ScottW514 0c2dd37b2f Cover both dose models explicitly now that density is the default
grblHAL-glowforge 03d70e0, pinned here, makes density the shipped model
and $35 the density floor at 10. Every analog session in the stream
harness now selects its model rather than inheriting it: without that the
flip would have quietly turned them into density runs and taken the
analog fallback's coverage with them. laser.power-floor carries the new
floor and its PWMSAR minimum, and its description no longer describes
$35 as a duty floor.

All ten stream sessions pass on the new defaults, with the analog duties
shifting exactly as the floor predicts - min_value 12, gradient 0.115 -
along with both C harnesses and the lifecycle harness.

Recorded in BRINGUP and the campaign log, including what the defaults
rest on and what they do not: the seven ladders ran at F300 and F100 at
constant power, so production feeds, M4 into corners and the raster path
remain unproven on hardware.
2026-08-17 22:03:56 -04:00
..

forgetest - the ForgeFIRM release acceptance tool

The daemon behind http://<machine>:8090/ on the dev image: runs the acceptance catalog against the machine, keeps the append-only result log, decides which results still apply to the image that is running, exports the release artifact scripts/release.sh gates on, and serves the bench diagnostics page. The contract - catalog, campaigns, fingerprints, inheritance, the gate, the coverage rule - is docs/ACCEPTANCE.md.

Run the host tests

cd forgetest
python3 -m unittest discover -s tests -v

Run the daemon on a workstation (against a mock or a manifest file)

FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine>:8080 python3 -m forgetest --port 8090

scripts/manifest-from-tree.py produces tree-manifest.json from the recipe pins; the coverage lint is python3 -m forgetest.coverage --manifest ....

Environment

Variable Default Purpose
FORGETEST_DATA /data/forgetest results.jsonl, bench.jsonl, token, export/
FORGETEST_MANIFEST /etc/forgefirm-manifest.json the image manifest
FORGETEST_PORT, FORGETEST_HOST 8090, 0.0.0.0 listener
FORGETEST_BENCH_DIR /usr/share/forgetest/bench the installed bench scripts
FORGETEST_BENCH_DATA <FORGETEST_DATA>/bench passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN)
FORGETEST_MARKER /run/forgetest.active takeover marker
FORGECTRL_URL, FORGECTRL_TOKEN_FILE http://127.0.0.1:8080, /data/forgefirm/panel.token forgectrl client
GF_SYSFS_ROOT /sys/glowforge/ kernel module sysfs
GRBL_HOST, GRBL_PORT 127.0.0.1, 23 Grbl TCP

Adding a test

Register it in the subsystem module under forgetest/suite/ with @test(...): id subsystem.name, kind, hardware, covers, requires, always, steps. The body gets a Context (log, check, fail, prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs, grbl, takeover). Return normally for PASS, raise runner.Failed for FAIL. Then run the unit tests and the coverage lint.