mirror of
https://github.com/openglow-org/forgefirm.git
synced 2026-09-27 08:41:13 -07:00
Next-work item 19 carried three open questions about the factory's operating envelope. All three are answered now, so the item states the policy instead of the guess. A fan tach alert during a cut pauses the print, taking the same transition a user pause takes, and two of the factory's three tach monitors cannot fire at all: they treat a zero limit as unconfigured and the limits arrive zero anyway. So a stalled extraction fan is caught by the temperature it causes, not by its tachometer. Every temperature alert pauses as well, and a critical fails the machine outright, which is a different state and not a pause. The scale question behind the header's ceilings is answered by the coolant family, which the factory carries twice, once in raw ADC counts where the tag named min is the hot limit, and once in millidegrees. And the factory does not verify coolant flow at all, so the cooling engine's flow check is ahead of the factory rather than behind it. The crash, tilt and beam-detect bullets gain the same grading: an alert threshold that pauses and a separate abort threshold that aborts. Also drops references to paths that resolve outside this repo, in both documents and in two bench scripts, naming the artifact instead. In CAMPAIGN-LOG that is a wording substitution only; no date, claim or measurement changes. Documentation only, so no acceptance catalog consequence.