ScottW514 4c5dde2549 forgetest: the burns, the lens and the intake checks follow forgectrl's review fixes
- baseline: the lid lamp fades to a new level (the kernel's smooth
  trigger), so the hand-back reads it until it holds the wanted level
  twice in a row, for up to 3 s, before it is a leftover.
  motion.deadman failed its hand-back reading 232 against 236 0.05 s
  after the supervisor re-applied 236 to a respawned controller.
- setup.check-lens and setup.focus: grblHAL reads the lens window and
  the edge only at its start, and their restore came after the wizard
  had restarted the controller on the test's values. Each test now waits
  for the step to end, puts the settings back, and restarts the
  controller (stop, start, running and verified with a new pid) on every
  exit path; cloud mode restarts nothing.
- setup.focus and setup.floor: the served program ends with G0 Z<edge>,
  G0 X0 Y0, G92.1, M2; setup.floor requires setup.focus and checks the
  scrap's thickness against the lens reach; the burns cover lenshome.
- setup.check-intakes: the two assertions that could not fail are gone;
  an intake-count prompt fails the test unanswered (the bench
  reference's intakes both turn). The precheck's refusal names no
  setting.
- setup.check-airflow: the machine's count rules (intake 2 turning
  writes 2; silent on a one-fan machine, the count is not written).

Shared text: setup_dark.py's precheck string (all setup_dark tests,
setup_burns, setup.check-envelope), setup_burns.py's imports, covers,
docstring and preview check, cooling_intake.py's docstring; every test
they move covers paths forgectrl changed in the same work.

Proof: the forgetest host suite passes (548), with new host tests for
the lamp's fade, the restarts on pass, fail and abort, the floor's Focus
refusal and reach, the tail without G92.1, the intakes prompt, and the
airflow count rules; pyflakes is clean on the changed modules.

Acceptance: these are the tests.
2026-10-12 19:53:20 -04:00
..
2026-09-18 12:14:22 -04:00

forgetest - the ForgeFIRM release acceptance tool

The daemon behind http://<machine>:8090/ on the dev image: runs the acceptance catalog against the machine, keeps the append-only result log, decides which results still apply to the image that is running, exports the release artifact scripts/release.sh gates on, and serves the bench diagnostics page. The contract - catalog, campaigns, fingerprints, inheritance, the gate, the coverage rule - is the Acceptance page of the documentation site.

Run the host tests

cd forgetest
python3 -m unittest discover -s tests -v

Run the daemon on a workstation (against a mock or a manifest file)

FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine> python3 -m forgetest --port 8090

scripts/manifest-from-tree.py produces tree-manifest.json from the recipe pins; the coverage lint is python3 -m forgetest.coverage --manifest ....

Environment

Variable Default Purpose
FORGETEST_DATA /data/forgetest results.jsonl, bench.jsonl, token, export/
FORGETEST_MANIFEST /etc/forgefirm-manifest.json the image manifest
FORGETEST_PORT, FORGETEST_HOST 8090, 0.0.0.0 listener
FORGETEST_BENCH_DIR /usr/share/forgetest/bench the installed bench scripts
FORGETEST_BENCH_DATA <FORGETEST_DATA>/bench passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN)
FORGETEST_MARKER /run/forgetest.active takeover marker
FORGECTRL_URL, FORGECTRL_TOKEN_FILE http://127.0.0.1, /data/forgefirm/panel.token forgectrl client (HTTP; the token authorizes writes from the board)
FORGECTRL_TLS_URL https://127.0.0.1 forgectrl over HTTPS (self-signed, unverified), for the login test
GF_SYSFS_ROOT /sys/glowforge/ kernel module sysfs
GRBL_HOST, GRBL_PORT 127.0.0.1, 23 Grbl TCP

Adding a test

Register it in the subsystem module under forgetest/suite/ with @test(...): id subsystem.name, kind, hardware, mode (the controller mode the test needs; the runner switches to it first), covers, requires, always, steps. The body gets a Context (log, check, fail, prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs, grbl, takeover). Return normally for PASS, raise runner.Failed for FAIL. Then run the unit tests and the coverage lint.