Files
forgefirm/scripts
ScottW514 ef15c55577 laser_stream_test: the verdict's holds ship no FIRE while held
Rules 24 (the pause tier, held and held again) and 27 (a stale verdict)
asserted the deceleration into each hold ran lit to the stop, the
stretch between the holds dark, and the cut lit after the clear, but not
that the stream is dark inside a hold: the central claim of the
catalog's laser.verdict-cut, which can leave the catalog once the host
proves it. Rule 21 proved it only for a plain feed hold.

- check_hold_dark: no FIRE tick inside a hold's stationary stretch, its
  edges aside (one step pulse straddles each edge: rule 21's margin,
  HOLD_EDGE_TICKS, 120 ticks at x8 scaled to the mode: 480 at the x32
  default).
- Rule 24 checks both of its holds; rule 27 checks its one hold.
- check_fire_gaps runs on both sessions, as on rule 21's.
- The header's rules 24 and 27 say so; their PASS lines report the held
  stretches.

Proof: laser_stream_test passes whole on a null-sink build of the
grblHAL-glowforge working tree under Linux: verdict-rehold dark while
held for 22620 and 22622 ticks, verdict-stale for 22621, check_fire_gaps
clean on both. A negative control on check_hold_dark: a dark 5000-tick
hold passes, and one FIRE tick inside it fails. pyflakes is clean.

Acceptance: none. The harness runs in grblHAL-glowforge's CI.