ScottW514 619414ed2b cloud suite: a print turned away before the button fails at once, with the reason
The cloud client turns a print away before the button wait for four
reasons of its own (machine._safe_to_move): the lid or the interlock, a
machine that is not idle, the coolant above its start ceiling
(THERMAL.max_start_temp), a coolant sensor that reads nothing. It logs the
reason and finishes the print ':cancelled' within a millisecond. The four
tests that wait for the button looked only for the wait, so on the bench
reference, with the loop at 27.4 C against the ceiling of 27,
cloud.dark-print sat out its 120 s and said "the print never reached the
button wait".

wait_button_wait replaces the four waits: it ends on the print's finish
line as well, and fails with the client's own lines, for example "the
client turned the print away before the button wait: INFO
machine:_safe_to_move machine temp is too high, temp: 27.4 (... finished
with event ":cancelled")". The ceiling is the client's and stays where it
is: the remedy for a warm loop is airflow, a run session for a minute or
two.

Proven. test_a_print_turned_away_before_the_button_fails_at_once_with_the_reason
replays the bench reference's lines and fails in under 30 s with that
reason; with the early exit disabled it fails after the full 120 s with the
old words. Each reason is a line the pinned cloud library can log, so the
phrase check passes. The unit suite passes (422) with no undefined name. On
the bench reference, image 20260920211625 with this cloud.py over the
image's, cloud.dark-print passes through the new wait with the loop at
25.8 C.

Acceptance. cloud.dark-print, cloud.verdict-refuse,
cloud.lid-during-button-wait, and every test that starts an offline print
go through the new wait. The helper is module text, so every cloud.py
test's fingerprint moves; no product behavior changes.
2026-09-20 18:02:31 -04:00
..
2026-09-18 12:14:22 -04:00
2026-09-18 12:14:22 -04:00

forgetest - the ForgeFIRM release acceptance tool

The daemon behind http://<machine>:8090/ on the dev image: runs the acceptance catalog against the machine, keeps the append-only result log, decides which results still apply to the image that is running, exports the release artifact scripts/release.sh gates on, and serves the bench diagnostics page. The contract - catalog, campaigns, fingerprints, inheritance, the gate, the coverage rule - is the Acceptance page of the documentation site.

Run the host tests

cd forgetest
python3 -m unittest discover -s tests -v

Run the daemon on a workstation (against a mock or a manifest file)

FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine> python3 -m forgetest --port 8090

scripts/manifest-from-tree.py produces tree-manifest.json from the recipe pins; the coverage lint is python3 -m forgetest.coverage --manifest ....

Environment

Variable Default Purpose
FORGETEST_DATA /data/forgetest results.jsonl, bench.jsonl, token, export/
FORGETEST_MANIFEST /etc/forgefirm-manifest.json the image manifest
FORGETEST_PORT, FORGETEST_HOST 8090, 0.0.0.0 listener
FORGETEST_BENCH_DIR /usr/share/forgetest/bench the installed bench scripts
FORGETEST_BENCH_DATA <FORGETEST_DATA>/bench passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN)
FORGETEST_MARKER /run/forgetest.active takeover marker
FORGECTRL_URL, FORGECTRL_TOKEN_FILE http://127.0.0.1, /data/forgefirm/panel.token forgectrl client (HTTP; the token authorizes writes from the board)
FORGECTRL_TLS_URL https://127.0.0.1 forgectrl over HTTPS (self-signed, unverified), for the login test
GF_SYSFS_ROOT /sys/glowforge/ kernel module sysfs
GRBL_HOST, GRBL_PORT 127.0.0.1, 23 Grbl TCP

Adding a test

Register it in the subsystem module under forgetest/suite/ with @test(...): id subsystem.name, kind, hardware, mode (the controller mode the test needs; the runner switches to it first), covers, requires, always, steps. The body gets a Context (log, check, fail, prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs, grbl, takeover). Return normally for PASS, raise runner.Failed for FAIL. Then run the unit tests and the coverage lint.