ScottW514 cced57da6c bench: platform drills, cutting-power lid-IR and expected-stop live drills, SIGTERM lifecycle case
- platform_drills.py (on the board, forgectrl stopped): dead-man trip
  readback, rmmod/modprobe with concurrent attr reads, decay/microstep
  readback, LED sequence.
- live_fire_drills.py: ircut (S/F selectable characterization job),
  expstop (armed job + POST /controller/stop, controller left stopped),
  ctrlstart (separate, operator-approved resume); the token header is sent
  in exact case.
- laser_lifecycle_test.py: sigterm-mid-job - SIGTERM during an armed job
  must stop it, relock the latch and exit promptly.
2026-08-15 08:38:29 -04:00
ScottW514 ea0642f942 Record live-fire drill results: emission witness, HV, lid-IR, X-3, G-10
Phase 5 A-1 emission witness and A-5 HV telemetry pass on live burns;
A-2 lid-IR characterized as a weak signal at 40% (gate left watch-only);
pgood confirmed unusable as a witness on this PSU. Phase 4 X-3 (0.1s
job-based disarm on M2) and G-10 (disarm counts down in Hold) pass.
Adds live_fire_drills.py (arm-lifecycle sampler over TCP + HTTP).