Files
forgefirm/forgetest
ScottW514 9a288b175b Track the x32 xy_microsteps default in forgetest and the bench tools
Acceptance baseline: XY_MODE_DEFAULT 8 -> 32, split out XY_MODE_BASE (8) for
the tick/ramp scaling, matching the driver. The mode-aware comparisons
(fixed_sysfs of the resolved mode) judge an unset machine at x32.

Host CI: xy_mode_test.py default and invalid cases expect x32/213.333/112640.

Bench tools: raster_dry.py and xy_pattern_accel.py set_mode() cleared the key
for mode 8, which relied on clear == the x8 default; clearing now yields x32,
so they set the mode explicitly and restore to x32. live_fire_drills
STREAM_RATE_HZ is the 28160 Hz laser reference tick, the same at every mode.
2026-09-16 15:39:20 -04:00
..

forgetest - the ForgeFIRM release acceptance tool

The daemon behind http://<machine>:8090/ on the dev image: runs the acceptance catalog against the machine, keeps the append-only result log, decides which results still apply to the image that is running, exports the release artifact scripts/release.sh gates on, and serves the bench diagnostics page. The contract - catalog, campaigns, fingerprints, inheritance, the gate, the coverage rule - is the Acceptance page of the documentation site.

Run the host tests

cd forgetest
python3 -m unittest discover -s tests -v

Run the daemon on a workstation (against a mock or a manifest file)

FORGETEST_DATA=/tmp/ft FORGETEST_MANIFEST=../tree-manifest.json \
FORGECTRL_URL=http://<machine> python3 -m forgetest --port 8090

scripts/manifest-from-tree.py produces tree-manifest.json from the recipe pins; the coverage lint is python3 -m forgetest.coverage --manifest ....

Environment

Variable Default Purpose
FORGETEST_DATA /data/forgetest results.jsonl, bench.jsonl, token, export/
FORGETEST_MANIFEST /etc/forgefirm-manifest.json the image manifest
FORGETEST_PORT, FORGETEST_HOST 8090, 0.0.0.0 listener
FORGETEST_BENCH_DIR /usr/share/forgetest/bench the installed bench scripts
FORGETEST_BENCH_DATA <FORGETEST_DATA>/bench passed to bench tools: where they keep their data files (with GF_HOST=127.0.0.1 and the panel token in GF_TOKEN)
FORGETEST_MARKER /run/forgetest.active takeover marker
FORGECTRL_URL, FORGECTRL_TOKEN_FILE http://127.0.0.1, /data/forgefirm/panel.token forgectrl client (HTTP; the token authorizes writes from the board)
FORGECTRL_TLS_URL https://127.0.0.1 forgectrl over HTTPS (self-signed, unverified), for the login test
GF_SYSFS_ROOT /sys/glowforge/ kernel module sysfs
GRBL_HOST, GRBL_PORT 127.0.0.1, 23 Grbl TCP

Adding a test

Register it in the subsystem module under forgetest/suite/ with @test(...): id subsystem.name, kind, hardware, mode (the controller mode the test needs; the runner switches to it first), covers, requires, always, steps. The body gets a Context (log, check, fail, prompt, confirm, instruct, sleep, evidence, forgectrl, sysfs, grbl, takeover). Return normally for PASS, raise runner.Failed for FAIL. Then run the unit tests and the coverage lint.