ScottW514 f92147093e Flow-detection experimental record and bench tooling
Adds the design matrix and its supporting tools, and records in BRINGUP
what the 60-run matrix overturned: sub-40-percent duty mimics flow
(three of five dead-pump trials looked healthier than a working pump),
the operating point and threshold now rest on 25 pooled observations,
periodic re-checks are thermally free with the fans running, and the
settle gate closes a bench-proven miss. Also records what is NOT yet
validated - warm-loop baselines and behaviour under laser heating - as
first-light commissioning items.
2026-08-02 23:51:31 -04:00

11 lines
238 B
JSON

{
"points": [
{
"measured_c": 25.67,
"raw1": 672.4,
"raw2": 672.6,
"note": "IR on reservoir+hoses 78.2F, ambient 78.0F, idle 1h, pump on, heater off",
"when": "2026-08-02 18:13:41"
}
]
}