mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-27 08:41:13 -07:00
The acceptance catalog gains the test behind forgectrl 5a31d66: an exhaust floor at the legal maximum must trip AIRFLOW after the grace and three ticks (hold, fire blocked, no resume, the exhaust gate TRIPPED and named in the reason); a purge current floor at the ADC rail must trip the same way; an exhaust floor of zero must read off in gates_off and trip nothing; restored, the next session must run OK with every fan at or above its floor. Three host cases against a scripted engine that models the grace and the readings. The covers map names src/airflow.*. COOLING.md gains 3a (the airflow gates) and the five settings with their ranges and bands; SERVICES.md the gate rule, the rows, the AIRFLOW verdict and fan_gates; SAFETY.md names the floors among the verdict's inputs; BRINGUP item 19 records the gates as in with provisional floors and the catalog at 44. Pins: forgectrl 5a31d66, forgefirm-app 81027ff (0.1.15+git); fetch-verified.