forgectrl pin b27398a: the SoC die joins the watched board temperatures
(/status temps soc_c and the kernel's CPU cooling state soc_throttle,
the Status tab, the per-job range line naming a throttle), a throttle
starting or ending is logged, and the supply sensor stays a raw count by
decision (its heatsink cannot be reached with a thermometer while the
machine runs). forgefirm-app pin e65cfc2 (0.1.16+git): every pulse-header
key without an applier is declared with its reason or counted as
undecided in the job log, and CLOUD.md carries one disposition table for
the whole header.
BRINGUP: the pulse-header envelope item is closed. Its durable content is
in the facts bank ("The factory's envelope, decoded": the mandatory tags,
the empty tach windows, the factory's pause and fail tiers, the
per-sensor units, the unarmed flow controller, and ForgeFIRM's answer
with its catalog proofs) and in the "Deliberately not gated" paragraph,
which names every declared family. Item 19 is now the bench-measured
head crash and rail-contact detector; the fire-watch item holds the
header's lid IR thresholds as its prior. The facts bank also records the
SoC's own thermal guard (85 C passive, 90 C critical, no heatsink on the
factory board) and the board temperatures at idle.
Catalog: cooling.gate-off checks the die field, the unthrottled state at
idle and the widened run-end line (the unit fake mirrors it). COOLING
section 9 and the SERVICES verification status describe the present.
forgetest - the ForgeFIRM release acceptance tool
The daemon behind http://<machine>:8090/ on the dev image: runs the
acceptance catalog against the machine, keeps the append-only result log,
decides which results still apply to the image that is running, exports
the release artifact scripts/release.sh gates on, and serves the bench
diagnostics page. The contract - catalog, campaigns, fingerprints,
inheritance, the gate, the coverage rule - is
docs/ACCEPTANCE.md.
Run the host tests
cd forgetest
python3 -m unittest discover -s tests -v
Run the daemon on a workstation (against a mock or a manifest file)
FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine>:8080 python3 -m forgetest --port 8090
scripts/manifest-from-tree.py produces tree-manifest.json from the recipe
pins; the coverage lint is python3 -m forgetest.coverage --manifest ....
Environment
| Variable | Default | Purpose |
|---|---|---|
FORGETEST_DATA |
/data/forgetest |
results.jsonl, bench.jsonl, token, export/ |
FORGETEST_MANIFEST |
/etc/forgefirm-manifest.json |
the image manifest |
FORGETEST_PORT, FORGETEST_HOST |
8090, 0.0.0.0 | listener |
FORGETEST_BENCH_DIR |
/usr/share/forgetest/bench |
the installed bench scripts |
FORGETEST_BENCH_DATA |
<FORGETEST_DATA>/bench |
passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN) |
FORGETEST_MARKER |
/run/forgetest.active |
takeover marker |
FORGECTRL_URL, FORGECTRL_TOKEN_FILE |
http://127.0.0.1:8080, /data/forgefirm/panel.token |
forgectrl client |
GF_SYSFS_ROOT |
/sys/glowforge/ |
kernel module sysfs |
GRBL_HOST, GRBL_PORT |
127.0.0.1, 23 | Grbl TCP |
Adding a test
Register it in the subsystem module under forgetest/suite/ with
@test(...): id subsystem.name, kind, hardware, mode (the controller
mode the test needs; the runner switches to it first), covers,
requires, always, steps. The body gets a Context (log, check, fail,
prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs,
grbl, takeover). Return normally for PASS, raise runner.Failed for
FAIL. Then run the unit tests and the coverage lint.