the C feeder and the build scripts are not
# python), and the two lens stall drills. A stall slips the lens stepper's
# rotor under full torque, so those run from the shell on the bench
# reference machine only (scripts/bench/README.md).
NOT_TOOLS = ("gfbench.py", "lens_travel.py", "lens_stop_accel.py")
class Bench:
def __init__(self, tools=None, tool_dir=None, index_path=None):
self.tools = list(tools if tools is not None else TOOLS)
self._by_id = {t["id"]: t for t in self.tools}
self._tool_dir = tool_dir
self.index_path = index_path or os.path.join(data_dir(), "bench.jsonl")
self._lock = threading.Lock()
def tool_dir(self):
return self._tool_dir or os.environ.get("FORGETEST_BENCH_DIR") or DEFAULT_TOOL_DIR
def get(self, tool_id):
return self._by_id.get(tool_id)
def command(self, tool, args):
"""argv for a tool with the form's arguments. Returns
(ok, argv, error)."""
script = os.path.join(self.tool_dir(), tool["script"])
if not os.path.exists(script):
return False, None, "script not installed: %s" % tool["script"]
argv = [sys.executable, script] + list(tool.get("argv_fixed", []))
for spec in tool.get("args", []):
raw = args.get(spec["name"], spec.get("default"))
if raw is None or raw == "":
if spec.get("default") in (None, ""):
continue # optional and absent: not passed at all
raw = spec["default"]
try:
if spec["type"] == "int":
val = str(int(raw))
elif spec["type"] == "float":
val = repr(float(raw))
elif spec["type"] == "choice":
if str(raw) not in spec["choices"]:
return False, None, "%s must be one of %s" % (spec["name"], spec["choices"])
val = str(raw)
else:
val = str(raw)
if any(ch in val for ch in "\0\n\r"):
return False, None, "%s: invalid characters" % spec["name"]
except (TypeError, ValueError):
return False, None, "%s: invalid %s" % (spec["name"], spec["type"])
if spec.get("flag"):
argv.append(spec["flag"])
argv.append(val)
argv += list(tool.get("argv_fixed_after", []))
return True, argv, None
def record(self, tool, args, run):
rec = {"ts": run.started_ts, "tool": tool["id"], "args": args, "result": run.finished,
"log_tail": run.lines[-50:]}
with self._lock:
os.makedirs(os.path.dirname(self.index_path), exist_ok=True)
with open(self.index_path, "a", encoding="utf-8") as f:
f.write(json.dumps(rec, sort_keys=True, separators=(",", ":")) + "\n")
def last_runs(self):
out = {}
try:
with open(self.index_path, "r", encoding="utf-8") as f:
for line in f:
try:
rec = json.loads(line)
except ValueError:
continue
out[rec.get("tool")] = {"ts": rec.get("ts"), "result": rec.get("result"),
"args": rec.get("args")}
except OSError:
pass
return out
def listing(self):
last = self.last_runs()
items = []
for t in self.tools:
item = {k: t[k] for k in ("id", "title", "script", "safety", "where", "ported", "args", "desc")}
item["installed"] = os.path.exists(os.path.join(self.tool_dir(), t["script"]))
item["last"] = last.get(t["id"])
items.append(item)
return items
def describe_command(self, tool, args):