Files
forgefirm/forgetest/tests
ScottW514 cd5098b6b3 Acceptance catalog: merge the tests that share a setup (39 -> 35, live 10 -> 7)
A sweep of the whole catalog for the overlap the drill work found. The test
applied was "do these share a SETUP", not "do these share a subsystem":
combining only pays where a human waits - an arm press, scrap, a takeover,
a mode entry, a lid choreography - and it costs failure isolation, because
the campaign inherits per test and a merged test invalidates as a unit. The
17 auto tests were left alone for exactly that reason: they cost no operator
time and separate ids give the coverage map and the domain invalidation
finer teeth.

  kernel.k3-unlock + kernel.fire-abu -> kernel.fire-line
      Four phases behind ONE takeover of the pulse device instead of two:
      A/B/U on the FIRE line, then the mid-ramp unlock. Same HV-not-good
      gate, same zero duty, same safe state on the way out.

  laser.expected-stop + laser.kill-mid-fire -> laser.armed-kill
      Both ways an armed job is killed, on one scrap setup: the supervisor's
      expected stop (with its separate operator-judged restart) and then a
      SIGKILL of the restarted controller. The second phase re-reads the pid
      after the restart, so it kills the process the supervisor just spawned.

  laser.lid-cancel-mid-fire + laser.pause-resume-live -> laser.pause-resume-lid-cancel
      One armed burn in the order the factory uses the machine's controls:
      press (pause - emission stops, latch stays UNLOCKED, armed window
      stays open), press (resume), lid (cancel, reset without alarm, return
      to the job start, button latch SET). One arm press instead of two.

  cloud.lid-abort + cloud.interlock-abort-park -> cloud.lid-interlock-abort
      Two prints in one test: the lid, then the interlock with the lid opened
      during the park. The tail both share - park complete, kernel counters
      back at the job start, ':cancelled', latch locked, armed window closed -
      is one helper now, so both triggers are judged the same way.

Not merged, though they share code: cloud.gfhome-homing and cloud.hunt-lid-open.
Both drive Machine._hunt (gfhome.py and gfcloud.py build the same gfhardware
machine, so the lid ungating is the same lines), but each is about the opposite
value of the same variable - gfhome's homing is camera-corrected and needs the
lid CLOSED in GRBL mode, the hunt test needs it OPEN through a cloud-mode
connect. Merging would put a mid-test mode switch back into the cloud tests.

Shared live-test prologue (the arm cue, the mark job, the wait for the emission
witness) and the post-kill trail/judging are helpers now.

Host proof: 104 unit tests - the merged cloud test replays the machine's own
lid-abort excerpt twice, once with the interlock substituted for the trigger,
and three negative cases hold it honest (loop already open, a park the lid can
interrupt, a stop that is not edge-driven) - and the coverage lint at 0
uncovered across 35 tests. Catalog time 137 -> 125 minutes, 96 of it attended.
2026-08-17 08:39:35 -04:00
..