Adds the design matrix and its supporting tools, and records in BRINGUP what the 60-run matrix overturned: sub-40-percent duty mimics flow (three of five dead-pump trials looked healthier than a working pump), the operating point and threshold now rest on 25 pooled observations, periodic re-checks are thermally free with the fans running, and the settle gate closes a bench-proven miss. Also records what is NOT yet validated - warm-loop baselines and behaviour under laser heating - as first-light commissioning items.
11 lines
238 B
JSON
11 lines
238 B
JSON
{
|
|
"points": [
|
|
{
|
|
"measured_c": 25.67,
|
|
"raw1": 672.4,
|
|
"raw2": 672.6,
|
|
"note": "IR on reservoir+hoses 78.2F, ambient 78.0F, idle 1h, pump on, heater off",
|
|
"when": "2026-08-02 18:13:41"
|
|
}
|
|
]
|
|
} |