Commit Graph
5 Commits
Author SHA1 Message Date
ScottW514 d530f773e2 cloud.pause-resume reads the job's limits through; pin the pass-through
The pulse header's envelope now reaches the cooling engine: the cloud
client (python3-gfhardware c34faa1) derives the coolant window and the
fans' minimum speeds from the header and rides them on every report,
and the engine (forgectrl 57f6064) resolves each as the stricter of its
setting and the job's, never looser and never overruling an off gate.
cloud.pause-resume, which runs a real print, now also reads the client's
"job limits from the header:" line and the engine's "effective limits:"
line from the two logs; two host cases cover the failure paths. The
needle guard lists the engine's phrases as not the app's.

COOLING.md section 2 explains what a cloud job brings with it; BRINGUP
item 19 records the pass-through as landed. Pins: forgectrl 57f6064,
forgefirm-app c34faa1 (0.1.14+git); fetch-verified.
2026-08-21 18:07:41 -04:00
ScottW514 bf3483e994 cooling.gate-off: a gate setting trips in range and is off at its far end
The acceptance catalog gains the test behind forgectrl 9e44fdc: the
coolant ceiling set just over its legal minimum must trip OVERTEMP with
a hold and fire blocked at the next run start; set to its top the engine
must skip the gate (verdict OK), report it in gates_off on /status and
/cool/status, and log the run-start line; the original values are
restored, on failure too, and proven restored. Five host cases against a
scripted engine. The cooling covers map now names the files that carry
gate state (gates, settings, status, the panel) and corrects a glob that
matched nothing: the GRBL cooling client is src/glowforge_cooling.c, not
src/gfcool*. The fake forgectrl serves /logs/tail and keeps blank form
values as "clear", which is what the daemon does with them.

Docs: COOLING.md section 8 carries each setting's legal range and
recommended band and a new 8a on turning a gate off; SAFETY.md names
what no setting can reach; ACCEPTANCE.md records that gates are
exercised through the settings API, never GFCOOL_* env overrides;
BRINGUP item 19 records the pattern as landed and the catalog is 43.

forgectrl pin moves to 9e44fdc; fetch-verified.
2026-08-21 17:06:49 -04:00
ScottW514 5a587c3536 Name the verdict, not the report, in the stale-verdict rule
The section describes two channels flowing opposite ways - the
controller's job-state reports and the engine's verdict - so "the report"
pointed at the wrong one directly under a lead that names the verdict.
2026-08-18 07:43:16 -04:00
ScottW514 7012c7d1b2 Homing is lid-gated in practice; only the cloud hunt is not
MOTION said jogs, homing and hunts were all ungated. Jogs are:
gfsw_visible withholds the door signal while the core is idle, jogging or
homing, so a jog both starts and runs with the lid open. Homing is not.
With homing_mode = gfcloud - the only method that works today - $H hands
the cycle to a cloud homing session, and its move to the home corner is
an ordinary motion action taking the default lid_gated=True: refused with
the lid open, stopped on a lid edge mid-run. Only the lens/Z hunt inside
that session passes lid_gated=False, and that session is also the only
place a hunt happens in GRBL mode - there is no hunt outside one.

BRINGUP gains item 18: GRBL pause and resume should leave no gap in the
cut, the way the factory's does. The beam stops at the start of the hold
(disable_laser_during_hold, on by default), so the head travels the whole
deceleration dark and the resume restarts from a standstill where the
decel ended - an unburned length, then a dwell through the accel that M3
shows as a deeper spot. The kernel waypoint backtrack cloud mode uses is
refused with EPERM on a live-streamed ring, so the equivalent has to be
built above the ring, where grblHAL still holds the planned path the
kernel has already overwritten.

Two wording fixes: the cooling verdict is described as a report rather
than a file, and gfcloud homing as using the machine's builtin
credentials.

Documentation only - no behavior change, so no acceptance-catalog
consequence.
2026-08-18 07:41:37 -04:00
ScottW514 d3bab940b3 docs: user-facing guides to motion, laser drive and cooling
Two pages aimed at someone who owns the machine rather than works on it,
written for the documentation site. Nothing here is new behavior - it is
the behavior the machine already has, explained where an owner can find
it instead of spread across a kernel contract, a services contract and
three driver headers.

MOTION.md follows one thread: everything physical comes out of a single
fixed-tick byte stream, so the page starts there - the byte layout, speed
as step density rather than clock, the ring and the two ways to fill it,
and the hardware's own stop, halt and resume-with-waypoint. The laser is
presented as part of that stream rather than beside it, which is what
makes the three contract rules (power before fire, no consecutive power
bytes, end dark) and the persisting duty legible instead of arbitrary.
Then geometry and limits, device ownership and the liveness check the
operator sees, and the two modes in full: GRBL from connection through
the arming sequence, the stop/pause/fault table and homing-or-not; cloud
from the preloaded pulse file through the pause backtrack, the park that
ignores the lid, and the ring's cap on job length. A comparison table and
the motion-related settings close it.

COOLING.md explains the engine as what it is - one owner of the thermal
hardware answering a single question for whichever controller runs - and
gives the reasons behind the numbers rather than just the numbers: why
the flow check heats and measures the downstream rise, why 40 percent is
the duty (below it, convection mimics flow), why the settle gate uses a
split-half mean instead of peak-to-peak, and why one bad reading is a
suspicion rather than a fault. Over-temperature, the two diagnostics
tools and when to run them, the settings, and a situation-to-response
table. The fire watch is described honestly: the lid IR channels are
first of all a photometer for the lid lamp, the gate ships watch-only,
and it is not a fire alarm.

Both pages state what is not implemented - low-temperature gates, TEC
control, a fire watch that acts, limit-switch homing - so nobody plans
around them. Constants come from the sources that own them (the feeder
contract, cool.h, the board header, the services contract), not from
prose. README links both.

Documentation only, no behavior change and no catalog consequence: docs/
is outside every layer and .md is excluded from the layer content hash.
2026-08-17 11:52:41 -04:00