Files
forgefirm/forgetest
ScottW514 f306c9983f forgetest: the hand-back reads an engine hold again past the engine's next tick
The cooling engine publishes its state once a tick (1 Hz). A /cool/status
read inside the tick after a run ended still shows the run: while a
diagnostic owns the hardware every tick publishes phase "diag" with the
hold set, and a fail tier's hold stands until the tick that ends its
session. The baseline took one read, and by its rule an arm or a hold is
the run's doing, so a test that finished inside that second failed its
hand-back on a hold the engine's next tick cleared.

Seen on the bench reference twice. cooling.aa-offset-calibrate in campaign
c-20260919215024-c402: the diagnostic reported done at 22:07:14 with its
offset measured (15.7 counts, spread 0.7), and the hand-back at 22:07:15
read "cool=diag/armed=False/hold=True ... -> waited" and failed the run;
the test had passed on five images before, the last one earlier the same
day. cooling.fail-tier-stop in c-20260919202934-3d3a, the same way on the
crash fault's hold (0ceb4ab made that test wait for its own fault; this is
the general case).

The cooling check moves into Baseline._cool_side. An arm or a hold is read
again for up to COOL_PUBLISH_S (2.5 s: two ticks and a margin) before it is
called the run's doing. One the next tick cleared is logged as the engine's
last word on the run and judged on what the engine reads then: idle is
clean, a cooldown phase is waited out as the engine's own post-job work. A
hold a run did leave stands for a job that is never coming back, so it is
still there after the tick and is recorded, stood down and failed exactly
as before; a hold that clears only later is still a leftover ("waited").

Proven: tests/test_baseline.py CoolPublishTests - a diagnostic's hold the
next tick clears, a fail tier's hold clearing into the smoke phase, a hold
that outlives the tick (recorded, machine stood down), a hold that clears
only later (recorded as waited), an idle engine and a silent daemon; the
baseline, queue, operator, mode, responsiveness and server host tests
pass under Linux. baseline.py is not a suite module, so no test's
fingerprint moves with it.
2026-09-19 18:16:04 -04:00
..
2026-09-18 12:14:22 -04:00
2026-09-18 12:14:22 -04:00

forgetest - the ForgeFIRM release acceptance tool

The daemon behind http://<machine>:8090/ on the dev image: runs the acceptance catalog against the machine, keeps the append-only result log, decides which results still apply to the image that is running, exports the release artifact scripts/release.sh gates on, and serves the bench diagnostics page. The contract - catalog, campaigns, fingerprints, inheritance, the gate, the coverage rule - is the Acceptance page of the documentation site.

Run the host tests

cd forgetest
python3 -m unittest discover -s tests -v

Run the daemon on a workstation (against a mock or a manifest file)

FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine> python3 -m forgetest --port 8090

scripts/manifest-from-tree.py produces tree-manifest.json from the recipe pins; the coverage lint is python3 -m forgetest.coverage --manifest ....

Environment

Variable Default Purpose
FORGETEST_DATA /data/forgetest results.jsonl, bench.jsonl, token, export/
FORGETEST_MANIFEST /etc/forgefirm-manifest.json the image manifest
FORGETEST_PORT, FORGETEST_HOST 8090, 0.0.0.0 listener
FORGETEST_BENCH_DIR /usr/share/forgetest/bench the installed bench scripts
FORGETEST_BENCH_DATA <FORGETEST_DATA>/bench passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN)
FORGETEST_MARKER /run/forgetest.active takeover marker
FORGECTRL_URL, FORGECTRL_TOKEN_FILE http://127.0.0.1, /data/forgefirm/panel.token forgectrl client (HTTP; the token authorizes writes from the board)
FORGECTRL_TLS_URL https://127.0.0.1 forgectrl over HTTPS (self-signed, unverified), for the login test
GF_SYSFS_ROOT /sys/glowforge/ kernel module sysfs
GRBL_HOST, GRBL_PORT 127.0.0.1, 23 Grbl TCP

Adding a test

Register it in the subsystem module under forgetest/suite/ with @test(...): id subsystem.name, kind, hardware, mode (the controller mode the test needs; the runner switches to it first), covers, requires, always, steps. The body gets a Context (log, check, fail, prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs, grbl, takeover). Return normally for PASS, raise runner.Failed for FAIL. Then run the unit tests and the coverage lint.