ScottW514 cced57da6c bench: platform drills, cutting-power lid-IR and expected-stop live drills, SIGTERM lifecycle case
- platform_drills.py (on the board, forgectrl stopped): dead-man trip
  readback, rmmod/modprobe with concurrent attr reads, decay/microstep
  readback, LED sequence.
- live_fire_drills.py: ircut (S/F selectable characterization job),
  expstop (armed job + POST /controller/stop, controller left stopped),
  ctrlstart (separate, operator-approved resume); the token header is sent
  in exact case.
- laser_lifecycle_test.py: sigterm-mid-job - SIGTERM during an armed job
  must stop it, relock the latch and exit promptly.
2026-08-15 08:38:29 -04:00
ScottW514 26ed519348 bench: surface the controller stderr when the harness cannot connect
A startup failure previously reported only cannot-connect with the
process stderr discarded - undiagnosable in CI.
2026-08-14 19:10:38 -04:00
ScottW514 9e9d03ba94 bench: armed-window lifecycle harness (null-sink, host-side)
Four sessions against the reported messages: arm once per job with
M5/M3 persistence and the M2 close (grace pushed beyond the horizon so
only the program-end path can disarm); a displaced sender must re-arm;
the disarm grace counts down in Hold; a blocking cooling verdict
refuses the arm. Test-the-test proven: a build with the job-based
window reverted fails at the first discriminating assertion. Wired
into the controller repo CI alongside the emission harness.
2026-08-14 19:07:29 -04:00